Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 113(5): 967-973, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35483539

RESUMO

PURPOSE: The high potential of microbeam radiation therapy (MRT) in improving tumor control while reducing side effects has been shown by numerous preclinical studies. MRT offers a widened therapeutic window by using the periodical spatial fractionation of synchrotron generated x-rays into an array of intense parallel microbeams. MRT now enters a clinical transfer phase. As proof of principle and cornerstone for the safe clinical transfer of MRT, we conducted a "first in dog" trial under clinical conditions. In this report, we evaluated whether a 3-dimensional conformal MRT can be safely delivered as exclusive radiosurgical treatment in animal patients METHODS AND MATERIALS: We irradiated a 17.5-kg French bulldog for a spontaneous brain tumor (glioma suspected on magnetic resonance imaging) with conformal high-dose-rate microbeam arrays (50-µm-wide microbeams, replicated with a pitch of 400 µm) of synchrotron-generated x-rays. The dose prescription adjusted a minimal cumulated valley dose of 2.8 Gy to the plnning target volume (PTV) (cinical target volume (CTV)+ 1 mm). Thus, each beam delivered 20 to 25 Gy to the target as peak doses, and ∼1 Gy as valley doses RESULTS: The treatment was successfully delivered. Clinical follow-up over 3 months showed a significant improvement of the dog's quality of life: the symptoms disappeared. Magnetic resonance imaging, performed 3 months after irradiation, revealed reduction in tumor size (-87.4%) and mass effect with normalization of the left lateral ventricle. CONCLUSIONS: To our knowledge, this neuro-oncologic veterinary trial is the first 3-dimensional conformal synchrotron x-ray MRT treatment of a spontaneous intracranial tumor in a large animal. It is an essential last step toward the clinical transfer of MRT in the near future to demonstrate the feasibility and safety of treating deep-seated tumors using synchrotron-generated microbeams.


Assuntos
Neoplasias Encefálicas , Glioma , Radiocirurgia , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/veterinária , Cães , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/radioterapia , Qualidade de Vida , Radiocirurgia/métodos , Síncrotrons
2.
Sci Rep ; 9(1): 17082, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31745153

RESUMO

The functional roles of the Caudate nucleus (Cd) are well known. Selective Cd lesions can be found in neurological disorders. However, little is known about the dynamics of the behavioral changes during progressive Cd ablation. Current stereotactic radiosurgery technologies allow the progressive ablation of a brain region with limited adverse effects in surrounding normal tissues. This could be of high interest for the study of the modified behavioral functions in relation with the degree of impairment of the brain structures. Using hypofractionated stereotactic radiotherapy combined with synchrotron microbeam radiation, we investigated, during one year after irradiation, the effects of unilateral radio-ablation of the right Cd on the behavior of Yucatan minipigs. The right Cd was irradiated to a minimal dose of 35.5 Gy delivered in three fractions. MRI-based morphological brain integrity and behavioral functions, i.e. locomotion, motivation/hedonism were assessed. We detected a progressive radio-necrosis leading to a quasi-total ablation one year after irradiation, with an additional alteration of surrounding areas. Transitory changes in the motivation/hedonism were firstly detected, then on locomotion, suggesting the influence of different compensatory mechanisms depending on the functions related to Cd and possibly some surrounding areas. We concluded that early behavioral changes related to eating functions are relevant markers for the early detection of ongoing lesions occurring in Cd-related neurological disorders.


Assuntos
Comportamento Animal/efeitos da radiação , Encéfalo/patologia , Núcleo Caudado/patologia , Irradiação Craniana/efeitos adversos , Comportamento Alimentar/efeitos da radiação , Locomoção/efeitos da radiação , Lesões por Radiação/patologia , Animais , Encéfalo/efeitos da radiação , Núcleo Caudado/efeitos da radiação , Masculino , Lesões por Radiação/etiologia , Suínos , Porco Miniatura , Síncrotrons
3.
Phys Med ; 65: 227-237, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31574356

RESUMO

Microbeam radiation therapy (MRT) uses synchrotron arrays of X-ray microbeams to take advantage of the spatial fractionation effect for normal tissue sparing. In this study, radiochromic film dosimetry was performed for a treatment where MRT is introduced as a dose boost in a hypofractionated stereotactic radiotherapy (SRT) scheme. The isocenter dose was measured using an ionization chamber and two dimensional dose distributions were determined using radiochromic films. To compare the measured dose distribution to the MRT treatment plan, peak and valley were displayed in separate dosemaps. The measured and computed isocenter doses were compared and a two-dimensional 2%/2 mm normalized γ-index analysis with a 90% passing rate criterion was computed. For SRT, a difference of 2.6% was observed in the dose at the isocenter from the treatment plan and film measurement, with a passing rate of 96% for the γ-index analysis. For MRT, peak and valley doses differences of 25.6% and 8.2% were observed, respectively but passing rates of 96% and 90% respectively were obtained from the normalized γ-index maps. The differences in isocenter doses measured in MRT should be further investigated. We present the methodology of patient specific quality assurance (QA) for studying MRT dose distributions and discuss ideas to improve absolute dosimetry. This patient specific QA will be used for large animal trials quality assurance where MRT will be administered as a dose boost in conventional SRT. The observed remaining discrepancies should be studied against approximations in the TPS phantom materials, beams characteristics or film read-out procedures.


Assuntos
Dosimetria Fotográfica/métodos , Radioterapia/métodos , Neoplasias Encefálicas/radioterapia , Fracionamento da Dose de Radiação , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Síncrotrons , Raios X
4.
Radiother Oncol ; 139: 56-61, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31307824

RESUMO

This paper reviews the current state of the art of an emerging form of radiosurgery dedicated to brain tumour treatment and which operates at very high dose rate (kGy·s-1). Microbeam Radiation Therapy uses synchrotron-generated X-rays which triggered normal tissue sparing partially mediated by FLASH effect.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Síncrotrons , Animais , Neoplasias Encefálicas/irrigação sanguínea , Protocolos Clínicos , Modelos Animais de Doenças , Humanos , Raios X
5.
J Synchrotron Radiat ; 23(Pt 5): 1180-90, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27577773

RESUMO

Microbeam radiation therapy (MRT) is a novel irradiation technique for brain tumours treatment currently under development at the European Synchrotron Radiation Facility in Grenoble, France. The technique is based on the spatial fractionation of a highly brilliant synchrotron X-ray beam into an array of microbeams using a multi-slit collimator (MSC). After promising pre-clinical results, veterinary trials have recently commenced requiring the need for dedicated quality assurance (QA) procedures. The quality of MRT treatment demands reproducible and precise spatial fractionation of the incoming synchrotron beam. The intensity profile of the microbeams must also be quickly and quantitatively characterized prior to each treatment for comparison with that used for input to the dose-planning calculations. The Centre for Medical Radiation Physics (University of Wollongong, Australia) has developed an X-ray treatment monitoring system (X-Tream) which incorporates a high-spatial-resolution silicon strip detector (SSD) specifically designed for MRT. In-air measurements of the horizontal profile of the intrinsic microbeam X-ray field in order to determine the relative intensity of each microbeam are presented, and the alignment of the MSC is also assessed. The results show that the SSD is able to resolve individual microbeams which therefore provides invaluable QA of the horizontal field size and microbeam number and shape. They also demonstrate that the SSD used in the X-Tream system is very sensitive to any small misalignment of the MSC. In order to allow as rapid QA as possible, a fast alignment procedure of the SSD based on X-ray imaging with a low-intensity low-energy beam has been developed and is presented in this publication.

6.
Med Phys ; 43(6): 3157-3167, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27277061

RESUMO

PURPOSE: Upcoming veterinary trials in microbeam radiation therapy (MRT) demand for more advanced irradiation techniques than in preclinical research with small animals. The treatment of deep-seated tumors in cats and dogs with MRT requires sophisticated irradiation geometries from multiple ports, which impose further efforts to spare the normal tissue surrounding the target. METHODS: This work presents the development and benchmarking of a precise patient alignment protocol for MRT at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF). The positioning of the patient prior to irradiation is verified by taking x-ray projection images from different angles. RESULTS: Using four external fiducial markers of 1.7 mm diameter and computed tomography-based treatment planning, a target alignment error of less than 2 mm can be achieved with an angular deviation of less than 2(∘). Minor improvements on the protocol and the use of smaller markers indicate that even a precision better than 1 mm is technically feasible. Detailed investigations concerning the imaging dose lead to the conclusion that doses for skull radiographs lie in the same range as dose reference levels for human head radiographs. A currently used online dose monitor for MRT has been proven to give reliable results for the imaging beam. CONCLUSIONS: The ESRF biomedical beamline ID17 is technically ready to apply conformal image-guided MRT from multiple ports to large animals during future veterinary trials.

7.
J Synchrotron Radiat ; 23(1): 339-43, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698083

RESUMO

A fast positioning method for brain tumor microbeam irradiations for preclinical studies at third-generation X-ray sources is described. The three-dimensional alignment of the animals relative to the X-ray beam was based on the X-ray tomography multi-slices after iodine infusion. This method used pink-beam imaging produced by the ID17 wiggler. A graphical user interface has been developed in order to define the irradiation parameters: field width, height, number of angles and X-ray dose. This study is the first reporting an image guided method for soft tissue synchrotron radiotherapy. It allowed microbeam radiation therapy irradiation fields to be reduced by a factor of ∼20 compared with previous studies. It permitted more targeted, more efficient brain tumor microbeam treatments and reduces normal brain toxicity of the radiation treatment.


Assuntos
Neoplasias Encefálicas/radioterapia , Animais , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética , Ratos , Ratos Endogâmicos F344
8.
PLoS One ; 8(1): e53549, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23341950

RESUMO

Synchrotron-generated X-ray microplanar beams (microbeams) are characterized by the ability to deliver extremely high doses of radiation to spatially restricted volumes of tissue. Minimal dose spreading outside the beam path provides an exceptional degree of protection from radio-induced damage to the neurons and glia adjacent to the microscopic slices of tissue irradiated. The preservation of cortical architecture following high-dose microbeam irradiation and the ability to induce non-invasively the equivalent of a surgical cut over the cortex is of great interest for the development of novel experimental models in neurobiology and new treatment avenues for a variety of brain disorders. Microbeams (size 100 µm/600 µm, center-to-center distance of 400 µm/1200 µm, peak entrance doses of 360-240 Gy/150-100 Gy) delivered to the sensorimotor cortex of six 2-month-old naïve rats generated histologically evident cortical transections, without modifying motor behavior and weight gain up to 7 months. Microbeam transections of the sensorimotor cortex dramatically reduced convulsive seizure duration in a further group of 12 rats receiving local infusion of kainic acid. No subsequent neurological deficit was associated with the treatment. These data provide a novel tool to study the functions of the cortex and pave the way for the development of new therapeutic strategies for epilepsy and other neurological diseases.


Assuntos
Convulsões/prevenção & controle , Convulsões/fisiopatologia , Córtex Somatossensorial/patologia , Córtex Somatossensorial/fisiopatologia , Síncrotrons , Animais , Histonas/metabolismo , Imuno-Histoquímica , Masculino , Fosfoproteínas/metabolismo , Ratos , Ratos Wistar , Teste de Desempenho do Rota-Rod , Convulsões/patologia , Coloração e Rotulagem , Raios X
9.
Neurobiol Dis ; 51: 152-60, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23159741

RESUMO

Radiotherapy has shown some efficacy for epilepsies but the insufficient confinement of the radiation dose to the pathological target reduces its indications. Synchrotron-generated X-rays overcome this limitation and allow the delivery of focalized radiation doses to discrete brain volumes via interlaced arrays of microbeams (IntMRT). Here, we used IntMRT to target brain structures involved in seizure generation in a rat model of absence epilepsy (GAERS). We addressed the issue of whether and how synchrotron radiotherapeutic treatment suppresses epileptic activities in neuronal networks. IntMRT was used to target the somatosensory cortex (S1Cx), a region involved in seizure generation in the GAERS. The antiepileptic mechanisms were investigated by recording multisite local-field potentials and the intracellular activity of irradiated S1Cx pyramidal neurons in vivo. MRI and histopathological images displayed precise and sharp dose deposition and revealed no impairment of surrounding tissues. Local-field potentials from behaving animals demonstrated a quasi-total abolition of epileptiform activities within the target. The irradiated S1Cx was unable to initiate seizures, whereas neighboring non-irradiated cortical and thalamic regions could still produce pathological oscillations. In vivo intracellular recordings showed that irradiated pyramidal neurons were strongly hyperpolarized and displayed a decreased excitability and a reduction of spontaneous synaptic activities. These functional alterations explain the suppression of large-scale synchronization within irradiated cortical networks. Our work provides the first post-irradiation electrophysiological recordings of individual neurons. Altogether, our data are a critical step towards understanding how X-ray radiation impacts neuronal physiology and epileptogenic processes.


Assuntos
Epilepsia Tipo Ausência/radioterapia , Rede Nervosa/efeitos da radiação , Córtex Somatossensorial/efeitos da radiação , Animais , Modelos Animais de Doenças , Eletroencefalografia , Epilepsia Tipo Ausência/fisiopatologia , Feminino , Rede Nervosa/fisiopatologia , Ratos , Córtex Somatossensorial/fisiopatologia , Terapia por Raios X/métodos
10.
J Synchrotron Radiat ; 18(Pt 5): 689-96, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21862846

RESUMO

High-resolution analyser-based X-ray imaging computed tomography (HR ABI-CT) findings on in vitro human breast cancer are compared with histopathology, mammography, computed tomography (CT) and magnetic resonance imaging. The HR ABI-CT images provided significantly better low-contrast visibility compared with the standard radiological images. Fine cancer structures indistinguishable and superimposed in mammograms were seen, and could be matched with the histopathological results. The mean glandular dose was less than 1 mGy in mammography and 12-13 mGy in CT and ABI-CT. The excellent visibility of in vitro breast cancer suggests that HR ABI-CT may have a valuable role in the future as an adjunct or even alternative to current breast diagnostics, when radiation dose is further decreased, and compact synchrotron radiation sources become available.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Tomografia Computadorizada por Raios X/métodos , Mama/patologia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Doses de Radiação , Síncrotrons
11.
J Synchrotron Radiat ; 17(3): 325-31, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20400830

RESUMO

A fast 50 microm-accuracy alignment procedure has been developed for the radiosurgery of brain lesions in rats, using microbeam radiation therapy. In vivo imaging was performed using the pink beam (35-60 keV) produced by the ID17 wiggler at the ESRF opened at 120 mm and filtered. A graphical user interface has been developed in order to define the irradiation field size and to position the target with respect to the skull structures observed in X-ray images. The method proposed here allows tremendous time saving by skipping the swap from white beam to monochromatic beam and vice versa. To validate the concept, the somatosensory cortex or thalamus of GAERS rats were irradiated under several ports using this alignment procedure. The magnetic resonance images acquired after contrast agent injection showed that the irradiations were selectively performed in these two expected brain regions. Image-guided microbeam irradiations have therefore been realised for the first time ever, and, thanks to this new development, the ID17 biomedical beamline provides a major tool allowing brain radiosurgery trials on animal patients.


Assuntos
Encéfalo/efeitos da radiação , Animais , Encéfalo/anatomia & histologia , Calibragem , Imageamento por Ressonância Magnética , Radiocirurgia , Ratos , Interface Usuário-Computador
12.
PLoS One ; 5(2): e9028, 2010 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-20140254

RESUMO

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy). Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range), targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3) in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing surrounding tissues. The use of synchrotron-generated X-rays enables delivery of high doses for destruction of small focal regions in human brains, with sharper dose fall-offs than those described in any other conventional radiation therapy.


Assuntos
Doses de Radiação , Radiocirurgia/métodos , Síncrotrons , Animais , Comportamento Animal/efeitos da radiação , Encéfalo/metabolismo , Encéfalo/patologia , Encéfalo/efeitos da radiação , Proteína Glial Fibrilar Ácida/metabolismo , Humanos , Imuno-Histoquímica , Imageamento por Ressonância Magnética , Método de Monte Carlo , Ratos , Fatores de Tempo , Raios X
13.
Phys Med Biol ; 52(8): 2197-211, 2007 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-17404464

RESUMO

The aim of this study was to introduce high-resolution computed tomography (CT) of breast tumours using the diffraction-enhanced x-ray imaging (DEI) technique and to compare results with radiological and histo-pathological examinations. X-ray CT images of tumour-bearing breast tissue samples were acquired by monochromatic synchrotron radiation (SR). Due to the narrow beam and a large sample-to-detector distance scattering is rejected in the absorption contrast images (SR-CT). Large contrast enhancement is achieved by the use of the DEI-CT method, where the effects of refraction and scatter rejection are analysed by crystal optics. Clinical mammograms and CT images were recorded as reference material for a radiological examination. Three malignant and benign samples were studied in detail. Their radiographs were compared with optical images of stained histological sections. The DEI-CT images map accurately the morphology of the samples, including collagen strands and micro-calcifications of dimensions less than 0.1 mm. Histo-pathological examination and reading of the radiographs were done independently, and the conclusions were in general agreement. High-resolution DEI-CT images show strong contrast and permit visualization of details invisible in clinical radiographs. The radiation dose may be reduced by an order of magnitude without compromising image quality, which would make possible clinical in vivo DEI-CT with future compact SR sources.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Difração de Raios X/métodos , Feminino , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Appl Physiol (1985) ; 100(6): 1964-73, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16469938

RESUMO

We studied the kinetics of proximal and distal bronchial response to histamine aerosol in healthy anesthetized and mechanically ventilated rabbits up to 60 min after histamine administration using a novel xenon-enhanced synchrotron radiation computed tomography imaging technique. Individual proximal airway constriction was assessed by measuring the luminal cross-sectional area. Distal airway obstruction was estimated by measuring the ventilated alveolar area after inhaled xenon administration. Respiratory system conductance was assessed continuously. Proximal airway cross-sectional area decreased by 57% of the baseline value by 20 min and recovered gradually but incompletely within 60 min. The ventilated alveolar area decreased immediately after histamine inhalation by 55% of baseline value and recovered rapidly thereafter. The results indicate that the airway reaction to inhaled histamine and the subsequent recovery are significantly slower in proximal than in distal bronchi in healthy rabbit. The findings suggest that physiological reaction mechanisms to inhaled histamine in the airway walls of large and small bronchi are not similar.


Assuntos
Histamina/farmacologia , Alvéolos Pulmonares/fisiologia , Ventilação Pulmonar/fisiologia , Tomografia Computadorizada por Raios X/métodos , Administração por Inalação , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/patologia , Obstrução das Vias Respiratórias/fisiopatologia , Animais , Asma/patologia , Asma/fisiopatologia , Fenômenos Biomecânicos , Brônquios/anatomia & histologia , Brônquios/fisiologia , Broncoconstrição/efeitos dos fármacos , Broncoconstrição/fisiologia , Histamina/administração & dosagem , Histamina/farmacocinética , Processamento de Imagem Assistida por Computador , Masculino , Alvéolos Pulmonares/anatomia & histologia , Alvéolos Pulmonares/efeitos dos fármacos , Coelhos , Síncrotrons , Volume de Ventilação Pulmonar/fisiologia , Fatores de Tempo , Xenônio
15.
Eur Heart J ; 26(13): 1284-91, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15734769

RESUMO

AIMS: Synchrotron radiation angiography (SRA) is a novel tool for minimally invasive coronary artery imaging. The method uses subtraction of two images produced at energies bracketing the iodine K-edge after intravenous infusion of iodinated contrast agent. We investigated the accuracy of SRA for detecting in-stent restenosis (ISR). METHODS AND RESULTS: We recruited 57 men, 4-6 months after successful PTCA. We visualized the right coronary artery (RCA) in 27 patients with 36 stented segments [12 segments with ISR>50% by quantitative coronary angiography (QCA)], and the left anterior descending artery (LAD) in 30 patients with 37 stented segments (10 ISR). SRA and QCA were performed within 2 days of each other. Two experienced observers unaware of QCA data evaluated the SRA results. Image quality was good or excellent in most patients. Global sensitivity was 64%, specificity was 95%, and positive and negative predictive values were approximately 85%. Inter-observer kappa concordance coefficient was 0.86. False negatives involved short eccentric lesions and superimposed segments, most frequently of the LAD. False positives occurred in intermediate stenoses slightly overestimated by SRA. CONCLUSION: In men, this minimally invasive approach, using small radiation doses, detects significant ISR in the RCA, but the LAD poses difficulties because of superimposition with others structures.


Assuntos
Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Stents , Síncrotrons/normas , Adulto , Idoso , Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
16.
Phys Med Biol ; 50(4): 725-40, 2005 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15773630

RESUMO

A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-stent restenosis. For each patient, diagnosis has been performed on the synchrotron radiation images and monitored with the conventional selective coronary angiography method taken as the golden standard. In this paper, the methods of image processing and the results of the quantitative analysis are described. Image processing includes beam harmonic contamination correction, spatial deconvolution and the extraction of a 'contrast' and a 'tissue' image from each couple of radiograms simultaneously acquired at energies bracketing the K-edge of iodine. Quantitative analysis includes the estimation of the vessel diameter, the calculation of the absolute iodine concentration profiles along the coronary arteries and the stenosis degree measurement.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Armazenamento e Recuperação da Informação/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reestenose Coronária/complicações , Oclusão de Enxerto Vascular/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Síncrotrons
17.
Phys Med Biol ; 50(1): 1-11, 2005 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-15715418

RESUMO

The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O2 gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.


Assuntos
Pulmão/patologia , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Gases , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Modelos Estatísticos , Oxigênio/metabolismo , Imagens de Fantasmas , Troca Gasosa Pulmonar , Coelhos , Testes de Função Respiratória , Software , Xenônio
18.
J Cereb Blood Flow Metab ; 25(2): 145-53, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15678122

RESUMO

The authors previously provided evidence of synchrotron radiation computed tomography (SRCT) efficacy for quantitative in vivo brain perfusion measurements using monochromatic X-ray beams. However, this technique was limited for small-animal studies by partial volume effects. In this paper, high-resolution absolute cerebral blood volume and blood-brain barrier permeability coefficient measurements were obtained on a rat glioma model using SRCT and a CCD camera (47x47 microm2 pixel size). This is the first report of in vivo high-resolution brain vasculature parameter assessment. The work gives interesting perspectives to quantify brain hemodynamic changes accurately in healthy and pathological small animals.


Assuntos
Barreira Hematoencefálica/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Permeabilidade , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Encéfalo/irrigação sanguínea , Linhagem Celular Tumoral , Circulação Cerebrovascular/fisiologia , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA