Radiol Phys Technol ; 12(4): 374-381, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31468370

RESUMO

This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.


Assuntos
Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/instrumentação , Imagens de Fantasmas , Doses de Radiação , Abdome/irrigação sanguínea , Adulto , Feminino , Humanos , Pulmão/irrigação sanguínea , Masculino , Pelve/irrigação sanguínea , Estudos Retrospectivos , Crânio/irrigação sanguínea
2.
Sci Rep ; 9(1): 1459, 2019 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-30728394

RESUMO

Synthesized 2D images can be reconstructed from tomosynthesis images in breast imaging. This study aims to investigate the diagnostic efficacy of synthesized 2D images (C-View) in comparison to full field digital mammography (FFDM) when used with digital breast tomosynthesis (DBT) in multi-ethnic Malaysian population. FFDM and C-View images (n = 380) were independently evaluated by three readers through Breast Imaging Reporting and Data System (BI-RADS) categorisation, breast density and lesion characterisation. Statistical analysis was done comparing sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of C-View + DBT with FFDM + DBT as standard of reference. Very good interreader agreement in BI-RADS category and density assessment between C-View + DBT and FFDM + DBT, with high sensitivity, specificity, PPV and NPV of C-View + DBT when compared with FFDM + DBT. There was comparable PPV between C-View + DBT and FFDM + DBT, with histopathology as gold standard. High level of interreader agreement in BI-RADS category and density assessment for FFDM + DBT and C-View + DBT. There was good agreement between FFDM + DBT and C-View + DBT in mass characterization, and almost perfect agreement in calcification and asymmetric density. 52.2% lower radiation dose incurred when using C-View + DBT. Hence, synthesized 2D images are comparable to FFDM with reduction in radiation dose within the limits of Malaysian multi-ethnic population.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Neoplasias da Mama/etnologia , Detecção Precoce de Câncer , Feminino , Humanos , Malásia/etnologia , Mamografia , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
J Radiol Prot ; 37(4): 883-906, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28836506

RESUMO

This paper sets out guidelines for managing radiation exposure incidents involving patients in diagnostic and interventional radiology. The work is based on collation of experiences from representatives of international and national organizations for radiologists, medical physicists, radiographers, regulators, and equipment manufacturers, derived from an International Atomic Energy Agency Technical Meeting. More serious overexposures can result in skin doses high enough to produce tissue reactions, in interventional procedures and computed tomography, most notably from perfusion studies. A major factor involved has been deficiencies in training of staff in operation of equipment and optimization techniques. The use of checklists and time outs before procedures commence, and dose alerts when critical levels are reached during procedures, can provide safeguards to reduce the risks of these effects occurring. However, unintended and accidental overexposures resulting in relatively small additional doses can take place in any diagnostic or interventional x-ray procedure and it is important to learn from errors that occur, as these may lead to increased risks of stochastic effects. Such events may involve the wrong examinations, procedural errors, or equipment faults. Guidance is given on prevention, investigation, and dose calculation for radiology exposure incidents within healthcare facilities. Responsibilities should be clearly set out in formal policies, and procedures should be in place to ensure that root causes are identified and deficiencies addressed. When an overexposure of a patient or an unintended exposure of a foetus occurs, the foetal, organ, skin, and/or effective dose may be estimated from exposure data. When doses are very low, generic values for the examination may be sufficient, but a full assessment of doses to all exposed organs and tissues may sometimes be required. The use of general terminology to describe risks from stochastic effects is recommended rather than the calculation of numerical values, as these are misleading when applied to individuals.


Assuntos
Diagnóstico por Imagem , Exposição à Radiação , Lesões por Radiação/diagnóstico , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Congressos como Assunto , Humanos , Radiografia Intervencionista , Medição de Risco
4.
Phys Med ; 32(11): 1466-1474, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27842982

RESUMO

The purpose of this study is to measure patient skin dose in tangential breast radiotherapy. Treatment planning dose calculation algorithm such as Pencil Beam Convolution (PBC) and in vivo dosimetry techniques such as radiochromic film can be used to accurately monitor radiation doses at tissue depths, but they are inaccurate for skin dose measurement. A MOSFET-based (MOSkin) detector was used to measure skin dose in this study. Tangential breast radiotherapies ("bolus" and "no bolus") were simulated on an anthropomorphic phantom and the skin doses were measured. Skin doses were also measured in 13 patients undergoing each of the techniques. In the patient study, the EBT2 measurements and PBC calculation tended to over-estimate the skin dose compared with the MOSkin detector (p<0.05) in the "no bolus radiotherapy". No significant differences were observed in the "bolus radiotherapy" (p>0.05). The results from patients were similar to that of the phantom study. This shows that the EBT2 measurement and PBC calculation, while able to predict accurate doses at tissue depths, are inaccurate in predicting doses at build-up regions. The clinical application of the MOSkin detectors showed that the average total skin doses received by patients were 1662±129cGy (medial) and 1893±199cGy (lateral) during "no bolus radiotherapy". The average total skin doses were 4030±72cGy (medial) and 4004±91cGy (lateral) for "bolus radiotherapy". In some cases, patient skin doses were shown to exceed the dose toxicity level for skin erythema. Hence, a suitable device for in vivo dosimetry is necessary to accurately determine skin dose.


Assuntos
Neoplasias da Mama/radioterapia , Radiometria/instrumentação , Pele/efeitos da radiação , Algoritmos , Humanos , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Rotação
5.
Australas Phys Eng Sci Med ; 38(3): 493-501, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26346030

RESUMO

It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representing 23 countries. As in previous surveys the questionnaire covered seven themes: 1 education, training and professional certification, 2 staffing, 3 typical tasks, 4 professional organisations, 5 resources, 6 research and teaching, and 7 job satisfaction. The response rate of 100% is a result of performing a survey through a network, which allows easy follow-up. The replies cover 4841 ROMPs in 23 countries. Compared to 2008, the number of medical physicists in many countries has doubled. However, the number of experienced ROMPs compared to the overall workforce is still small, especially in low and middle income countries. The increase in staff is matched by a similar increase in the number of treatment units over the years. Furthermore, the number of countries using complex techniques (IMRT, IGRT) or installing high end equipment (tomotherapy, robotic linear accelerators) is increasing. Overall, ROMPs still feel generally overworked and the professional recognition, while varying widely, appears to be improving only slightly. Radiation oncology medical physics practice has not changed significantly over the last 6 years in the Asia Pacific Region even if the number of physicists and the number and complexity of treatment techniques and technologies have increased dramatically.


Assuntos
Pessoal de Saúde/estatística & dados numéricos , Medicina Nuclear/estatística & dados numéricos , Radioterapia (Especialidade)/estatística & dados numéricos , Ásia , Humanos , Inquéritos e Questionários , Carga de Trabalho
6.
Med Phys ; 42(5): 2550-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25979047

RESUMO

PURPOSE: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. METHODS: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. RESULTS: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (± 1%), field size (± 1%), frame rate (± 3%), or beam energy (± 5%). The detector angular dependence was within ± 5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ± 3%. CONCLUSIONS: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.


Assuntos
Radiologia Intervencionista/instrumentação , Radiologia Intervencionista/métodos , Radiometria/instrumentação , Radiometria/métodos , Pele/efeitos da radiação , Calibragem , Relação Dose-Resposta à Radiação , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Modelos Lineares , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água
7.
Arch Dis Child Educ Pract Ed ; 100(3): 114-21, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25112285

RESUMO

Tuberous sclerosis complex is a complex childhood disorder characterised by the formation of hamartomas in multiple organs. Annual review of this disease is recommended to monitor the development of complications. We aim to provide a concise, evidence-based framework to assist clinicians during this annual review. We focus on the following areas: (A) what questions need to be asked during annual review, (B) which areas need emphasis on examination, (C) when is an investigation required and (D) referral to tertiary specialists and other members of the multidisciplinary team. It should also be noted that there are ongoing debates regarding screening intervals in certain areas. These include the frequency, modality of screening and degree of intervention for astrocytomas and renal angiomyolipomas. This review seeks to summarise the product of the ongoing debates, and provide evidence-based suggestions in light of the uncertainty.


Assuntos
Esclerose Tuberosa/complicações , Esclerose Tuberosa/diagnóstico , Criança , Humanos , Esclerose Tuberosa/genética
8.
Phys Med ; 30(8): 980-4, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25086486

RESUMO

Cobalt-60 (Co-60) is a relatively new source for the application of high-dose rate (HDR) brachytherapy. Radiation dose to the rectum is often a limiting factor in achieving the full prescribed dose to the target during brachytherapy of cervical cancer. The aim of this study was to measure radiation doses to the rectum in-vivo during HDR Co-60 brachytherapy. A total of eleven HDR brachytherapy treatments of cervical cancer were recruited in this study. A series of diodes incorporated in a rectal probe was inserted into the patient's rectum during each brachytherapy procedure. Real-time measured rectal doses were compared to calculated doses by the treatment planning system (TPS). The differences between calculated and measured dose ranged from 8.5% to 41.2%. This corresponds to absolute dose differences ranging from 0.3 Gy to 1.5 Gy. A linear relationship was observed between calculated and measured doses with linear regression R(2) value of 0.88, indicating close association between the measured and calculated doses. In general, absorbed doses for the rectum as calculated by TPS were observed to be higher than the doses measured using the diode probe. In-vivo dosimetry is an important quality assurance method for HDR brachytherapy of cervical cancer. It provides information that can contribute to the reduction of errors and discrepancies in dose delivery. Our study has shown that in-vivo dosimetry is feasible and can be performed to estimate the dose to the rectum during HDR brachytherapy using Co-60.


Assuntos
Braquiterapia/métodos , Radioisótopos de Cobalto/uso terapêutico , Reto/efeitos da radiação , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/efeitos adversos , Feminino , Humanos , Doses de Radiação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Software
9.
Indian J Otolaryngol Head Neck Surg ; 66(Suppl 1): 169-72, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24533378

RESUMO

The objective of this study is to assess high frequency hearing (above 8 kHz) loss among prolonged mobile phone users is a tertiary Referral Center. Prospective single blinded study. This is the first study that used high-frequency audiometry. The wide usage of mobile phone is so profound that we were unable to find enough non-users as a control group. Therefore we compared the non-dominant ear to the dominant ear using audiometric measurements. The study was a blinded study wherein the audiologist did not know which was the dominant ear. A total of 100 subjects were studied. Of the subjects studied 53% were males and 47% females. Mean age was 27. The left ear was dominant in 63%, 22% were dominant in the right ear and 15% did not have a preference. This study showed that there is significant loss in the dominant ear compared to the non-dominant ear (P < 0.05). Chronic usage mobile phone revealed high frequency hearing loss in the dominant ear (mobile phone used) compared to the non dominant ear.

10.
Am J Hosp Palliat Care ; 31(3): 281-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23650644

RESUMO

UNLABELLED: REASON FOR THE STUDY: Studies on methylphenidate for cancer-related fatigue showed conflicting results. This prospective study aims to determine whether methylphenidate is useful for relieving fatigue in Chinese patients with cancer. Chinese Version of Brief Fatigue Inventory (BFI-C) was administered on days 1, 8, and 29. Methylphenidate dose on day 1 was 5 mg daily then adjusted after day 8 according to response and side effects tolerance. MAIN FINDINGS: Only 48% of the 25 recruited patients were on methylphenidate by day 29. Overall, no significant improvement in fatigue level was observed after methylphenidate, though benefits were shown in subgroups with age ≤ 65 and higher baseline BFI-C values. PRINCIPAL CONCLUSIONS: Methylphenidate may be useful for management of cancer-related fatigue in selected Chinese patients.


Assuntos
Estimulantes do Sistema Nervoso Central/uso terapêutico , Fadiga/tratamento farmacológico , Metilfenidato/uso terapêutico , Neoplasias/complicações , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fadiga/diagnóstico , Fadiga/etiologia , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Paliativos/métodos , Índice de Gravidade de Doença , Resultado do Tratamento
11.
Clin Radiol ; 69(1): 63-71, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24156797

RESUMO

AIM: To investigate the capability and diagnostic accuracy of diffusion-weighted imaging (DWI) in differentiating benign from malignant breast lesions using 3 T magnetic resonance imaging (MRI). MATERIALS AND METHODS: Women with suspicious or indeterminate breast lesions detected at MRI, mammogram and/or ultrasound were recruited for dynamic contrast-enhanced (DCE)-MRI and DWI prior to their biopsy. Image fusion of DCE-MRI with apparent diffusion coefficient (ADC) map was utilized to select the region of interest (ROI) for ADC calculation in the area that showed the most avid enhancement. DWI was performed using two sets of b-values at 500 and 1000 s/mm(2), respectively. RESULTS: Fifty women were recruited and the final analysis comprised 44 breast lesions, 31 of which were malignant and 13 were benign. Significant results were obtained between ADC values of benign and malignant lesions (p < 0.001). The cut-off ADC values for benign and malignant lesions were 1.21 × 10(-3) mm(2)/s for b = 500 s/mm(2) and 1.22 × 10(-3) mm(2)/s for b = 1000 s/mm(2), respectively. The sensitivity of DCE-MRI alone was 100% with a specificity of 66.7%. When DCE-MRI was combined with b = 1000 s/mm(2), the specificity rose to 100%, while only mildly affecting sensitivity (90.6%). No significant correlation was found between ADC values and prognostic factors, such as lymph node metastasis, tumour size, oestrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) status, and tumour grades. CONCLUSION: The present study provides consistent evidence to support DWI as a diagnostic tool for breast lesion characterization. A combination of DCE-MRI with DWI is suggested to improve the sensitivity and specificity of lesion characterization.


Assuntos
Neoplasias da Mama/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Gadolínio DTPA , Humanos , Metástase Linfática , Mamografia , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária
12.
J Appl Clin Med Phys ; 14(4): 4182, 2013 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-23835383

RESUMO

Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.


Assuntos
Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/normas , Filme para Raios X , Calibragem , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Controle de Qualidade , Radiometria/instrumentação , Radiometria/normas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
13.
Clin Radiol ; 68(5): e225-36, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23465326

RESUMO

The aim of this article is to review the major limitations in current mammography and to describe how these may be addressed by digital breast tomosynthesis (DBT). DBT is a novel imaging technology in which an x-ray fan beam sweeps in an arc across the breast, producing tomographic images and enabling the production of volumetric, three-dimensional (3D) data. It can reduce tissue overlap encountered in conventional two-dimensional (2D) mammography, and thus has the potential to improve detection of breast cancer, reduce the suspicious presentations of normal tissues, and facilitate accurate differentiation of lesion types. This paper reviews the latest studies of this new technology. Issues including diagnostic efficacy, reading time, radiation dose, and level of compression; cost and new innovations are considered.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento Tridimensional/tendências , Mamografia/métodos , Mamografia/tendências , Intensificação de Imagem Radiográfica/métodos , Diagnóstico Diferencial , Feminino , Previsões , Humanos , Imageamento Tridimensional/economia , Mamografia/economia , Doses de Radiação , Intensificação de Imagem Radiográfica/economia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
14.
Br J Radiol ; 85(1013): 495-510, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22253353

RESUMO

Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. With high-quality coronary CT imaging increasingly being performed, patients can benefit from an imaging modality that provides a rapid and accurate diagnosis while avoiding an invasive procedure. Despite the tremendous contributions of coronary CT angiography to cardiac imaging, study results reported in the literature should be interpreted with caution as there are some limitations existing within the study design or related to patient risk factors. In addition, some attention must be given to the potential health risks associated with the ionising radiation received during cardiac CT examinations. Radiation dose associated with coronary CT angiography has raised serious concerns in the literature, as the risk of developing malignancy is not negligible. Various dose-saving strategies have been implemented, with some of the strategies resulting in significant dose reduction. The aim of this review is to present an overview of the role of coronary CT angiography on cardiac imaging, with focus on coronary artery disease in terms of the diagnostic and prognostic value of coronary CT angiography. Various approaches for dose reduction commonly recommended in the literature are discussed. Limitations of coronary CT angiography are identified. Finally, future directions and challenges with the use of coronary CT angiography are highlighted.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/instrumentação , Humanos , Tomografia Computadorizada Multidetectores/efeitos adversos , Tomografia Computadorizada Multidetectores/instrumentação , Imagem de Perfusão do Miocárdio , Revascularização Miocárdica , Prognóstico , Doses de Radiação , Risco , Stents
15.
Eur J Med Res ; 16(11): 501-6, 2011 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-22027644

RESUMO

Notch signaling is an evolutionarily conserved mechanism that enables adjacent cells to adopt different fates. Ghost cells (GCs) are anucleate cells with homogeneous pale eosinophilic cytoplasm and very pale to clear central areas (previous nucleus sites). Although GCs are present in a variety of odontogenic lesions notably the calcifying cystic odontogenic tumor (CCOT), their nature and process of formation remains elusive. The aim of this study was to investigate the role of Notch signaling in the cell fate specification of GCs in CCOT. Immunohistochemical staining for four Notch receptors (Notch1, Notch2, Notch3 and Notch4) and three ligands (Jagged1, Jagged2 and Delta1) was performed on archival tissues of five CCOT cases. Level of positivity was quantified as negative (0), mild (+), moderate (2+) and strong (3+). Results revealed that GCs demonstrated overexpression for Notch1 and Jagged1 suggesting that Notch1-Jagged1 signaling might serve as the main transduction mechanism in cell fate decision for GCs in CCOT. Protein localizations were largely membranous and/or cytoplasmic. Mineralized GCs also stained positive implicating that the calcification process might be associated with upregulation of these molecules. The other Notch receptors and ligands were weak to absent in GCs and tumoral epithelium. Stromal endothelium and fibroblasts were stained variably positive.


Assuntos
Linhagem da Célula , Cisto Odontogênico Calcificante/metabolismo , Cisto Odontogênico Calcificante/patologia , Tumores Odontogênicos/metabolismo , Tumores Odontogênicos/patologia , Receptores Notch/metabolismo , Transdução de Sinais , Adolescente , Adulto , Feminino , Humanos , Imuno-Histoquímica , Ligantes , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Eur J Med Res ; 16(7): 331-4, 2011 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-21813375

RESUMO

Wegener's granulomatosis is a rare multi-system disease characterized by the classic triad of necrotizing granulomas affecting the upper and lower respiratory tracts, disseminated vasculitis and glomerulonephritis. Oral lesions as a presenting feature are only encountered in 2% of these cases. Hyperplastic gingival lesions or strawberry gingivitis, is a characteristic sign of Wegener's granulomatosis. The latter consists of reddish-purple exophytic gingival swellings with petechial haemorrhages thus resembling strawberries. Recognition of this feature is of utmost importance for timely diagnosis and definitive management of this potentially fatal disease. A case of strawberry gingivitis as the first presenting sign of Wegener's granulomatosis affecting a 50-year-old Malay male is reported here. The differential diagnosis of red lesions that may present in the gingiva is discussed.


Assuntos
Gengivite/etiologia , Granulomatose com Poliangiite/diagnóstico , Diagnóstico Diferencial , Granulomatose com Poliangiite/complicações , Granulomatose com Poliangiite/tratamento farmacológico , Granulomatose com Poliangiite/patologia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Clin J Am Soc Nephrol ; 6(8): 1926-33, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21737855

RESUMO

BACKGROUND AND OBJECTIVES: Left ventricular hypertrophy (LVH) is an independent risk factor and an intermediate end point of dialysis-associated cardiovascular comorbidity. We utilized a global pediatric registry to assess the prevalence, incidence, and predictors of LVH as well as its evolution in the longitudinal follow-up in dialyzed children. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Cross-sectional echocardiographic, clinical, and biochemical data were evaluated in 507 children on peritoneal dialysis (PD), and longitudinal data were evaluated in 128 patients. The 95(th) percentile of LV mass index relative to height age was used to define LVH. RESULTS: The overall LVH prevalence was 48.1%. In the prospective analysis, the incidence of LVH developing de novo in patients with normal baseline LV mass was 29%, and the incidence of regression from LVH to normal LV mass 40% per year on PD. Transformation to and regression from concentric LV geometry occurred in 36% and 28% of the patients, respectively. Hypertension, high body mass index, use of continuous ambulatory peritoneal dialysis, renal disease other than hypo/dysplasia, and hyperparathyroidism were identified as independent predictors of LVH. The use of renin-angiotensin system (RAS) antagonists and high total fluid output (sum of urine and ultrafiltration) were protective from concentric geometry. The risk of LVH at 1 year was increased by higher systolic BP standard deviation score and reduced in children with renal hypo/dysplasia. CONCLUSIONS: Using height-adjusted left ventricular mass index reference data, LVH is highly prevalent but less common than previously diagnosed in children on PD. Renal hypo/dysplasia is protective from LVH, likely because of lower BP and polyuria. Hypertension, fluid overload, and hyperparathyroidism are modifiable determinants of LVH.


Assuntos
Hipertrofia Ventricular Esquerda/epidemiologia , Nefropatias/terapia , Diálise Peritoneal/efeitos adversos , Adolescente , Ásia/epidemiologia , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Doença Crônica , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Incidência , Lactente , Nefropatias/epidemiologia , Modelos Logísticos , Masculino , América do Norte/epidemiologia , Razão de Chances , Prevalência , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , América do Sul/epidemiologia , Fatores de Tempo , Ultrassonografia , Adulto Jovem
18.
Colorectal Dis ; 13(6): 627-31, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20163425

RESUMO

AIM: Total mesorectal excision (TME) is currently the gold standard for resection of mid or low rectal cancer and is associated with a low local recurrence rate. However, few studies have reported the long-term oncological outcome following use of a laparoscopic approach. The aim of this study was to evaluate the long-term oncological outcome after laparoscopic sphincter-preserving TME with a median follow up of about 4 years. METHOD: Patients with mid or low rectal cancer who underwent laparoscopic sphincter-preserving TME with curative intent between March 1999 and March 2009 were prospectively recruited for analysis. RESULTS: During the 10-year study period, 177 patients underwent laparoscopic sphincter-preserving TME with curative intent for rectal cancer. Conversion was required in two (1%) patients. There was no operative mortality. At a median follow-up period of 49 months, local recurrence had occurred in nine (5.1%) patients. The overall metastatic recurrence rate after curative resection was 22%. The overall 5-year survival and 5-year disease-free survival in the present study were 74% and 71%, respectively. CONCLUSION: The results of this study show that laparoscopic sphincter-preserving TME is safe with long-term oncological outcomes comparable to those of open surgery.


Assuntos
Laparoscopia , Recidiva Local de Neoplasia , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Canal Anal/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Intervalo Livre de Doença , Incontinência Fecal/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Laparoscopia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Disfunções Sexuais Fisiológicas/etiologia , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
19.
Eur J Med Res ; 15(10): 456-60, 2010 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-21156405

RESUMO

BACKGROUND: notch receptors are critical determinants of cell fate in a variety of organisms. Notch signaling is involved in the chondrogenic specification of neural crest cells. Aberrant Notch activity has been implicated in numerous human diseases including cancers; however its role in chondrogenic tumors has not been clarified. METHOD: tissue samples from a case of primary chondrosarcoma of the maxilla and its recurrent tumor were examined immunohistochemically for Notch1-4 and their ligands (Jagged1, Jagged2 and Delta1) expression. RESULTS: both primary and recurrent tumors were histopathologically diagnosed as conventional hyaline chondrosarcoma (WHO Grade I). Hypercellular tumor areas strongly expressed Notch3 and Jagged1 in spindle and pleomorphic cells suggesting up-regulation of these protein molecules at sites of tumor proliferation. Expression patterns were distinct with some overlap. Differentiated malignant and atypical chondrocytes demonstrated variable expression levels of Jagged1, and weak to absent staining for Notch1, 4 and Delta1. Protein immunolocalization was largely membranous and cytoplasmic, sometimes outlining the lacunae of malignant chondrocytes. Hyaline cartilage demonstrated a diffuse or granular precipitation of Jagged1 suggesting presence of soluble Jagged1 activity at sites of abnormal chondrogenesis. No immunoreactivity for the other Notch members was observed. Calcified cartilage was consistently Notch-negative indicating down-regulation of Notch with cartilage maturation. Stromal components namely endothelial cells and fibroblasts variably expressed Notch1, 3 and Jagged1 but were mildly or non-reactive for the other members. CONCLUSIONS: Results indicate that Notch signaling pathway may participate in cellular differentiation and proliferation in chondrosarcoma. Findings implicate Notch3 and Jagged1 as key molecules that influence the differentiation and maturation of cells of chondrogenic lineage.


Assuntos
Condrossarcoma/metabolismo , Receptores Notch/genética , Cartilagem/metabolismo , Cartilagem/patologia , Condrossarcoma/patologia , Feminino , Humanos , Imuno-Histoquímica , Neoplasias Maxilares/metabolismo , Neoplasias Maxilares/patologia , Pessoa de Meia-Idade , Neoplasias Nasofaríngeas/metabolismo , Neoplasias Nasofaríngeas/radioterapia , Recidiva Local de Neoplasia/metabolismo , Proteínas Proto-Oncogênicas/metabolismo , Receptor Notch1/metabolismo , Receptor Notch2/metabolismo , Receptor Notch3 , Receptor Notch4 , Receptores Notch/metabolismo
20.
Australas Phys Eng Sci Med ; 33(4): 329-34, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20938762

RESUMO

The performance of a digital mammography system (Siemens Mammomat Novation) using different target/filter combinations and tube voltage has been assessed. The objective of this study is to optimize beam quality selection based on contrast-to-noise ratio (CNR) and mean glandular dose (MGD). Three composition of breast were studied with composition of glandular/adipose of 30/70, 50/50, and 70/30. CNR was measured using 2, 4 and 6 cm-thick simulated breast phantoms with an aluminium sheet of 0.1 mm thickness placed on top of the phantom. Three target/filter combinations, namely molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh) and tungsten/rhodium (W/Rh) with various tube voltage and mAs were tested. MGD was measured for each exposure. For 50/50 breast composition, Mo/Rh combination with tube voltage 26 kVp is optimal for 2 cm-thick breast. W/Rh combination with tube voltage 27 and 28 kVp are optimal for 4 and 6 cm-thick breast, respectively. For both 30/70 and 70/30 breast composition, W/Rh combination is optimal with tube voltage 25, 26 and 27 kVp, respectively. From our study it was shown that there are potential of dose reduction up to 11% for a set CNR of 3.0 by using beam quality other than that are determined by AEC selection. Under the constraint of lowest MGD, for a particular breast composition, calcification detection is optimized by using a softer X-ray beam for thin breast and harder X-ray beam for thick breast. These experimental results also indicate that for breast with high fibroglandular tissues (70/30), the use of higher beam quality does not always increase calcification detection due to additional structured noise caused by the fibroglandular tissues itself.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Mama/anatomia & histologia , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS