Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Clin Biomech (Bristol, Avon) ; 111: 106157, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38103526

RESUMO

BACKGROUND: Predicting breast tissue motion using biomechanical models can provide navigational guidance during breast cancer treatment procedures. These models typically do not account for changes in posture between procedures. Difference in shoulder position can alter the shape of the pectoral muscles and breast. A greater understanding of the differences in the shoulder orientation between prone and supine could improve the accuracy of breast biomechanical models. METHODS: 19 landmarks were placed on the sternum, clavicle, scapula, and humerus of the shoulder girdle in prone and supine breast MRIs (N = 10). These landmarks were used in an optimization framework to fit subject-specific skeletal models and compare joint angles of the shoulder girdle between these positions. FINDINGS: The mean Euclidean distance between joint locations from the fitted skeletal model and the manually identified joint locations was 15.7 mm ± 2.7 mm. Significant differences were observed between prone and supine. Compared to supine position, the shoulder girdle in the prone position had the lateral end of the clavicle in more anterior translation (i.e., scapula more protracted) (P < 0.05), the scapula in more protraction (P < 0.01), the scapula in more upward rotation (associated with humerus elevation) (P < 0.05); and the humerus more elevated (P < 0.05) for both the left and right sides. INTERPRETATION: Shoulder girdle orientation was found to be different between prone and supine. These differences would affect the shape of multiple pectoral muscles, which would affect breast shape and the accuracy of biomechanical models.


Assuntos
Articulação do Ombro , Ombro , Humanos , Ombro/diagnóstico por imagem , Ombro/fisiologia , Decúbito Dorsal , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos , Escápula/diagnóstico por imagem , Escápula/fisiologia , Rotação , Imageamento por Ressonância Magnética
2.
Artigo em Inglês | MEDLINE | ID: mdl-38083471

RESUMO

Clinical translation of personalised computational physiology workflows and digital twins can revolutionise healthcare by providing a better understanding of an individual's physiological processes and any changes that could lead to serious health consequences. However, the lack of common infrastructure for developing these workflows and digital twins has hampered the realisation of this vision. The Auckland Bioengineering Institute's 12 LABOURS project aims to address these challenges by developing a Digital Twin Platform to enable researchers to develop and personalise computational physiology models to an individual's health data in clinical workflows. This will allow clinical trials to be more efficiently conducted to demonstrate the efficacy of these personalised clinical workflows. We present a demonstration of the platform's capabilities using publicly available data and an existing automated computational physiology workflow developed to assist clinicians with diagnosing and treating breast cancer. We also demonstrate how the platform facilitates the discovery and exploration of data and the presentation of workflow results as part of clinical reports through a web portal. Future developments will involve integrating the platform with health systems and remote-monitoring devices such as wearables and implantables to support home-based healthcare. Integrating outputs from multiple workflows that are applied to the same individual's health data will also enable the generation of their personalised digital twin.Clinical Relevance- The proposed 12 LABOURS Digital Twin Platform will enable researchers to 1) more efficiently conduct clinical trials to assess the efficacy of their computational physiology workflows and support the clinical translation of their research; 2) reuse primary and derived data from these workflows to generate novel workflows; and 3) generate personalised digital twins by integrating the outputs of different computational physiology workflows.


Assuntos
Biologia Computacional , Software , Biologia Computacional/métodos , Fluxo de Trabalho
3.
Heart Rhythm ; 19(2): 295-305, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34662707

RESUMO

BACKGROUND: Ventricular fibrillation (VF) is characterized by multiple wavelets and rotors. No equation to predict the number of rotors and wavelets observed during fibrillation has been validated in human VF. OBJECTIVE: The purpose of this study was to test the hypothesis that a single equation derived from a Markov M/M/∞ birth-death process could predict the number of rotors and wavelets occurring in human clinical VF. METHODS: Epicardial induced VF (256-electrode) recordings obtained from patients undergoing cardiac surgery were studied (12 patients; 62 epochs). Rate constants for phase singularity (PS) (which occur at the pivot points of rotors) and wavefront (WF) formation and destruction were derived by fitting distributions to PS and WF interformation and lifetimes. These rate constants were combined in an M/M/∞ governing equation to predict the number of PS and WF in VF episodes. Observed distributions were compared to those predicted by the M/M/∞ equation. RESULTS: The M/M/∞ equation accurately predicted average PS and WF number and population distribution, demonstrated in all epochs. Self-terminating episodes of VF were distinguished from VF episodes requiring termination by a trend toward slower PS destruction, slower rates of PS formation, and a slower mixing rate of the VF process, indicated by larger values of the second largest eigenvalue modulus of the M/M/∞ birth-death matrix. The longest-lasting PS (associated with rotors) had shorter interactivation time intervals compared to shorter-lasting PS lasting <150 ms (∼1 PS rotation in human VF). CONCLUSION: The M/M/∞ equation explains the number of wavelets and rotors observed, supporting a paradigm of VF based on statistical fibrillatory dynamics.


Assuntos
Morte Súbita Cardíaca/etiologia , Fibrilação Ventricular/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Mapeamento Epicárdico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Cadeias de Markov , Modelos Cardiovasculares
4.
Interface Focus ; 9(4): 20190034, 2019 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-31263540

RESUMO

Clinicians face many challenges when diagnosing and treating breast cancer. These challenges include interpreting and co-locating information between different medical imaging modalities that are used to identify tumours and predicting where these tumours move to during different treatment procedures. We have developed a novel automated breast image analysis workflow that integrates state-of-the-art image processing and machine learning techniques, personalized three-dimensional biomechanical modelling and population-based statistical analysis to assist clinicians during breast cancer detection and treatment procedures. This paper summarizes our recent research to address the various technical and implementation challenges associated with creating a fully automated system. The workflow is applied to predict the repositioning of tumours from the prone position, where diagnostic magnetic resonance imaging is performed, to the supine position where treatment procedures are performed. We discuss our recent advances towards addressing challenges in identifying the mechanical properties of the breast and evaluating the accuracy of the biomechanical models. We also describe our progress in implementing a prototype of this workflow in clinical practice. Clinical adoption of these state-of-the-art modelling techniques has significant potential for reducing the number of misdiagnosed breast cancers, while also helping to improve the treatment of patients.

5.
J Mech Behav Biomed Mater ; 37: 48-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24942626

RESUMO

The use of synthetic polypropylene mesh for hernia surgical repair and the correction of female pelvic organ prolapse have been controversial due to increasing post-operative complications, including mesh erosion, chronic pain, infection and support failure. These morbidities may be related to a mismatch of mechanical properties between soft tissues and the mesh. The aim of this study was to gain a better understanding of the biomechanical behavior of Prolene polypropylene mesh (Ethicon, Sommerville, NJ, USA), which is widely used for a variety of surgical repair procedures. The stiffness and permanent deformation of Prolene mesh were compared in different directions by performing uniaxial tensile failure tests, cyclic and creep tests at simulated physiological loads in the coursewise (0°), walewise (90°) and the diagonal (45°) directions. Failure tests suggest that the mechanical properties of the mesh is anisotropic; with response at 0° being the most compliant while 90° was the stiffest. Irreversible deformation and viscoelastic behavior were observed in both cyclic and creep tests. The anisotropic property may be relevant to the placement of mesh in surgery to maximize long term mesh performance. The considerable permanent deformation may be associated with an increased risk of post-operative support failure.


Assuntos
Teste de Materiais , Fenômenos Mecânicos , Polipropilenos , Telas Cirúrgicas , Anisotropia , Elasticidade , Viscosidade
6.
Med Image Anal ; 17(8): 1256-64, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23860392

RESUMO

This paper presents a novel X-ray and MR image registration technique based on individual-specific biomechanical finite element (FE) models of the breasts. Information from 3D magnetic resonance (MR) images was registered to X-ray mammographic images using non-linear FE models subject to contact mechanics constraints to simulate the large compressive deformations between the two imaging modalities. A physics-based perspective ray-casting algorithm was used to generate 2D pseudo-X-ray projections of the FE-warped 3D MR images. Unknown input parameters to the FE models, such as the location and orientation of the compression plates, were optimised to provide the best match between the pseudo and clinical X-ray images. The methods were validated using images taken before and during compression of a breast-shaped phantom, for which 12 inclusions were tracked between imaging modalities. These methods were then applied to X-ray and MR images from six breast cancer patients. Error measures (such as centroid and surface distances) of segmented tumours in simulated and actual X-ray mammograms were used to assess the accuracy of the methods. Sensitivity analysis of the lesion co-localisation accuracy to rotation about the anterior-posterior axis was then performed. For 10 of the 12 X-ray mammograms, lesion localisation accuracies of 14 mm and less were achieved. This analysis on the rotation about the anterior-posterior axis indicated that, in cases where the lesion lies in the plane parallel to the mammographic compression plates, that cuts through the nipple, such rotations have relatively minor effects.This has important implications for clinical applicability of this multi-modality lesion registration technique, which will aid in the diagnosis and treatment of breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Modelos Biológicos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Algoritmos , Simulação por Computador , Feminino , Análise de Elementos Finitos , Humanos , Aumento da Imagem/métodos , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Circ Arrhythm Electrophysiol ; 4(5): 684-91, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21841193

RESUMO

BACKGROUND: Ischemic ventricular fibrillation in experimental models has been shown to progress through a series of stages. Progression of ischemic VF in the in vivo human heart has not been determined. METHODS AND RESULTS: We studied 10 patients undergoing cardiac surgery. Ventricular fibrillation was induced by burst pacing. After 30 seconds, global myocardial ischemia was induced by aortic cross-clamp and maintained for 2.5 minutes, followed by coronary reflow. Epicardial activity was sampled (1 kHz) with a sock that contained 256 unipolar contact electrodes. Dominant frequencies were calculated with a fast Fourier transform with a moving window. The locations of phase singularities and activation wavefronts were identified at 10-ms intervals. Preischemic (perfused) ventricular fibrillation was maintained by a disorganized mix of large and small wavefronts. During global myocardial ischemia, mean dominant frequencies decreased from 6.4 to 4.7 Hz at a rate of -0.011±0.002 Hz s(-1) (P<0.001) and then increased rapidly to 7.4 Hz within 30 seconds of reflow. In contrast, the average number of epicardial phase singularities increased during ischemia from 7.7 to 9.7 at a rate of 0.013±0.005 phase singularities per second (P<0.01) and remained unchanged during reflow, at 10.3. The number of wavefronts showed a similar time course to the number of phase singularities. CONCLUSIONS: In human ventricular fibrillation, we found an increase in complexity of electric activation patterns during global myocardial ischemia, and this was not reversed during reflow despite an increase in activation rate.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Reperfusão Miocárdica , Fibrilação Ventricular/fisiopatologia , Adulto , Idoso , Animais , Modelos Animais de Doenças , Eletrodos , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Fatores de Tempo
8.
Breast Cancer Res Treat ; 130(2): 699-705, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21850393

RESUMO

Detailed knowledge of the lymphatic drainage of the breast is limited. Lymphoscintigraphy is a technique used during breast cancer treatment to accurately map patterns of lymphatic drainage from the primary tumour to the draining lymph nodes. This study aimed to create a statistical model to analyse the spread of breast cancer and primary tumour location using a large lymphoscintigraphy database, and visualise the results with a novel computational model. This study was based on lymphoscintigraphy data from 2,304 breast cancer patients treated at the Royal Prince Alfred Hospital Medical Centre in Sydney, Australia. Bayesian inferential techniques were implemented to estimate the probabilities of lymphatic drainage from each region of the breast to each draining node field, to multiple node fields, and to determine probabilities of tumour prevalence in each breast region. A finite element model of the torso and discrete model of the draining node fields were created to visualise these data and a software tool was developed to display the results ( www.abi.auckland.ac.nz/breast-cancer ). Results confirmed that lymphatic drainage is most likely to occur to the axillary node field, and that there is significant likelihood of drainage to the internal mammary node field. The likelihood of lymphatic drainage from the whole breast to the axillary, internal mammary, infraclavicular, supraclavicular and interpectoral node fields were 98.2, 35.3, 1.7, 3.1, and 0.7%, respectively; whilst the probability of lymphatic drainage to multiple node fields was estimated to be 36.4%. Additionally, primary tumours are most likely to develop in the upper regions of the breast. The models developed provide quantitative estimates of lymphatic drainage of the breast, giving important insights into understanding breast cancer metastasis and have the potential to benefit both clinicians and patients during breast cancer diagnosis and treatment.


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Simulação por Computador , Vasos Linfáticos/patologia , Modelos Biológicos , Teorema de Bayes , Feminino , Humanos , Funções Verossimilhança
9.
J Anat ; 218(6): 652-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21453408

RESUMO

Current understanding of the lymphatics draining the breast is controversial, despite its known importance in the spread of breast cancer. Similarly, knowledge regarding the spatial distribution of primary tumours in the breast is limited. This study sought to test commonly held assumptions in this field, including: (i) that breast lymphatic drainage and tumour prevalence are symmetric between the left and right sides of the body, (ii) that males and females have the same drainage patterns and tumour prevalences, and (iii) that lymphatic drainage in the breast occurs independently to different node fields. This study has used lymphoscintigraphy data from 2304 breast cancer patients treated at the RPAH Medical Centre, Sydney, Australia. Symmetry of lymphatic drainage and tumour distribution as well as gender differences were tested using Fisher's exact test. Drainage independence was assessed using Fisher's exact test, and a multivariate probit model was used to test for drainage correlations. Results showed that the breasts are likely to have symmetric lymphatic drainage and tumour prevalence, and that there is no significant difference between males and females. Furthermore, results showed that direct lymphatic drainage of the breasts is likely to be independent between node fields. Collectively, these results serve to further our understanding of lymphatic anatomy and the distribution of tumours in the breast.


Assuntos
Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Mama/patologia , Sistema Linfático/patologia , Vasos Linfáticos/patologia , Feminino , Humanos , Linfonodos/patologia , Linfografia , Masculino , Modelos Biológicos , Análise Multivariada , Prevalência , Fatores Sexuais
10.
Artigo em Inglês | MEDLINE | ID: mdl-20836030

RESUMO

Biomechanical modeling of the breast is a burgeoning research field that has potential uses across a wide range of healthcare applications. This review describes recent developments regarding multi-modal breast image analysis, and outlines some of the key challenges that researchers face in introducing the models into the clinical arena. Deformable breast models have demonstrated capabilities across a wide range of breast cancer diagnoses and treatments. Specific applications include magnetic resonance (MR) image guided surgery, registration of x-ray and MR images, and breast reduction/augmentation surgery planning. Challenges lie in improving the fidelity of these models, which are presently simplistic and use many unverified parameters. Specific challenges include characterization of individual-specific mechanical properties of breast tissues, precise representation of loading and boundary constraints during different clinical procedures, and validation of modeling techniques used to represent key mechanical aspects such as the suspensory Cooper's ligaments. Scientists must also work towards translating their research tools into the clinical setting by developing efficient tools with user-friendly interactivity. Widespread adoption of such techniques has the potential to significantly reduce the numbers of misdiagnosed breast cancers and enhance surgical planning for patient treatment.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/fisiopatologia , Mama/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Mamografia/métodos , Modelos Biológicos , Técnica de Subtração , Animais , Fenômenos Biomecânicos , Módulo de Elasticidade , Feminino , Dureza , Humanos , Estresse Mecânico , Viscosidade
11.
Acad Radiol ; 15(11): 1425-36, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18995193

RESUMO

RATIONALE AND OBJECTIVES: Anatomically realistic biomechanical models of the breast potentially provide a reliable way of mapping tissue locations across medical images, such as mammograms, magnetic resonance imaging (MRI), and ultrasound. This work presents a new modeling framework that enables us to create biomechanical models of the breast that are customized to the individual. We demonstrate the framework's capabilities by creating models of the left breasts of two volunteers and tracking their deformations across MRIs. MATERIALS AND METHODS: We generate customized finite element models by automatically fitting geometrical models to segmented data from breast MRIs, and characterizing the in vivo mechanical properties (assuming homogeneity) of the breast tissues. For each volunteer, we identified the unloaded configuration by acquiring MRIs of the breast under neutral buoyancy (immersed in water). Such imaging is clearly not practical in the clinical setting; however, these previously unavailable data provide us with important data with which to validate models of breast biomechanics. Internal tissue features were identified in the neutral buoyancy images and tracked to the prone gravity-loaded state using the modeling framework. RESULTS: The models predicted deformations with root-mean-square errors of 4.2 and 3.6 mm in predicting the skin surface of the gravity-loaded state for each volunteer. Internal tissue features were tracked with a mean error of 3.7 and 4.7 mm for each volunteer. CONCLUSIONS: The models capture breast shape and internal deformations across the images with clinically acceptable accuracy. Further refinement of the framework and incorporation of more anatomic detail will make these models useful for breast cancer diagnosis.


Assuntos
Mama/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Adulto , Fenômenos Biomecânicos , Feminino , Humanos
12.
Med Image Comput Comput Assist Interv ; 11(Pt 2): 758-65, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18982673

RESUMO

We have developed a biomechanical model of the breast to simulate compression during mammographic imaging. The modelling framework was applied to a set of MR images of the breasts of a volunteer. Images of the uncompressed breast were segmented into skin and pectoral muscle, from which a finite element (FE) mesh of the left breast was generated using a nonlinear geometric fitting process. The compression plates within the breast MR coil were used to compress the volunteer's breasts by 32% in the latero-medial direction and the compressed breasts were subsequently imaged using MRI. The FE geometry of the uncompressed left breast was used to numerically simulate compression based on finite deformation elasticity coupled with contact mechanics, and individual-specific tissue properties. Accuracy of the simulated FE model was analysed by comparing the predicted surface data, and locations of three internal features within the compressed breast, with the equivalent experimental observations. Model predictions of the surface deformation yielded a RMS error of 1.5 mm. The Euclidean errors in predicting the locations of three internal features were 4.1 mm, 4.1 mm and 6.5 mm. Whilst the model reliably reproduced the compressive deformation, further investigations are required in order to test the validity of the underlying modelling assumptions. A reliable biomechanical model will provide a multi-modality imaging registration tool to help identify potential tumours observed between mammograms and other imaging modalities such as MRI or ultrasound.


Assuntos
Mama/anatomia & histologia , Mama/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Força Compressiva/fisiologia , Simulação por Computador , Elasticidade , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
13.
J Biomech ; 41(1): 69-77, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17727862

RESUMO

Mammography is currently the most widely used screening and diagnostic tool for breast cancer. Because X-ray images are 2D projections of a 3D object, it is not trivial to localise features identified in mammogram pairs within the breast volume. Furthermore, mammograms represent highly deformed configurations of the breast under compression, thus the tumour localisation process relies on the clinician's experience. Biomechanical models of the breast undergoing mammographic compressions have been developed to overcome this limitation. In this study, we present the development of a modelling framework that implements Coulomb's frictional law with a finite element analysis using a C(1)-continuous Hermite mesh. We compared two methods of this contact mechanics implementation: the penalty method, and the augmented Lagrangian method, the latter of which is more accurate but computationally more expensive compared to the former. Simulation results were compared with experimental data from a soft silicon gel phantom in order to evaluate the modelling accuracy of each method. Both methods resulted in surface-deformation root-mean-square errors of less than 2mm, whilst the maximum internal marker prediction error was less than 3mm when simulating two mammographic-like compressions. Simulation results were confirmed using the augmented Lagrangian method, which provided similar accuracy. We conclude that contact mechanics on soft elastic materials using the penalty method with an appropriate choice of the penalty parameters provides sufficient accuracy (with contact constraints suitably enforced), and may thus be useful for tracking breast tumours between clinical images.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/patologia , Mamografia/métodos , Modelos Biológicos , Algoritmos , Fenômenos Biomecânicos/métodos , Mama/fisiopatologia , Neoplasias da Mama/fisiopatologia , Simulação por Computador , Elasticidade , Feminino , Análise de Elementos Finitos , Fricção , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Pressão , Géis de Silicone/química , Estresse Mecânico
14.
Artigo em Inglês | MEDLINE | ID: mdl-18051114

RESUMO

Breast cancer detection, diagnosis and treatment increasingly involves images of the breast taken with different degrees of breast deformation. We introduce a new biomechanical modelling framework for predicting breast deformation and thus aiding the combination of information derived from the various images. In this paper, we focus on MR images of the breast under different loading conditions, and consider methods to map information between the images. We generate subject-specific finite element models of the breast by semi-automatically fitting geometrical models to segmented data from breast MR images, and characterizing the subject-specific mechanical properties of the breast tissues. We identified the unloaded reference configuration of the breast by acquiring MR images of the breast under neutral buoyancy (immersed in water). Such imaging is clearly not practical in the clinical setting, however this previously unavailable data provides us with important data with which to validate models of breast biomechanics, and provides a common configuration with which to refer and interpret all breast images. We demonstrate our modelling framework using a pilot study that was conducted to assess the mechanical performance of a subject-specific homogeneous biomechanical model in predicting deformations of the breast of a volunteer in a prone gravity-loaded configuration. The model captured the gross characteristics of the breast deformation with an RMS error of 4.2 mm in predicting the skin surface of the gravity-loaded shape, which included tissue displacements of over 20 mm. Internal tissue features identified from the MR images were tracked from the reference state to the prone gravity-loaded configuration with a mean error of 3.7 mm. We consider the modelling assumptions and discuss how the framework could be refined in order to further improve the tissue tracking accuracy.


Assuntos
Fenômenos Biomecânicos/métodos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Técnica de Subtração , Algoritmos , Inteligência Artificial , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Circulation ; 114(6): 536-42, 2006 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-16880326

RESUMO

BACKGROUND: The mechanisms that sustain ventricular fibrillation (VF) in the human heart remain unclear. Experimental models have demonstrated either a periodic source (mother rotor) or multiple wavelets as the mechanism underlying VF. The aim of this study was to map electrical activity from the entire ventricular epicardium of human hearts to establish the relative roles of these mechanisms in sustaining early human VF. METHODS AND RESULTS: In 10 patients undergoing cardiac surgery, VF was induced by burst pacing, and 20 to 40 seconds of epicardial activity was sampled (1 kHz) with a sock containing 256 unipolar contact electrodes connected to a UnEmap system. Signals were interpolated from the electrode sites to a fine regular grid (100x100 points), and dominant frequencies (DFs) were calculated with a fast Fourier transform with a moving 4096-ms window (10-ms increments). Epicardial phase was calculated at each grid point with the Hilbert transform, and phase singularities and activation wavefronts were identified at 10-ms intervals. Early human VF was sustained by large coherent wavefronts punctuated by periods of disorganized wavelet behavior. The initial fitted DF intercept was 5.11 +/- 0.25 (mean +/- SE) Hz (P < 0.0001), and DF increased at a rate of 0.018 +/- 0.005 Hz/s (P < 0.01) during VF, whereas combinations of homogeneous, heterogeneous, static, and mobile DF domains were observed for each of the patients. Epicardial reentry was present in all fibrillating hearts, typically with low numbers of phase singularities. In some cases, persistent phase singularities interacted with multiple complex wavelets; in other cases, VF was driven at times by a single reentrant wave that swept the entire epicardium for several cycles. CONCLUSIONS: Our data support both the mother rotor and multiple wavelet mechanisms of VF, which do not appear to be mutually exclusive in the human heart.


Assuntos
Eletrofisiologia , Sistema de Condução Cardíaco/fisiopatologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Mapeamento Potencial de Superfície Corporal , Ponte Cardiopulmonar , Eletrocardiografia , Eletrodos , Feminino , Ventrículos do Coração/inervação , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Pericárdio/fisiopatologia , Periodicidade , Fibrilação Ventricular/terapia
16.
Exp Physiol ; 91(2): 339-54, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16452121

RESUMO

Steep action potential duration (APD) restitution has been shown to facilitate wavebreak and ventricular fibrillation. The global APD restitution properties in cardiac patients are unknown. We report a combined clinical electrophysiology and computer modelling study to: (1) determine global APD restitution properties in cardiac patients; and (2) examine the interaction of the observed APD restitution with known arrhythmia mechanisms. In 14 patients aged 52-85 years undergoing routine cardiac surgery, 256 electrode epicardial mapping was performed. Activation-recovery intervals (ARI; a surrogate for APD) were recorded over the entire ventricular surface. Mono-exponential restitution curves were constructed for each electrode site using a standard S1-S2 pacing protocol. The median maximum restitution slope was 0.91, with 27% of all electrode sites with slopes<0.5, 29% between 0.5 and 1.0, and 20% between 1.0 and 1.5. Eleven per cent of restitution curves maintained slope>1 over a range of diastolic intervals of at least 30 ms; and 0.3% for at least 50 ms. Activation-recovery interval restitution was spatially heterogeneous, showing regional organization with multiple discrete areas of steep and shallow slope. We used a simplified computer model of 2-D cardiac tissue to investigate how heterogeneous APD restitution can influence vulnerability to, and stability of re-entry. Our model showed that heterogeneity of restitution can act as a potent arrhythmogenic substrate, as well as influencing the stability of re-entrant arrhythmias. Global epicardial mapping in humans showed that APD restitution slopes were organized into regions of shallow and steep slopes. This heterogeneous organization of restitution may provide a substrate for arrhythmia.


Assuntos
Mapeamento Potencial de Superfície Corporal , Cardiopatias/fisiopatologia , Coração/fisiopatologia , Modelos Cardiovasculares , Potenciais de Ação/fisiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Simulação por Computador , Doença das Coronárias/fisiopatologia , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Cardiopatias/tratamento farmacológico , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA