Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
J Clin Med ; 13(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38592259

RESUMO

Background: Minimally invasive mitral valve surgery (MIC-MVS) has been established as preferred treatment of mitral regurgitation (MR), but mitral transcatheter edge-to-edge valve repair (M-TEER) is routinely performed in patients at high surgical risk and is increasingly performed in intermediate risk patients. Methods: From 2010 to 2021, we performed 723 M-TEER and 123 isolated MIC-MVS procedures. We applied a sensitivity analysis by matching age, left ventricular ejection fraction (LVEF), EuroSCORE II and etiology of MR. Results: Baseline characteristics showed significant differences in the overall cohort (p < 0.01): age 78.3 years vs. 61.5 years, EuroSCORE II 5.5% vs. 1.3% and LVEF 48.4% vs. 60.4% in M-TEER vs. MIC-MVS patients. Grade of MR at discharge was moderate/severe in 24.5% (171/697) in M-TEER vs. 6.5% (8/123) in MIC-MVS (p < 0.01). One-year survival was 91.5% (552/723) in M-TEER vs. 97.6% (95/123) in MIC-MVS (p = 0.04). A matching with 49 pairs (n = 98) showed comparable survival during follow-up, but a numerically higher mean mitral valve gradient of 4.1 mmHg (95% CI: 3.6-4.6) vs. 3.4 mmHg (95% CI: 3.0-3.8) in M-TEER (p = 0.04). Conclusions: Patients undergoing M-TEER had lower one-year survival than MIC-MVS, but differences disappeared after matching. Reduction in MR was less effective in M-TEER patients and postprocedural mitral valve gradients were higher.

3.
Acta Physiol (Oxf) ; 240(5): e14140, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38546351

RESUMO

AIM: Inflammation and calcification are hallmarks in the development of aortic valve stenosis (AVS). Ceramides mediate inflammation and calcification in the vascular tissue. The highly abundant d18:1,16:0 ceramide (C16) has been linked to increased cardiovascular mortality and obesity. In this study, we investigate the role of ceramide synthase 5 (CerS5), a critical enzyme for C16 ceramide synthesis, in the development of AVS, particularly in conjunction with a high-fat/high-cholesterol diet (Western diet, WD). METHODS: We used wild-type (WT) and CerS5-/- mice on WD or normal chow in a wire injury model. We measured the peak velocity to determine AVS development and performed histological analysis of the aortic valve area, immune cell infiltration (CD68 staining), and calcification (von Kossa). In vitro experiments involved measuring the calcification of human aortic valvular interstitial cells (VICs) and evaluating cytokine release from THP-1 cells, a human leukemia monocytic-like cell line, following CerS5 knockdown. RESULTS: CerS5-/- mice showed a reduced peak velocity compared to WT only in the experiment with WD. Likewise, we observed reduced immune cell infiltration and calcification in the aortic valve of CerS5-/- mice, but only on WD. In vitro, calcification was reduced after knockdown of CerS5 in VICs, while THP-1 cells exhibited a decreased inflammatory response following CerS5 knockdown. CONCLUSION: We conclude that CerS5 is an important mediator for the development of AVS in mice on WD and regulates critical pathophysiological hallmarks of AVS formation. CerS5 is therefore an interesting target for pharmacological therapy and merits further investigation.

4.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38458388

RESUMO

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Idoso de 80 Anos ou mais , Sistema de Registros , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Meios de Contraste/administração & dosagem , Seguimentos
5.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38385922

RESUMO

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Sistema de Registros
6.
JACC Cardiovasc Imaging ; 17(1): 79-95, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37731368

RESUMO

Tricuspid regurgitation (TR) is a highly prevalent and heterogeneous valvular disease, independently associated with excess mortality and high morbidity in all clinical contexts. TR is profoundly undertreated by surgery and is often discovered late in patients presenting with right-sided heart failure. To address the issue of undertreatment and poor clinical outcomes without intervention, numerous structural tricuspid interventional devices have been and are in development, a challenging process due to the unique anatomic and physiological characteristics of the tricuspid valve, and warranting well-designed clinical trials. The path from routine practice TR detection to appropriate TR evaluation, to conduction of clinical trials, to enriched therapeutic possibilities for improving TR access to treatment and outcomes in routine practice is complex. Therefore, this paper summarizes the key points and methods crucial to TR detection, quantitation, categorization, risk-scoring, intervention-monitoring, and outcomes evaluation, particularly of right-sided function, and to clinical trial development and conduct, for both interventional and surgical groups.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Diagnóstico por Imagem , Valor Preditivo dos Testes , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Ensaios Clínicos como Assunto
7.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37624856

RESUMO

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Cateterismo Cardíaco
8.
J Cardiovasc Comput Tomogr ; 18(1): 26-32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38105119

RESUMO

BACKGROUND: The role of assessment of mitral annular calcification (MAC) using cardiac computed tomography (CCT) in mitral transcatheter edge-to-edge repair (TEER) remains unclear. The aim of this study was to investigate the association of MAC assessed by CCT with procedural and clinical outcomes in patients undergoing TEER. METHODS: We retrospectively analyzed 275 patients who underwent pre-procedural CCT prior TEER. Mitral calcium volume (MCV) and MAC score were measured by CCT. Functional procedural success was defined as residual mitral regurgitation of ≤2+ with mean transmitral gradient of <5 â€‹mmHg at discharge. All-cause mortality within two years after TEER was collected. RESULTS: MAC was present in 115 of 275 patients (41.8 %). The median MCV was 198 â€‹mm3 (interquartile range [IQR]: 84 to 863 â€‹mm3), and the median MAC score was 3 (IQR: 2 to 4). Higher MCV and MAC score were inversely related to the rate of functional procedural success, independently of anatomical features of mitral valve. Patients with moderate/severe MAC, defined as MAC score of ≥4, had a lower rate of functional procedural success than those without MAC (56.1 â€‹% vs. 81.3 â€‹%; p â€‹= â€‹0.002). Moreover, higher MCV and MAC score were associated with a higher risk of all-cause mortality within two years, irrespective of baseline characteristics and functional procedural success. CONCLUSIONS: The presence and burden of MAC assessed by CCT were associated with procedural and clinical outcomes in patients undergoing TEER. The CCT-based assessment of MAC may improve patient selection for TEER.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valor Preditivo dos Testes , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Tomografia
9.
Echocardiography ; 40(11): 1227-1236, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37788148

RESUMO

OBJECTIVE: To evaluate the role of the CT-derived angle between the intra-atrial septum (IAS) and the left atrial appendage (LAA) on procedural complexity and clinical outcomes in left atrial appendage occlusion (LAAO) procedures. BACKGROUND: Given the broad variations in anatomy, LAAO remains one of the most challenging interventional procedures in structural heart disease. In recent years, preprocedural cardiac tomography (CT) has evolved as a valuable tool; however, prediction of procedural complexity remains cumbersome. METHODS: We retrospectively analyzed 47 patients that underwent LAAO at our center in whom pre-procedural cardiac CT-scans were available. Among other baseline parameters, we measured the angle between the LAA ostium and the preferred transseptal puncture site at the IAS. We compared patients with an angle above and below the median regarding procedural characteristics and procedural outcome. RESULTS: The median angle between the LAA and the IAS was 127.3° (IQR: 120.9-141.3). LAAO took longer in patients with a measured angle below the median (55.0 ± 22.7 min vs. 41.3 ± 17.5 min; p = .04), resulting in longer radiation times (13.0 ± 5.3 min vs. 9.8 ± 5.7 min; p = .04) and more contrast use (61.1 ± 47.5 mL vs. 33.6 ± 24.7 mL; p = .05). Moreover, the necessity for a sheath exchange was significantly higher (30.4% vs. 4.2%, p = .02) and device repositioning or device resizing trended to be more frequent (26.1% vs. 8.3%; p = .1 and 21.7% vs. 8.3%; p = .2). There were no differences in procedural outcome, device-position and peri-device leak (PDL). CONCLUSIONS: The angle between the transseptal puncture site and the LAA ostium may serve as a predictor for more demanding LAAO interventions. In our study a steeper angle led to a prolonged procedure resulting in higher doses of contrast and radiation, but was not associated with a worse procedural outcome.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Tomografia , Tomografia Computadorizada por Raios X
10.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

12.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37119968

RESUMO

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Remodelação Ventricular , Índice de Gravidade de Doença
13.
Basic Res Cardiol ; 118(1): 6, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36723728

RESUMO

Aortic valve stenosis (AS) development is driven by distinct molecular and cellular mechanisms which include inflammatory pathways. Toll-like-receptor-3 (TLR3) is a lysosomal pattern-recognition receptor that binds double-stranded RNA and promotes pro-inflammatory cellular responses. In recent years, TLR3 has emerged as a major regulator of vascular inflammation. The exact role of TLR3 in the development of AS has not been investigated. Isolated human valvular interstitial cells (VICs) were stimulated with the TLR3-agonist polyIC and the resulting pro-inflammatory and pro-osteogenic response measured. Severe AS was induced in wildtype- and TLR3-/- mice via mechanical injury of the aortic valve with a coronary springwire. TLR3 activation was achieved by polyIC injection every 24 h after wire injury, while TLR3 inhibition was realized using Compound 4a (C4a) every 48 h after surgery. Endothelial mesenchymal transition (EndoMT) of human valvular endothelial cells (VECs) was assessed after polyIC stimulation. Stimulation of human VICs with polyIC promoted a strong inflammatory and pro-osteogenic reaction. Similarly, injection of polyIC marginally increased AS development in mice after wire injury. AS induction was significantly decreased in TLR3-/- mice, confirming the role of endogenous TLR3 ligands in AS pathology. Pharmacological inhibition of TLR3 with C4a not only prevented the upregulation of inflammatory cytokines and osteogenic markers in VICs, and EndoMT in VECs, but also significantly abolished the development of AS in vivo. Endogenous TLR3 activation significantly contributes to AS development in mice. Pharmacological inhibition of TLR3 with C4a prevented AS formation. Therefore, targeting TLR3 may be a viable treatment option.


Assuntos
Estenose da Valva Aórtica , Calcinose , Humanos , Camundongos , Animais , Estenose da Valva Aórtica/genética , Valva Aórtica/patologia , Células Endoteliais/metabolismo , Receptor 3 Toll-Like/metabolismo , Células Cultivadas , Calcinose/genética , Calcinose/metabolismo , Calcinose/patologia
15.
Cardiovasc Revasc Med ; 49: 42-46, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36609100

RESUMO

BACKGROUND: Recently, the Chronic Kidney Disease-Epidemiology Collaboration working group has published new formulas for race-independent estimation of glomerular filtration rate (GFR). We investigated the old and new eGFR equations in patients transcatheter aortic valve implantation (TAVI). METHODS: We conducted a retrospective analysis based on the data from a prospective registry of patients who underwent TAVI from January 2008 to May 2019. The primary endpoint was 30-day mortality after TAVI, and the secondary endpoints included one- and three-year mortality. RESULTS: In total, 1792 patients undergoing TAVI were included in the present analysis. The thirty-day mortality was 4.6 % (95 % CI 3.8-5.7 %), and the one- and three-year mortality were 17.5 % (95 % CI 15.7-19.4 %) and 34.4 % (95 % CI 32.0-37.0 %). After the application of the new eGFR formula, 12.0 % of patients were reclassified within the GFR category in CKD, while 13.2 % of patients were reclassified within the GFR categories of the EuroSCORE II. Hazard ratios for 30-day, one-year, and three-year mortality increased after introduction of the new creatine-based eq. (1.51, 1.52, 1.49 vs. 1.87, 1.79, 1.74, respectively). Compared to the old equation, the new eGFR <60 ml/min/1.73 m2 had a better discrimination ability for the 30-day mortality (Harell's C: 0.563 (95 % CI 0.518-0.608) vs, 0.583 (95 % CI 0.546-0.636); delta Harell's C, 0.031 ± 0.022, p < 0.001). Similar findings were consistently observed in the cystatin creatinine-based equations. CONCLUSIONS: The application of the new race-independent estimators of GFR results in the reassessment of renal function in a significant proportion of TAVI patients and may influence the risk stratification of this population.


Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Medição de Risco , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Taxa de Filtração Glomerular , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Creatinina
16.
Sleep Breath ; 27(2): 599-610, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35725864

RESUMO

PURPOSE: The relationship between chronic heart failure and sleep-disordered breathing (SDB) has been frequently described. However, little is known about the association of mitral regurgitation (MR) and SDB or the impact of transcatheter mitral valve repair (TMVR) on SDB. Our aims were first to determine the prevalence of SDB in patients with MR, and second to determine the effect of TMVR on SDB. METHODS: Patients with MR being evaluated for TMVR at the University Hospital Bonn underwent polygraphy (PG) to determine the prevalence of SDB. After TMVR, a subset of patients was followed up with transthoracic echocardiography (TTE) and PG to evaluate the effect of TMVR on SDB. RESULTS: In 53 patients, mean age was 76.0 ± 8.5 years and 62% were male. Patients predominantly had more than moderate mitral regurgitation (94%). SDB was highly prevalent (68%) with predominantly central sleep apnoea (CSA, 67%). After TMVR in 15 patients, the apnoea/hypopnoea index (AHI) and central apnoea index (AI) were significantly reduced among patients with SDB (AHI - 8.0/h, p = 0.021; central AI - 6.9/h, p = 0.046). The left atrial volume index (LAVI) at baseline was significantly higher in patients with CSA than in patients with obstructive sleep apnoea (OSA) and was significantly reduced after TMVR (63.5 ml/m2 ± 27.2 vs. 38.3 ml/m2 ± 13.0; - 18.4 ml/m2, p = 0.027). CONCLUSION: SDB, especially CSA, is highly prevalent in patients with mitral regurgitation. In the follow-up cohort TMVR led to a significant reduction of the AHI, predominantly of central events. The findings of the study suggest that TMVR may be a suitable therapy not only for MR but also for the accompanying CSA. LAVI may be a useful indicator for CSA in patients with MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Síndromes da Apneia do Sono , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Prevalência , Resultado do Tratamento , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Síndromes da Apneia do Sono/terapia
17.
Front Cardiovasc Med ; 9: 976822, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36119730

RESUMO

Background: Transcatheter tricuspid valve repair (TTVr) is routinely performed under general anesthesia (GA). This study aimed to investigate whether TTVr procedures can be performed effectively and safely without GA but using deep sedation (DS). Methods: We performed a retrospective analysis of 104 patients from three centers who underwent TTVr between 2020 and 2021. The primary performance endpoints were technical success and severity of TR assessed at the time of discharge. The safety outcome was a composite of in-hospital complications, including occurrence of death, conversion to surgery, major adverse cardiac and cerebrovascular events, major vascular complications, or occurrence of pneumonia. Results: Sixty-four procedures were performed in GA and 40 procedures were performed in DS. The groups did not differ in age, EuroScore II, TR severity, ventricular function, or hemodynamic parameters. Technical success was achieved in 92.5% of the patients in the DS group and in 93.6% of the patients in the GA group (p = 0.805). In none of the patients intraprocedural conversion from DS to GA was required. There was no difference in total duration of the procedure, and number of devices implanted. The degree of TR was ≤2+ in 77.5% of the patients in the DS group and in 74.2% of the patients in the GA group (p = 0.705). The composite safety endpoint did not differ between the groups (2.5 vs. 6.3%, p = 0.384). The total duration of hospital stay was shorter in patients who underwent TTVr in DS compared to those who underwent TTVr in GA (6 [5, 9] days vs. 8 [6, 11] days; p = 0.011). Conclusion: Performing TTVr in DS was effective with similar procedural results, and was safe with similar low complication rates compared to GA.

18.
JACC Cardiovasc Interv ; 15(19): 1936-1945, 2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-36008268

RESUMO

BACKGROUND: Little is known about the incidence and clinical relevance of postprocedural acute kidney injury (AKI) in patients undergoing transcatheter edge-to-edge repair (TEER) for tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to investigate the prognostic impact of postprocedural AKI following TEER for TR. METHODS: Two hundred sixty-eight patients who underwent TEER for TR at 2 centers were retrospectively analyzed. Postprocedural AKI was defined as an increase in serum creatinine of ≥0.3 mg/dL within 48 hours or ≥50% within 7 days after the procedure compared with baseline. The association between AKI and the composite outcome, consisting of all-cause mortality and rehospitalization for heart failure within 1 year after the procedure, was determined. RESULTS: The mean age of the patients was 79.0 ± 6.8 years, and 43.3% were men. Postprocedural AKI occurred in 42 patients (15.7%). Age, male sex, an estimated glomerular filtration rate of <60 mL/min/1.73 m2, and absence of procedural success were associated with the occurrence of AKI. Patients with AKI had a higher incidence of in-hospital mortality than those without AKI (9.5% vs 0.9%; P = 0.006). Moreover, AKI was associated with the incidence of the composite outcome within 1 year after TEER for TR (adjusted HR: 2.39; 95% CI: 1.45-3.94; P = 0.001). CONCLUSIONS: Postprocedural AKI occurred in 15.7% of patients undergoing TEER for TR, despite the absence of iodinated contrast agents, which was associated with worse clinical outcomes. These findings highlight the clinical impact of AKI following TEER for TR and should help in identifying patients at high risk for AKI.


Assuntos
Injúria Renal Aguda , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Meios de Contraste/efeitos adversos , Creatinina , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Arterioscler Thromb Vasc Biol ; 42(10): 1220-1228, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36004640

RESUMO

Growing evidence suggests that ceramides play an important role in the development of atherosclerotic and valvular heart disease. Ceramides are biologically active sphingolipids that are produced by a complex network of enzymes. Lowering cellular and tissue levels of ceramide by inhibiting the ceramide-producing enzymes counteracts atherosclerotic and valvular heart disease development in animal models. In vascular tissues, ceramides are produced in response to hyperglycemia and TNF (tumor necrosis factor)-α signaling and are involved in NO-signaling and inflammation. In humans, elevated blood ceramide levels are associated with cardiovascular events. Furthermore, important cardiovascular risk factors, such as obesity and diabetes, have been linked to ceramide accumulation. This review summarizes the basic mechanisms of how ceramides drive cardiovascular disease locally and links these findings to the intriguing results of human studies on ceramides as biomarkers for cardiovascular events. Moreover, we discuss the current state of interventions to therapeutically influence vascular ceramide metabolism, both locally and systemically.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Doenças das Valvas Cardíacas , Animais , Aterosclerose/metabolismo , Biomarcadores , Ceramidas , Humanos , Esfingolipídeos/metabolismo , Fator de Necrose Tumoral alfa
20.
JACC Cardiovasc Interv ; 15(16): 1639-1648, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35981838

RESUMO

BACKGROUND: Contrast-induced nephropathy (CIN) can occur after cardiovascular procedures using contrast media, which is associated with increased morbidity and mortality. RenalGuard is a closed-loop system designed to match intravenous hydration with diuretic-induced diuresis that has shown mixed results in the prevention of CIN in previous randomized controlled trials. OBJECTIVES: The STRENGTH (Study Evaluating the Use of RenalGuard to Protect Patients at High Risk of AKI) study assessed whether RenalGuard (PLC Medical Systems) is superior to standard intravenous hydration for CIN prevention in patients with chronic kidney disease undergoing complex cardiovascular procedures. METHODS: STRENGTH is a multicenter, international, open-label, postmarket, prospective, randomized (1:1) study monitored by the Cardiovascular European Research Center (Massy, France) that included a total of 259 patients with moderate to severe chronic kidney disease (estimated glomerular filtration 15-40 mL/min/m2) requiring a complex coronary, structural, or peripheral procedure with an expected contrast injection of at least 3 times the estimated glomerular filtration rate. Patients were randomized to either RenalGuard or intravenous saline hydration according to current guidelines. RESULTS: The primary endpoint, the incidence of CIN at day 3 after the procedure, was similar between the 2 groups (17/107 [15.9%] in the RG group vs 15/110 [13.9%] in the control group; P = 0.62). In addition, none of the secondary endpoints differed between the 2 groups. CONCLUSIONS: In high-risk patients undergoing complex cardiovascular interventions in experienced centers, furosemide-induced high urine output with matched hydration using the RenalGuard system did not reduce the risk of CIN and adverse outcomes at 12 months compared with conventional intravenous hydration.


Assuntos
Injúria Renal Aguda , Insuficiência Renal Crônica , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/prevenção & controle , Meios de Contraste/efeitos adversos , Angiografia Coronária , Hidratação/efeitos adversos , Humanos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA