Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 101(17): 1613-1614, 2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31483406
2.
Artigo em Inglês | MEDLINE | ID: mdl-28469487

RESUMO

Minimally invasive percutaneous plate osteosynthesis was developed on the concept that preservation of the soft tissue envelope during surgical management of distal tibial fractures is of paramount importance. We report on our early experience using this technique over a 1-year period with 14 such injuries that were treated by a locking compression plate via minimally invasive surgery. The surgical reduction was excellent in most of the cases and all fractures healed uneventfully. One superficial infection and a wound slough were the only complications recorded. The mean follow-up was at 15 months, and all patients were satisfied with a mean ankle-hindfoot score of 84. Early results of such management are very encouraging.

3.
J Bone Joint Surg Am ; 99(5): 427-436, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28244914

RESUMO

BACKGROUND: Large-diameter (≥36-mm) metal-on-metal (MoM) total hip replacements have been shown to fail at an unacceptably high rate. Globally, the DePuy Pinnacle prosthesis was the most widely used device of this type. There is evidence to suggest that one of the main reasons for the poor clinical performance of large-diameter MoM prostheses is the metal debris released from the head-stem taper junction-i.e., taper junction failure. The aim of this study was to investigate variation in the as-manufactured finish of the female taper surface and to determine its influence on material loss. We hypothesized that rougher surfaces with higher relative material peaks would be significantly associated with greater taper wear rates. METHODS: We analyzed 93 Articul/eze femoral head tapers with a 36-mm bearing diameter that had been used in combination with a Corail titanium uncemented stem. The influence of the surface topography of the as-manufactured female taper surface on taper wear was examined by means of a multiple regression model, taking into account other known variables. RESULTS: We identified great variation in the as-manufactured surface finish of the female taper surface, with a range of measured Ra values from 0.14 to 4.20 µm. The roughness of the female taper surface appeared to be the most important variable associated with taper wear (p < 0.001). The best-fitting regression model, including duration in vivo, head offset, reduced peak height (Rpk) value, stem shaft angle, and bearing surface wear rate, explained approximately 44% of the variation in taper wear rates. CONCLUSIONS: We concluded that the roughness of the female taper surface appears to be a significant factor in metal debris release from head-stem taper junctions. CLINICAL RELEVANCE: This study shows evidence that previously unappreciated variations in manufacturing processes may have a major impact on the clinical outcomes of patients.


Assuntos
Artroplastia de Quadril/instrumentação , Análise de Falha de Equipamento , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Corrosão , Remoção de Dispositivo , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação
4.
Hip Int ; 26(2): 153-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26868116

RESUMO

INTRODUCTION: Hip fractures are becoming an increasing public health issue due to an ageing population (1). Total hip replacements (THR) produce better outcomes in certain patients who were functioning independently before the injury (2). We aimed to assess whether the management of intracapsular hip fracture is carried out in accordance with the National Institute for Health and Care Excellence (NICE) hip fracture guidance (1) and the outcomes with regards to performing THRs on those patients who fulfil the described criteria. METHOD: Data was collected retrospectively from the 1st April 2012 to 31st March 2013 from all fractured neck of femur patients admitted to our hospital. RESULTS: Of the 382 patients fit for an operation, 78 (20.4%) met with the NICE hip fracture guidance for a total hip replacement. Of those eligible, 32 (41.0%) did receive a THR and 4 (2.8%) patients of the 142 not eligible for a total hip replacement also received a THR. DISCUSSIONS: Of those eligible for a THR, the patients who underwent that procedure had a significantly lower mortality rate compared to those who underwent a hemiarthroplasty (0% versus 19.6% at 1 year, p = 0.007). However, those who did not meet the NICE criteria but underwent a THR had the worst mortality rate (50% at 30 days and 1 year). The provision rate of THR in displaced intracapsular hip fracture is low at 41.0% for those who met the NICE criteria. The results suggest that the decision process when determining if a patient should undergo THR for a fractured neck of femur is multifactorial.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Colo Femoral/etiologia , Fixação Interna de Fraturas/normas , Guias de Prática Clínica como Assunto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Colo Femoral/diagnóstico , Fraturas do Colo Femoral/cirurgia , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA