Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Imaging ; 13(5): e009901, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32408830

RESUMO

Background Cardiac amyloidosis (CA) is a disease of interstitial myocardial infiltration, usually by light chains or transthyretin. We used diffusion tensor cardiovascular magnetic resonance (DT-CMR) to noninvasively assess the effects of amyloid infiltration on the cardiac microstructure. Methods DT-CMR was performed at diastole and systole in 20 CA, 11 hypertrophic cardiomyopathy, and 10 control subjects with calculation of mean diffusivity, fractional anisotropy, and sheetlet orientation (secondary eigenvector angle). Results Mean diffusivity was elevated and fractional anisotropy reduced in CA compared with both controls and hypertrophic cardiomyopathy (P<0.001). In CA, mean diffusivity was correlated with extracellular volume (r=0.68, P=0.004), and fractional anisotropy was inversely correlated with circumferential strain (r=-0.65, P=0.02). In CA, diastolic secondary eigenvector angle was elevated, and secondary eigenvector angle mobility was reduced compared with controls (both P<0.001). Diastolic secondary eigenvector angle was correlated with amyloid burden measured by extracellular volume in transthyretin, but not light chain amyloidosis. Conclusions DT-CMR can characterize the microstructural effects of amyloid infiltration and is a contrast-free method to identify the location and extent of the expanded disorganized myocardium. The diffusion biomarkers mean diffusivity and fractional anisotropy effectively discriminate CA from hypertrophic cardiomyopathy. DT-CMR demonstrated that failure of sheetlet relaxation in diastole correlated with extracellular volume in transthyretin, but not light chain amyloidosis. This indicates that different mechanisms may be responsible for impaired contractility in CA, with an amyloid burden effect in transthyretin, but an idiosyncratic effect in light chain amyloidosis. Consequently, DT-CMR offers a contrast-free tool to identify novel pathophysiology, improve diagnostics, and monitor disease through noninvasive microstructural assessment.


Assuntos
Neuropatias Amiloides Familiares/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Imagem de Tensor de Difusão , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Miocárdio/patologia , Idoso , Neuropatias Amiloides Familiares/patologia , Neuropatias Amiloides Familiares/fisiopatologia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Cardiomiopatia Hipertrófica/patologia , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/patologia , Amiloidose de Cadeia Leve de Imunoglobulina/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
2.
Magn Reson Med ; 83(2): 712-730, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31441550

RESUMO

PURPOSE: Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementation of an automated solution for inline perfusion flow mapping with step by step performance characterization. METHODS: Proposed workflow consists of motion correction (MOCO), arterial input function blood detection, intensity to gadolinium concentration conversion, and pixel-wise mapping. A distributed kinetics model, blood-tissue exchange model, is implemented, computing pixel-wise maps of myocardial blood flow (mL/min/g), permeability-surface-area product (mL/min/g), blood volume (mL/g), and interstitial volume (mL/g). RESULTS: Thirty healthy subjects (11 men; 26.4 ± 10.4 years) were recruited and underwent adenosine stress perfusion cardiovascular MR. Mean MOCO quality score was 3.6 ± 0.4 for stress and 3.7 ± 0.4 for rest. Myocardial Dice similarity coefficients after MOCO were significantly improved (P < 1e-6), 0.87 ± 0.05 for stress and 0.86 ± 0.06 for rest. Arterial input function peak gadolinium concentration was 4.4 ± 1.3 mmol/L at stress and 5.2 ± 1.5 mmol/L at rest. Mean myocardial blood flow at stress and rest were 2.82 ± 0.47 mL/min/g and 0.68 ± 0.16 mL/min/g, respectively. The permeability-surface-area product was 1.32 ± 0.26 mL/min/g at stress and 1.09 ± 0.21 mL/min/g at rest (P < 1e-3). Blood volume was 12.0 ± 0.8 mL/100 g at stress and 9.7 ± 1.0 mL/100 g at rest (P < 1e-9), indicating good adenosine vasodilation response. Interstitial volume was 20.8 ± 2.5 mL/100 g at stress and 20.3 ± 2.9 mL/100 g at rest (P = 0.50). CONCLUSIONS: An inline perfusion flow mapping workflow is proposed and demonstrated on normal volunteers. Initial evaluation demonstrates this fully automated solution for the respiratory MOCO, arterial input function left ventricle mask detection, and pixel-wise mapping, from free-breathing myocardial perfusion imaging.


Assuntos
Algoritmos , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Adolescente , Adulto , Área Sob a Curva , Automação , Meios de Contraste , Circulação Coronária , Feminino , Voluntários Saudáveis , Frequência Cardíaca , Ventrículos do Coração , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Masculino , Movimento (Física) , Reconhecimento Automatizado de Padrão , Adulto Jovem
3.
J Cardiovasc Magn Reson ; 19(1): 43, 2017 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-28385161

RESUMO

BACKGROUND: Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. METHODS: A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. RESULTS: For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19 ml/min/g using the BTEX model and 3.4 ± 0.39 and 0.95 ± 0.16 using a Fermi model, for stress and rest, respectively. CONCLUSIONS: A dual sequence for myocardial perfusion cardiovascular magnetic resonance and AIF measurement has been optimized for quantification of myocardial blood flow. A validation in phantoms was performed to confirm that the signal conversion to gadolinium concentration was linear. The proposed sequence was integrated with a fully automatic in-line solution for pixel-wise mapping of myocardial blood flow and evaluated in adenosine stress and rest studies on N = 29 normal healthy subjects. Reliable perfusion mapping was demonstrated and produced estimates with low variability.


Assuntos
Circulação Coronária , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Automação , Velocidade do Fluxo Sanguíneo , Meios de Contraste/administração & dosagem , Voluntários Saudáveis , Humanos , Imagem de Perfusão do Miocárdio/instrumentação , Dinâmica não Linear , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Vasodilatadores/administração & dosagem
4.
J Cardiovasc Magn Reson ; 12: 17, 2010 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-20346110

RESUMO

BACKGROUND: Multi-contrast weighted cardiovascular magnetic resonance (CMR) allows detailed plaque characterisation and assessment of plaque vulnerability. The aim of this preliminary study was to show the potential of Ultra-short Echo Time (UTE) subtraction MR in detecting calcification. METHODS: 14 ex-vivo human carotid arteries were scanned using CMR and CT, prior to histological slide preparation. Two images were acquired using a double-echo 3D UTE pulse, one with a long TE and the second with an ultra-short TE, with the same TR. An UTE subtraction (DeltaUTE) image containing only ultra-short T2 (and T2*) signals was obtained by post-processing subtraction of the 2 UTE images. The DeltaUTE image was compared to the conventional 3D T1-weighted sequence and CT scan of the carotid arteries. RESULTS: In atheromatous carotid arteries, there was a 71% agreement between the high signal intensity areas on DeltaUTE images and CT scan. The same areas were represented as low signal intensity on T1W and areas of void on histology, indicating focal calcification. However, in 15% of all the scans there were some incongruent regions of high intensity on DeltaUTE that did not correspond with a high intensity signal on CT, and histology confirmed the absence of calcification. CONCLUSIONS: We have demonstrated that the UTE sequence has potential to identify calcified plaque. Further work is needed to fully understand the UTE findings.


Assuntos
Calcinose/diagnóstico , Doenças das Artérias Carótidas/diagnóstico , Artéria Carótida Primitiva/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Magn Reson Med ; 57(1): 74-81, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17191248

RESUMO

(23)Na MRI has the potential to noninvasively detect sodium (Na) content changes in vivo. The goal of this study was to implement (23)Na MRI in a clinical setting for neurooncological and muscular imaging. Due to the biexponential T(2) decay of the tissue Na signal with a short component, which ranges between 0.5-8 ms, the measurement of total Na content requires imaging techniques with echo times (TEs) below 0.5 ms. A 3D radial pulse sequence with a TE of 0.2 ms at a spatial resolution of 4 x 4 x 4 mm(3) was developed that allows the acquisition and presentation of Na images on the scanner. This sequence was evaluated in patients with low- and high-grade gliomas, and higher (23)Na MR signals corresponding to an increased Na content were found in the tumor regions. The contrast-to-noise ratio (CNR) between tumor and white matter increased from 0.8 +/- 0.2 to 1.3 +/- 0.3 with tumor grade. In patients with an identified muscular (23)Na channelopathy (Paramyotonia congenita (PC)), induced muscle weakness led to a signal increase of approximately 18% in the (23)Na MR images, which was attributed to intracellular Na(+) accumulation in this region.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Transtornos Miotônicos/diagnóstico , Sódio/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/metabolismo , Estudos de Viabilidade , Glioma/metabolismo , Humanos , Imageamento por Ressonância Magnética/instrumentação , Pessoa de Meia-Idade , Transtornos Miotônicos/metabolismo , Projetos Piloto , Valores de Referência , Sódio/análise , Isótopos de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA