Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Circ J ; 87(11): 1635-1642, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37197976

RESUMO

BACKGROUND: Grafting the right gastroepiploic artery (GEA) to the right coronary artery (RCA) is effective, but preoperative evaluation of arterial conduit availability has not been established. By comparing the midterm graft results, we aimed to assess the efficacy of preoperative evaluation of the GEA using computed tomography (CT).Methods and Results: We retrospectively examined patients who underwent isolated coronary artery bypass grafting surgery between April 2010 and December 2020, and those whose GEA was grafted to the RCA were selected: 55 patients were included in the study analysis. Postoperative evaluations were performed during the early phase, 1 year postoperatively, and at follow-up evaluations. The outer diameter of the proximal GEA was compared with the midterm graft patency grade on CT and patients were classified as Functional (Grade A) or Dysfunctional (Grades O or B). The proximal GEA outer diameters were significantly different between the Functional and Dysfunctional groups (P<0.001). Furthermore, multivariate Cox regression analysis revealed that this diameter was an independent predictor of graft functionality (P<0.001). Patients with outer proximal diameters larger than the cutoff value had superior graft results at 3 years postoperatively. The rate of freedom from a dysfunctional graft at 3 years postoperatively was 95.5% and 45.5% for the Larger and Smaller diameter subgroups, respectively (P<0.001). CONCLUSIONS: Preoperative evaluation of the outer diameter of the proximal GEA, excluding calcified GEA, using CT is a minimally invasive and useful method, and may improve midterm results of in-situ GEA grafting, even in severe stenotic lesions.


Assuntos
Artéria Gastroepiploica , Humanos , Artéria Gastroepiploica/diagnóstico por imagem , Estudos Retrospectivos , Ponte de Artéria Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Tomografia Computadorizada por Raios X , Grau de Desobstrução Vascular
2.
J Heart Lung Transplant ; 42(6): 707-715, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36931988

RESUMO

BACKGROUND: For normothermic ex vivo heart perfusion (EVHP), a resting mode and working mode have been proposed. We newly developed a left ventricular assist device (LVAD) mode that supports heart contraction by co-pulse synchronized LVAD. METHODS: Following resting mode during time 0 to 1 hour, pig hearts (n = 18) were perfused in either resting, working, or LVAD mode during time 1 to 5 hour, and then myocardial function was evaluated in working mode at 6 hour. The preservation ratio was defined as the myocardial mechanical function at 330 minute divided by the function at 75 minute. In LVAD mode, LVAD unloaded the pressure and the volume in the left ventricle in the systolic phase. RESULTS: The LVAD group was significantly associated with higher preservation ratios in cardiac output (resting, 33 ± 3; working, 35 ± 5; LVAD, 76% ± 5%; p < 0.001), stroke work, dP/dt maximum, and dP/dt minimum compared with the other groups. Glucose consumption was significantly reduced in the resting group. The LVAD group was significantly associated with higher myocardial oxygen consumption (resting, 2.2 ± 0.3; working; 4.6 ± 0.5; LVAD, 6.1 ± 0.5 mL O2/min/100 g, p < 0.001) and higher adenosine triphosphate (ATP) levels (resting, 1.1 ± 0.1; working, 0.7 ± 0.1; LVAD, 1.6 ± 0.2 µmol/g, p = 0.001) compared with the others. CONCLUSION: These data suggest that myocardial mechanical function was better preserved in LVAD mode than in resting and working modes. Although our data suggested similar glycolysis activity in the LVAD and working groups, the higher final ATP in the LVAD group might be explained by reduced external work in LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Suínos , Animais , Ventrículos do Coração , Função Ventricular Esquerda , Coração , Perfusão
3.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951516

RESUMO

OBJECTIVES: This study aimed to evaluate the outcomes of tricuspid annuloplasty with/without additional edge-to-edge plications in patients with functional tricuspid regurgitation (TR) and to clarify the impact of tethering on surgical outcomes. METHODS: This retrospective observational study included patients with moderate or greater functional TR who underwent initial tricuspid valve repair between January 2008 and December 2021. The patients were divided into 2 groups based on whether they had tethering (preoperative tethering area ≥0.75 cm2). All patients underwent annuloplasty, and edge-to-edge plications were added at the regurgitant leakage site identified by saline tests. The surgical outcomes of each group and the effect of tethering on recurrent moderate or greater TR were evaluated. RESULTS: One hundred and thirty-three patients were included in this study. During the follow-up period of 55.3 (standard deviation: 44.9) months, the 5-year survival rates were 78.4% in patients without tethering and 76.1% in patients with tethering (P = 0.78). The 5-year cumulative incidence rates of readmission for heart failure and recurrent TR were 10.8% and 1.3% in patients without tethering and 23.0% and 29.5% in patients with tethering, respectively (P = 0.12 and <0.001). Multivariable analyses revealed that the preoperative and predischarge tethering areas predicted recurrent TR. A large tethering area remained postoperatively in patients with tethering. CONCLUSIONS: In patients without tethering, annuloplasty and additional edge-to-edge plications are effective in avoiding recurrent TR with satisfactory midterm clinical outcomes. However, in patients with tethering, these procedures resulted in residual tethering, which could be leading to recurrent TR.


Assuntos
Anuloplastia da Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/cirurgia , Valva Mitral/cirurgia , Valva Aórtica , Estudos Retrospectivos , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos
4.
Gen Thorac Cardiovasc Surg ; 71(11): 665-673, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36964855

RESUMO

BACKGROUND: We developed a new sternal fixation device, Super FIXSORB WAVE®, a corrugated plate made of u-HA/PLLA, to improve sternal stability after sternotomy. This present study aimed to evaluate the new device clinically. METHODS: This prospective, single-blinded, multicenter trial randomized 69 patients to either wire cerclage only (group C, n = 30) or wire cerclage plus Super FIXSORB WAVE® (group W, n = 39). The primary endpoint was a degree of sternal displacement at six months. Displacement of the sternal halves in the anteroposterior and lateral directions was measured using computed tomography horizontal section images at the third costal and fourth intercostal levels. The secondary endpoints were sternal pain and quality-of-life over 6 months. RESULTS: Group W showed significantly reduced sternal anteroposterior displacement at both the third costal (0 [0-1.9] mm vs. 1.1 [0-2.1] mm; P = 0.014) and fourth intercostal (0 [0-1.0] mm) vs. 1.0 [0-1.8] mm; P = 0.015) levels than group C. In group W, lateral displacement was suppressed without a significant increase from 2 weeks to 6 months, while it increased in group C. There was no significant difference in postoperative sternal pain and quality-of-life between the two groups. No adverse events, such as infection, inflammation, or foreign body reaction, were observed with this device. CONCLUSIONS: Using Super FIXSORB WAVE®, sternal displacement was significantly suppressed in both the anteroposterior and lateral directions. The use of this device results in safe and easy sternal reinforcement without any adverse events, and sternal healing can be accelerated. CLINICAL TRIAL REGISTRY NUMBER: This study was registered in the Japan Registry of Clinical Trials (February 21, 2019; jRCTs032180146).

5.
ESC Heart Fail ; 10(2): 1426-1430, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36401586

RESUMO

A 44-year-old woman who was quarantined for 5 days after the diagnosis of coronavirus disease of 2019 (COVID-19) was transferred to our hospital with the complaint of chest pain. The patient was unvaccinated. Electrocardiography revealed ST elevation in the lateral leads. Echocardiographic biventricular dysfunction with oedematous wall thickening was identified. Cardiac enzyme levels were elevated; however, C-reactive protein (CRP) levels, and the coronary angiogram were normal. The patient required mechanical circulatory support to stabilize haemodynamics and was treated with remdesivir, baricitinib, and intravenous methylprednisolone. She recovered after 13 days of mechanical support. Serial cardiac magnetic resonance imaging revealed acute myocardial oedema and subsequent fibrosis. An endomyocardial biopsy on admission showed mild interstitial inflammatory infiltrates with endomyocardial fibrous thickening and mild interstitial fibrosis of the myocardium. Normal CRP levels suggested minor involvement of interleukin (IL)-6, supporting the efficacy of baricitinib.


Assuntos
COVID-19 , Miocardite , Feminino , Humanos , Adulto , Miocardite/complicações , Miocardite/diagnóstico , Proteína C-Reativa , COVID-19/complicações , Seguimentos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Fibrose
6.
J Cardiol ; 81(1): 111-116, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36229301

RESUMO

BACKGROUND: As cardiac implantable electronic devices, such as pacemakers, cardioverter defibrillators, and cardiac resynchronization therapies, have become more popular, device extraction has become more frequent. At our institution, individual treatment strategies are discussed at a heart team meeting. Transvenous lead extraction (TVLE) is a first-line treatment; however, surgical lead extraction (SLE) is sometimes selected as a primary choice to provide optimal treatment and maintain the medical safety policy. This study aimed to investigate the validity of this heart team decision-making. METHODS: From 2013 to 2021, 384 consecutive patients underwent lead extraction at our institution. RESULTS: SLE was proposed as the primary intervention for 21 patients who had high risk of bleeding, difficult TVLE conditions, large vegetations, and other concomitant cardiac diseases. Of the 363 TVLE patients, 10 patients required surgical intervention; 5 had TVLE difficulty followed by SLE and 5 had excessive bleeding. SLE was performed in 26 patients, 19 of whom required valve surgery, and 8 required plication of the great veins. In 4 of the 17 hybrid procedures with SLE and TVLE, excessive bleeding occurred due to laceration of the superior vena cava and innominate vein. Operative mortality was not observed in SLE patients but was observed in 1 of the 4 TVLE patients who required emergent open-chest hemostasis. CONCLUSIONS: The heart team discussion was essential to provide optimal treatment and maintain medical safety policies for each patient. SLE should be selected for patients with high risk of TVLE or other cardiac complications such as tricuspid valve incompetence.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Eletrônica , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Superior
7.
Gen Thorac Cardiovasc Surg ; 71(2): 98-103, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35972715

RESUMO

BACKGROUND: A reliable sternal fixation is one of the most basic parts of cardiac surgery requiring sternotomy for preventing wound complications and promoting early recovery. Although various products have been released to the markets, the characteristics of each device are still unclear. METHODS: A simulation study was conducted to compare the properties of two sternal fixation device: a commonly used monofilament stainless-steel wire and a newly designed cable comprised of several titanium alloys strands. Sternum models made of monomer casting nylon were tied with each material and displaced in longitudinal, antero-posterior, and horizontal directions. Resistance against each directional external force was measured and compared. RESULTS: The titanium cable showed a higher resistance to every directional displacement since slight deviations and a twofold higher maximum strength than the stainless wire. CONCLUSION: An in vitro simulation study revealed the titanium cable system provide stronger sternum fixation than stainless-steel wire.


Assuntos
Esterno , Titânio , Humanos , Esterno/cirurgia , Esternotomia/efeitos adversos , Fios Ortopédicos , Aço
8.
Artigo em Inglês | MEDLINE | ID: mdl-36315071

RESUMO

We describe a case of aortic repair using bovine pericardium for a pseudoaneurysm of a dissecting abdominal aorta. A 71-year-old man had undergone several aortic replacement surgeries for type B aortic dissection. He developed paraparesis after thoraco-abdominal aortic surgery and recovered. After 3 years, the scheduled computed tomography scan showed a pseudoaneurysm of the dissecting abdominal aorta. Because he was at high risk of spinal cord ischaemia, aortic repair using bovine pericardium was performed, and all lumbar arteries were preserved. During the 12-month follow-up, he was asymptomatic, and computed tomography scans showed no dilation of the aorta.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Dissecção Aórtica , Masculino , Bovinos , Animais , Humanos , Idoso , Aneurisma da Aorta Torácica/cirurgia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Pericárdio , Resultado do Tratamento
9.
Artigo em Inglês | MEDLINE | ID: mdl-36130272

RESUMO

OBJECTIVES: This study aimed to evaluate the outcomes of the patients who underwent restrictive annuloplasty (RA) plus papillary muscle relocation anteriorly (PMR-A) with the risk factors in mitral valve repair for functional mitral regurgitation (FMR). METHODS: Eighty-six patients underwent mitral valve repair with RA for FMR. Thirty-five of them received additional bilateral papillary muscle relocation for severe leaflet tethering. The papillary muscles were relocated posteriorly (PMR-P) early in the study. Then, in the later period, the technique was modified to PMR-A, in which the papillary muscles were relocated anteriorly for 24 cases. The survival of the patients undergoing RA + PMR-A was examined retrospectively, adjusting for differences in patient background. RESULTS: Twenty-three deaths were observed during the follow-up period out of the 86 cases. Independent preoperative risk factors for survival were left ventricular ejection fraction, patient age and B-type natriuretic peptide (BNP) level. Among the patients with BNP <1000 pg/ml, 5-year survival after RA plus PMR-A was 84.7%, while RA alone was 78.6% and RA + PMR-P 57.1%. Cox proportional hazards regression adjusted for the preoperative risk factors showed a significantly higher hazard ratio of RA + PMR-P to RA + PMR-A (12.77, P = 0.011), while the hazard ratio of RA alone to RA + PMR-A was not significantly different. Furthermore, reverse remodelling of the left ventricle was observed for 3 years only in RA + PMR-A. CONCLUSIONS: Long-term survival for patients who underwent RA plus bilateral PMR-A was promising. Patients with significantly higher BNP had lower survival after valve repair for FMR.


Assuntos
Músculos Papilares , Função Ventricular Esquerda , Humanos , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Volume Sistólico , Estudos Retrospectivos
10.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35293573

RESUMO

OBJECTIVES: The goal of this study was to evaluate the outcomes of patients with subvalvular procedures for functional tricuspid regurgitation (TR) with severe leaflet tethering. METHODS: Of 175 patients who had tricuspid valve surgery between June 2016 and June 2021, a total of 17 patients with functional TR with a preoperative tethering height ≥8 mm underwent subvalvular procedures (annular repositioning [An-Rep]) to reduce septal leaflet tethering, papillary muscle relocation to reduce anterior leaflet tethering, and/or papillary muscle bundling [PMB] to reduce anterior and posterior leaflet tethering along with ring annuloplasty at our institution. A single subvalvular procedure was performed in 9 patients (An-Rep in 5 patients, PMB in 4 patients; group S), and a combination of subvalvular procedures was performed in 8 patients (An-Rep and papillary muscle relocation in 5 patients, An-Rep and PMB in 3 patients; group C). RESULTS: Predischarge TR grades and tethering height were significantly improved (3.2 ± 1.3-1.0 ± 0.5, p = 0.001; 9.9 ± 2.5 mm-5.5 ± 2.8 mm, p < 0.001, respectively). An-Rep and PMB significantly reduced the postoperative closing angles of the septal and anterior leaflets, respectively. During the 20.4 ± 19.5-month follow-up period, the rates of freedom from death and moderate TR at 2 years were 41.7% in group S, and 71.4% in group C (p = 0.39), respectively. In group C, TR recurrence was not observed at 2 years postoperatively. CONCLUSIONS: Subvalvular procedures were effective in reducing the predischarge TR grades and tethering height. The combination of subvalvular procedures might be a durable strategy to prevent recurrent TR.


Assuntos
Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Estudos de Viabilidade , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
11.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35293582

RESUMO

OBJECTIVES: There are few reports on the rotational position of the aortic valve relative to the base of the left ventricle, and its influence on valve-sparing aortic root replacement (VSRR) has not been reported. Based on our experience with complications such as right atrial perforation and tricuspid valve injury, we investigated the cause of these complications in terms of morphological variations in the aortic root and its surrounding structures. METHODS: The aortic valve rotation relative to the base of the left ventricle was assessed in 30 patients with tri-leaflet aortic valves who underwent VSRR. The influence of such anatomical variations on surgical procedures was investigated. RESULTS: The aortic valve was positioned normally in 25 patients (83.3%), rotated counterclockwise in 4 (13.3%), and rotated clockwise in 1 patient (3.3%). In patients with a counterclockwise rotated aortic valve, the non-coronary sinus was the largest compared with other sinuses. This aortic valve rotation could be diagnosed by multidetector row computed tomography. In all patients who had difficulty in the external dissection of the right sinus of Valsalva, the aortic valve was counterclockwise rotated and forcible dissection had a risk of right atrial perforation and tricuspid valve injury. CONCLUSIONS: Aortic valve rotation is an element that complicates VSRR. The rotational position of the aortic valve can be diagnosed preoperatively using multidetector row computed tomography and understanding the anatomy of the aortic valve related to rotational position help decide proper surgical decision-making in performing aortic root reconstruction procedure.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Tórax
12.
Gen Thorac Cardiovasc Surg ; 70(8): 694-704, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35138563

RESUMO

OBJECTIVES: This study aimed to evaluate the outcomes of our repair technique using autologous pericardial patches for active infective endocarditis with extensive mitral valve destruction. METHODS: From 2009 through 2016, 12 patients with extensive mitral leaflet destruction due to infective endocarditis underwent mitral valve repair with an autologous pericardial patch. Mid-term clinical outcomes and echocardiographic findings of these patients were retrospectively assessed. RESULTS: The perioperative mortality rate was 8.3% (1/12). Postoperatively, the mitral regurgitation grade was ≤ 1 + in all patients. During 5.0 ± 3.2 years of follow-up, there was no recurrence of infective endocarditis or death. There were no cases of mitral regurgitation grade > + 1 and pressure gradient > 5 mmHg during follow-up among 6 patients who underwent posterior leaflet reconstruction, whereas elevation of the pressure gradient was observed in patients who underwent reconstruction of two areas of the anterior leaflet and survived up till the follow-up phase among 3 patients who underwent anterior leaflet repair. The mitral regurgitation grade worsened and pressure gradient was elevated during the follow-up phase in the 2 patients who underwent bi-leaflet repair, and reoperation was performed. CONCLUSION: Mitral valve reconstruction using autologous pericardial patch is a useful treatment option for extensive mitral valve destruction due to active infective endocarditis. Our clinical data revealed that good mid-term results were obtained for posterior leaflet lesions, while extensive anterior leaflet and bi-leaflet lesion repair did not yield satisfactory results. The indication for surgical repair should be carefully evaluated when an extensive anterior region is involved.


Assuntos
Endocardite Bacteriana , Endocardite , Insuficiência da Valva Mitral , Endocardite/complicações , Endocardite/diagnóstico por imagem , Endocardite/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
13.
J Vasc Surg ; 75(1): 74-80.e2, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34416323

RESUMO

OBJECTIVE: Inflammatory thoracic aortic aneurysms (TAAs) are very rare aortic conditions. Resection and replacement of the inflammatory aorta is the first-line treatment, and thoracic endovascular aortic repair (TEVAR) has recently been reported as a less invasive alternative even for this aortic cohort. In the present study, we reviewed our experience with inflammatory TAAs and assessed the preoperative management, surgical procedures, and outcomes. METHODS: From 2006 to 2019, 21 surgeries were performed for inflammatory TAAs in 17 of 2583 patients (0.7%) who had undergone cardiovascular surgery at our institution. The etiologies were Takayasu's arteritis in 13 patients, giant cell arteritis in 2, antineutrophil cytoplasmic antibody-associated vasculitis in 1, and unknown in 1. The mean follow-up period was 66.2 ± 50.2 months (range, 19-186 months). RESULTS: Three patients had undergone multiple surgeries. The aorta was replaced in 14 patients (ascending aorta in 9, aortic arch in 4, and thoracoabdominal aorta in 1). Three isolated TEVARs were performed in two patients and single-stage hybrid aortic repair (ascending aorta and partial arch replacement combined with zone 0 TEVAR) in four patients for extended arch and descending thoracic aortic aneurysms. Stent grafts were deployed on the native aorta in five of the seven TEVARs. The perioperative inflammation was well-controlled with prednisolone (mean dose, 7.4 ± 9.4 mg) in all patients except for one who had required two surgeries under inflammation-uncontrolled situations. No aorta-related complications, including anastomotic aneurysms and TEVAR-related aortic dissection, developed during the follow-up period, and the 5-year freedom from all-cause death was 92.9%. CONCLUSIONS: The mid-term outcomes of surgery for inflammatory TAAs were acceptable. Although replacement remains the standard procedure for inflammatory TAAs, TEVAR is a less invasive acceptable alternative when the inflammation is properly managed.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/complicações , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Arterite de Células Gigantes/complicações , Arterite de Takayasu/complicações , Adulto , Idoso , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/imunologia , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/terapia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/imunologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/imunologia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Arterite de Células Gigantes/imunologia , Arterite de Células Gigantes/terapia , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Arterite de Takayasu/imunologia , Arterite de Takayasu/terapia , Adulto Jovem
14.
J Endovasc Ther ; 29(2): 204-214, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34581224

RESUMO

PURPOSE: Hybrid aortic arch repair (HAR) has been implemented for extended aortic arch and descending thoracic aortic disease since 2012 in our institution. This study aimed to estimate the early and mid-term efficacy and safety of HAR. MATERIALS AND METHODS: From 2007 to 2019, 56 patients underwent HAR for extended aortic arch disease, and 75 patients underwent total arch replacement (TAR) for arch-limited disease. HAR comprises 3 procedures: replacement of the aorta, reconstruction of all arch vessels, and thoracic endovascular aortic repair (TEVAR) from zone 0 to the descending aorta after cardiopulmonary bypass is off in 1 stage. The type II-1 HAR procedure, in which the ascending aorta and aortic arch distal to the brachiocephalic artery are replaced, was the most frequently selected procedure (40/56 patients). The outcomes of the type II-1 HAR procedure were compared with those of TAR using the Cox regression analysis. RESULTS: The median follow-up period was 36 months. In HAR, the operative mortality, in-hospital mortality, and postoperative permanent neurological deficits were not observed. The paraplegia rate was 1.8%. TEVAR-related complications occurred in 3 patients. Among the patients with non-ruptured atherosclerotic aortic arch aneurysm (31 type II-1 HAR patients and 36 TAR patients, the postoperative respiratory support time in those who underwent type II-1 HAR was quicker than in those who underwent TAR (p<0.01). The rate of 6 year freedom from all-cause death in type II-1 HAR (83.1%) was numerically higher than that in TAR (74.7%), and the rate of 6 year freedom from surgery-related complications in type II-1 HAR (90.3%) was numerically lower than that in TAR (96.9%) due to the occurrence of TEVAR-related complications, and the rate of 6 year freedom from reintervention to the descending thoracic aorta in type II-1 HAR (100%) seemed to be better than that in TAR (83.7%). However, Cox regression analysis did not reveal any statistical difference between the 2 procedures. CONCLUSIONS: HAR, especially the type II-1 procedure, can treat extended aortic arch disease with acceptable survival outcomes. The development of TEVAR technology will further improve the outcomes of HAR in the future.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Humanos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
Surg Case Rep ; 7(1): 175, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34347185

RESUMO

BACKGROUND: Coagulopathy induced by COVID-19 has received much attention. Arterial and venous thrombosis of multiple organs due to COVID-19-related coagulopathy is associated with a poor outcome. CASE PRESENTATION: A 67-year-female was transferred to our hospital in need of intensive care for severe COVID-19 pneumonia. On day 7 after admission, despite the treatments, her respiratory and hemodynamic status deteriorated. Computed tomography revealed massive ascites and free air as well as wall defects of the transverse colon. An emergency laparotomy was undertaken in the intensive-care unit, and 17 cm of the transverse colon was resected. Histopathological findings revealed two perforation sites of 25 and 7 mm in diameter, necrosis of the intestinal mucosa around the perforation sites, and the microcirculatory thrombosis in the mesentery vessels which was suspected of having been induced by COVID-19-related coagulopathy. CONCLUSIONS: The case highlights the risk of intestinal ischemia and perforation induced by COVID-19 coagulopathy. Physicians treating COVID-19 should recognize the risk and evaluate patients carefully.

16.
Acute Med Surg ; 7(1): e612, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33318806

RESUMO

BACKGROUND: Some patients with coronavirus disease 2019 (COVID-19) develop pneumothorax. Tube thoracotomy and bulla resection could generate aerosols and cause virus transmission; the optimal treatment strategy remains unclear. CASE PRESENTATION: A 57-year-old male was transferred as a severe COVID-19 pneumonia case. On the 16th day after admission, the patient's respiratory condition deteriorated, and the chest X-ray revealed the presence of severe right-sided pneumothorax. A chest drain was immediately inserted; however, a significant air leak continued, and severe ventilator settings were required. Thus, veno-venous extracorporeal membrane oxygenation (VV-ECMO) treatment was initiated to allow the lungs to rest. After 10 days of lung-protective ventilation, the patient was weaned from ECMO and the chest drain was removed on the following day with no major comorbidities. CONCLUSION: The combination of ECMO with lung rest strategy could be a treatment option for intractable pneumothorax with COVID-19 to avoid unnecessary surgical procedures and aerosol generation.

17.
Ann Thorac Surg ; 110(5): 1746-1750, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32599035

RESUMO

PURPOSE: We developed a heart positioner, the Tentacles NEO, specifically designed for minimally invasive coronary artery bypass grafting (MICS-CABG). DESCRIPTION: The device has 3 flexible suction tubes, with a suction cup at the tip of each tube. The suction tubes can be detached from the device body, allowing them to be manipulated in any direction through a small incision around the small thoracotomy. When the device displaces the heart, the suction cup moves behind the chest wall and does not crowd the operative field. EVALUATION: Although the sideways suction force of the new device was as strong as that of the original device, Tentacles, the longitudinal and perpendicular force exerted was approximately 80% of the original device. Nevertheless, the new device could safely and favorably displace the heart in a pig model and even during off-pump CABG via sternotomy. During MICS-CABG, the device was able to displace the heart without crowding the operative field. CONCLUSIONS: The new heart positioner, Tentacles NEO, is a useful and practical heart positioner suitable for MICS-CABG.


Assuntos
Ponte de Artéria Coronária/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Animais , Ponte de Artéria Coronária/métodos , Desenho de Equipamento , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Sucção , Suínos
18.
Ann Thorac Surg ; 110(5): e427-e430, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32376353

RESUMO

Takayasu arteritis (TA) occasionally involves the coronary ostium leading to myocardial ischemia. Although surgical coronary ostial angioplasty is desirable for ostial stenosis, the patch materials and long-term results are controversial. We used femoral artery (FA) as a patch material for coronary ostial angioplasty in 3 TA patients. Coronary ostial enlargement with a longitudinal incision followed by rectangular FA patch augmentation was performed to extend the narrowing coronary ostium. In all patients, coronary ostial stenosis was successfully repaired. Ostial angioplasty using an FA patch would be a reasonable surgical strategy to treat coronary ostial stenosis in TA.


Assuntos
Angioplastia/métodos , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Artéria Femoral/transplante , Arterite de Takayasu/cirurgia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Arterite de Takayasu/complicações
19.
Innovations (Phila) ; 15(1): 88-92, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31893953

RESUMO

Robotic assisted aortic valve surgery is still challenging and debatable. We retrospectively reviewed our cases of robotic assisted aortic valve replacement utilizing sutureless aortic valve with following surgical technique: 3 ports, 1 for endoscope and 2 for the robotic arms were inserted in the right chest and da Vinci Si robotic system (Intuitive Surgical, Sunnyvale, CA, USA) was adapted to these ports. Cardiopulmonary bypass was initiated through peripheral cannulations. A vent cannula was placed through the right superior pulmonary vein and a cardioplegia cannula in the ascending aorta. After cardioplegic arrest following aortic cross-clamp, the aortic valve was exposed through a clam shell aortotomy. Valvectomy along with decalcification was performed. Next using 3 guiding sutures the Perceval S valve (LivaNova, London, UK) was parachuted down and deployed. After confirming valve position, the aortotomy was closed. There were no major complications during the procedures and no conversion to sternotomy. Exposure of aortic valve was of high quality. Valvectomy required assistance with long scissors by the bedside surgeon for excision of the severely calcified valve cusps and effective decalcification of annulus. Postoperative convalescence was uncomplicated except for postoperative atrial fibrillation in 1 patient. Robotic assistance in aortic valve procedure enabled excellent exposure of the aortic valve and improved manipulation and suturing of the aortic annulus and aorta. There needs to be improvement of instrumentation for valve debridement and removal of calcium from the annulus. In addition, the sutureless valve technology contributes to the feasibility and the efficacy of this procedure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Próteses Valvulares Cardíacas , Humanos , Masculino , Resultado do Tratamento
20.
Ann Thorac Surg ; 106(1): 52-57, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29510098

RESUMO

BACKGROUND: The right gastroepiploic artery (GEA) is utilized as an excellent in situ arterial graft conduit to right coronary artery territory for coronary artery bypass grafting (CABG). However, there remain great concerns regarding the management of patients with a patent in situ GEA during abdominal surgery following CABG. METHODS: From 1995 to 2016, GEA was used for CABG in 278 patients at our institution. Of the patients, 14 abdominal surgeries were performed for subsequent abdominal diseases in 11 patients with a patent in situ GEA for CABG. We investigated the results of the surgeries and how to manage the GEAs in abdominal surgery. RESULTS: Laparotomy was required for gastric cancer in 3 patients, pancreatic cancer in 3, hepatic cancer in 2, cholangiocarcinoma in 1, duodenal papillary head cancer in 1, and cholecystitis in 1; multiple abdominal surgeries were needed in 2 patients for cancer recurrence and ileus. The intraabdominal adhesions around the GEAs were minimal in all patients. No graft injury occurred at the time of opening of the abdomen, and the planned procedures were completed without any circulatory problems. In 3 patients undergoing pancreaticoduodenectomy, intraabdominal off-pump rerouting of the GEA with a short saphenous vein was necessary for en bloc resection of the cancers and lymph nodes. There was neither operative mortality nor graft-related cardiac event except for 1 due to multiple organ failure. CONCLUSIONS: Although intraabdominal rerouting of GEA is necessary for pancreaticoduodenectomy, abdominal surgery can be safely performed in patients with a patent in situ GEA coronary graft.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Artéria Gastroepiploica/transplante , Veia Safena/transplante , Idoso , Anastomose Cirúrgica , Estudos de Coortes , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Laparotomia/métodos , Masculino , Pessoa de Meia-Idade , Pancreaticoduodenectomia/efeitos adversos , Pancreaticoduodenectomia/métodos , Segurança do Paciente , Reoperação , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA