Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Biomedicines ; 11(3)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36979921

RESUMO

The use of computer-aided detection models to diagnose lesions in images from wireless capsule endoscopy (WCE) is a topical endoscopic diagnostic solution. We revised our artificial intelligence (AI) model, RetinaNet, to better diagnose multiple types of lesions, including erosions and ulcers, vascular lesions, and tumors. RetinaNet was trained using the data of 1234 patients, consisting of images of 6476 erosions and ulcers, 1916 vascular lesions, 7127 tumors, and 14,014,149 normal tissues. The mean area under the receiver operating characteristic curve (AUC), sensitivity, and specificity for each lesion were evaluated using five-fold stratified cross-validation. Each cross-validation set consisted of between 6,647,148 and 7,267,813 images from 217 patients. The mean AUC values were 0.997 for erosions and ulcers, 0.998 for vascular lesions, and 0.998 for tumors. The mean sensitivities were 0.919, 0.878, and 0.876, respectively. The mean specificities were 0.936, 0.969, and 0.937, and the mean accuracies were 0.930, 0.962, and 0.924, respectively. We developed a new version of an AI-based diagnostic model for the multiclass identification of small bowel lesions in WCE images to help endoscopists appropriately diagnose small intestine diseases in daily clinical practice.

2.
Digestion ; 103(5): 367-377, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35772398

RESUMO

BACKGROUND/AIMS: Although most patients with presumptive colonic diverticular bleeding (CDB) do not undergo a small bowel investigation in clinical practice, no prospective study supports this management. We evaluated the utility of early small bowel capsule endoscopy (CE) after negative colonoscopy results. METHODS: This prospective study evaluated the diagnostic yield of early small bowel CE (≤3 days from visit) for consecutive patients with acute-onset hematochezia, when colonoscopy found colonic diverticulosis but did not identify the definite bleeding source (n = 51; presumptive CDB). As a matched control for comparing clinical outcomes, presumptive CDB patients without CE (n = 51) were retrospectively extracted. RESULTS: On CE for the prospective cohort, the rates of total positive findings, P2 findings (high bleeding potential according to the P classification), and blood pooling in the colon were 57%, 12% (ulceration, 8%; angioectasia, 4%), and 24%, respectively. The rates of rebleeding within 30 and 365 days were 16% and 29% in the prospective cohort with CE, respectively, and were not significantly different from those in the retrospective cohort without CE (10% and 25%, respectively). In addition, thromboembolism and mortality within 30 and 365 days were not significantly different between those with and without CE. CONCLUSION: Early CE detected a suspected small bowel bleeding source in 12% of acute-onset presumptive CDB patients but did not significantly improve major clinical outcomes. Therefore, routine CE is unnecessary for presumptive CDB patients after colonoscopy (UMIN000026676).


Assuntos
Endoscopia por Cápsula , Diverticulose Cólica , Endoscopia por Cápsula/métodos , Diverticulose Cólica/complicações , Diverticulose Cólica/diagnóstico , Endoscopia Gastrointestinal , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Humanos , Intestino Delgado/diagnóstico por imagem , Estudos Retrospectivos
3.
Endoscopy ; 52(9): 786-791, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32557474

RESUMO

BACKGROUND : Previous computer-aided detection systems for diagnosing lesions in images from wireless capsule endoscopy (WCE) have been limited to a single type of small-bowel lesion. We developed a new artificial intelligence (AI) system able to diagnose multiple types of lesions, including erosions and ulcers, vascular lesions, and tumors. METHODS : We trained the deep neural network system RetinaNet on a data set of 167 patients, which consisted of images of 398 erosions and ulcers, 538 vascular lesions, 4590 tumors, and 34 437 normal tissues. We calculated the mean area under the receiver operating characteristic curve (AUC) for each lesion type using five-fold stratified cross-validation. RESULTS : The mean age of the patients was 63.6 years; 92 were men. The mean AUCs of the AI system were 0.996 (95 %CI 0.992 - 0.999) for erosions and ulcers, 0.950 (95 %CI 0.923 - 0.978) for vascular lesions, and 0.950 (95 %CI 0.913 - 0.988) for tumors. CONCLUSION : We developed and validated a new computer-aided diagnosis system for multiclass diagnosis of small-bowel lesions in WCE images.


Assuntos
Endoscopia por Cápsula , Inteligência Artificial , Diagnóstico por Computador , Humanos , Intestino Delgado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação
4.
Oncol Lett ; 18(6): 6397-6404, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31807163

RESUMO

Although the detection of circulating tumor cells (CTCs) should be crucial for future personalized medicine, no efficient and flexible methods have been established. The current study established a polymeric custom-made chip for capturing CTCs with a high efficiency and flexibility. As an example of clinical application, the effects of self-expandable metallic stent (SEMS) placement on the release of cancer cells into the blood of patients with colorectal cancer and bowel obstruction were analyzed. This was assessed as the placement of SEMS may cause mechanical damage and physical force to malignant tissue, increasing the risk of cancer cell release into the bloodstream. The present study examined the number of CTCs using a custom-made chip, before, at 24 h after and at 4 days after SEMS placement in patients with colorectal cancer. The results revealed that, among the 13 patients examined, the number of CTCs was increased in three cases at 24 h after SEMS placement. However, this increase was temporary. The number of CTCs also decreased at 4 days after stent placement in most cases. The CTC chip of the current study detected the number of CD133-positive cancer stem-like cells, which did not change, even in the patient whose total number of CTCs temporarily increased. The results indicated that this custom-made microfluid system can efficiently and flexibly detect CTCs, demonstrating its potential for obtaining information during the management of patients with cancer.

5.
PLoS One ; 14(3): e0213281, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30822318

RESUMO

BACKGROUND: Factors associated with efficacy and safety of cold snare polypectomy (CSP) are not well established. The aim is to elucidate the predictors of R0 resection and immediate bleeding of CSP. METHODS: We retrospectively reviewed a database of patients who underwent CSP for subcentimetric polyps at the University of Tokyo Hospital in Japan. Using the data regarding the characteristics of patients and polyps, such as location, size, and macroscopic appearance; use of narrow band imaging with magnification (NBI-M); and endoscopists' experience, we revealed the predictive factors associated with R0 resection and immediate post-CSP bleeding by univariate and multivariate analyses. RESULTS: In total, 399 polyps, in 200 patients without antithrombotics, were removed. Failure of tissue retrieval was noted in 4% of resected lesions. There was no intramucosal carcinoma observed. The overall rate of R0 resection was 46%. Multivariate analysis elucidated that the observation of the polyp with NBI-M was an independent predictor associated with R0 resection (odds ratio [OR] 1.90; p = 0.024). Although immediate post-CSP bleeding occurred in 19 polyps (4.8%), no delayed bleeding or perforation was observed. Multivariate analysis revealed protruded lesion as an independent risk factor for immediate bleeding (OR 3.54; p = 0.018). CONCLUSIONS: A higher rate of R0 resection with CSP can be achieved by performing colonoscopy with NBI-M, than with white-light imaging. Macroscopic protruding appearance of a polyp is a risk factor for immediate bleeding.


Assuntos
Pólipos do Colo/cirurgia , Colonoscopia , Criocirurgia/efeitos adversos , Hemorragia Pós-Operatória/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pólipos do Colo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/etiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
6.
J Gastroenterol Hepatol ; 33(7): 1327-1334, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29231993

RESUMO

BACKGROUND: Among patients with obscure gastrointestinal bleeding (OGIB), endoscopic ulcerative lesions in the small bowel have diverse etiologies and often cause rebleeding. Certain characteristics of patients or ulcerations may be reasonable indications for diagnostic balloon-assisted endoscopy (BAE) to assess etiology and may be risks of rebleeding; however, these characteristics are unclear. We aimed to elucidate appropriate indications for diagnostic BAE and predictors of long-term rebleeding in patients with small bowel ulcerative lesions. METHODS: We conducted a multicenter retrospective cohort study of 68 patients with OGIB, in whom small bowel ulcerative lesions were detected by capsule endoscopy (n = 60) and/or BAE (n = 43). Patients' characteristics, including medications and endoscopic findings, were evaluated. Predictors of the need for diagnostic BAE to determine ulceration etiology were identified by logistic regression analysis. Rebleeding risks were evaluated using Cox proportional hazards analysis. RESULTS: Single ulcerations were diagnosed in 26 patients, and multiple ulcerations were diagnosed in 42 patients. Among 43 patients who underwent BAE, ulceration etiology was identified in 12 (28%) patients. In the etiology identification, BAE was more useful for a single ulceration than for multiple ulcerations (P < 0.001). Among the 68 patients, rebleeding occurred in 14 (21%) patients during a mean follow-up period of 17 months. Aspirin use and multiple ulcerations were significant predictors of rebleeding (P < 0.05). CONCLUSIONS: When we manage small bowel ulcerative lesions in OGIB patients, a single ulceration is a reasonable indication for the diagnostic BAE. The rebleeding rate was lower for single ulcerations than for multiple ulcerations.


Assuntos
Endoscopia Gastrointestinal/métodos , Intestino Delgado , Úlcera Péptica Hemorrágica/diagnóstico , Úlcera Péptica Hemorrágica/etiologia , Idoso , Aspirina/efeitos adversos , Endoscopia por Cápsula , Estudos de Coortes , Feminino , Seguimentos , Previsões , Humanos , Modelos Logísticos , Masculino , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos
7.
Int J Colorectal Dis ; 32(6): 839-845, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28091843

RESUMO

PURPOSE: The cumulative incidence of post-colonoscopy colorectal cancer remains unclear. Our aims were to estimate the incidence of and identify risk factors associated with post-colonoscopy colorectal cancer. METHODS: We conducted a retrospective cohort study using the colonoscopy database of the Department of Gastroenterology, the University of Tokyo Hospital Records from1995-2012. A cohort of 2544 patients, who received multiple colonoscopies without colorectal cancer findings at first colonoscopy, was selected. The primary outcome was post-colonoscopy colorectal cancer; data were censored at the date of final colonoscopy. We assessed patients' background characteristics, colonoscopy findings, and cancer characteristics, including location and size. The cumulative incidence of colorectal cancer was evaluated, and a Cox proportional hazards model was used to estimate hazard ratios (HRs). RESULTS: Colorectal cancer was identified in seven (0.77/1000 person-years) patients during the mean follow-up period of 3.6 years (maximum, 17 years). The cumulative incidence of colorectal cancer was 0, 0.47, 0.62, and 0.62% at 1, 5, 10, and 15 years, respectively. Cancer was identified in the rectum in five of seven patients. Polyp size >10 mm (HR 5.7, p = 0.023) and intubation time >30 min (HR 11.6, p = 0.003) at first colonoscopy were associated significantly with an increased incidence of post-colonoscopy colorectal cancer. CONCLUSIONS: Although several factors were associated with an increased risk of post-colonoscopy colorectal cancer, the incidence of this disease might be low in patients who received at least twice colonoscopy. High proportion of rectal cancer in post-colonoscopy colorectal cancer should be noted.


Assuntos
Colonoscopia , Neoplasias Colorretais/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA