Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39317232

RESUMO

OBJECTIVE: To present a long short-term memory (LSTM) network-based dose calculation method for magnetic resonance (MR)-guided proton therapy. APPROACH: 35 planning computed tomography (CT) images of prostate cancer patients were collected for Monte Carlo (MC) dose calculation under a perpendicular 1.5 T magnetic field. Proton pencil beams (PB) at three energies (150, 175, and 200 MeV) were simulated (7560 PBs at each energy). A 3D relative stopping power (RSP) cuboid covering the extent of the PB dose was extracted and given as input to the LSTM model, yielding a 3D predicted PB dose. Three single-energy (SE) LSTM models were trained separately on the corresponding 150/175/200 MeV datasets and a multi-energy (ME) LSTM model with an energy embedding layer was trained on either the combined dataset with three energies or a continuous energy (CE) dataset with 1 MeV steps ranging from 125 to 200 MeV. For each model, training and validation involved 25 patients and 10 patients were for testing. Two single field uniform dose prostate treatment plans were optimized and recalculated with MC and the CE model. RESULTS: Test results of all PBs from the three SE models showed a mean gamma passing rate (2%/2mm, 10% dose cutoff) above 99.9% with an average center-of-mass (COM) discrepancy below 0.4 mm between predicted and simulated trajectories. The ME model showed a mean gamma passing rate exceeding 99.8% and a COM discrepancy of less than 0.5 mm at the three energies. Treatment plan recalculation by the CE model yielded gamma passing rates of 99.6% and 97.9%. The inference time of the models was 9-10 ms per PB. SIGNIFICANCE: LSTM models for proton dose calculation in a magnetic field were developed and showed promising accuracy and efficiency for prostate cancer patients.

2.
Med Phys ; 48(4): 1893-1908, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33332644

RESUMO

PURPOSE: To investigate the feasibility and accuracy of proton dose calculations with artificial neural networks (ANNs) in challenging three-dimensional (3D) anatomies. METHODS: A novel proton dose calculation approach was designed based on the application of a long short-term memory (LSTM) network. It processes the 3D geometry as a sequence of two-dimensional (2D) computed tomography slices and outputs a corresponding sequence of 2D slices that forms the 3D dose distribution. The general accuracy of the approach is investigated in comparison to Monte Carlo reference simulations and pencil beam dose calculations. We consider both artificial phantom geometries and clinically realistic lung cases for three different pencil beam energies. RESULTS: For artificial phantom cases, the trained LSTM model achieved a 98.57% γ-index pass rate ([1%, 3 mm]) in comparison to MC simulations for a pencil beam with initial energy 104.25 MeV. For a lung patient case, we observe pass rates of 98.56%, 97.74%, and 94.51% for an initial energy of 67.85, 104.25, and 134.68 MeV, respectively. Applying the LSTM dose calculation on patient cases that were fully excluded from the training process yields an average γ-index pass rate of 97.85%. CONCLUSIONS: LSTM networks are well suited for proton dose calculation tasks. Further research, especially regarding model generalization and computational performance in comparison to established dose calculation methods, is warranted.


Assuntos
Terapia com Prótons , Prótons , Algoritmos , Humanos , Memória de Curto Prazo , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA