Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 100007, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211509

RESUMO

"Cases of SCMR" is a case series on the SCMR website (https://www.scmr.org) for the purpose of education. The cases reflect the clinical presentation, and the use of cardiovascular magnetic resonance (CMR) in the diagnosis and management of cardiovascular disease. The 2022 digital collection of cases are presented in this manuscript.


Assuntos
Doenças Cardiovasculares , Valor Preditivo dos Testes , Humanos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Pessoa de Meia-Idade , Feminino , Masculino , Idoso , Imageamento por Ressonância Magnética , Adulto , Prognóstico , Adulto Jovem
2.
Pediatr Cardiol ; 43(6): 1365-1372, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35316357

RESUMO

Leftward posterior deviation of the atrial septum primum (LDSP) has been reported in up to 64% of patients with hypoplastic left heart syndrome (HLHS) but there are no published data on its impact on neonatal outcomes. We reviewed the prevalence of LDSP and its correlation with neonatal outcomes in our institution. This was a single-center retrospective study of neonates with HLHS from 2001 to 2019. Echocardiograms were reviewed and the presence or absence of LDSP was noted. To quantify the degree of deviation in patients with LDSP, a new measurement, the deviation index (DI) was calculated using both the subcostal long and short-axis views. Of ninety-four patients with HLHS, fifty-seven (61%) patients were noted to have LDSP. There was no statistically significant difference in gestational age (GA), birth weight (BW), or mortality between patients with and without LDSP. Patients with LDSP had an increased incidence of unplanned reoperation (p < 0.01), post-operative cardiac catheterization (p < 0.05), and post-operative infection (p < 0.05). After correction for GA, BW, HLHS subtype, and type of surgery, LDSP predicted reoperation (OR = 3.6, p < 0.01), catheterization (OR = 2.7, p = 0.05), and infection (OR = 3.4, p < 0.05). Higher degree of deviation predicted reoperation (DI > 0.17), catheterization (DI > 0.07), and infection (DI > 0.12). There was excellent inter-observer reproducibility of the DI (ICCabsolute-agreement = 0.82, ICCconsistency = 0.90). Patients with LDSP have a higher prevalence of post-operative morbidity. The degree of deviation was found to be predictive of post-operative complications. Pre-operative echocardiographic evaluation of LDSP in patients with HLHS may be helpful in risk stratification and counseling.


Assuntos
Septo Interatrial , Síndrome do Coração Esquerdo Hipoplásico , Septo Interatrial/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Recém-Nascido , Morbidade , Complicações Pós-Operatórias/epidemiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
JACC Cardiovasc Imaging ; 15(8): 1391-1405, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34419404

RESUMO

BACKGROUND: After diagnosis of a cardiac mass, clinicians must weigh the benefits and risks of ascertaining a tissue diagnosis. Limited data are available on the accuracy of previously developed noninvasive pediatric cardiac magnetic resonance (CMR)-based diagnostic criteria. OBJECTIVES: The goals of this study were to: 1) evaluate the CMR characteristics of pediatric cardiac masses from a large international cohort; 2) test the accuracy of previously developed CMR-based diagnostic criteria; and 3) expand diagnostic criteria using new information. METHODS: CMR studies (children 0-18 years of age) with confirmatory histological and/or genetic diagnosis were analyzed by 2 reviewers, without knowledge of prior diagnosis. Diagnostic accuracy was graded as: 1) single correct diagnosis; 2) correct diagnosis among a differential; or 3) incorrect diagnosis. RESULTS: Of 213 cases, 174 (82%) had diagnoses that were represented in the previously published diagnostic criteria. In 70% of 174 cases, both reviewers achieved a single correct diagnosis (94% of fibromas, 71% of rhabdomyomas, and 50% of myxomas). When ≤2 differential diagnoses were included, both reviewers reached a correct diagnosis in 86% of cases. Of 29 malignant tumors, both reviewers indicated malignancy as a single diagnosis in 52% of cases. Including ≤2 differential diagnoses, both reviewers indicated malignancy in 83% of cases. Of 6 CMR sequences examined, acquisition of first-pass perfusion and late gadolinium enhancement were independently associated with a higher likelihood of a single correct diagnosis. CONCLUSIONS: CMR of cardiac masses in children leads to an accurate diagnosis in most cases. A comprehensive imaging protocol is associated with higher diagnostic accuracy.


Assuntos
Meios de Contraste , Neoplasias Cardíacas , Criança , Gadolínio , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
4.
Pediatr Cardiol ; 38(1): 115-122, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27833994

RESUMO

In infants with a single right ventricle (RV), stage I palliation involves aortic reconstruction, systemic-to-pulmonary shunt placement, and atrial septectomy. Many require re-intervention for residual coarctation of the aorta (CoA). Doppler echocardiography can detect residual CoA in most infants, but its ability to predict severity has not been studied. This study compares gradients from Doppler interrogation to those from cardiac catheterization in infants with residual CoA. We performed a retrospective study of infants after stage I palliation from 2000 to 2014. Infants with an echocardiogram and catheterization before the second-stage palliative surgery were included. Infants with an echocardiogram >30 days before catheterization were excluded. Doppler-derived gradients were compared to catheterization-derived gradients. Echocardiographic assessment of tricuspid valve (TV) and RV function were recorded. The cohort included 95 infants, and thirty-three (35%) had CoA. Doppler-derived and catheterization-derived gradients correlated weakly in infants with CoA (r = 0.37, p = 0.036) and without CoA (r = 0.35, p = 0.005). Among infants with CoA, 17/33 had none or trivial tricuspid regurgitation (TR) and normal RV function, and Doppler-derived gradients correlated with catheterization gradients in this group (r = 0.71, p = 0.001). In 16/33 infants with ≥moderate TR or RV dysfunction, gradients did not correlate (r = -0.003, p = 0.992). After a stage I palliation in infants with single RV and CoA, Doppler-derived gradients poorly predicted the severity of CoA. Infants with normal TV or RV function had Doppler-derived gradients more predictive of catheterization-derived gradients. Doppler-derived gradients have limited utility in determining the severity of CoA after a stage I palliation.


Assuntos
Coartação Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler/métodos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Cuidados Paliativos/métodos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Curva ROC , Estudos Retrospectivos , Disfunção Ventricular Direita/fisiopatologia
5.
Congenit Heart Dis ; 11(6): 570-577, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26931510

RESUMO

OBJECTIVE: Determine the accuracy of echocardiography to diagnose coronary anatomy in transposition of the great arteries and to evaluate the effect of accuracy on surgical outcomes and changes in accuracy over time. DESIGN: Retrospective chart review of neonates admitted February 1999 to March 2013 with transposition. Coronary pattern from the preoperative echocardiogram and operative reports were collected and compared with determine diagnostic accuracy. Coronary patterns were further confirmed by intraoperative images taken during surgery. SETTING: Tertiary care children's hospital. PATIENTS: Neonates with transposition of the great arteries and planned arterial switch operation with an echo and operative report or image describing the coronaries. INTERVENTIONS: Not applicable. OUTCOME MEASURES: Accuracy of echocardiography to diagnose coronary anatomy in transposition, and to identify factors related to correct diagnosis. RESULTS: One hundred forty-two patients met inclusion criteria with 122 correctly diagnosed, 16 incorrect, and 4 inconclusive. Accuracy was 86%, with 95% accuracy in patients with typical coronary patterns, 85% with the most common variant (left coronary from the leftward sinus and right and circumflex from the rightward sinus), and 61% with less common patterns. Typical and common variants were more likely to be correct than atypical patterns (P < .001). Cases with ventricular septal defect were more likely to have correctly diagnosed coronaries than with an intact ventricular septum (94% vs. 79%, P = .01). There was no change in accuracy over time (P > .05). There was no difference in duration of cardiopulmonary bypass, cross-clamp times, length of stay, or postoperative stay between the correct and incorrectly diagnosed groups (P > .05). CONCLUSIONS: In our center, accuracy of echocardiographic imaging of the coronary arteries in transposition was 86% without improvement over time, and perioperative outcomes were not affected by diagnostic accuracy. Further invasive imaging may not be necessary to determine the coronary pattern in this lesion.


Assuntos
Transposição das Grandes Artérias , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Feminino , Hospitais Pediátricos , Humanos , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA