Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Endocrinol Metab ; 105(4)2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31714583

RESUMO

BACKGROUND: Postbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective. METHODS: Patients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose monitor (CGM, Dexcom) driving a patch infusion pump (Insulet) filled with liquid investigational glucagon (Xeris) or placebo (vehicle). Sensor/plasma glucose responses to mixed meal were assessed during 2 study visits. The system delivered up to 2 doses of study drug (300/150 µg glucagon or equal-volume vehicle) if triggered by the algorithm. Rescue dextrose was given for plasma glucose <55 mg/dL or neuroglycopenia. RESULTS: Twelve participants (11 females/1 male, age 52 ± 2, 8 ± 1 years postsurgery, mean ± SEM) completed all visits. Predictive hypoglycemia alerts prompted automated drug delivery postmeal, when sensor glucose was 114 ± 7 vs 121 ± 5 mg/dL (P = .39). Seven participants required rescue glucose after vehicle but not glucagon (P = .008). Five participants had severe hypoglycemia (<55 mg/dL) after vehicle but not glucagon (P = .03). Nadir plasma glucose was higher with glucagon vs vehicle (67 ± 3 vs 59 ± 2 mg/dL, P = .004). Plasma glucagon rose after glucagon delivery (1231 ± 187 vs 16 ± 1 pg/mL at 30 minutes, P = .001). No rebound hyperglycemia occurred. Transient infusion site discomfort was reported with both glucagon (n = 11/12) and vehicle (n = 10/12). No other adverse events were observed. CONCLUSION: A CGM-guided closed-loop rescue system can detect imminent hypoglycemia and deliver glucagon, reducing severe hypoglycemia in PBH. CLINICAL TRIALS REGISTRATION: NCT03255629.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Fármacos Gastrointestinais/administração & dosagem , Glucagon/administração & dosagem , Hipoglicemia/tratamento farmacológico , Obesidade Mórbida/cirurgia , Algoritmos , Estudos Cross-Over , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Hipoglicemia/etiologia , Hipoglicemia/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico
2.
Diabetes Technol Ther ; 20(2): 127-139, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29355439

RESUMO

BACKGROUND: Postbariatric hypoglycemia (PBH) is a complication of bariatric surgery with limited therapeutic options. We developed an event-based system to predict and detect hypoglycemia based on continuous glucose monitor (CGM) data and recommend delivery of minidose liquid glucagon. METHODS: We performed an iterative development clinical study employing a novel glucagon delivery system: a Dexcom CGM connected to a Windows tablet running a hypoglycemia prediction algorithm and an Omnipod pump filled with an investigational stable liquid glucagon formulation. Meal tolerance testing was performed in seven participants with PBH and history of neuroglycopenia. Glucagon was administered when hypoglycemia was predicted. Primary outcome measures included the safety and feasibility of this system to predict and prevent severe hypoglycemia. Secondary outcomes included hypoglycemia prediction by the prediction algorithm, minimization of time below hypoglycemia threshold using glucagon, and prevention of rebound hyperglycemia. RESULTS: The hypoglycemia prediction algorithm alerted for impending hypoglycemia in the postmeal state, prompting delivery of glucagon (150 µg). After observations of initial incomplete efficacy to prevent hypoglycemia in the first two participants, system modifications were implemented: addition of PBH-specific detection algorithm, increased glucagon dose (300 µg), and a second glucagon dose if needed. These modifications, together with rescue carbohydrates provided to some participants, contributed to progressive improvements in glucose time above the hypoglycemia threshold (75 mg/dL). CONCLUSIONS: Preliminary results indicate that our event-based automatic monitoring algorithm successfully predicted likely hypoglycemia. Minidose glucagon therapy was well tolerated, without prolonged or severe hypoglycemia, and without rebound hyperglycemia.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Glucagon/uso terapêutico , Hipoglicemia/tratamento farmacológico , Adulto , Algoritmos , Glicemia , Feminino , Glucagon/administração & dosagem , Humanos , Hipoglicemia/sangue , Hipoglicemia/etiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA