Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 278(6): 1879-1883, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33386966

RESUMO

PURPOSE: To evaluate nasal mucociliary clearance (NMC) and hearing loss in patients with pseudoexfoliation (PEX) syndrome. METHODS: The study included 36 patients with PEX syndrome as the study group, and 39 healthy individuals as the control group. The duration of NMC was measured using the saccharine test. Audiometry was applied at 250, 500, 1000, 2000, 4000, 6000 and 8000 Hz frequencies to determine hearing thresholds and prevalence of hearing loss. RESULTS: No statistically significant difference was determined between the groups in respect of age and gender (p = 0.23 and p = 0.36, respectively). In the saccharine test, the mean NMC time was 18.41 ± 8.53 min for the study group and 11.69 ± 4.96 min for the control group. The mean NMC time of study group was significantly longer than that of the controls (p < 0.001). In the comparisons of the two groups in terms of the prevalence of hearing loss, no statistically significant difference was found at any of the evaluated frequencies (p > 0.05, for all). There was also no statically significant difference between groups in relation to hearing thresholds at these frequencies (p > 0.05, for all). CONCLUSION: The NMC time was significantly prolonged in patients with PEX syndrome. This result indicates that nasal mucosa cilia, which have similar elastic and mobile structures as the iris, are damaged in PEX syndrome, which is an infiltrative disease increasing the rigidity of affected tissues. In upper respiratory tract infections of unknown cause, PEX syndrome should be considered among the etiological factors. In this study, no significant relationship was detected between PEX and hearing loss.


Assuntos
Síndrome de Exfoliação , Perda Auditiva , Audiometria , Síndrome de Exfoliação/complicações , Audição , Humanos , Depuração Mucociliar
2.
J Ocul Pharmacol Ther ; 37(1): 45-51, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33147089

RESUMO

Purpose: To detect the presence of urotensin-2 (U-II) in the aqueous humor and evaluate the relationship between aqueous humor level and systemic diseases and pupil size. Methods: The study included 88 patients who underwent cataract surgery. Those with a pupil diameter (PD) of up to 4 mm were considered to have small dilation, those with 4-7 mm of dilatation were considered to have moderate dilation, and those with a PD of more than 7 mm considered to have large dilation. Patients with HT (hypertension) were classified as group 1, those with DM (diabetes mellitus) as group 2, and those with HT+DM as group 3, and those without any systemic disease as group 4. The U-II levels in humor aqueous samples taken from anterior chamber were measured. Results: When compared with the control group, it was observed that the level of U-II in the aqueous humor of the HT, DM, and DM+HT groups was significantly higher (P < 0.05). At the same time, when we compared the DM+HT group with the other groups, the level of U-II in the aqueous humor was significantly higher compared to the group with DM (P < 0.05). The U-II levels of the aqueous humor were higher in the patients with small pupils compared to the remaining groups (P < 0.005). Conclusion: U-II may play a role in small pupil pathophysiology. In addition, it was determined that patients with HT and/or diabetes had higher U-II levels in the aqueous humor than healthy individuals.


Assuntos
Humor Aquoso/química , Diabetes Mellitus/diagnóstico , Miose/diagnóstico , Urotensinas/análise , Idoso , Catarata , Estudos Transversais , Diabetes Mellitus/cirurgia , Feminino , Humanos , Masculino , Miose/cirurgia , Estudos Prospectivos
3.
Int Ophthalmol ; 39(12): 2905-2911, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31410634

RESUMO

PURPOSE: To evaluate the effects of chronic smoking on tear function tests and meibomian glands. METHODS: This prospective study included 40 volunteers with a long-term (> 5 years) cigarette smoking history (study group) and 43 non-smoking healthy individuals (control group). The symptoms of all the participants were scored using the Ocular Surface Disease Index (OSDI) questionnaire, and a detailed ophthalmological examination was performed including the tear breakup time (TBUT) and Schirmer test (with anaesthesia). The upper and lower lid meibomian glands were evaluated with meibography using the Sirius anterior segment analysis system (Sirius, CSO, Florence, Italy). RESULTS: The groups showed homogenous distribution in respect of age and gender (p > 0.05). The patients in the study group were determined with 22.59 ± 17.25 packet/year cigarette usage. The mean OSDI score was 36.67 ± 21.47 in the study group and 31.65 ± 15.60 in the control group (p = 0.64). The TBUT and Schirmer test values were determined as 9.65 ± 6.14 s and 8.90 ± 4.95 mm, respectively, in the study group and 11.23 ± 5.94 s and 13.08 ± 8.61 mm in the control group (p > 0.05). In the upper lid meibography, loss of 24.68 ± 16.54% was determined in the study group and 17.87 ± 7.06% in the control group (p = 0.01). No statistically significant difference was determined between the groups in respect of the lower lid meibomian gland loss: study group 14.70 ± 8.49% versus control group 12.48 ± 6.44% (p = 0.20). CONCLUSIONS: Smoking results in meibomian gland damage which may be a risk factor for dry eye. In cases of ocular surface disorders related to chronic smoking, meibomian gland damage should be taken into consideration.


Assuntos
Glândulas Tarsais/fisiopatologia , Fumar/efeitos adversos , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Lágrimas/fisiologia
4.
Clin Ophthalmol ; 10: 961-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27307699

RESUMO

PURPOSE: The aim of the study was to analyze the effects of uneventful phacoemulsification surgery on choroidal thickness (CT) using spectral domain optical coherence tomography (SD-OCT). METHODS: In this prospective study, 38 eyes of 38 patients having phacoemulsification surgery were included. All patients underwent detailed ophthalmologic examination, including preoperative axial length (AXL) measurement with optical biometry and intraocular pressure (IOP) measurement preoperatively and 1 month postoperatively. The CT was measured perpendicularly at the fovea and 1.5 mm temporal, 3.0 mm temporal, 1.5 mm nasal, and 3.0 mm nasal using SD-OCT preoperatively and 1 month postoperatively. Changes in the CT after surgery and correlation of this change with age, AXL, preoperative IOP, and IOP change were evaluated. RESULTS: There was a statistically significant increase in the CT at all regions evaluated. This increment was more prominent in the nasal and subfoveal regions. The IOP decreased significantly 1 month after surgery (16.14±4.94 mmHg vs 13.91±4.86 mmHg; P<0.001). The change in IOP was correlated with the CT changes at all regions, whereas age, AXL, and preoperative IOP had no significant correlations with the changes in CT. CONCLUSION: Phacoemulsification surgery may cause significant increase in CT, which is correlated with surgery-induced IOP change in the short term. Long-term follow-up of eyes having phacoemulsification surgery may provide further insight into the effects of cataract surgery on the choroid.

5.
J Cataract Refract Surg ; 40(2): 269-75, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24368115

RESUMO

PURPOSE: To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes. SETTING: Bozok University Faculty of Medicine, Yozgat, Turkey. DESIGN: Evaluation of diagnostic test. METHODS: In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained using the Scheimpflug-Placido topographer. Repeatability of the corneal aberrometric data using a 7th-order Zernike expansion (6.0 mm pupil) and central corneal power (3.0 mm zone) in the anterior and posterior corneal surfaces were analyzed. The within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC) were calculated. RESULTS: For all modal pairs, the Sw was 0.08 µm or less for anterior and posterior corneal aberrations in both groups. The ICC of the anterior corneal surface ranged from 0.607 (pentafoil) to 0.988 (primary coma) in keratoconus eyes (n = 41) and from 0.568 (quadrifoil) to 0.856 (primary coma) in normal eyes (n = 30). The ICCs for posterior corneal surface aberrometry were 0.656 to 0.873 and 0.592 to 0.824, respectively. For anterior and posterior corneal curvatures, the Sw was 0.12 or lower and the ICC values were more than 0.93 in all cases except the posterior corneal surface reading at the 3.0 mm corneal area in keratoconus eyes (ICC 0.875). CONCLUSIONS: The intraexaminer repeatability of most anterior corneal aberrations with the Scheimpflug-Placido system was moderate to high in normal eyes and keratoconus eyes. The system showed moderate repeatability for the posterior corneal surface. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Aberrometria/métodos , Topografia da Córnea/instrumentação , Aberrações de Frente de Onda da Córnea/diagnóstico , Ceratocone/diagnóstico , Adulto , Topografia da Córnea/métodos , Voluntários Saudáveis , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA