Eur Radiol ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985184

RESUMO

OBJECTIVES: To compare the diagnostic performance of conventional non-contrast CT, dual-energy spectral CT, and chemical-shift MRI (CS-MRI) in discriminating lipid-poor adenomas (> 10-HU on non-contrast CT) from non-adenomas. METHODS: A total of 110 patients (69 men; 41 women; mean age 66.5 ± 13.4 years) with 80 lipid-poor adenomas and 30 non-adenomas who underwent non-contrast dual-layer spectral CT and CS-MRI were retrospectively identified. For each lesion, non-contrast attenuation on conventional 120-kVp images, ΔHU-index ([attenuation difference between virtual monoenergetic 140-keV and 40-keV images]/conventional attenuation × 100), and signal intensity index (SI-index) were quantified. Each parameter was compared between adenomas and non-adenomas using the Mann-Whitney U-test. The area under the receiver operating characteristic curve (AUC) and sensitivity to achieve > 95% specificity for adenoma diagnosis were determined. RESULTS: Conventional non-contrast attenuation was lower in adenomas than in non-adenomas (22.4 ± 8.6 HU vs 32.8 ± 48.5 HU), whereas ΔHU-index (148.0 ± 103.2 vs 19.4 ± 25.8) and SI-index (41.6 ± 19.6 vs 4.2 ± 10.2) were higher in adenomas (all, p < 0.001). ΔHU-index showed superior performance to conventional non-contrast attenuation (AUC: 0.919 [95% CI: 0.852-0.963] vs 0.791 [95% CI: 0.703-0.863]; sensitivity: 75.0% [60/80] vs 27.5% [22/80], both p < 0.001), and near equivalent to SI-index (AUC: 0.952 [95% CI: 0.894-0.984], sensitivity 85.0% [68/80], both p > 0.05). Both the ΔHU-index and SI-index provided a sensitivity of 96.0% (48/50) for hypoattenuating adenomas (≤ 25 HU). For hyperattenuating (> 25 HU) adenomas, SI-index showed higher sensitivity than ΔHU-index (66.7% [20/30] vs 40.0% [12/30], p = 0.022). CONCLUSIONS: Non-contrast spectral CT and CS-MRI outperformed conventional non-contrast CT in distinguishing lipid-poor adenomas from non-adenomas. While CS-MRI demonstrated superior sensitivity for adenomas measuring > 25 HU, non-contrast spectral CT provided high discriminative values for adenomas measuring ≤ 25 HU. CLINICAL RELEVANCE STATEMENT: Spectral attenuation analysis improves the diagnostic performance of non-contrast CT in discriminating lipid-poor adrenal adenomas, potentially serving as an alternative to CS-MRI and obviating the necessity for additional diagnostic workup in indeterminate adrenal incidentalomas, particularly for lesions measuring ≤ 25 HU. KEY POINTS: Incidental adrenal lesion detection has increased as abdominal CT use has become more frequent. Non-contrast spectral CT and CS-MRI differentiated lipid-poor adenomas from non-adenomas better than conventional non-contrast CT. For lesions measuring ≤ 25 HU, spectral CT may obviate the need for additional evaluation.

2.
Phys Eng Sci Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884668

RESUMO

This study aimed to evaluate the impact of radiation dose and focal spot size on the image quality of super-resolution deep-learning reconstruction (SR-DLR) in comparison with iterative reconstruction (IR) and normal-resolution DLR (NR-DLR) algorithms for cardiac CT. Catphan-700 phantom was scanned on a 320-row scanner at six radiation doses (small and large focal spots at 1.4-4.3 and 5.8-8.8 mGy, respectively). Images were reconstructed using hybrid-IR, model-based-IR, NR-DLR, and SR-DLR algorithms. Noise properties were evaluated through plotting noise power spectrum (NPS). Spatial resolution was quantified with task-based transfer function (TTF); Polystyrene, Delrin, and Bone-50% inserts were used for low-, intermediate, and high-contrast spatial resolution. The detectability index (d') was calculated. Image noise, noise texture, edge sharpness of low- and intermediate-contrast objects, delineation of fine high-contrast objects, and overall quality of four reconstructions were visually ranked. Results indicated that among four reconstructions, SR-DLR yielded the lowest noise magnitude and NPS peak, as well as the highest average NPS frequency, TTF50%, d' values, and visual rank at each radiation dose. For all reconstructions, the intermediate- to high-contrast spatial resolution was maximized at 4.3 mGy, while the lowest noise magnitude and highest d' were attained at 8.8 mGy. SR-DLR at 4.3 mGy exhibited superior noise performance, intermediate- to high-contrast spatial resolution, d' values, and visual rank compared to the other reconstructions at 8.8 mGy. Therefore, SR-DLR may yield superior diagnostic image quality and facilitate radiation dose reduction compared to the other reconstructions, particularly when combined with small focal spot scanning.

3.
Eur Radiol ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753193

RESUMO

OBJECTIVES: To investigate the feasibility of low-radiation dose and low iodinated contrast medium (ICM) dose protocol combining low-tube voltage and deep-learning reconstruction (DLR) algorithm in thin-slice abdominal CT. METHODS: This prospective study included 148 patients who underwent contrast-enhanced abdominal CT with either 120-kVp (600 mgL/kg, n = 74) or 80-kVp protocol (360 mgL/kg, n = 74). The 120-kVp images were reconstructed using hybrid iterative reconstruction (HIR) (120-kVp-HIR), while 80-kVp images were reconstructed using HIR (80-kVp-HIR) and DLR (80-kVp-DLR) with 0.5 mm thickness. Size-specific dose estimate (SSDE) and iodine dose were compared between protocols. Image noise, CT attenuation, and contrast-to-noise ratio (CNR) were quantified. Noise power spectrum (NPS) and edge rise slope (ERS) were used to evaluate noise texture and edge sharpness, respectively. The subjective image quality was rated on a 4-point scale. RESULTS: SSDE and iodine doses of 80-kVp were 40.4% (8.1 ± 0.9 vs. 13.6 ± 2.7 mGy) and 36.3% (21.2 ± 3.9 vs. 33.3 ± 4.3 gL) lower, respectively, than those of 120-kVp (both, p < 0.001). CT attenuation of vessels and solid organs was higher in 80-kVp than in 120-kVp images (all, p < 0.001). Image noise of 80-kVp-HIR and 80-kVp-DLR was higher and lower, respectively than that of 120-kVp-HIR (both p < 0.001). The highest CNR and subjective scores were attained in 80-kVp-DLR (all, p < 0.001). There were no significant differences in average NPS frequency and ERS between 120-kVp-HIR and 80-kVp-DLR (p ≥ 0.38). CONCLUSION: Compared with the 120-kVp-HIR protocol, the combined use of 80-kVp and DLR techniques yielded superior subjective and objective image quality with reduced radiation and ICM doses at thin-section abdominal CT. CLINICAL RELEVANCE STATEMENT: Scanning at low-tube voltage (80-kVp) combined with the deep-learning reconstruction algorithm may enhance diagnostic efficiency and patient safety by improving image quality and reducing radiation and contrast doses of thin-slice abdominal CT. KEY POINTS: Reducing radiation and iodine doses is desirable; however, contrast and noise degradation can be detrimental. The 80-kVp scan with the deep-learning reconstruction technique provided better images with lower radiation and contrast doses. This technique may be efficient for improving diagnostic confidence and patient safety in thin-slice abdominal CT.

4.
Surg Case Rep ; 10(1): 119, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38735984

RESUMO

BACKGROUND: Follow-up is recommended for an asymptomatic unilocular hepatic cystic lesion without wall-thickness and nodular components. A few liver cystic lesions represent biliary cystic neoplasms, which are difficult to differentiate from simple cysts with benign mural nodules on imaging alone. CASE PRESENTATION: An 84-year-old woman with a history of simple liver cyst diagnosed one year prior was admitted for evaluation of a developed mural nodule in the cystic lesion. She had no specific symptoms and no abnormalities in blood tests except for carcinoembryonic antigen (5.0 ng/mL) and carbohydrate antigen (43.5 U/mL) levels. Contrast-enhanced computed tomography revealed a well-defined, low-attenuation lesion without a septum that had enlarged from 41 to 47 mm. No dilation of the bile duct was observed. A gradually enhancing mural nodule, 14 mm in diameter, was confirmed. MRI revealed a uniform water-intense cystic lesion with a mural nodule. This was followed by T2-enhanced imaging showing peripheral hypointensity and central hyperintensity. Enhanced ultrasonography revealed an enhanced nodule with a distinct artery within it. A needle biopsy of the wall nodule or aspiration of intracystic fluid was not performed to avoid tumor cell spillage. The possibility of a neoplastic cystic tumor could not be ruled out, so a partial hepatectomy was performed with adequate margins. Pathologically, the cystic lesion contained a black 5 mm nodule consisting of a thin, whitish fibrous wall and dilated vessels lined by CD31 and CD34 positive endothelial cells. The final diagnosis was a rare cavernous hemangioma within a simple liver cyst. CONCLUSIONS: Cavernous hemangiomas mimicking well-enhanced mural nodules can arise from simple liver cysts. In less malignant cases, laparoscopic biopsy or percutaneous targeted biopsy of the mural nodules, together with needle ablation, may be recommended to avoid unnecessary surgery.

5.
Abdom Radiol (NY) ; 49(5): 1626-1637, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38456897

RESUMO

PURPOSE: To evaluate the diagnostic performance of multiphase hepatic CT parameters (non-contrast attenuation, absolute and relative washout ratios [APW and RPW, respectively], and relative enhancement ratio [RER]) and chemical-shift MRI (CS-MRI) for discriminating lipid-poor adrenal adenomas (with non-contrast CT attenuation > 10 HU) from metastases in patients with hepatocellular carcinoma (HCC). METHODS: This retrospective study included HCC patients with lipid-poor adrenal lesions who underwent multiphase hepatic CT between January 2010 and December 2021. For each adrenal lesion, non-contrast attenuation, APW, RPW, RER, and signal-intensity index (SI-index) were measured. Each parameter was compared between adenomas and metastases. The area under the receiver operating characteristic curves (AUCs) and sensitivities to achieve 100% specificity for adenoma diagnoses were determined. RESULTS: 104 HCC patients (78 men; mean age, 71.8 ± 9.6 years) with 63 adenomas and 48 metastases were identified; CS-MRI was performed in 66 patients with 49 adenomas and 21 metastases within one year of CT. Lipid-poor adenomas showed lower non-contrast attenuation (22.9 ± 7.1 vs. 37.9 ± 9.4 HU) and higher APW (40.5% ± 12.8% vs. 23.7% ± 17.4%), RPW (30.0% ± 10.2% vs. 12.4% ± 9.6%), RER (329% ± 152% vs. 111% ± 43.0%), and SI-index (43.3 ± 20.7 vs. 10.8 ± 13.4) than HCC metastases (all p < .001). AUC for non-contrast attenuation, APW, RPW, RER, and SI-index were 0.894, 0.786, 0.904, 0.969, and 0.902, respectively. The sensitivities to achieve 100% specificity were 7.9%, 25.4%, 30.2%, 63.5%, and 24.5%, respectively. Combined RER and APW achieved the highest sensitivity of 73.0%. CONCLUSION: Multiphase hepatic CT allows for better discrimination between lipid-poor adrenal adenomas and metastases relative to CS-MRI, especially when combined with RER and washout parameters.


Assuntos
Neoplasias das Glândulas Suprarrenais , Carcinoma Hepatocelular , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Feminino , Carcinoma Hepatocelular/diagnóstico por imagem , Estudos Retrospectivos , Idoso , Imageamento por Ressonância Magnética/métodos , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Pessoa de Meia-Idade , Adenoma/diagnóstico por imagem , Meios de Contraste
6.
Clin J Gastroenterol ; 17(2): 352-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38363445

RESUMO

Hepatic artery pseudoaneurysms have been reported to occur in approximately 1% of cases after metal stenting for malignant biliary obstruction. In contrast, only a few cases have been reported as complications after plastic stenting for benign biliary disease. We report a 61-year-old man with cholangitis who presented with a rare complication of hemobilia after implantation of 7 Fr double pigtail plastic biliary stents. No bleeding was observed approximately one month after biliary stent tube removal. Contrast-enhanced CT scan revealed a circularly enhanced lesion (5 mm in diameter) in the arterial phase at the tip of the previously inserted plastic bile duct stent. Color Doppler ultrasonography enhanced the lesion and detected arterial blood flow inside. He was diagnosed with a hepatic artery pseudoaneurysm. However, he had no risk factors such as prolonged catheterization, severe cholangitis, liver abscess, or long-term steroid use. Superselective transarterial embolization using two metal microcoils was successfully completed without damage to the surrounding liver parenchyma. If hemobilia is suspected after insertion of a plastic bile duct stent, immediate monitoring using contrast-enhanced computed tomography or Doppler ultrasonography is recommended.


Assuntos
Falso Aneurisma , Colangite , Hemobilia , Masculino , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Hemobilia/terapia , Hemobilia/complicações , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Incidência , Colangite/complicações , Stents/efeitos adversos
7.
Eur Radiol ; 34(2): 1016-1025, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37597032

RESUMO

OBJECTIVES: Myocardial extracellular volume (ECV) on computed tomography (CT), an alternative to cardiac magnetic resonance (CMR), has significant practical clinical advantages. However, the consistency between ECVs quantified via CT and CMR in cardiac amyloidosis (CA) has not been investigated sufficiently. Therefore, the current study investigated the application of CT-ECV in CA with CMR-ECV as the reference standard. METHODS: We retrospectively evaluated 31 patients with CA who underwent cardiac CT and CMR. Pearson correlation analysis was performed to investigate correlations between CT-ECV and CMR-ECV at each segment. Further, correlations between ECV and clinical parameters were assessed. RESULTS: There were no significant differences in the mean global ECVs between CT scan and CMR (51.3% ± 10.2% vs 50.0% ± 10.5%). CT-ECV was correlated with CMR-ECV at the septal (r = 0.88), lateral (r = 0.80), inferior (r = 0.79), anterior (r = 0.77) segments, and global (r = 0.87). In both CT and CMR, the ECV had a weak to strong correlation with high-sensitivity cardiac troponin T level, a moderate correlation with global longitudinal strain, and an inverse correlation with left ventricular ejection fraction. Further, the septal ECV and global ECV had a slightly higher correlation with the clinical parameters. CONCLUSIONS: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA. Moreover, a significant correlation between CT-ECV and clinical parameters was observed. Thus, CT-ECV can be an imaging biomarker and alternative to CMR-ECV. CLINICAL RELEVANCE STATEMENT: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA, and CT-ECV can be used clinically as an imaging biomarker and alternative to CMR-ECV. KEY POINTS: • A significant correlation was found between CT myocardial extracellular volume and cardiac MR myocardial extracellular volume in patients with cardiac amyloidosis. • In CT and cardiac MR, the myocardial extracellular volume correlated well with high-sensitivity cardiac troponin T level, global longitudinal strain, and left ventricular ejection fraction. • CT myocardial extracellular volume can be an imaging biomarker and alternative to cardiac MR myocardial extracellular volume.


Assuntos
Amiloidose , Troponina T , Humanos , Volume Sistólico , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda , Miocárdio/patologia , Imageamento por Ressonância Magnética , Amiloidose/diagnóstico por imagem , Biomarcadores , Valor Preditivo dos Testes
8.
Acad Radiol ; 31(2): 514-522, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37775448

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to assess the utility of cardiac magnetic resonance imaging (MRI) T1 and T2 mapping as quantitative imaging biomarkers in transthyretin amyloid cardiomyopathy (ATTR-CM). MATERIALS AND METHODS: This study retrospectively evaluated 74 patients with confirmed wild-type ATTR-CM who underwent cardiac MRI, 99mTc-labeled pyrophosphate (99mTc-PYP) scintigraphy, and echocardiography. We assessed the quantitative disease parameters, for example, left ventricular ejection fraction (LVEF), and global longitudinal strain (GLS) by echocardiography, native T1, extracellular volume fraction (ECV), and native T2 value by cardiac MRI, heart-to-contralateral ratio (H/CL) by 99mTc-PYP, and high-sensitive cardiac troponin T. Myocardial native T2 of ≥50 ms was defined as myocardial edema. Correlations between the disease's quantitative parameters were evaluated, and the ECV was compared to other parameters in ATTR-CM with/without myocardial edema. RESULTS: ECV in all patients with ATTR-CM revealed a strong correlation with native T1 (r = 0.62), a moderate correlation with hs-TnT (r = 0.59), LVEF (r = -0.48), GLS (r = 0.58), and H/CL (r = 0.48). Correlations between ECV and other quantitative parameters decreased in ATTR-CM with myocardial edema except for H/CL. Meanwhile, the correlations increased in ATTR-CM without myocardial edema. CONCLUSION: The presence of myocardial edema affected the interpretation of ECV assessment, although ECV can be a comprehensive imaging biomarker for ATTR-CM. ECV showed a significant correlation with various quantitative disease parameters and can be a reliable disease monitoring marker in patients with ATTR-CM when myocardial edema was excluded.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Pré-Albumina , Cardiomiopatias/diagnóstico por imagem , Pirofosfato de Tecnécio Tc 99m , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Amiloidose/diagnóstico por imagem , Imageamento por Ressonância Magnética , Edema , Biomarcadores
9.
In Vivo ; 37(5): 2268-2275, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37652506

RESUMO

BACKGROUND: Multiple bilateral lung metastases secondary to hepatocellular carcinoma (HCC) are mainly treated with molecular therapy. Atezolizumab plus bevacizumab can provide excellent long-term survival for patients with a good response. CASE REPORT: A 67-year-old woman underwent right hepatectomy for a primary solitary HCC, 11 cm in diameter, after portal embolization. After 2 years, she developed bilateral lung metastases with >100 nodules, <1 cm in size. She had no viral hepatitis or liver cirrhosis, and the Child-Pugh Grade was A (5 points). Lenvatinib (12 mg daily) was administered as a first-line treatment and continued for 18 months. The best response was stable disease (SD). Subsequently, intravenous atezolizumab (1,200 mg) plus bevacizumab (15 mg/kg) was administered once every three weeks. The best response was SD, which continued for 26 months. After that, cabozantinib treatment was initiated and discontinued after one cycle. Subsequently, dual immune checkpoint inhibitor treatment (durvalumab + tremelimumab) was administered. She has had multiple, but lung-only, metastases over four years. She has been well as an outpatient with the Child-Pugh Grade of A and a performance status of 0. CONCLUSION: Even if atezolizumab plus bevacizumab does not induce a good response, a durable SD could prolong survival in patients with metastatic HCC while maintaining liver function and a good quality-of-life.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Neoplasias Pulmonares , Feminino , Humanos , Idoso , Carcinoma Hepatocelular/tratamento farmacológico , Bevacizumab , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico
10.
Radiol Cardiothorac Imaging ; 5(2): e220327, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37124644

RESUMO

Purpose: To evaluate the diagnostic performance of myocardium-to-lumen R1 (1/T1) ratio on postcontrast T1 maps for the detection of cardiac amyloidosis in a large patient sample. Materials and Methods: This retrospective study included consecutive patients who underwent MRI-derived extracellular volume fraction (MRI ECV) analysis between March 2017 and July 2021 because of known or suspected heart failure or cardiomyopathy. Pre- and postcontrast T1 maps were generated using the modified Look-Locker inversion recovery sequence. Diagnostic performances of MRI ECV and myocardium-to-lumen R1 ratio on postcontrast T1 maps (a simplified index not requiring a native T1 map and hematocrit level data) for detecting cardiac amyloidosis were evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Results: Of 352 patients (mean age, 63 years ± 16 [SD]; 235 men), 136 had cardiac amyloidosis. MRI ECV showed 89.0% (121 of 136; 95% CI: 82%, 94%) sensitivity and 98.6% (213 of 216; 95% CI: 96%, 100%) specificity for helping detect cardiac amyloidosis (cutoff value of 40% [AUC, 0.99 {95% CI: 0.97, 1.00}; P < .001]). Postcontrast myocardium-to-lumen R1 ratio showed 92.6% (126 of 136; 95% CI: 89%, 96%) sensitivity and 93.1% (201 of 216; 95% CI: 89%, 96%) specificity (cutoff value of 0.84 [AUC, 0.98 {95% CI: 0.95, 0.99}; P < .001]). There was no evidence of a difference in AUCs for each parameter (P = .10). Conclusion: Postcontrast myocardium-to-lumen R1 ratio showed excellent diagnostic performance comparable to that of MRI ECV in the detection of cardiac amyloidosis.Keywords: MR Imaging, Cardiac, Heart, Cardiomyopathies Supplemental material is available for this article. © RSNA, 2023.

12.
Eur Radiol ; 33(5): 3253-3265, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36973431

RESUMO

OBJECTIVES: To evaluate the image quality of deep learning-based reconstruction (DLR), model-based (MBIR), and hybrid iterative reconstruction (HIR) algorithms for lower-dose (LD) unenhanced head CT and compare it with those of standard-dose (STD) HIR images. METHODS: This retrospective study included 114 patients who underwent unenhanced head CT using the STD (n = 57) or LD (n = 57) protocol on a 320-row CT. STD images were reconstructed with HIR; LD images were reconstructed with HIR (LD-HIR), MBIR (LD-MBIR), and DLR (LD-DLR). The image noise, gray and white matter (GM-WM) contrast, and contrast-to-noise ratio (CNR) at the basal ganglia and posterior fossa levels were quantified. The noise magnitude, noise texture, GM-WM contrast, image sharpness, streak artifact, and subjective acceptability were independently scored by three radiologists (1 = worst, 5 = best). The lesion conspicuity of LD-HIR, LD-MBIR, and LD-DLR was ranked through side-by-side assessments (1 = worst, 3 = best). Reconstruction times of three algorithms were measured. RESULTS: The effective dose of LD was 25% lower than that of STD. Lower image noise, higher GM-WM contrast, and higher CNR were observed in LD-DLR and LD-MBIR than those in STD (all, p ≤ 0.035). Compared with STD, the noise texture, image sharpness, and subjective acceptability were inferior for LD-MBIR and superior for LD-DLR (all, p < 0.001). The lesion conspicuity of LD-DLR (2.9 ± 0.2) was higher than that of HIR (1.2 ± 0.3) and MBIR (1.8 ± 0.4) (all, p < 0.001). Reconstruction times of HIR, MBIR, and DLR were 11 ± 1, 319 ± 17, and 24 ± 1 s, respectively. CONCLUSION: DLR can enhance the image quality of head CT while preserving low radiation dose level and short reconstruction time. KEY POINTS: • For unenhanced head CT, DLR reduced the image noise and improved the GM-WM contrast and lesion delineation without sacrificing the natural noise texture and image sharpness relative to HIR. • The subjective and objective image quality of DLR was better than that of HIR even at 25% reduced dose without considerably increasing the image reconstruction times (24 s vs. 11 s). • Despite the strong noise reduction and improved GM-WM contrast performance, MBIR degraded the noise texture, sharpness, and subjective acceptance with prolonged reconstruction times relative to HIR, potentially hampering its feasibility.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Aprendizado Profundo , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem
13.
Anticancer Res ; 43(4): 1863-1867, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36974823

RESUMO

BACKGROUND/AIM: Operable peritoneal dissemination from distal cholangiocarcinoma after pancreaticoduodenectomy is rare. Furthermore, peritoneal dissemination mimicking liver metastasis has scarcely been reported. CASE REPORT: An 81-year-old woman received pancreaticoduodenectomy for distal cholangiocarcinoma. She was diagnosed with stage IIA (T3a N0 M0) and received curative resection. She did not receive adjuvant chemotherapy. As a result of the examination in our department, she showed two tumors, 20 mm and 8 mm in segments 7/8 and 7, respectively, in the subphrenic liver surface four and half years after the initial pancreaticoduo-denectomy. The larger tumor was slow-growing, and cystic degeneration was inside. Plain computed tomography imaging revealed an isodense tumor with a marginal high ring and weak early enhancement, and prolonged peripheral enhancement was recognized at the marginal portion. Magnetic resonance imaging showed a heterogeneous mass with peripheral hypointensity ring that may be caused by fibrous tissue. Although the smaller tumor was diagnosed only after admission, it presented similar imaging findings to the larger tumor. The preoperative diagnosis was suspected to be liver metastases from DCC or inflammatory pseudotumor. Laparoscopic partial liver resection with diaphragm dissection was performed for both tumors. Pathologically, the tumors were diagnosed as peritoneal dissemination from distal cholangiocarcinoma. In the disseminated cancer cells, the expression of Ki67 was decreased, which was suspected to be one of the reasons for the long recurrence-free interval. The patient is doing well without any recurrence three months after the second operation. CONCLUSION: Laparoscopic surgery can provide excellent results for diagnosing and treating unknown subphrenic tumors.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Neoplasias Hepáticas , Feminino , Humanos , Idoso de 80 Anos ou mais , Pancreaticoduodenectomia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/cirurgia , Colangiocarcinoma/tratamento farmacológico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/tratamento farmacológico , Ductos Biliares Intra-Hepáticos/patologia , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/cirurgia , Neoplasias dos Ductos Biliares/tratamento farmacológico
15.
Magn Reson Med Sci ; 22(2): 147-156, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697024

RESUMO

The application of machine learning (ML) and deep learning (DL) in radiology has expanded exponentially. In recent years, an extremely large number of studies have reported about the hepatobiliary domain. Its applications range from differential diagnosis to the diagnosis of tumor invasion and prediction of treatment response and prognosis. Moreover, it has been utilized to improve the image quality of DL reconstruction. However, most clinicians are not familiar with ML and DL, and previous studies about these concepts are relatively challenging to understand. In this review article, we aimed to explain the concepts behind ML and DL and to summarize recent achievements in their use in the hepatobiliary region.


Assuntos
Aprendizado Profundo , Radiologia , Inteligência Artificial , Aprendizado de Máquina , Radiologia/métodos , Imageamento por Ressonância Magnética
16.
Acad Radiol ; 30(1): 83-92, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35725692

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the performance of a machine learning method to differentiate malignant from benign soft tissue tumors based on textural features on multiparametric magnetic resonance imaging (mpMRI). MATERIALS AND METHODS: We enrolled 163 patients with soft tissue tumors whose diagnosis was pathologically proven (71 malignant, 92 benign). All patients underwent mpMRI. Twelve histographic and textural parameters were assessed on T1-weighted imaging (T1WI), T2-weighted imaging, diffusion-weighted imaging, apparent diffusion coefficient maps, and contrast-enhanced T1WI imaging. We compared mean signals of all sequences from the malignant and benign tumors using Welch's t-test. Prediction models were developed via a machine learning technique (support vector machine) using textural features of each sequence, clinical information (sex + age + tumor size), and the combined model incorporating all features. Areas under the receiver operating characteristic curves (AUCs) of these models were calculated using fivefold cross validation. RESULTS: The diagnostic ability of clinical information model (AUC 0.85) was not inferior to the model with textural features of each sequence (AUC 0.79-0.84). The combined model showed the highest diagnostic ability (AUC 0.89). The AUC of the combined model (0.89) was comparable to those of two board-certified radiologists (0.89 and 0.87). CONCLUSIONS: Machine learning methods based on textural features on mpMRI and clinical information offer adequate diagnostic performance to differentiate between malignant and benign soft tissue tumors.


Assuntos
Neoplasias Encefálicas , Neoplasias de Tecidos Moles , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Aprendizado de Máquina , Imagem de Difusão por Ressonância Magnética/métodos
17.
Radiology ; 306(3): e220542, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36255307

RESUMO

Background Large studies on the diagnostic performance of CT-derived myocardial extracellular volume fraction (ECV) for detecting cardiac amyloidosis are lacking. A simple and practical index as a surrogate for CT ECV would be clinically useful. Purpose To compare the diagnostic performances between CT-derived myocardial ECV and myocardium-to-lumen signal ratio for the detection of cardiac amyloidosis in a large patient sample. Materials and Methods This retrospective study included patients who underwent CT ECV analysis because of suspected heart failure or cardiomyopathy between January 2018 and July 2021. CT ECV was quantified using routine pre-transcatheter aortic valve replacement planning cardiac CT, pre-atrial fibrillation ablation planning cardiac CT, or coronary CT angiography with the addition of unenhanced and delayed phase cardiac CT scans. The diagnostic performances of CT ECV and myocardium-to-lumen signal ratio in delayed phase cardiac CT (a simplified index not requiring unenhanced CT and hematocrit) for detecting cardiac amyloidosis were evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Results Of 552 patients (mean age, 69 years ± 14 [SD]; 295 men), 41 had cardiac amyloidosis. The sensitivity of CT ECV for amyloidosis was 90% (37 of 41 patients [95% CI: 77, 97]), with a specificity of 92% (472 of 511 patients [95% CI: 90, 95]) and optimal ECV cutoff value of 37% (AUC, 0.97 [95% CI: 0.96, 0.99]). The sensitivity of myocardium-to-lumen signal ratio was 88% (36 of 41 patients [95% CI: 74, 96]), with a specificity of 92% (469 of 511 patients [95% CI: 89, 94]) and optimal myocardium-to-lumen signal ratio cutoff value of 0.87 (AUC, 0.96 [95% CI: 0.94, 0.97]; P = .27 for comparison with ECV). Conclusion CT-derived myocardial extracellular volume fraction and myocardium-to-lumen signal ratio showed comparable and excellent diagnostic performance in detecting cardiac amyloidosis in a large patient sample. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Williams in this issue.


Assuntos
Amiloidose , Cardiomiopatias , Masculino , Humanos , Idoso , Estudos Retrospectivos , Miocárdio , Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos
18.
Anticancer Res ; 42(11): 5663-5670, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36288845

RESUMO

BACKGROUND/AIM: Hepatocellular carcinoma (HCC) with bile duct tumor thrombus (BDTT) is highly malignant; therefore, continual, multidisciplinary treatments are essential. CASE REPORT: In this study, two 78- and 81-year-old men were treated with the Vater papilla-preserving strategy. Case 1 had advanced HCC with BDTT expanding to the common bile duct (B4) and portal vein tumor thrombus (PVTT) of the umbilical portion. He showed triple-positive tumor markers. He underwent an extended left hepatectomy without bile duct resection following percutaneous transhepatic biliary drainage and transarterial chemoembolization (TACE). Later, TACE in combination with percutaneous microwave ablation was performed to treat four intrahepatic recurrent HCCs. Case 2 had diffuse-type HCCs accompanied by BDTT (B4) and PVTT to the right portal vein. He underwent liver partition associated with portal vein ligation for staged hepatectomy without bile duct resection. Six months later, he developed a solitary recurrent BDTT with obstructive jaundice. After percutaneous transhepatic biliary drainage, he was treated with two TACE from the various feeding arteries. Both patients achieved complete responses and are doing well without viable tumors approximately 2 years after the initial treatment. CONCLUSION: The Vater papilla-preserving strategy is essential for obtaining long-term survival and recurrent-free status for patients with HCC with highly extended BDTT.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Trombose , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/cirurgia , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/cirurgia , Neoplasias dos Ductos Biliares/patologia , Trombose/cirurgia , Trombose/complicações , Biomarcadores Tumorais
19.
Eur J Radiol ; 151: 110280, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35381567

RESUMO

PURPOSE: This clinical and phantom study aimed to evaluate the impact of deep learning-based reconstruction (DLR) on image quality and its radiation dose optimization capability for multiphase hepatic CT relative to hybrid iterative reconstruction (HIR). METHODS: Task-based image quality was assessed with a physical evaluation phantom; the high- and low-contrast detectability of HIR and DLR images were computed from the noise power spectrum and task-based transfer function at five different size-specific dose estimate (SSDE) values in the range 5.3 to 18.0-mGy. For the clinical study, images of 73 patients who had undergone multiphase hepatic CT under both standard-dose (STD) and lower-dose (LD) examination protocols within a time interval of about four-months on average, were retrospectively examined. STD images were reconstructed with HIR, while LD with HIR (LD-HIR) and DLR (LD-DLR). SSDE, quantitative image noise, and contrast-to-noise ratio (CNR) were compared between protocols. The noise magnitude, noise texture, streak artifact, image sharpness, interface smoothness, and overall image quality were subjectively rated by two independent radiologists. RESULTS: In phantom study, the high- and low-contrast detectability of DLR images obtained at 5.3-mGy and 7.3-mGy, respectively, were slightly higher than those obtained with HIR at the STD protocol dose (18.0-mGy). In clinical study, LD-DLR yielded lower image noise, higher CNR, and higher subjective scores for all evaluation criteria than STD (all, p ≤ 0.05), despite having 52.8% lower SSDE (8.0 ± 2.5 vs. 16.8 ± 3.4-mGy). CONCLUSIONS: DLR improved the subjective and objective image quality of multiphase hepatic CT compared with HIR techniques, even at approximately half the radiation dose.


Assuntos
Aprendizado Profundo , Infecções Sexualmente Transmissíveis , Algoritmos , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
20.
Phys Med ; 95: 57-63, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35101703

RESUMO

PURPOSE: To compare the effects of tube voltage and iodinated concentration on increasing the iodinated radiation dose in computed tomography (CT). MATERIAL AND METHODS: Water and iodinated materials were inserted in an anthropomorphic thorax phantom. Helical CT scans were performed with tube voltages of 80 and 120 kV. Monte Carlo simulation of radiation doses in CT images was used to study the radiation dose profiles. The radiation doses at different iodine to water ratios in images were calculated from cumulative radiation doses for iodine and water at each iodine concentration, tube voltage, and peripheral/central location. A radiation dose ratio from 80 to 120 kV was calculated from cumulative radiation doses at the same iodine concentration. RESULTS: The iodinated radiation doses with small and large phantoms were 1.56-2.04 and 1.61-1.82 times higher at 80 kV and 1.55-2.23 and 1.22-1.79 times higher at 120 kV than those in water. In the central portion, the iodinated radiation dose ratio decreased by 1.14-0.75 and 1.20-0.93 times at 80 kV and 1.29-1.23 and 1.17-1.23 times at 120 kV with increasing iodinated concentrations. In the peripheral portion, the iodinated radiation dose was slightly higher for 80 kV than for 120 kV. In the central portion, the ratio decreased with increasing iodinated concentration. CONCLUSION: The increase in iodinated radiation dose caused by photoelectric absorption was greater with increased iodine load than with lower tube voltage.