RESUMO
Abstract In this study, we evaluated the physicochemical properties (PCP; radiopacity, flow, pH, and solubility) and the quality of root canal filling provided by an experimental industrialized paste (EP), with the same active ingredients as those of the Guedes Pinto paste, compared with the Vitapex® paste. PCP were analyzed according to the ANSI/ADA laboratory testing methods for endodontic filling and sealing materials. To analyze filling capacity, 120 artificial primary teeth (60 maxillary incisors [MIs] and 60 mandibulary molars [MMs]) were endodontically treated. The teeth were divided into eight groups based on the dental group (MIs or MMs), filling material (Vitapex® or EP), and insertion method (syringe or lentulo). The Image J® software was used to analyze the initial an final digital radiographies of each tooth, measuring and comparing root canal and void areas. The percentage of filling failure areas was obtained. Data were submitted to ANOVA and Tukey test of mean comparison. Regarding PCP, both pastes presented results according the ANSI/ADA standards. Flow capacity: Vitapex: 19.6 mm, EP: 25 mm (p < 0.01); radiopacity: Vitapex: 4.47 mmAl, EP: 6.06 mmAl (p < 0.01); pH after 28 days: Vitapex: 7.79, EP: 8.19 (p = 0.12); and solubility after 28 days: Vitapex: 2.68%, EP: 2.89% (p > 0.05). Regarding filling capacity analysis, EP demonstrated 12.5% of failure against 31.5% of Vitapex (p < 0.01). Compared to Vitapex, EP presented statistically significantly better results in flow, radiopacity, pH, and filling capacity. Molars presented more filling failures than incisors. The insertion method using a syringe and a thin tip was significantly better than that using Lentulo spiral carriers.
Assuntos
Dente Decíduo , Radiografia Dentária Digital , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Hidróxido de Cálcio , Hidrocarbonetos IodadosRESUMO
Objetivos: Describir las características craneodentofaciales, tratamientos ortodónticos-quirúrgicos y establecer una aso-ciación entre los tipos de síndrome presentes en pacientes con craneosinostosis sindrómica (CS). Material y métodos: Estudio retrospectivo de registros médicos y de ortodoncia de pacientes con CS. Los datos se recogieron en una forma específica y se sometieron a un análisis estadístico descriptivo para observar la distribución de frecuencias y se utilizó la prueba de Chi cuadrado con un nivel de significación del 5% para asociar el síndrome y los tipos de variables. Resultados: El síndrome de Crouzon fue el tipo predominante (59.2%) y la braquicefalia fue el tipo más frecuente de craneosinostosis (63.6%). Hubo una asociación significativa entre las variables braquicefalia (p = 0,014), presencia de paladar hendido (p = 0,043), mordida cruzada posterior (p = 0,013), distracción osteogénica realizada por elásticos intermaxilares (p = 0,030), barra de Erich (p = 0.007) y la extracción (p = 0.041) y los síndromes estudiados. Conclusión: Los pacientes con CS a menudo tienen cambios craneodentofaciais y algunas variables tienen asociaciones significativas en relación con los tipos de síndromes.
Objectives: Describe the craniodentofacial characteristics, orthodontic-surgical treatments and establish an association between the syndrome types present in patients with syndromic craniosynostosis (SC). Material and methods: Retros-pective study of medical and orthodontic records of patients with SC. Data was collected on a specific form and subjected to descriptive statistical analysis to observe the distribution of frequencies and chi-square test with level of significance of 5% was used to associate syndrome and the types of variables. Results: Crouzon syndrome was the predominant type (59.2%) and brachycephalia was the most prevalent type of craniosynostosis (63.6%). There was a significant association between the variables brachycephaly (p=0.014), presence of cleft palate (p=0.043), posterior cross bite (p=0.013), distrac-tion osteogenesis performed by intermaxillary elastics (p= 0.030), Erich bar (p= 0.007) and extraction (p=0.041) and the syndromes studied. Conclusion: Patients with SC often have craniodentofaciais changes and some variables had signifi-cant associations in relation to the types of syndromes.
Descrever as características craniodentofaciais, tratamentos ortodôntico-cirúrgicos e estabelecer uma associação entre os tipos de síndrome presentes em pacientes com craniossinostose sindrômica (CS). Material e métodos: Estudo retrospectivo de prontuários médicos e ortodônticos de pacientes com CS. Os dados foram coletados em formulário específico e submetidos à análise estatística descritiva para observar a distribuição das frequências e o teste qui-quadrado com nível de significância de 5% foi utilizado para associar a síndrome e os tipos de variáveis. Resultados: A síndrome de Crouzon foi o tipo predominante (59,2%) e a braquicefalia foi o tipo mais prevalente de craniossinostose (63,6%). Houve associação significativa entre as variáveis braquicefalia (p = 0,014), presença de fissura de palato (p = 0,043), mordida cruzada posterior (p = 0,013), distração osteogênica realizada pelos elásticos intermaxilares (p = 0,030), barra de Erich (p= 0,007) e extração (p = 0,041) e as síndromes estudadas. Conclusão: Pacientes com CS frequentemente apresentam alterações craniodentofaciais e algumas variáveis apresentaram associações significativas em relação aos tipos de síndromes.
Assuntos
Humanos , Ortodontia , Distribuição de Qui-Quadrado , Estudos Retrospectivos , Anormalidades Craniofaciais , Disostose Craniofacial , Craniossinostoses , Anormalidades Congênitas , Protocolos Clínicos , Prontuários Médicos , Fissura Palatina , Ajuste Oclusal , Má OclusãoRESUMO
The purpose of this study is to perform a systematic review on the use of lasers in oral surgery for bone healing. Selection of articles was carried out by two evaluators in Pubmed and Web of Science databases for published articles and OpenGray for gray literature. Search strategy was developed based on the PICO Question "Does the use of lasers after oral surgery improve bone healing?". Eligibility criteria were: being on laser; evaluate bone healing; involve oral surgery; do not be about implant, periodontics, orthodontics, osteonecrosis or radiotherapy, nor revisions, clinical cases, etc. Data were collected from each article in a structured spreadsheet and a descriptive analysis was performed. Risk assessment of bias of the articles was carried out through the tool elaborated by the Cochrane collaboration. A total of 827 potentially relevant references were identified. No articles were found in OpenGray. Eleven articles met the eligibility criteria and were included in the systematic review. Most of studies were in vivo and in jaw, being conducted with low-power lasers which were applied immediately after the surgical procedure of extraction. Neoformation and bone density were the outcomes of choice and there was a tendency of increase in bone density, neoformation, regeneration, mineralization, or bone condensation when laser was applied. Regarding the bias risk assessment, studies were not clear in reporting most of the parameters. Low-power laser therapy seems to reduce time of bone healing in oral surgery, although there are no defined protocols and the level of evidence is still considered weak.
Assuntos
Osso e Ossos/efeitos da radiação , Lasers , Procedimentos Cirúrgicos Bucais , Cicatrização/efeitos da radiação , Humanos , Viés de Publicação , Fatores de RiscoRESUMO
OBJECTIVE: The aim of this study was to standardize the nomenclature of pulp alteration to pulp calcification (PC) and to classify it according to type, quantity and location, as well as relate it to clinical and radiographic features. STUDY DESIGN: The dental records of 946 patients from the Research and Clinical Center for Dental Trauma in Primary Teeth were studied. Two hundred and fifty PC-traumatized upper deciduous incisors were detected. RESULTS: According to radiographic analysis of the records, 62.5% showed diffuse calcification, 36.3% tube-like calcification, and 1.2% concentric calcification. According to the extension of pulp calcification, the records showed: 80% partial calcification, 17.2% total coronal calcification and partial radicular calcification, and 2.8 % total coronal and radicular calcification. As for location, only 2.4% were on the coronal pulp, 5.2% on the radicular pulp and 92.4% on both radicular and coronal pulp. Regarding coronal discoloration, 54% were yellow and 2% gray. In relation to periradicular changes, 10% showed widened periodontal ligament space, 3.1% internal resorption, 10% external resorption, 10.4% periapical bone rarefaction. CONCLUSIONS: Since PC is a general term, it is important to classify it and correlate it to clinical and radiographic changes, in order to establish the correct diagnosis, treatment and prognosis of each case.
Assuntos
Calcificações da Polpa Dentária/classificação , Calcificações da Polpa Dentária/diagnóstico , Dente Decíduo/lesões , Pré-Escolar , Calcificações da Polpa Dentária/diagnóstico por imagem , Humanos , Lactente , Radiografia DentáriaRESUMO
The giant cell fibroma is a benign nonneoplastic fibrous tumor of the oral mucosa. It occurs in the first three decades of life in the mandibular gingiva, predominantly, showing predilection for females. This article reports a case of giant cell fibroma in a 2-year-old girl, which is an uncommon age for this lesion. The patient was brought for treatment at the Research and Clinical Center of Dental Trauma in Primary Teeth, where practice for the Discipline of Pediatric Dentistry (Faculty of Dentistry, University of São Paulo, Brazil) takes place. During clinical examination, a tissue growth was detected on the lingual gingival mucosa of the lower right primary incisors teeth. The lesion was excised under local anesthesia and submitted to histological examination at the Oral Pathology Department of the Faculty of Dentistry, University of São Paulo, which confirmed the diagnosis of giant cell fibroma. There was no recurrence after 20 months of monitoring. This instance reinforces the importance of oral care from the very first months of life in order to enable doctors to make precocious diagnosis and offer more appropriate treatments for oral diseases, as well as to promote more efficient oral health in the community.
RESUMO
Dental trauma in immature permanent teeth can damage pulp vascularization, which leads to necrosis and cessation of apexogenesis. Studies on tissue engineering using stem cells from human exfoliated deciduous teeth (SHEDs) have yielded promising results. Laser phototherapy (LPT) is able to influence the proliferation and differentiation of these cells, which could improve tissue engineering. SHEDs (eighth passage) were seeded into 96-well culture plates (103 cells/well) and were grown in culture medium supplemented with 15% defined fetal bovine serum (FBS) for 12 h. After determining the appropriate nutrition deficiency status (5% FBS), the cells were assigned into four groups: 1) G1 - 15% FBS (positive control); 2) G2 - 5% FBS (negative control); 3) G3 - 5% FBS+LPT 3 J/cm2; and 4) G4 - 5% FBS+LPT 5 J/cm2. For the LPT groups, two laser irradiations at 6 h intervals were performed using a continuous wave InGaAlP diode laser (660 nm, with a spot size of 0.028 cm2, 10 mW) in punctual and contact mode. Cell viability was assessed via an MTT reduction assay immediately after the second laser irradiation (0 h) and 24, 48, and 72 h later. We found that G3 and G4 presented a significantly higher cell growth rate when compared with G2 (p < 0.01). Moreover, G4 exhibited a similar cell growth rate as G1 throughout the entire experiment (p > 0.05). These findings indicate that LPT with 5 J/cm2 can enhance the growth of SHEDs during situations of nutritional deficiency. Therefore, LPT could be a valuable adjunct treatment in tissue engineering when using stem cells derived from the dental pulp of primary teeth.
Assuntos
Polpa Dentária/citologia , Terapia com Luz de Baixa Intensidade/métodos , Desnutrição , Células-Tronco/efeitos da radiação , Dente Decíduo/citologia , Análise de Variância , Animais , Bovinos , Proliferação de Células/efeitos da radiação , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Meios de Cultura , Polpa Dentária/efeitos da radiação , Humanos , Radiometria , Reprodutibilidade dos Testes , Fatores de Tempo , Engenharia Tecidual , Dente Decíduo/efeitos da radiaçãoRESUMO
Abstract Dental trauma in immature permanent teeth can damage pulp vascularization, which leads to necrosis and cessation of apexogenesis. Studies on tissue engineering using stem cells from human exfoliated deciduous teeth (SHEDs) have yielded promising results. Laser phototherapy (LPT) is able to influence the proliferation and differentiation of these cells, which could improve tissue engineering. SHEDs (eighth passage) were seeded into 96-well culture plates (103 cells/well) and were grown in culture medium supplemented with 15% defined fetal bovine serum (FBS) for 12 h. After determining the appropriate nutrition deficiency status (5% FBS), the cells were assigned into four groups: 1) G1 - 15% FBS (positive control); 2) G2 - 5% FBS (negative control); 3) G3 - 5% FBS+LPT 3 J/cm2; and 4) G4 - 5% FBS+LPT 5 J/cm2. For the LPT groups, two laser irradiations at 6 h intervals were performed using a continuous wave InGaAlP diode laser (660 nm, with a spot size of 0.028 cm2, 10 mW) in punctual and contact mode. Cell viability was assessed via an MTT reduction assay immediately after the second laser irradiation (0 h) and 24, 48, and 72 h later. We found that G3 and G4 presented a significantly higher cell growth rate when compared with G2 (p < 0.01). Moreover, G4 exhibited a similar cell growth rate as G1 throughout the entire experiment (p > 0.05). These findings indicate that LPT with 5 J/cm2 can enhance the growth of SHEDs during situations of nutritional deficiency. Therefore, LPT could be a valuable adjunct treatment in tissue engineering when using stem cells derived from the dental pulp of primary teeth.
Assuntos
Humanos , Animais , Bovinos , Células-Tronco/efeitos da radiação , Dente Decíduo/citologia , Terapia com Luz de Baixa Intensidade/métodos , Polpa Dentária/citologia , Desnutrição , Radiometria , Fatores de Tempo , Dente Decíduo/efeitos da radiação , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Reprodutibilidade dos Testes , Análise de Variância , Meios de Cultura , Engenharia Tecidual , Polpa Dentária/efeitos da radiação , Proliferação de Células/efeitos da radiaçãoRESUMO
This research analyzed the quality of resin-based sealer adaptation after intracanal laser irradiation. Extracted teeth (n = 168) were root canal treated and divided into four groups, according to dentin surface treatment: no laser; Nd:YAG laser (1.5 W, 100 mJ, 15 Hz); diode laser (2.5 W in CW), and Er:YAG laser (1 W, 100 mJ, 10 Hz). The teeth were divided into four subgroups according to the sealer used: AH Plus, EndoREZ, Epiphany, and EpiphanySE. For testing the sealing after root canal obturation, the penetration of silver nitrate solution was measured, whereas to evaluate the adaptation and penetration of the sealer into the dentin, environmental scanning electron microscopy (ESEM) was used. The ESEM images were analyzed using a four-grade criteria score by three evaluators. The inter-examiner agreement was confirmed by Kappa test and the scores statistically compared by the Kruskal-Wallis' test (p < 0.05). Both adaptation and sealer penetration in root canals were not affected by the laser irradiation. Nd:YAG and diode laser decreased the tracer penetration for AH Plus, whereas EndoREZ and EpiphanySE performances were affected by Nd:YAG irradiation (p < 0.05). It can be concluded that intracanal laser irradiation can be used as an adjunct in endodontic treatment; however, the use of hydrophilic resin sealers should be avoided when root canals were irradiated with Nd:YAG laser.
Assuntos
Cavidade Pulpar/efeitos da radiação , Dentina , Lasers de Estado Sólido/uso terapêutico , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Nitrato de Prata/uso terapêutico , Cavidade Pulpar/diagnóstico por imagem , Dentina/diagnóstico por imagem , Resinas Epóxi , Humanos , Terapia a Laser/métodos , Microscopia Eletrônica de Varredura , Estatísticas não ParamétricasRESUMO
Root canal preparation is an important step in endodontic treatment. The anatomical complexity of the middle third of the root compromises the effective cleaning of this area. Thus, advances have been made in instrumentation techniques and instruments for this purpose. The aim of this study was to evaluate the effects of three different instrumentation systems on the enlargement of the middle thirds of root canals in mandibular incisors. The preparation methods used were the reciprocating systems Reciproc (Group I) and WaveOne (Group II) and the oscillatory system Tilos (Group III). Comparisons were made by three-dimensional image reconstruction with cone-beam computed tomography before and after instrumentation. Changes in area, perimeter, centering ability, and pattern of preparation were analyzed. The results were subjected to ANOVA complemented by the Tukey’s test. Changes in area, perimeter, and tendency of transportation showed similar results among groups. The transportation index of the Tilos system was significantly lower than that of the other groups. Qualitative analysis of the preparation pattern showed that the Tilos system had a more uniform preparation, although Reciproc and WaveOne preparations appeared more rounded, incompatible with the original canal anatomy. There was similarity in the systems’ performance on flattened areas, although the Tilos system presented a better pattern of root canal preparation and a lower index of transportation.
Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar , Desenho de Equipamento , Preparo de Canal Radicular/instrumentação , Análise de Variância , Instrumentos Odontológicos , Imageamento Tridimensional , Teste de Materiais , Níquel , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Estatísticas não Paramétricas , Fatores de Tempo , TitânioRESUMO
The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.
Assuntos
Lâmpadas de Polimerização Dentária , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/química , Equipamentos Odontológicos , Teste de Materiais , Polimerização/efeitos da radiação , Doses de Radiação , Equipamentos e Provisões para Radiação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de TempoRESUMO
The aim of this study was to evaluate the penetration of a resin/polyester polymer-based material (Resilon Real Seal; SybronEndo Corp., Orange, USA) into simulated lateral canals, and the quality of obturations by different techniques. A total of 30 standardized simulated canals were divided into three groups according to the technique of obturation used: MS (McSpadden), SB (SystemB/Obtura II), and LC (Lateral Condensation). To analyze the penetration of the filling material, the simulated canals were digitalized and the images were analyzed using the Leica QWIN Pro v2.3 software. The data of the middle and apical thirds were separately submitted to analysis of variance (ANOVA), followed by the Tukey’s test for the comparison of the techniques. Results showed a significant difference (p < 0.05) between groups (LC < SB) in the middle third, and a significant difference (p < 0.05) between groups (LC < SB and MS < SB) in the apical third. To analyze the quality of the obturations, the canals were radiographed and evaluated by three examiners. The Kappa test on interexaminer agreement and the nonparametric Kruskal-Wallis test indicated no significant difference between filling techniques. It was concluded that Resilon achieves greater levels of penetration when associated with thermoplastic obturation techniques.
Assuntos
Cavidade Pulpar/efeitos dos fármacos , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Análise de Variância , Cavidade Pulpar , Guta-Percha/química , Teste de Materiais , Poliésteres/química , Estatísticas não ParamétricasRESUMO
O tratamento endodôntico em dentes decíduos decorrente de lesões cariosas ou traumáticas com envolvimento pulpar muitas vezes é necessário na Clínica Odontopediátrica. Entretanto, nota-se que a qualidade da técnica endodôntica em dentes decíduos muitas vezes é deixada de lado, justificada pelo difícil comportamento das crianças e pelas características anatômicas internas dos dentes decíduos. Assim, seria interessante resgatar e agregar novos conceitos à endodontia de dentes decíduos para facilitar o dia-a-dia clínico e otimizar o tratamento. Este trabalho teve como objetivo descrever um caso clínico de uma paciente atendida na Clinica de Graduação de Odontopediatria da Uniararas, onde se realizou o tratamento endodôntico no incisivo central superior decíduo esquerdo, através de uma nova proposta que tem por objetivo melhorar a qualidade da técnica endodôntica em dentes decíduos utilizando localizadores apicais eletrônicos e um sistema de instrumentação mecanizado. Concluiu-se que a utilização de novas tecnologias apresentou-se como uma alternativa viável no tratamento endodôntico do incisivo decíduo relatado, auxiliando e alcançando um resultado satisfatório em relação ao preparo mecânico do conduto e ao seu preenchimento com o material obturador. Mais estudos futuros deveriam ser realizados para avaliar a utilização dessas novas tecnologias no tratamento endodôntico de dentes decíduos.
The endodontic treatment in primary teeth due to caries or trauma with pulp involvement is often necessary in Pediatric Dentistry. However, it has been observed that the technical quality of endodontic primary teeth is often left out justified by the difficult behavior of children and the internal anatomical features of the deciduous teeth. Thus, it would be interesting to recover and add new concepts to endodontics in primary teeth to facilitate the day-to-day clinical and optimized treatment. The aim of this study was to describe a clinical case of a patient treated in the Pediatric Dentistry Clinic of the Graduate UNIARARAS, where they performed endodontic treatment in deciduous left maxillary central incisor, through a new proposal, which aims to improve the quality of endodontic technique in primary teeth using electronic apex locators, ultrasound, mechanical instrumentation system. It was concluded that the use of new technologies introduced as a viable alternative to endodontic treatment of deciduous incisor reported, aiding and achieving a satisfactory outcome in relation to the mechanical preparation of the canal and fill it with filling material. Further studies should be performed to evaluate the use of these new technologies in endodontic treatment of deciduous teeth.
Assuntos
Humanos , Feminino , Pré-Escolar , Criança , Endodontia/métodos , Odontopediatria , Dente DecíduoRESUMO
The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.
Assuntos
Humanos , Instrumentos Odontológicos , Cavidade Pulpar , Preparo de Canal Radicular/instrumentação , Microtomografia por Raio-X , Ligas Dentárias , Dentina/química , Desenho de Equipamento , Níquel , Distribuição Aleatória , Reprodutibilidade dos Testes , Preparo de Canal Radicular/métodos , Aço Inoxidável , Estatísticas não Paramétricas , Propriedades de Superfície , TitânioRESUMO
Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the RealSeal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the RealSeal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).
Assuntos
Humanos , Infiltração Dentária , Lasers Semicondutores , Materiais Restauradores do Canal Radicular/efeitos da radiação , Dentina/química , Dentina/efeitos da radiação , Resinas Epóxi/química , Resinas Epóxi/efeitos da radiação , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Estatísticas não Paramétricas , Propriedades de SuperfícieRESUMO
OBJECTIVES: The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). STUDY DESIGN: Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of ±1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the χ(2) tests. RESULTS: Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of ±1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. CONCLUSIONS: Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography.
Assuntos
Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Radiografia Dentária Digital , Preparo de Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Dente Pré-Molar/anatomia & histologia , Eletrônica/instrumentação , Desenho de Equipamento , Humanos , Odontometria/estatística & dados numéricos , Radiografia Dentária Digital/estatística & dados numéricosRESUMO
The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5 percent methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student’s t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.
Assuntos
Humanos , Infiltração Dentária/classificação , Cavidade Pulpar/efeitos da radiação , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Materiais Restauradores do Canal Radicular/uso terapêutico , Ápice Dentário/efeitos da radiação , Corantes , Colagem Dentária , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Resinas Epóxi/química , Resinas Epóxi/uso terapêutico , Guta-Percha/química , Guta-Percha/uso terapêutico , Teste de Materiais , Microscopia Eletrônica de Varredura , Azul de Metileno , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Fatores de Tempo , Ápice Dentário/ultraestruturaRESUMO
The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9 percent saline solution and 1 percent sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.
Assuntos
Humanos , Técnicas In Vitro , Odontometria/instrumentação , Irrigantes do Canal Radicular , Preparo de Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Cavidade Pulpar/anatomia & histologia , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de TempoRESUMO
This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP), and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA) and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA). The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP), with a 20º variation of the horizontal angle (GM) and 25º variation of the horizontal angle combined with 15º vertical angle (GMV). Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV) to dissociate maxillary premolar roots in both radiography systems.
Assuntos
Humanos , Dente Pré-Molar , Radiografia Dentária Digital , Raiz Dentária , Análise de Variância , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não ParamétricasRESUMO
The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).
Assuntos
Guta-Percha/química , Obturação do Canal Radicular/métodos , Análise de Variância , Cavidade Pulpar , Temperatura Alta , Teste de Materiais , Estatísticas não Paramétricas , Fatores de TempoRESUMO
OBJECTIVES: This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface). STUDY DESIGN: Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er:YAG laser - 1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd:YAG laser - 2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunn's test. RESULTS: SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. On the other hand, apicectomies carried out with Er:YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd:YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd:YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas. CONCLUSIONS: There were no differences in terms of cut quality between the use of burs and Er:YAG laser or between the 2 surfaces (apical and buccal) treated with Nd:YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated.