Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Exerc Rehabil ; 19(3): 149-162, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37435594

RESUMO

This study aimed to investigate the effect of whole body vibration (WBV) on the sensory and motor nerve components with sciatic nerve injury model rats. Surgery was performed on 21 female Wister rats (6-8 weeks) under intraperitoneal anesthesia. The nerve-crush injuries for the left sciatic nerve were inflicted using a Sugita aneurysm clip. The sciatic nerve model rats were randomly divided into two groups (n=9; control group, n=12; WBV group). The rats in the WBV group walked in the cage with a vibratory stimulus (frequency 50 Hz, 20 min/day, 5 times/wk), while those in the control group walked in the cage without any vibratory stimulus. We used heat stimulation-induced sensory threshold and lumbar magnetic stimulation-induced motor-evoked potentials (MEPs) to measure the sensory and motor nerve components, respectively. Further, morphological measurements, bilateral hind-limb dimension, bilateral gastrocnemius dimension, and weight were evaluated. Consequently, there were no significant differences in the sensory threshold at the injury side between the control and WBV groups. However, at 4 and 6 weeks postoperatively, MEPs latencies in the WBV group were significantly shorter than those in the control group. Furthermore, both sides of the hind-limb dimension at 6 weeks postoperatively, the left side of the gastrocnemius dimension, and both sides of the gastrocnemius weight significantly increased. In conclusion, WBV especially accelerates the functional recovery of motor nerve components in sciatic nerve-crush injury model rats.

2.
Comput Aided Surg ; 20(1): 29-33, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26290052

RESUMO

OBJECTIVE: We developed a novel method of producing accurate range images of the velopharynx using a three-dimensional (3D) endoscope to obtain detailed measurements of velopharyngeal movements. The purpose of the present study was to determine the relationship between the distance from the endoscope to an object, elucidate the measurement accuracy along the temporal axes, and determine the degree of blurring when using a jig to fix the endoscope. METHODS: An endoscopic measuring system was developed in which a pattern projection system was incorporated into a commercially available 3D endoscope. After correcting the distortion of the camera images, range images were produced using pattern projection to achieve stereo matching. Graph paper was used to measure the appropriate distance from the camera to an object, the mesial buccal cusp of the right maxillary first molar was measured to clarify the range image stability, and an electric actuator was used to evaluate the measurement accuracy along the temporal axes. RESULTS: The measurement error was substantial when the distance from the camera to the subject was >6.5 cm. The standard error of the 3D coordinate value produced from 30 frames was within 0.1 mm (range, 0.01-0.08 mm). The measurement error of the temporal axes was 9.16% in the horizontal direction and 9.27% in the vertical direction. CONCLUSION: The optimal distance from the camera to an object is <6.5 cm. The present endoscopic measuring system can provide stable range images of the velopharynx when using an appropriate fixation method and enables quantitative analysis of velopharyngeal movements.


Assuntos
Algoritmos , Anormalidades Craniofaciais/cirurgia , Endoscópios , Imageamento Tridimensional/métodos , Movimento , Imagens de Fantasmas , Faringe/fisiopatologia , Anormalidades Craniofaciais/fisiopatologia , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
3.
J Oral Maxillofac Surg ; 73(4): 781-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25661503

RESUMO

Squamous cell carcinoma throughout the epithelium of a lateral cervical cyst is considered extremely rare. This report describes an additional case of this very rare clinical condition. A 70-year-old man presented with a well-defined, immobile, painless mass in the left neck that was excised with a diagnosis of branchial cyst. Histologic findings of the excised specimen were lateral branchial cyst with high-grade dysplasia and carcinoma of the squamous epithelial lining. The patient was followed for more than 2 years 10 months and no evidence of recurrence or other cancer has been found.


Assuntos
Branquioma/patologia , Carcinoma de Células Escamosas/patologia , Neoplasias de Cabeça e Pescoço/patologia , Idoso , Biópsia por Agulha Fina/métodos , Transformação Celular Neoplásica/patologia , Seguimentos , Humanos , Masculino , Músculos do Pescoço/patologia
4.
J Craniomaxillofac Surg ; 43(1): 144-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25487672

RESUMO

OBJECTIVES: The purpose of this study was to clarify gender differences in posed smiles using principal component analysis (PCA). MATERIALS AND METHODS: Fourteen adult volunteers, 7 males and 7 females, were enrolled. Using the motion analyzing system we developed, range images and 5 × 5 virtual grids were produced across the whole sequence while the volunteers were asked to smile. Two sets of all intersections of the virtual grids captured while the subject was smiling were regarded as PCA variables. Discriminate analysis was then applied to compare the males and females. RESULTS: The first and second principal component scores (PCSs) were plotted on the x-axis and y-axis, respectively. The center of gravity of the PCSs is shown by the plus on the x-axis and minus on the y-axis for the males and by the minus on the x-axis and the plus on the y-axis for the females. Discriminate analyses of the PCSs revealed a correct gender classification rate of 74.4% for posed smiles. CONCLUSIONS: While the sample size is too small to extrapolate from these results, we can conclude that PCA can be used to identify gender differences while smiling.


Assuntos
Sorriso , Adulto , Pontos de Referência Anatômicos/anatomia & histologia , Pontos de Referência Anatômicos/fisiologia , Análise Discriminante , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Lábio/anatomia & histologia , Lábio/fisiologia , Masculino , Fotogrametria/estatística & dados numéricos , Análise de Componente Principal , Fatores Sexuais , Gravação em Vídeo/estatística & dados numéricos , Adulto Jovem
5.
J Craniomaxillofac Surg ; 42(8): 1650-4, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24969766

RESUMO

To clarify the mechanisms of rigid and semi-rigid mandibular repositioning devices (MRDs) in obstructive sleep apnea syndrome (OSAS), seven and 13 patients received rigid and semi-rigid MRDs, respectively. Each patient underwent polysomnographic and computed tomographic examinations at the initial consultation and after symptom improvement. Three-dimensional models of the upper airway (hard palate level to epiglottic base) were reconstructed by image processing software (Mimics version 14.2) to measure airway morphology. The mean age and body mass index were 58.1 years and 24.8 kg/m(2), respectively, in the rigid MRD group and 57.9 years and 23.2 kg/m(2), respectively, in the semi-rigid MRD group. The apnea-hypopnea index significantly improved (P < 0.05, Wilcoxon signed-rank test) from 22.0 to 8.9 and 20.5 to 11.5 events per hour of sleep in the respective groups. The cross-sectional areas measured at the epiglottic tip (from 2.0 to 2.6 cm(2)) and hard palate (from 2.6 to 3.3 cm(2)) levels also increased in the respective groups (P < 0.05). However, airway volume, cross-sectional area measured at the uvular tip level, and anteroposterior and transverse diameters of the airway were not significantly different. In conclusion, both types of MRDs improve respiratory status, but they affect different parts of the airway.


Assuntos
Avanço Mandibular/instrumentação , Desenho de Aparelho Ortodôntico , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Anatomia Transversal , Índice de Massa Corporal , Cefalometria/métodos , Epiglote/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Tomografia Computadorizada Multidetectores/métodos , Ensaios Clínicos Controlados não Aleatórios como Assunto , Palato Duro/patologia , Palato Mole/patologia , Faringe/patologia , Polissonografia/métodos , Estudos Prospectivos , Língua/patologia , Úvula/patologia
6.
J Craniomaxillofac Surg ; 42(5): 428-31, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23830766

RESUMO

OBJECTIVES: The purpose of this study was to determine the three-dimensional reproducibility of lip movement during a posed smile using a video-based motion analyzing system. MATERIALS AND METHODS: In six adult volunteers (4 males and 2 females), the lip motions during a posed smile were recorded six times. Using our recently-developed motion analyzing system, range images were produced across the whole sequence during the posed smile. Virtual grids of 5 × 5 were fitted onto the surfaces, and the three-dimensional coordinates of the intersections of these grids were then computed. The magnitude of the shift of the intersections during smiling was calculated and summed in each area. Intraclass correlation coefficients (ICC), ICC (1,1) for intra-rater reliability and ICC (2,1) for inter-rater reliability were calculated. The number of repeated measurements necessary for an ICC level beyond 0.8 was determined using the formula of Spearman-Brown. RESULTS: The ICC (1,1) and ICC (2,1) ranged from 0.71 to 0.83 and from 0.77 to 0.99, respectively. The number of repeated measurements necessary for an ICC beyond 0.8 was 2. CONCLUSIONS: From the present study, both the three-dimensional intra-rater and inter-rater reliabilities during a posed smile were considered to be relatively high, and enough reliability could be expected by calculating the average of the values measured two times. However, the sample size was very small, this could not be generalized simplistically.


Assuntos
Imageamento Tridimensional/estatística & dados numéricos , Lábio/fisiologia , Sorriso/fisiologia , Gravação em Vídeo/estatística & dados numéricos , Adulto , Algoritmos , Pontos de Referência Anatômicos/anatomia & histologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Lábio/anatomia & histologia , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Interface Usuário-Computador , Gravação em Vídeo/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA