Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
2.
Phys Eng Sci Med ; 47(1): 61-71, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37843766

RESUMO

Many studies have investigated the dielectric properties of human and animal tissues, particularly to differentiate between normal cells and tumors. However, these studies are invasive as tissue samples have to be excised to measure the properties. This study aims to investigate the dielectric properties of urine in relation to bladder cancer, which is safe and non-invasive to patients. 30 healthy subjects and 30 bladder cancer patients were recruited. Their urine samples were subjected to urinalysis and cytology assessment. A vector network analyzer was used to measure the dielectric constant (Ɛ') and loss factor (Ɛ″) at microwave frequencies of between 0.2 and 50 GHz at 25 °C, 30 °C and 37 °C. Significant differences in Ɛ' and Ɛ″ were observed between healthy subjects and patients, especially at frequencies of between 25 and 40 GHz at 25 °C. Bladder cancer patients had significant lower Ɛ' and higher Ɛ″ compared with healthy subjects. The Ɛ' was negatively correlated with urinary exfoliated urothelial cell number, and Ɛ″ was positively correlated. The study achieved a receiver operating characteristic area under curve (ROC-AUC) score of 0.69099 and an optimum accuracy of 75% with a sensitivity of 80% and a specificity of 70%. The number of exfoliated urothelial cell had significant effect on the dielectric properties, especially in bladder cancer patients. Urinary dielectric properties could potentially be used as a tool to detect bladder cancer.


Assuntos
Neoplasias da Bexiga Urinária , Humanos , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/urina , Curva ROC , Urinálise , Células Epiteliais/patologia , Citodiagnóstico
3.
J Plast Reconstr Aesthet Surg ; 83: 380-395, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302244

RESUMO

BACKGROUND: Breast ptosis is characterized by the inferolateral descent of the glandular area and nipple-areola complex. A high degree of ptosis may negatively impact a woman's attractiveness and self-confidence. There are various classifications and measurement techniques for breast ptosis used as references in the medical and garment industry. A practical and comprehensive classification will provide accurate standardized definitions of the degrees of ptosis to facilitate the development of corrective surgeries and well-fitting undergarments for women in need. METHODS: A systematic review on the classification and assessment techniques to measure breast ptosis was carried out based on the Preferred Reporting Items for Systemic Reviews and Meta-Analyses (PRISMA) guidelines. The risk of bias was assessed using the modified Newcastle-Ottawa scale for observational studies, whereas the Revised Cochrane risk-of-bias tool for randomized trials (RoB2) was used to evaluate randomized studies. RESULTS: Of 2550 articles identified in the literature search, 16 observational and 2 randomized studies describing the classification and assessment techniques of breast ptosis were included in the review. A total of 2033 subjects were involved. Half of the total observational studies had a Newcastle-Ottawa scale score of 5 and above. In addition, all randomized trials recorded a low overall bias. CONCLUSION: A total of 7 classifications and 4 measurement techniques for breast ptosis were identified. However, most studies did not demonstrate a clear derivation of sample size beside lacking robust statistical analysis. Hence, further studies that apply the latest technology to combine the strength of previous assessment techniques are needed to develop better classification system that is applicable to all affected women.


Assuntos
Mama , Feminino , Humanos , Mamilos , Mama/patologia
4.
Phys Eng Sci Med ; 46(3): 1175-1185, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37253939

RESUMO

TMP is gradually becoming a fundamental element for quality assurance and control in ionizing and non-ionizing radiation imaging modalities as well as in the development of different techniques. This study aimed to evaluate and obtain polyvinyl chloride tissue mimicking material for dual-modality breast phantoms in mammography and ultrasound. Breast tissue equivalence was evaluated based on X-ray attenuation properties, speed of sound, attenuation, and acoustic impedance. There are six samples of PVC-plasticizer material with variations of PVC concentration and additives. The evaluation of X-ray attenuation was carried out using mammography from 23 to 35 kV, while the acoustic properties were assessed with mode A ultrasound and a transducer frequency of 5 MHz. A breast phantom was created from TMP material with tissue equivalence and was then evaluated using mammography as well as ultrasound to analyze its image quality. The results showed that samples A (PVC 5%, DOP 95%), B (PVC 7%, DOP 93%), C (PVC 10%, DOP 90%), E (PVC 7%, DOP 90%, graphite 3%), and F (PVC 7%, DOP 90%, silicone oil 3%) have the closest equivalent to the ACR breast phantom material with a different range of 0.01-1.39 in the 23-35 kV range. Based on the evaluation of the acoustic properties of ultrasound, A had high similarity to fat tissue with a difference of 0.03 (dB cm- 1 MHz- 1) and 0.07 (106 kg m- 2 s- 1), while B was close to the glandular tissue with a difference of 9.2 m s- 1. Multilayer breast phantom images' results showed gray levels in mammography and ultrasound modalities. Therefore, this study succeeded in establishing TMP material for mammography and ultrasound. It can also be used for simple quality assurance and control programs.


Assuntos
Mamografia , Cloreto de Polivinila , Ultrassonografia , Imagens de Fantasmas , Tecido Adiposo
5.
Comput Methods Programs Biomed ; 236: 107544, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37148668

RESUMO

OBJECTIVES: To elucidate a novel radiogenomics approach using three-dimensional (3D) topologically invariant Betti numbers (BNs) for topological characterization of epidermal growth factor receptor (EGFR) Del19 and L858R mutation subtypes. METHODS: In total, 154 patients (wild-type EGFR, 72 patients; Del19 mutation, 45 patients; and L858R mutation, 37 patients) were retrospectively enrolled and randomly divided into 92 training and 62 test cases. Two support vector machine (SVM) models to distinguish between wild-type and mutant EGFR (mutation [M] classification) as well as between the Del19 and L858R subtypes (subtype [S] classification) were trained using 3DBN features. These features were computed from 3DBN maps by using histogram and texture analyses. The 3DBN maps were generated using computed tomography (CT) images based on the Cech complex constructed on sets of points in the images. These points were defined by coordinates of voxels with CT values higher than several threshold values. The M classification model was built using image features and demographic parameters of sex and smoking status. The SVM models were evaluated by determining their classification accuracies. The feasibility of the 3DBN model was compared with those of conventional radiomic models based on pseudo-3D BN (p3DBN), two-dimensional BN (2DBN), and CT and wavelet-decomposition (WD) images. The validation of the model was repeated with 100 times random sampling. RESULTS: The mean test accuracies for M classification with 3DBN, p3DBN, 2DBN, CT, and WD images were 0.810, 0.733, 0.838, 0.782, and 0.799, respectively. The mean test accuracies for S classification with 3DBN, p3DBN, 2DBN, CT, and WD images were 0.773, 0.694, 0.657, 0.581, and 0.696, respectively. CONCLUSION: 3DBN features, which showed a radiogenomic association with the characteristics of the EGFR Del19/L858R mutation subtypes, yielded higher accuracy for subtype classifications in comparison with conventional features.


Assuntos
Neoplasias Pulmonares , Humanos , Estudos Retrospectivos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Mutação , Tomografia Computadorizada por Raios X/métodos , Receptores ErbB/genética
6.
Med Phys ; 49(12): 7742-7753, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36098271

RESUMO

PURPOSE: Monte Carlo (MC) simulation is an important technique that can help design advanced and challenging experimental setups. GATE (Geant4 application for tomographic emission) is a useful simulation toolkit for applications in nuclear medicine. Transarterial radioembolization is a treatment for liver cancer, where microspheres embedded with yttrium-90 (90 Y) are administered intra-arterially to the tumor. Personalized dosimetry for this treatment may provide higher dosimetry accuracy compared to the conventional partition model (PM) calculation. However, incorporation of three-dimensional tomographic input data into MC simulation is an intricate process. In this article, 3D Slicer, free and open-source software, was utilized for the incorporation of patient tomographic images into GATE to demonstrate the feasibility of personalized dosimetry in hepatic radioembolization with 90 Y. METHODS: In this article, the steps involved in importing, segmenting, and registering tomographic images using 3D Slicer were thoroughly described, before importing them into GATE for MC simulation. The absorbed doses estimated using GATE were then compared with that of PM. SlicerRT, a 3D Slicer extension, was then used to visualize the isodose from the MC simulation. RESULTS: A workflow diagram consisting of all the steps taken in the utilization of 3D Slicer for personalized dosimetry in 90 Y radioembolization has been presented in this article. In comparison to the MC simulation, the absorbed doses to the tumor and normal liver were overestimated by PM by 105.55% and 20.23%, respectively, whereas for lungs, the absorbed dose estimated by PM was underestimated by 25.32%. These values were supported by the isodose distribution obtained via SlicerRT, suggesting the presence of beta particles outside the volumes of interest. These findings demonstrate the importance of personalized dosimetry for a more accurate absorbed dose estimation compared to PM. CONCLUSION: The methodology provided in this study can assist users (especially students or researchers who are new to MC simulation) in navigating intricate steps required in the importation of tomographic data for MC simulation. These steps can also be utilized for other radiation therapy related applications, not necessarily limited to internal dosimetry.


Assuntos
Neoplasias Hepáticas , Radioisótopos de Ítrio , Humanos , Método de Monte Carlo , Radioisótopos de Ítrio/uso terapêutico , Simulação por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Radiometria/métodos
7.
Acad Radiol ; 29(4): e39-e48, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33992535

RESUMO

RATIONALE AND OBJECTIVES: Molecular studies have shown the changes in bone marrow fat in relation to altered hematopoiesis. This study aims to investigate the changes in the bone marrow fat in patients affected by ß-thalassemia by using chemical shift-encoded (CSE)-MRI. MATERIALS AND METHODS: Twenty-three subjects, comprising of six healthy (17-31 years old) and 17 ß-thalassemia subjects (19-39 years old), were scanned using a multiecho fast low angle shot sequence (0.94 × 0.94 × 3.00 mm3) and a stimulated echo acquisition mode sequence using 3T MRI. Bone marrow proton density fat fraction (PDFF) was quantified in the left femur of each subject. Regression and Bland-Altman analysis were used to analyze agreement between CSE-MRI and 1H-MRS. PDFF distribution was analyzed using Hartigan's dip test and the computed Wasserstein distances. Jonckheere-Terpstra trend analysis was performed to evaluate the effect of disease severity on PDFF distribution. RESULTS: An excellent agreement was found between PDFF measured using CSE-MRI with 1H-MRS (R2 = 0.91; bias =-1.41%). Healthy subjects showed left-skewed or bimodal PDFF distribution while ß-thalassemia subjects showed bimodal, normal or right-skewed distribution. Jonckheere-Terpstra test shows that PDFF distribution was increasingly different from the norm as disease severity increased (TJT = 166.0, z = 3.806, p < 0.05). Increase in variability of PDFF distribution within each subject group was also seen with increasing disease severity (TJT = 169.0, z = 3.971, p < 0.05). CONCLUSION: CSE-MRI is a promising tool to demonstrate spatial changes and variability in marrow fat distribution, resulting from ineffective erythropoiesis.


Assuntos
Medula Óssea , Talassemia beta , Tecido Adiposo/diagnóstico por imagem , Adolescente , Adulto , Medula Óssea/diagnóstico por imagem , Humanos , Fígado , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Água , Adulto Jovem , Talassemia beta/diagnóstico por imagem
8.
Acad Radiol ; 29 Suppl 1: S89-S106, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34481705

RESUMO

OBJECTIVE: Magnetic resonance imaging (MRI) is the most sensitive imaging modality in detecting breast cancer. The purpose of this systematic review is to investigate the role of human extracted MRI phenotypes in classifying molecular subtypes of breast cancer. METHODS: We performed a literature search of published articles on the application of MRI phenotypic features in invasive breast cancer molecular subtype classifications by radiologists' interpretation on Medline Complete, Pubmed, and Google scholar from 1st January 2000 to 31st March 2021. Of the 1453 literature identified, 42 fulfilled the inclusion criteria. RESULTS: All studies were case-controlled, retrospective study and research-based. The majority of the studies assessed the MRI features using American College of Radiology- Breast Imaging Reporting and Data System (ACR-BIRADS) classification and using dynamic contrast-enhanced (DCE) kinetic features, Apparent Diffusion Coefficient (ADC) values, and T2 sequence. Most studies divided invasive breast cancer into 4 main subtypes, luminal A, luminal B, HER2, and triple-negative (TN) cancers, and used 2 readers. We present a summary of the radiologists' extracted breast MRI phenotypical features and their correlating breast cancer subtypes classifications. The characteristic features are morphology, enhancement kinetics, and T2 signal intensity. We found that the TN subtype has the most distinctive MRI features compared to the other subtypes and luminal A and B have many similar features. CONCLUSION: The MRI features which are predictive of each subtype are the morphology, internal enhancement features, and T2 signal intensity, predominantly between TN and the rest. Radiologists' visual interpretation of some of MRI features may offer insight into the respective invasive breast cancer molecular subtype. However, current evidence are still limited to "suggestive" features instead of a diagnostic standard.  Further research is recommended to explore this potential application, for example, by augmentation of radiologists' visual interpretation by artificial intelligence.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Fenótipo , Estudos Retrospectivos
9.
Med Dosim ; 46(3): 310-317, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33838998

RESUMO

Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
10.
J Med Imaging Radiat Oncol ; 65(4): 464-470, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33606359

RESUMO

More than half of the world's population live in Asia-Pacific. This region is culturally diverse, with significant disparities in terms of socio-economic status, provision of health care and access to advanced technology. The medical use of ionising radiation is increasing worldwide and similarly within the Asia-Pacific region. In this paper, we highlight the current status in usage of ionising radiation in medicine in the region, and review the legal framework, implementation and activities in radiation protection. Asia-Pacific countries are active in strengthening radiation protection by promoting education and training. Various projects and activities initiated by international organisations such as the IAEA, WHO and ICRP have provided stimulation in the region, but more work is needed to continue to improve protection practices.


Assuntos
Radioterapia (Especialidade) , Proteção Radiológica , Ásia , Humanos
11.
Med Biol Eng Comput ; 59(2): 355-367, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33447988

RESUMO

This study objectively evaluates the similarity between standard full-field digital mammograms and two-dimensional synthesized digital mammograms (2DSM) in a cohort of women undergoing mammography. Under an institutional review board-approved data collection protocol, we retrospectively analyzed 407 women with digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) examinations performed from September 1, 2014, through February 29, 2016. Both FFDM and 2DSM images were used for the analysis, and 3216 available craniocaudal (CC) and mediolateral oblique (MLO) view mammograms altogether were included in the dataset. We analyzed the mammograms using a fully automated algorithm that computes 152 structural similarity, texture, and mammographic density-based features. We trained and developed two different global mammographic image feature analysis-based breast cancer detection schemes for 2DSM and FFDM images, respectively. The highest structural similarity features were obtained on the coarse Weber Local Descriptor differential excitation texture feature component computed on the CC view images (0.8770) and MLO view images (0.8889). Although the coarse structures are similar, the global mammographic image feature-based cancer detection scheme trained on 2DSM images outperformed the corresponding scheme trained on FFDM images, with area under a receiver operating characteristic curve (AUC) = 0.878 ± 0.034 and 0.756 ± 0.052, respectively. Consequently, further investigation is required to examine whether DBT can replace FFDM as a standalone technique, especially for the development of automated objective-based methods.


Assuntos
Neoplasias da Mama , Mamografia , Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Curva ROC , Estudos Retrospectivos
12.
PLoS One ; 16(1): e0244354, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33428651

RESUMO

OBJECTIVES: To propose a novel robust radiogenomics approach to the identification of epidermal growth factor receptor (EGFR) mutations among patients with non-small cell lung cancer (NSCLC) using Betti numbers (BNs). MATERIALS AND METHODS: Contrast enhanced computed tomography (CT) images of 194 multi-racial NSCLC patients (79 EGFR mutants and 115 wildtypes) were collected from three different countries using 5 manufacturers' scanners with a variety of scanning parameters. Ninety-nine cases obtained from the University of Malaya Medical Centre (UMMC) in Malaysia were used for training and validation procedures. Forty-one cases collected from the Kyushu University Hospital (KUH) in Japan and fifty-four cases obtained from The Cancer Imaging Archive (TCIA) in America were used for a test procedure. Radiomic features were obtained from BN maps, which represent topologically invariant heterogeneous characteristics of lung cancer on CT images, by applying histogram- and texture-based feature computations. A BN-based signature was determined using support vector machine (SVM) models with the best combination of features that maximized a robustness index (RI) which defined a higher total area under receiver operating characteristics curves (AUCs) and lower difference of AUCs between the training and the validation. The SVM model was built using the signature and optimized in a five-fold cross validation. The BN-based model was compared to conventional original image (OI)- and wavelet-decomposition (WD)-based models with respect to the RI between the validation and the test. RESULTS: The BN-based model showed a higher RI of 1.51 compared with the models based on the OI (RI: 1.33) and the WD (RI: 1.29). CONCLUSION: The proposed model showed higher robustness than the conventional models in the identification of EGFR mutations among NSCLC patients. The results suggested the robustness of the BN-based approach against variations in image scanner/scanning parameters.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/genética , Receptores ErbB/genética , Feminino , Humanos , Japão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Malásia , Masculino , Pessoa de Meia-Idade , Mutação , Curva ROC , Máquina de Vetores de Suporte , Tomografia Computadorizada por Raios X , Estados Unidos
13.
J Magn Reson Imaging ; 53(1): 190-198, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33237616

RESUMO

BACKGROUND: ß-thalassemia is a genetic disease that causes abnormal production of red blood cells (ineffective erythropoiesis, IE). IE is a condition known to change bone marrow composition. PURPOSE: To evaluate the effect of IE on the marrow fat content and fat unsaturation levels in the proximal femur using 1 H-MRS. STUDY TYPE: Prospective. SUBJECTS: Twenty-three subjects were included in this study, seven control and 16 ß-thalassemia subjects. FIELD STRENGTH/SEQUENCE: 3.0T; stimulated echo acquisition Mode (STEAM); magnetic resonance spectroscopy (MRS) sequence. ASSESSMENT: Multiecho MRS scans were performed in four regions of the proximal left femur of each subject, that is, diaphysis, femoral neck, femoral head, and greater trochanter. The examined regions were grouped into red (diaphysis and femoral neck) and yellow marrow regions (femoral head and greater trochanter). STATISTICAL TESTS: The Jonckheere-Terpstra test was used to evaluate the impact of increasing disease severity on bone marrow fat fraction (BMFF), marrow conversion index, and fat unsaturation index (UI). Pairwise comparison analysis was performed when a significant trend (P < 0.05) was found. K-means clustering analysis was used to examine the clusters observed when BMFF in the red and yellow regions were studied (diaphysis against greater trochanter). RESULTS: BMFF showed a significant decreasing trend with increasing disease severity in both red (TJT = 109.00, z = -4.414, P < 0.05) and yellow marrow regions (TJT = 108.00, z = -4.438, P < 0.05). The opposite trend was observed in UI in both bone marrow regions (red marrow: TJT = 180.5, z = 3.515, P < 0.05; yellow marrow: TJT = 155.0, z = 2.282, P = 0.05). Three distinct forms of marrow adipogenesis were found when plotting BMFF diaphysis against BMFF greater trochanter: 1) normal (centroid: 80.4%, 66.6%), 2) partial disruption (centroid: 51.1%, 16.6%), and 3) total disruption (centroid: 2.6%, 1.6%). DATA CONCLUSION: ß-thalassemia is associated with decreased marrow fat, and increased marrow fat unsaturation level. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Medula Óssea , Talassemia beta , Tecido Adiposo/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Talassemia beta/diagnóstico por imagem
14.
Nephrology (Carlton) ; 26(1): 38-45, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33058334

RESUMO

AIM: Renal biopsy is the gold standard for the histological characterization of chronic kidney disease (CKD), of which renal fibrosis is a dominant component, affecting its stiffness. The aim of this study was to investigate the correlation between kidney stiffness obtained by shear wave elastography (SWE) and renal histological fibrosis. METHODS: Shear wave elastography assessments were performed in 75 CKD patients who underwent renal biopsy. The SWE-derived estimates of the tissue Young's modulus (YM), given as kilopascals (kPa), were measured. YM was correlated to patients' renal histological scores, broadly categorized into glomerular, tubulointerstitial and vascular scores. RESULTS: Young's modulus correlates significantly with tubulointerstitial score (ρ = 0.442, P < .001) and glomerular score (ρ = 0.375, P = .001). Patients with no glomerular sclerosis showed lower mean YM measurements compared to those with glomerular sclerosis. The mean YM increased as the percentage of interstitial fibrosis and tubular atrophy increased. The area under the receiver operating characteristic curve (ROC) for SWE in differentiating between mildly and moderately impaired kidneys was 0.702. CONCLUSION: Shear wave elastography accurately detects chronic renal damage resulting from glomerular sclerosis, interstitial fibrosis and tubular atrophy, using the optimal cut-off YM value of ≥5.81 kPa.


Assuntos
Biópsia/métodos , Técnicas de Imagem por Elasticidade/métodos , Rim , Insuficiência Renal Crônica/diagnóstico , Atrofia , Módulo de Elasticidade , Elasticidade/fisiologia , Feminino , Fibrose , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Ultrassonografia de Intervenção/métodos
15.
Diagnostics (Basel) ; 10(9)2020 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-32917029

RESUMO

In this study, we aimed to estimate the probability of cancer risk induced by CT pulmonary angiography (CTPA) examinations concerning effective body diameter. One hundred patients who underwent CTPA examinations were recruited as subjects from a single institution in Kuala Lumpur. Subjects were categorized based on their effective diameter size, where 19-25, 25-28, and >28 cm categorized as Groups 1, 2, and 3, respectively. The mean value of the body diameter of the subjects was 26.82 ± 3.12 cm, with no significant differences found between male and female subjects. The risk of cancer in breast, lung, and liver organs was 0.009%, 0.007%, and 0.005% respectively. The volume-weighted CT dose index (CTDIvol) was underestimated, whereas the size-specific dose estimates (SSDEs) provided a more accurate description of the radiation dose and the risk of cancer. CTPA examinations are considered safe but it is essential to implement a protocol optimized following the As Low as Reasonably Achievable (ALARA) principle.

16.
Breast J ; 26(11): 2208-2212, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32996224

RESUMO

Oncoplastic breast surgery (OBS) improves margin clearance and produces good esthetic outcome in breast cancer treatment. This study evaluates the complications and outcome of OBS in a multiracial patient cohort. Data of 421 patients between 2011 and 2018 were analyzed. The majority were Malays (41.8%), followed by Chinese (39.7%) and Indians (16.8%). Low local complications were noted, with no significant differences in disease-free survival (P = .927) and overall survival (P = .719) between low and high OBS levels. Shared decision-making in offering OBS for Asian women has potential to become a practical option in breast cancer treatment.


Assuntos
Neoplasias da Mama , Mamoplastia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mamoplastia/efeitos adversos , Mastectomia Segmentar , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Diagnostics (Basel) ; 10(8)2020 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-32823818

RESUMO

Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0-1 year), group 2 (1-5 years), group 3 (5-10 years) and group 4 (10-15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10-15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.

18.
Phys Med ; 67: 34-39, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31655398

RESUMO

PURPOSE: Intensity Modulated Radiotherapy (IMRT) has changed the practice of radiotherapy since its implementation in the 1990s. The purpose of this study is to review current practice of IMRT in Malaysia. METHODS: A survey on medical physics aspects of IMRT is conducted on radiotherapy departments across Malaysia to assess the usage, experience and QA in IMRT, which is done for the first time in this country. A set of questionnaires was designed and sent to the physicist in charge for their responses. The questionnaire consisted of four sections; (i) Experience and qualification of medical physicists, (ii) CT simulation techniques (iii) Treatment planning and treatment unit, (iv) IMRT process, delivery and QA procedure. RESULTS: A total of 26 responses were collected, representing 26 departments out of 33 radiotherapy departments in operation across Malaysia (79% response rate). Results showed that the medical physics aspects of IMRT practice in Malaysia are homogenous, with some variations in certain areas of practices. Thirteen centres (52%) performed measurement-based QA using 2D array detector and analysed using gamma index criteria of 3%, 3 mm with variation confidence range. In relation to the IMRT delivery, 44% of Malaysia's physicist takes more than 8 h to plan a head and neck case compared to the UK study possibly due to the lack of professional training. CONCLUSIONS: This survey provides a picture of medical physics aspects of IMRT in Malaysia where the results/data can be used by radiotherapy departments to benchmark their local policies and practice.


Assuntos
Física , Radioterapia de Intensidade Modulada , Competência Clínica/estatística & dados numéricos , Humanos , Malásia , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
19.
J Cancer ; 10(17): 4038-4044, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31417648

RESUMO

Background and purpose: Bladder cancer is the most common malignant tumour in the urinary system, with a high incidence and recurrence rate. While the incidence of bladder cancer has been rising in recent years, the prevalence of bladder carcinoma is showing an increasing tendency in the younger age group. There are several methods to detect bladder cancer, but different methods have varying degrees of accuracy which intrinsically depends on the method's sensitivity and specificity. Our aim was to comprehensively summarize the current detection methods for bladder cancer based on the available literature, and at the same time, to find the best combination of different effective methods which can produce a high degree of accuracy in detecting the presence of cancerous cells in the bladder. Materials and Methods: We used key word retrieval method for searching related references in English that had been indexed in PubMed and Medline. Results and Discussion: This paper discussed the different detection methods and their sensitivities/specificities as well as the advantages and disadvantages. We summarized the best identified cancer cell detection methods with higher sensitivity/specificity. Conclusion: The results of this review can positively help to identify accurate methods for detecting bladder cancer and highlight areas to be further improved for future research work.

20.
Quant Imaging Med Surg ; 9(4): 552-564, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31143647

RESUMO

BACKGROUND: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol. METHODS: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols. RESULTS: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05). CONCLUSIONS: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA