Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Sci Rep ; 12(1): 1418, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082374

RESUMO

This study aimed to evaluate the robustness against geometric uncertainties in the hybrid intensity-modulated radiation therapy (IMRT) plans generated by commercially available software for automated breast planning (ABP). The ABP plans were compared with commonly used forward-planned field-in-field (FIF) technique plans. The planning computed tomography datasets of 20 patients who received left-sided breast-conserving surgery were used for both the ABP and FIF plans. Geometric uncertainties were simulated by shifting beam isocenters by 2, 3, 5, and 10 mm in the six directions: anterior/posterior, left/right, and superior/inferior. A total of 500 plans (20 patients and 25 scenarios, including the original plan) were created for each of the ABP and FIF plans. The homogeneity index of the target volume in the ABP plans was significantly better (p < 0.001) than the value in the FIF plans in the scenarios of shifting beam isocenters by 2, 3, and 5 mm. Mean heart dose and percentage volume of lungs receiving a dose more than 20 Gy were clinically acceptable in all scenarios. The hybrid IMRT plans generated by commercially available ABP software provided better robustness against geometric uncertainties than forward-planned FIF plans.


Assuntos
Neoplasias da Mama/radioterapia , Glândulas Mamárias Humanas/efeitos da radiação , Mastectomia Segmentar/métodos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/métodos , Software , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Relação Dose-Resposta à Radiação , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Glândulas Mamárias Humanas/diagnóstico por imagem , Glândulas Mamárias Humanas/patologia , Glândulas Mamárias Humanas/cirurgia , Órgãos em Risco , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
2.
Cureus ; 13(9): e17743, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34659956

RESUMO

Aim To investigate the variation of tumor volume during moderate hypo-fractionated stereotactic body radiation therapy (SBRT). Patients and Methods Twenty patients, who received SBRT at our institution, were included in the analysis. A prescribed dose was 56 Gy at iso-center in seven fractions. Tumor volumes before and during SBRT were calculated. In order to investigate factors affecting the variation of tumor volume in RT 2 (after first irradiation) and RT 7 (after last irradiation), various parameters were verified by the Mann-Whitney U test. Results With regard to the low maximum standardized uptake values (SUVmax) group, transient increase of tumor volume was found in RT 2, and tumor volume reduction was hardly found in RT 7. With regard to the high SUVmax group, a transient increase was not found, and a definite reduction was found in the treatment course. Conclusion Accurate prediction of tumor volume variation is required for more accurate treatment, such as adaptive radiation therapy.

3.
Gan To Kagaku Ryoho ; 48(2): 239-241, 2021 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-33597368

RESUMO

BACKGROUND: Preoperative chemoradiotherapy(CRT)followed by total mesorectal excision(TME)is used for locally advanced rectal cancer, but it can induce postoperative anorectal function. The primary objective of this study is to confirm the efficacy and safety of preoperative CRT and TME without irradiation to the internal and external sphincter muscles. SUBJECTS AND METHODS: Patients were eligible for this study if they met the following inclusion criteria: histologically proven rectal cancer, clinical T3T4N0-2 disease, and a distance between anal margin of tumor and the rental line is more than 2 cm. Twelve patients who underwent preoperative CRT and TME between 2013 and 2017 were enrolled. The primary endpoint was completion rate of sphincter-preserving surgery. RESULTS: All patients completed preoperative CRT without Grade 3 or higher adverse effect. Sphincter-preserving surgery was performed in all cases. The 5-year disease-free survival rate was 46.7%, and the local recurrence-free survival rate was 75%, and the overall survival rate was 90.9%. CONCLUSION: It is suggested that preoperative CRT and TME without irradiation to the internal and external sphincter muscles is effective and safe therapy for locally advanced rectal cancer.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Quimiorradioterapia , Humanos , Neoplasias Retais/cirurgia , Reto , Resultado do Tratamento
4.
Cancer Diagn Progn ; 1(3): 193-200, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35399314

RESUMO

Background/Aim: The most severe adverse event of radiotherapy in lung cancer is radiation pneumonitis (RP). Some indices commonly used to prevent RP are evaluated based on the anatomical lung volume. The irradiation dose may be more accurately assessed by using functional lung volume. We evaluated the usefulness of computed tomography (CT) incorporating functional ventilation images acquired by the inhalation of xenon (Xe) gas (Xe-CT functional images). Patients and Methods: Two plans were created for twelve patients: volumetric modulated arc therapy (VMAT) planning using conventional chest CT images (anatomical plans) and VMAT planning using Xe-CT functional images (functional plans), and the dosimetric parameters were compared. Results: Compared to the anatomical plans, the functional plans had significantly reduced V 20Gy in the high-functional lungs (p=0.005), but significant differences were not seen in the moderate-functional and low-functional lungs. Conclusion: The incorporation of Xe-CT functional images into VMAT plans enables radiotherapy planning with consideration of lung function.

5.
J Xray Sci Technol ; 28(2): 243-254, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31985486

RESUMO

OBJECTIVE: Since most radiation treatment plans are based on computed tomography (CT) images, which makes it difficult to define the targeted tumor volume located near a metal implant, this study aims to evaluate and compare three treatment plans in order to optimally reduce geometrical uncertainty in external radiation treatment of localized prostate cancer. METHODS: Experimental subjects were three prostate patients with bilateral hip prosthesis who had undergone radical radiotherapy. The treatment plans were five-field three-dimensional conformal radiation therapy (3D-CRT), fixed 5-field intensity-modulated radiation therapy (IMRT) using similar gantry angles, and single-arc volumetric modulated arc therapy (VMAT). The monitor units (MUs), dose volume histograms (DVHs), the dose indices of planning target volume (PTV), clinical target volume (CTV) and rectum were compared among the three techniques. The geometrical uncertainties were evaluated by shifting the iso-center (2- 10 mm in the anterior, posterior, left, right, superior, and inferior directions). The CTV and rectum dose indexes with and without the iso-center shifts were compared in each plan. RESULTS: The Conformity Index of PTV were 1.35 in 3D-CRT, 1.12 in IMRT, and 1.04 in VMAT, respectively. The rectum doses in 3D-CRT are also higher than those in IMRT and VMAT. The iso-center shift little affected the CTV dose when smaller than the margin size. The rectum dose increased especially after a posterior shift. Additionally, this dose increase was larger in the VMAT plan than in the 3D- CRT plan. However, the VMAT achieved a superior rectum DVH to that of 3D- CRT, and this effect clearly exceeded the rectum-dose increase elicited by the iso-center shift. CONCLUSION: For radiotherapy treatment of localized prostate cancer in patients with hip prosthesis, the dose distribution was better in the VMAT and Metal Artifact Reduction (MAR)-CT image methods than the conventional methods. Because the anatomical structure of the male pelvic region is relatively constant among individuals, we consider that VMAT is a valid treatment plan despite analyzing just three cases.


Assuntos
Prótese de Quadril , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Incerteza , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
6.
Igaku Butsuri ; 40(4): 119-125, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33390377

RESUMO

Using virtual reality (VR) technology such as head-mounted displays, users can be immersed in a virtual world and perceive it as reality. In radiation therapy departments, pretreatment patients and students rarely observe treatment rooms and treatment devices, making it difficult to understand the overall flow of radiation therapy. In this study, to facilitate the understanding and teaching of radiation therapy, we suggest the implementation of VR technology and develop software compatible with VR to enable a pertinent comprehension of radiation therapy. With versatility and accessibility in mind, the software is developed as an application for Android and iOS devices.Omnidirectional movies in treatment rooms were acquired from both the patient view and a third-person view using an omnidirectional camera. The Android/iOS devices used were AQUOS R (SHARP), iPhone 7 Plus (Apple), and iPad air (Apple). The software was developed using Unity 2018.4.7f (Unity Technologies). The main components of the software were as follows: (i) a home window featuring a user interface with which people can access arbitrarily rooms by tapping on floor maps or a list of treatment rooms, (ii) a snapshot mode providing 2D images of a treatment room as a slide show, and (iii) a movie mode displaying omnidirectional movies from the patient view or a third-person view. The virtual radiation therapy experience was executed by attaching the Android/iOS devices to 3D VR goggles (SAMONIC).The main components of the application operated in good conjunction on the Android/iOS devices, and live viewing in the virtual world ran smoothly with the VR technology. However, there were resolution limitations due to the specs of the camera and the devices. It will therefore be necessary to adjust the resolution and the frame rate according to the performance of the relevant devices. The application is instructive for both patients and students because the virtual radiation therapy experience is immersive when using the VR technology. In addition, the developed software can transfer data in a single package and has the ability to substitute images and omnidirectional movies with those appropriate for diagnostic radiology and nuclear medicine departments. Therefore, the developed application is highly versatile.


Assuntos
Radioterapia , Smartphone , Software , Realidade Virtual , Simulação por Computador , Estudos de Viabilidade , Humanos , Aplicativos Móveis
7.
Radiol Phys Technol ; 12(3): 249-259, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31115835

RESUMO

Automated treatment planning may decrease the effort required in planning and promote increased routine clinical use of intensity-modulated radiation therapy (IMRT) for many breast cancer patients. The aim of this study was to evaluate a new commercial automated planning software for tangential breast IMRT by comparing it with clinical plans from whole-breast irradiation. We prospectively enrolled 150 patients with Stage 0-1 breast cancer who underwent breast-conserving surgery at our institution between September 2016 and August 2017. Total doses of 42.56 Gy in 16 fractions (n = 98) or 50 Gy in 25 fractions (n = 44) were used. All treatment plans were retrospectively re-planned using the automated breast planning (ABP) software. All automated plans generated clinically deliverable beam parameters with no patient body collision and no contralateral breast pass through. The mean homogeneity index of the automatically generated clinical target volume, percentage volume of lungs receiving dose more than 20 Gy, mean heart dose, and dose to the highest irradiated 2-cc volumes of the irradiated volume were 0.077 ± 0.019, 4.2% ± 1.2%, 142 ± 69 cGy, and 105.8% ± 1.7% (prescribed dose: 100%), respectively. The mean planning time was 4.8 ± 1.4 min. The ABP software demonstrated high clinical acceptability and treatment planning cost efficiency for tangential breast IMRT. The ABP software may be useful for delivering high-quality treatment to a majority of patients with early-stage breast cancer.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Software , Adulto , Idoso , Automação , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Fatores de Tempo
8.
Australas Phys Eng Sci Med ; 41(4): 1069-1074, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30361917

RESUMO

The objective of this study was to clarify the usefuleness of the K parameters of the independent verification method using V100% (the volume of water receiving 100% of the prescription dose) for institutions implementing the high-dose-rate (HDR) intracavitary brachytherapy for gynecological cancer. The data of 249 plans of 11 institutions in Japan were used, and the constant K value obtained by a parameter fit for single-192Ir, two-192Ir, and three-192Ir systems was calculated. The predicted total dwell time calculated using the constant K value was defined as Tpr, and the total dwell time calculated using a radiation treatment planning system was defined as TRTP. The ratio of Tpr and TRTP for each plan was calculated. The constant K values (95% CI) obtained for each system outlined above were 1233 (1227-1240), 1205 (1199-1211), and 1171 (1167-1175), respectively. Regarding the Tpr/TRTP, the entire data were within 0.9-1.1. For accurate verification, it was clarified that constant K values should be calculated for each system. The Nuclear Regulatory Commission considers a difference of 20% between the prescribed total dose and the administered total dose as a reportable medical event. There is a need for a quick method to verify the accuracy with a minimum of 10% threshold of a plan. The constant K values in this study were obtained from multiple institutions, and the variation in the values among these institutions was small. The data obtained by this study may be used as a parameter of this verification method employed by numerous institutions, particularly those who have recently initiated HDR brachytherapy. In addition, for institutions already using this method, this data might be useful for the validation of the parameters which were used in such institutions.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Medicina de Precisão/métodos , Garantia da Qualidade dos Cuidados de Saúde , Estudos Retrospectivos
9.
J Xray Sci Technol ; 26(3): 473-480, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29562582

RESUMO

PURPOSE: Based on a retrospective analysis, this study aims to develop a simple index for validity of the evaluation point for the dosimetric verification of intensity-modulated radiation therapy (IMRT). METHODS: The results for the dosimetric verifications of a total of 69 IMRT plans were analyzed in this study. A Farmer-type ion chamber was used as a dose detector, and a solid water-equivalent phantom was used. Index values were obtained by dividing the difference between the maximum and minimum dosages by the mean dosage of the 69 plans, and the values were classified into five groups with index value <4, 4-8, 8-12, 12-16, and >16. A t-test was used to assess the statistical significance of the mean differences of the absolute values of the relative errors among these groups. RESULTS: We found that there was no significant difference between the groups with index value <4 and 4-8 (p = 0.152); however, there were significant differences between the other groups (p < 0.01). In addition, when the index values were smaller than 8, the pass ratio of 3% tolerance was 96.2% and the pass ratio of 5% tolerance was 99.9%. We observed that the smaller the index value, the smaller the uncertainty of the dose measurement. CONCLUSIONS: The results obtained in this study may prove to be useful for accurate dosimetric verifications of IMRTs when ion chambers are used.


Assuntos
Dosagem Radioterapêutica/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
J Radiat Res ; 54(1): 135-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22843378

RESUMO

The purpose of this study was to compare the size and clearness of gross tumor volumes (GTVs) of metastatic brain tumors on T1-weighted magnetic resonance images between a single dose contrast administration protocol and a double dose contrast administration protocol to determine the optimum dose of contrast-enhancement for clear delineation of GTV in stereotactic radiotherapy (SRT). A total of 28 small metastatic brain tumors were evaluated in 13 patients by intra-individual comparison of GTV measurements using single dose and double dose contrast-enhanced thin-slice (1-mm) magnetic resonance imaging (MRI). All patients had confirmed histological types of primary tumors and had undergone hypo-fractionated SRT for metastatic brain tumors. The mean tumor diameter with single dose and double dose contrast-enhancement was 12.0 ± 1.1 mm and 13.2 ± 1.1 mm respectively (P < 0.001). The mean incremental ratio (MIR) obtained by comparing mean tumor diameters was 11.2 ± 0.02 %. The mean volume of GTV-1 (single dose contrast-enhancement) and GTV-2 (double dose contrast-enhancement) was 1.38 ± 0.41 ml and 1.59 ± 0.45 ml respectively (P < 0.01). The MIR by comparing mean tumor volumes was 32.3 ± 0.4 %. The MIR of GTV-1 with < 1 ml volume and GTV-1 with > 1 ml volume was 41.8 ± 0.05 % and 12.4 ± 0.03 % respectively (P < 0.001). We conclude that double dose contrast-enhanced thin-slice MRI is a more useful technique than single dose contrast-enhanced thin-slice MRI, especially for clear delineation of GTVs of small metastatic brain tumors in treatment planning of highly precise SRT.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Idoso , Neoplasias Encefálicas/patologia , Meios de Contraste , Relação Dose-Resposta à Radiação , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Radiometria/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral/efeitos da radiação
11.
Gan To Kagaku Ryoho ; 36(12): 2245-7, 2009 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-20037384

RESUMO

This retrospective study was performed to evaluate the outcomes of 12 patients with brain metastasis from colorectal cancer treated between 1999 and 2008. The range of patients was 33-72 years old (median: 64 years old). The male to female ratio was 2:1. The primary site was the colon in 4 patients and rectum in 8 patients. The site of brain metastasis was the cerebrum in 8 and cerebellum in 4. All brain lesions were metachronously detected. Three patients had a single lesion each, while the remaining 9 had multiple lesions. The range of the period from the resection of the primary lesion to the detection of brain metastasis was 144-2,062 days (median: 868 days). The types of treatment included whole brain radiotherapy after cerebral metastatectomy in three patients with a single lesion, whole brain radiotherapy only in 7 patients with multiple lesions, and modified FOLFOX6 (mFOLFOX6) regimen combined with whole brain radiation in recently treated two patients with multiple brain and lung metastases. The median overall survival period was 107 days. The longest survivor was a patient who survived for 505 days after the start of mFOLFOX6 plus radiation therapy. It appears that how we control metastases has become more important in recent years. For example, using new drugs, extracranial metastases of controllable cancer have become better controllable over longer periods.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Colorretais/patologia , Adulto , Idoso , Neoplasias Encefálicas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
Radiat Med ; 26(7): 396-401, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18769996

RESUMO

PURPOSE: The importance of the quality of life (QOL) and mental condition of patients being treated for cancer is now recognized. In this study, we evaluated QOL and mental condition in patients with cancer before and after radiotherapy. MATERIALS AND METHODS: The subjects were 170 patients who had undergone radiotherapy. The examination of QOL was performed using the quality of life questionnaire for cancer patients treated with anticancer drugs (QOL-ACD), and mental condition (anxiety and depression) was examined using the hospital anxiety and depression scale (HADS). These examinations were performed at the start of radiotherapy and immediately after radiotherapy. RESULTS: The QOL score was slightly higher in all patients after the completion of radiotherapy than before the start of radiotherapy. In the palliative radiotherapy group, QOL score was significantly improved by treatment. Anxiety and depression were improved after radiotherapy. There was a correlation between the degrees of improvement of the HADS and QOL score. CONCLUSION: We could treat cancer patients by radiotherapy without reducing their QOL, and improvement in QOL was significant in the palliative radiotherapy group. Mental condition was also improved after radiotherapy.


Assuntos
Neoplasias da Mama/psicologia , Neoplasias Esofágicas/psicologia , Neoplasias Pulmonares/psicologia , Transtornos Mentais/etiologia , Qualidade de Vida , Neoplasias Urogenitais/psicologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos de Ansiedade/diagnóstico , Transtornos de Ansiedade/etiologia , Transtornos de Ansiedade/psicologia , Atitude Frente a Saúde , Neoplasias da Mama/radioterapia , Transtorno Depressivo/diagnóstico , Transtorno Depressivo/etiologia , Transtorno Depressivo/psicologia , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/radioterapia , Feminino , Humanos , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/radioterapia , Masculino , Transtornos Mentais/diagnóstico , Transtornos Mentais/psicologia , Pessoa de Meia-Idade , Cuidados Paliativos/psicologia , Cuidados Paliativos/estatística & dados numéricos , Escalas de Graduação Psiquiátrica/estatística & dados numéricos , Inquéritos e Questionários , Neoplasias Urogenitais/complicações , Neoplasias Urogenitais/radioterapia , Adulto Jovem
13.
Radiat Med ; 25(2): 73-5, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17541516

RESUMO

We encountered a case of arteriovenous malformation (AVM) of the gallbladder in a patient with hepatocellular carcinoma (HCC). Contrast-enhanced computed tomography (CT) showed serpentine vessels around and within the gallbladder wall. Angiography showed dilated and tortuous cystic arteries, a racemose vascular network, and early-filling cystic veins. Transcatheter arterial embolization of two cystic arteries feeding the AVM was performed with platinum microcoils prior to transcatheter arterial chemoembolization for HCC to prevent embolic particles from flowing into these arteries. Follow-up contrast-enhanced CT showed blood flow in the gallbladder AVM, which appeared to be fed by the arterial collaterals.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Vesícula Biliar/irrigação sanguínea , Idoso , Angiografia , Malformações Arteriovenosas/terapia , Carcinoma Hepatocelular/complicações , Quimioembolização Terapêutica , Circulação Colateral , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/complicações , Tomografia Computadorizada por Raios X
14.
J Agric Food Chem ; 55(3): 812-8, 2007 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-17263479

RESUMO

The pharmacophore of the neonicotinoid insecticide imidacloprid, nitroiminoimidazolidine, was modified to heterocycles such as thiazolidine, pyrrolidine, dihydroimidazole, dihydrothiazole, and pyridone conjugated to nitroimine (=NNO2) or nitromethylene (=CHNO2). Their 6-chloro-3-pyridylmethyl or 5-chloro-3-thiazolylmethyl derivatives were examined for insecticidal activity against the American cockroach by injection and for neuroblocking activity using the cockroach ganglion. Most of the compounds having the neonicotinoidal pharmacophore exhibited insecticidal activity at the nanomolar level, which was enhanced in the presence of synergists, and high neuroblocking activity at the micromolar level. Quantitative analysis for the compounds showed that the neuroblocking potency is proportional both to the Mulliken charge on the nitro oxygen atom and to the partition coefficient log P value. The equation for the insecticidal versus neuroblocking potencies indicated that both potencies are related proportionally with each other when the other factors are the same.


Assuntos
Anabasina/química , Imidazóis/química , Imidazolidinas/química , Inseticidas , Sistema Nervoso/efeitos dos fármacos , Nitrocompostos/química , Animais , Fenômenos Químicos , Físico-Química , Baratas , Imidazolidinas/farmacologia , Neonicotinoides , Relação Estrutura-Atividade
15.
Int Arch Allergy Immunol ; 142(4): 301-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17135761

RESUMO

BACKGROUND: The major dog allergens, Can f 1 and Can f 2, are members of the lipocalin protein family. The characterization of both dog allergens is still not complete. Their deduced amino acid sequences indicate the presence of three cysteine residues, probably connected with a disulfide bridge. We compared the biochemical and immunological properties of Can f 1 with those of Can f 2 using gel filtration, electrophoresis, and immunological assays. METHODS: The rCan f 1, rCan f 2 and dog salivary proteins containing natural Can f 1 and Can f 2 were analyzed by HPLC gel filtration. The recombinant Can f 1 (rCan f 1) and rCan f 2 were analyzed by native and sodium dodecyl sulfate (SDS) polyacrylamide gel electrophoresis (PAGE) with or without reduction. The binding ability of rabbit IgG purified by protein G affinity chromatography from the antiserum against rCan f 1 and rCan f 2 was examined after a reduction in the recombinant allergens. The immunological cross-reaction between rCan f 1 and rCan f 2 was examined by an enzyme-linked immunosorbent assay (ELISA) using the rabbit IgG against rCan f 1 and rCan f 2. The cross-reaction of human IgE in the serum of a patient with dog allergy between rCan f 1 and rCan f 2 was also analyzed by competitive ELISA. RESULTS: The molecular weights of rCan f 1 and of rCan f 2 were 18 and 21 kDa, respectively, using SDS-PAGE under reducing conditions, but the natural Can f 1 and Can f 2 were separated by HPLC gel filtration into fractions containing proteins of 31 and 34 kDa, respectively. rCan f 1 and rCan f 2 migrated as multiple bands (30-100 kDa) in native PAGE in the presence or absence of a reductant. The molecular weights of natural Can f 1 and of Can f 2 were 20 and 23 kDa, respectively, in SDS-PAGE under reducing conditions. The ability of rabbit IgG to bind to rCan f 1 and rCan f 2 increased after the reduction of the recombinant allergens. The rabbit IgG against rCan f 1 bound to rCan f 2. Cross-reaction of human IgE was observed between rCan f 1 and rCan f 2. CONCLUSIONS: In the native and recombinant forms, Can f 1 and Can f 2 possessed a dimer structure under natural (non-reduced) condition. The dimers of Can f 1 and of Can f 2 were not built with a disulfide bridge but by non-covalent association. Cleavage of a disulfide bond of rCan f 1 and rCan f 2 increased the ability of binding of rabbit IgG to the allergens. The cross-reactivity of rabbit IgG and human IgE between rCan f 1 and rCan f 2 indicates that the same epitope(s) was present in Can f 1 and Can f 2.


Assuntos
Alérgenos/imunologia , Alérgenos/genética , Animais , Antígenos de Plantas , Cromatografia Líquida de Alta Pressão , Reações Cruzadas , Cães , Eletroforese em Gel de Poliacrilamida , Ensaio de Imunoadsorção Enzimática , Humanos , Immunoblotting , Imunoglobulina E/imunologia , Imunoglobulina G/imunologia , Coelhos , Proteínas Recombinantes/imunologia , Proteínas e Peptídeos Salivares/genética , Proteínas e Peptídeos Salivares/imunologia
16.
Biosci Biotechnol Biochem ; 69(4): 705-13, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15849408

RESUMO

Prodrug-oriented molecular design was attempted for the potent acyclic neonicotinoid insecticide, clothianidin (1-(2-chloro-5-thiazolylmethyl)-3-methyl-2-nitroguanidine). Molecules bearing a CH2COCH2 bridge linking the 1,3-NH ends of clothianidin or their acetals would possibly be hydrolyzed, regenerating the mother compounds. This strategy was used to prepare seven acetals of clothianidin-based molecules that combined 2-chloro-5-thiazolylmethyl, 6-chloro-3-pyridylmethyl or 3-tetrahydrofurfuryl with a nitroimine, cyanoimine or nitromethylene group. The key intermediate, 1,3-diamino-2,2-dimethoxypropane, was prepared from the dihydroxyacetone dimer in four steps. A selected acetal showed a characteristic nerve-impulse pattern for neonicotinoids on an excised American cockroach ganglion, although the neuroblocking activity was fairly low. Some acetals were highly insecticidal against the pea aphid at 0.8-20 ppm 7 days after a spray treatment, this being in a contrast to their far weaker activity by injection into American cockroaches. The biological results suggest that the intrinsic insecticidal activities of the acetals are weak, but would exhibit enhanced activity if hydrolyzed in an external environment.


Assuntos
Compostos Aza/química , Compostos Aza/farmacologia , Cicloexanos/química , Cicloexanos/farmacologia , Imidazóis/química , Inseticidas/síntese química , Inseticidas/farmacologia , Nicotina/química , Pró-Fármacos/química , Acetais/química , Animais , Afídeos/efeitos dos fármacos , Compostos Aza/síntese química , Cicloexanos/síntese química , Desenho de Fármacos , Hidrólise , Inseticidas/química , Estrutura Molecular , Neonicotinoides , Nicotina/síntese química , Nicotina/farmacologia , Nitrocompostos , Pró-Fármacos/síntese química , Relação Estrutura-Atividade
17.
Ann Nucl Med ; 18(2): 157-60, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15195764

RESUMO

We report a case of esophageal carcinoma that showed extraosseous accumulation of 99mTc-MDP in lymph node metastases to the cervical and paracardial lymph nodes. There are few cases showing abnormal extraosseous accumulation of 99mTc-MDP in esophageal cancer lesion. The patient was a 53-year-old man with advanced esophageal cancer. Bone scintigraphy demonstrated extraosseous accumulations in left supraclavicular and paracardial lymph node metastases. The histopathological diagnosis was small cell carcinoma of the esophagus, which is a rare disease with aggressive behavior and poor prognosis. Our patient underwent 2 courses of systemic chemotherapy (CDDP + VP16), but died of rapidly growing systemic metastases 5 months after the initial treatment.


Assuntos
Carcinoma de Células Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/metabolismo , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/metabolismo , Medronato de Tecnécio Tc 99m/farmacocinética , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/metabolismo , Carcinoma de Células Pequenas/secundário , Humanos , Achados Incidentais , Linfonodos/diagnóstico por imagem , Linfonodos/metabolismo , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética
18.
J Biochem ; 134(2): 239-44, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12966073

RESUMO

Ascorbate peroxidase (APX) is a heme-containing protein that plays a central role in scavenging H(2)O(2) in higher plants. The structure of stromal APX (sAPX) was determined at 1.6 A to an R-factor of 19.1% and an R-free-factor of 22.3%. The electrostatic potential of the gamma-channel that connects the molecular surface of sAPX to the gamma-edge of heme was more positive than that of cytosolic APX (cAPX) from pea, so sAPX might bind more easily with ascorbate than cAPX. The overall structure of sAPX was similar to those of cAPX from pea and cytochrome c peroxidase (CCP) from yeast, with a substantial difference in a loop structure located in the vicinity of the heme. The side chain of Arg169 in sAPX corresponding to His169 in cAPX and His181 in CCP extended in the opposite direction from the heme, forming two hydrogen bonds with carbonyl groups in the loop structure. The rapid inactivation of sAPX might be due to the characteristic conformation of Arg169 owing to the loop structure of sAPX.


Assuntos
Cloroplastos/enzimologia , Nicotiana/enzimologia , Peroxidases/química , Ascorbato Peroxidases , Sítios de Ligação , Cristalografia por Raios X , Estabilidade Enzimática , Isoenzimas , Modelos Moleculares , Pisum sativum/enzimologia , Estrutura Secundária de Proteína , Eletricidade Estática , Leveduras/enzimologia
19.
Biosci Biotechnol Biochem ; 67(5): 980-8, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12834274

RESUMO

The asymmetric chloronicotinyl insecticide, 1-[1-(6-chloro-3-pyridyl)ethyl]-2-nitroiminoimidazolidine, was prepared, and the absolute configurations of the enantiomers were determined by an X-ray analysis. The insecticidal activity against the housefly measured with metabolic inhibitors showed the (S) enantiomer to be slightly more active than the (R) isomer. Electrophysiological measurements on the American cockroach central nerve cord showed the compounds to elicite the impulses and subsequently blocked them. The neuroblocking potency of the (S) isomer was 5.9 microM, while that of the (R) isomer was as high as 73 microM. The molar concentrations required for 50% inhibition of the specific binding of [3H]imidacloprid to the housefly head membrane preparation were respectively 0.19 microM and 0.95 microM for the (S) and (R) isomers. This enatioselectivity ratio was smaller than 35 for nicotine isomers but greater than 2 for epibatidine isomers.


Assuntos
Baratas/fisiologia , Moscas Domésticas/fisiologia , Imidazóis/química , Imidazóis/farmacologia , Imidazolidinas , Inseticidas/química , Inseticidas/farmacologia , Sistema Nervoso/efeitos dos fármacos , Piridinas/química , Piridinas/farmacologia , Animais , Sítios de Ligação , Cristalografia por Raios X , Imidazóis/síntese química , Indicadores e Reagentes , Inseticidas/síntese química , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Conformação Molecular , Neonicotinoides , Neurônios/efeitos dos fármacos , Nitrocompostos , Plantas , Piridinas/síntese química , Receptores Colinérgicos/efeitos dos fármacos
20.
Radiat Med ; 21(3): 135-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12868862

RESUMO

A case of embryonal rhabdomyosarcoma (RMS) arising from an axillary space is described. RMS is one of the most common soft-tissue neoplasms in children, but adult embryonal RMS is rare. The patient was a 55-year-old man with a tumor of the left axillary area. RMS arising from an axillary area is also uncommon. The histological diagnosis was embryonal RMS. He received irradiation combined with chemotherapy (VAC: VCR, act-D, CPA) for the primary and metastatic lesions, obtained complete remission, and has remained disease-free for over four years as of this report.


Assuntos
Axila , Rabdomiossarcoma Embrionário , Neoplasias de Tecidos Moles , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Terapia Combinada , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Rabdomiossarcoma Embrionário/epidemiologia , Rabdomiossarcoma Embrionário/terapia , Neoplasias de Tecidos Moles/epidemiologia , Neoplasias de Tecidos Moles/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA