Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38700592

RESUMO

PURPOSE: To investigate the possibility of distinguishing between IgG4-related ophthalmic disease (IgG4-ROD) and orbital MALT lymphoma using artificial intelligence (AI) and hematoxylin-eosin (HE) images. METHODS: After identifying a total of 127 patients from whom we were able to procure tissue blocks with IgG4-ROD and orbital MALT lymphoma, we performed histological and molecular genetic analyses, such as gene rearrangement. Subsequently, pathological HE images were collected from these patients followed by the cutting out of 10 different image patches from the HE image of each patient. A total of 970 image patches from the 97 patients were used to construct nine different models of deep learning, and the 300 image patches from the remaining 30 patients were used to evaluate the diagnostic performance of the models. Area under the curve (AUC) and accuracy (ACC) were used for the performance evaluation of the deep learning models. In addition, four ophthalmologists performed the binary classification between IgG4-ROD and orbital MALT lymphoma. RESULTS: EVA, which is a vision-centric foundation model to explore the limits of visual representation, was the best deep learning model among the nine models. The results of EVA were ACC = 73.3% and AUC = 0.807. The ACC of the four ophthalmologists ranged from 40 to 60%. CONCLUSIONS: It was possible to construct an AI software based on deep learning that was able to distinguish between IgG4-ROD and orbital MALT. This AI model may be useful as an initial screening tool to direct further ancillary investigations.

3.
Front Oncol ; 14: 1277749, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322414

RESUMO

Purpose: To examine the molecular biological differences between conjunctival mucosa-associated lymphoid tissue (MALT) lymphoma and orbital MALT lymphoma in ocular adnexa lymphoma. Methods: Observational case series. A total of 129 consecutive, randomized cases of ocular adnexa MALT lymphoma diagnosed histopathologically between 2008 and 2020.Total RNA was extracted from formalin-fixed paraffin-embedded tissue from ocular adnexa MALT lymphoma, and RNA-sequencing was performed. Orbital MALT lymphoma gene expression was compared with that of conjunctival MALT lymphoma. Gene set (GS) analysis detecting for gene set cluster was performed in RNA-sequence. Related proteins were further examined by immunohistochemical staining. In addition, artificial segmentation image used to count stromal area in HE images. Results: GS analysis showed differences in expression in 29 GS types in primary orbital MALT lymphoma (N=5,5, FDR q-value <0.25). The GS with the greatest difference in expression was the GS of epithelial-mesenchymal transition (EMT). Based on this GS change, immunohistochemical staining was added using E-cadherin as an epithelial marker and vimentin as a mesenchymal marker for EMT. There was significant staining of vimentin in orbital lymphoma (P<0.01, N=129) and of E-cadherin in conjunctival lesions (P=0.023, N=129). Vimentin staining correlated with Ann Arbor staging (1 versus >1) independent of age and sex on multivariate analysis (P=0.004). Stroma area in tumor were significant difference(P<0.01). Conclusion: GS changes including EMT and stromal area in tumor were used to demonstrate the molecular biological differences between conjunctival MALT lymphoma and orbital MALT lymphoma in ocular adnexa lymphomas.

4.
Acad Radiol ; 31(3): 822-829, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37914626

RESUMO

RATIONALE AND OBJECTIVES: Pericardial fat (PF)-the thoracic visceral fat surrounding the heart-promotes the development of coronary artery disease by inducing inflammation of the coronary arteries. To evaluate PF, we generated pericardial fat count images (PFCIs) from chest radiographs (CXRs) using a dedicated deep-learning model. MATERIALS AND METHODS: We reviewed data of 269 consecutive patients who underwent coronary computed tomography (CT). We excluded patients with metal implants, pleural effusion, history of thoracic surgery, or malignancy. Thus, the data of 191 patients were used. We generated PFCIs from the projection of three-dimensional CT images, wherein fat accumulation was represented by a high pixel value. Three different deep-learning models, including CycleGAN were combined in the proposed method to generate PFCIs from CXRs. A single CycleGAN-based model was used to generate PFCIs from CXRs for comparison with the proposed method. To evaluate the image quality of the generated PFCIs, structural similarity index measure (SSIM), mean squared error (MSE), and mean absolute error (MAE) of (i) the PFCI generated using the proposed method and (ii) the PFCI generated using the single model were compared. RESULTS: The mean SSIM, MSE, and MAE were 8.56 × 10-1, 1.28 × 10-2, and 3.57 × 10-2, respectively, for the proposed model, and 7.62 × 10-1, 1.98 × 10-2, and 5.04 × 10-2, respectively, for the single CycleGAN-based model. CONCLUSION: PFCIs generated from CXRs with the proposed model showed better performance than those generated with the single model. The evaluation of PF without CT may be possible using the proposed method.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37882835

RESUMO

OBJECTIVES: To build preoperative prediction models with and without MRI for regional lymph node metastasis (r-LNM, pelvic and/or para-aortic LNM (PENM/PANM)) and for PANM in endometrial cancer using established risk factors. METHODS: In this retrospective two-center study, 364 patients with endometrial cancer were included: 253 in the model development and 111 in the external validation. For r-LNM and PANM, respectively, best subset regression with ten-time fivefold cross validation was conducted using ten established risk factors (4 clinical and 6 imaging factors). Models with the top 10 percentile of area under the curve (AUC) and with the fewest variables in the model development were subjected to the external validation (11 and 4 candidates, respectively, for r-LNM and PANM). Then, the models with the highest AUC were selected as the final models. Models without MRI findings were developed similarly, assuming the cases where MRI was not available. RESULTS: The final r-LNM model consisted of pelvic lymph node (PEN) ≥ 6 mm, deep myometrial invasion (DMI) on MRI, CA125, para-aortic lymph node (PAN) ≥ 6 mm, and biopsy; PANM model consisted of DMI, PAN, PEN, and CA125 (in order of correlation coefficient ß values). The AUCs were 0.85 (95%CI: 0.77-0.92) and 0.86 (0.75-0.94) for the external validation, respectively. The model without MRI for r-LNM and PANM showed AUC of 0.79 (0.68-0.89) and 0.87 (0.76-0.96), respectively. CONCLUSIONS: The prediction models created by best subset regression with cross validation showed high diagnostic performance for predicting LNM in endometrial cancer, which may avoid unnecessary lymphadenectomies. CLINICAL RELEVANCE STATEMENT: The prediction risks of lymph node metastasis (LNM) and para-aortic LNM can be easily obtained for all patients with endometrial cancer by inputting the conventional clinical information into our models. They help in the decision-making for optimal lymphadenectomy and personalized treatment. KEY POINTS: •Diagnostic performance of lymph node metastases (LNM) in endometrial cancer is low based on size criteria and can be improved by combining with other clinical information. •The optimized logistic regression model for regional LNM consists of lymph node ≥ 6 mm, deep myometrial invasion, cancer antigen-125, and biopsy, showing high diagnostic performance. •Our model predicts the preoperative risk of LNM, which may avoid unnecessary lymphadenectomies.

6.
Curr Eye Res ; 48(12): 1195-1202, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37566457

RESUMO

PURPOSE: The purpose of this study was to develop artificial intelligence algorithms that can distinguish between orbital and conjunctival mucosa-associated lymphoid tissue (MALT) lymphomas in pathological images. METHODS: Tissue blocks with residual MALT lymphoma and data from histological and flow cytometric studies and molecular genetic analyses such as gene rearrangement were procured for 129 patients treated between April 2008 and April 2020. We collected pathological hematoxylin and eosin-stained (HE) images of lymphoma from these patients and cropped 10 different image patches at a resolution of 2048 × 2048 from pathological images from each patient. A total of 990 images from 99 patients were used to create and evaluate machine-learning models. Each image patch of three different magnification rates at ×4, ×20, and ×40 underwent texture analysis to extract features, and then seven different machine-learning algorithms were applied to the results to create models. Cross-validation on a patient-by-patient basis was used to create and evaluate models, and then 300 images from the remaining 30 cases were used to evaluate the average accuracy rate. RESULTS: Ten-fold cross-validation using the support vector machine with linear kernel algorithm was identified as the best algorithm for discriminating between conjunctival mucosa-associated lymphoid tissue and orbital MALT lymphomas, with an average accuracy rate under cross-validation of 85%. There were ×20 magnification HE images that were more accurate in distinguishing orbital and conjunctival MALT lymphomas among ×4, ×20, and ×40. CONCLUSION: Artificial intelligence algorithms can successfully distinguish HE images between orbital and conjunctival MALT lymphomas.


Assuntos
Neoplasias da Túnica Conjuntiva , Neoplasias Oculares , Linfoma de Zona Marginal Tipo Células B , Humanos , Linfoma de Zona Marginal Tipo Células B/genética , Inteligência Artificial , Neoplasias da Túnica Conjuntiva/diagnóstico , Neoplasias da Túnica Conjuntiva/patologia , Aprendizado de Máquina
7.
Cancers (Basel) ; 15(5)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36900325

RESUMO

We aimed to develop and evaluate an automatic prediction system for grading histopathological images of prostate cancer. A total of 10,616 whole slide images (WSIs) of prostate tissue were used in this study. The WSIs from one institution (5160 WSIs) were used as the development set, while those from the other institution (5456 WSIs) were used as the unseen test set. Label distribution learning (LDL) was used to address a difference in label characteristics between the development and test sets. A combination of EfficientNet (a deep learning model) and LDL was utilized to develop an automatic prediction system. Quadratic weighted kappa (QWK) and accuracy in the test set were used as the evaluation metrics. The QWK and accuracy were compared between systems with and without LDL to evaluate the usefulness of LDL in system development. The QWK and accuracy were 0.364 and 0.407 in the systems with LDL and 0.240 and 0.247 in those without LDL, respectively. Thus, LDL improved the diagnostic performance of the automatic prediction system for the grading of histopathological images for cancer. By handling the difference in label characteristics using LDL, the diagnostic performance of the automatic prediction system could be improved for prostate cancer grading.

8.
Sci Rep ; 13(1): 628, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36635425

RESUMO

This study aimed to develop a versatile automatic segmentation model of bladder cancer (BC) on MRI using a convolutional neural network and investigate the robustness of radiomics features automatically extracted from apparent diffusion coefficient (ADC) maps. This two-center retrospective study used multi-vendor MR units and included 170 patients with BC, of whom 140 were assigned to training datasets for the modified U-net model with five-fold cross-validation and 30 to test datasets for assessment of segmentation performance and reproducibility of automatically extracted radiomics features. For model input data, diffusion-weighted images with b = 0 and 1000 s/mm2, ADC maps, and multi-sequence images (b0-b1000-ADC maps) were used. Segmentation accuracy was compared between ours and existing models. The reproducibility of radiomics features on ADC maps was evaluated using intraclass correlation coefficient. The model with multi-sequence images achieved the highest Dice similarity coefficient (DSC) with five-fold cross-validation (mean DSC = 0.83 and 0.79 for the training and validation datasets, respectively). The median (interquartile range) DSC of the test dataset model was 0.81 (0.70-0.88). Radiomics features extracted from manually and automatically segmented BC exhibited good reproducibility. Thus, our U-net model performed highly accurate segmentation of BC, and radiomics features extracted from the automatic segmentation results exhibited high reproducibility.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Bexiga Urinária , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
11.
Eur Radiol ; 32(11): 7976-7987, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35394186

RESUMO

OBJECTIVES: To develop and evaluate a deep learning-based algorithm (DLA) for automatic detection of bone metastases on CT. METHODS: This retrospective study included CT scans acquired at a single institution between 2009 and 2019. Positive scans with bone metastases and negative scans without bone metastasis were collected to train the DLA. Another 50 positive and 50 negative scans were collected separately from the training dataset and were divided into validation and test datasets at a 2:3 ratio. The clinical efficacy of the DLA was evaluated in an observer study with board-certified radiologists. Jackknife alternative free-response receiver operating characteristic analysis was used to evaluate observer performance. RESULTS: A total of 269 positive scans including 1375 bone metastases and 463 negative scans were collected for the training dataset. The number of lesions identified in the validation and test datasets was 49 and 75, respectively. The DLA achieved a sensitivity of 89.8% (44 of 49) with 0.775 false positives per case for the validation dataset and 82.7% (62 of 75) with 0.617 false positives per case for the test dataset. With the DLA, the overall performance of nine radiologists with reference to the weighted alternative free-response receiver operating characteristic figure of merit improved from 0.746 to 0.899 (p < .001). Furthermore, the mean interpretation time per case decreased from 168 to 85 s (p = .004). CONCLUSION: With the aid of the algorithm, the overall performance of radiologists in bone metastases detection improved, and the interpretation time decreased at the same time. KEY POINTS: • A deep learning-based algorithm for automatic detection of bone metastases on CT was developed. • In the observer study, overall performance of radiologists in bone metastases detection improved significantly with the aid of the algorithm. • Radiologists' interpretation time decreased at the same time.


Assuntos
Neoplasias Ósseas , Aprendizado Profundo , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Algoritmos , Tomografia Computadorizada por Raios X , Radiologistas , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário
12.
Magn Reson Imaging ; 85: 161-167, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34687853

RESUMO

PURPOSE: To evaluate radiomic machine learning (ML) classifiers based on multiparametric magnetic resonance images (MRI) in pretreatment assessment of endometrial cancer (EC) risk factors and to examine effects on radiologists' interpretation of deep myometrial invasion (dMI). METHODS: This retrospective study examined 200 consecutive patients with EC during January 2004 -March 2017, divided randomly to Discovery (n = 150) and Test (n = 50) datasets. Radiomic features of tumors were extracted from T2-weighted images, apparent diffusion coefficient map, and contrast enhanced T1-weighed images. Using the Discovery dataset, feature selection and hyperparameter tuning for XGBoost were performed. Ten classifiers were built to predict dMI, histological grade, lymphovascular invasion (LVI), and pelvic/paraaortic lymph node metastasis (PLNM/PALNM), respectively. Using the Test dataset, the diagnostic performances of ten classifiers were assessed by the area under the receiver operator characteristic curve (AUC). Next, four radiologists assessed dMI independently using MRI with a Likert scale before and after referring to inference of the ML classifier for the Test dataset. Then, AUCs obtained before and after reference were compared. RESULTS: In the Test dataset, mean AUC of ML classifiers for dMI, histological grade, LVI, PLNM, and PALNM were 0.83, 0.77, 0.81, 0.72, and 0.82. AUCs of all radiologists for dMI (0.83-0.88) were better than or equal to mean AUC of the ML classifier, which showed no statistically significant difference before and after the reference. CONCLUSION: Radiomic classifiers showed promise for pretreatment assessment of EC risk factors. Radiologists' inferences outperformed the ML classifier for dMI and showed no improvement by review.


Assuntos
Neoplasias do Endométrio , Aprendizado de Máquina , Neoplasias do Endométrio/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Prognóstico , Radiologistas , Estudos Retrospectivos , Fatores de Risco
13.
Sci Rep ; 11(1): 18422, 2021 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-34531429

RESUMO

To determine whether temporal subtraction (TS) CT obtained with non-rigid image registration improves detection of various bone metastases during serial clinical follow-up examinations by numerous radiologists. Six board-certified radiologists retrospectively scrutinized CT images for patients with history of malignancy sequentially. These radiologists selected 50 positive and 50 negative subjects with and without bone metastases, respectively. Furthermore, for each subject, they selected a pair of previous and current CT images satisfying predefined criteria by consensus. Previous images were non-rigidly transformed to match current images and subtracted from current images to automatically generate TS images. Subsequently, 18 radiologists independently interpreted the 100 CT image pairs to identify bone metastases, both without and with TS images, with each interpretation separated from the other by an interval of at least 30 days. Jackknife free-response receiver operating characteristics (JAFROC) analysis was conducted to assess observer performance. Compared with interpretation without TS images, interpretation with TS images was associated with a significantly higher mean figure of merit (0.710 vs. 0.658; JAFROC analysis, P = 0.0027). Mean sensitivity at lesion-based was significantly higher for interpretation with TS compared with that without TS (46.1% vs. 33.9%; P = 0.003). Mean false positive count per subject was also significantly higher for interpretation with TS than for that without TS (0.28 vs. 0.15; P < 0.001). At the subject-based, mean sensitivity was significantly higher for interpretation with TS images than that without TS images (73.2% vs. 65.4%; P = 0.003). There was no significant difference in mean specificity (0.93 vs. 0.95; P = 0.083). TS significantly improved overall performance in the detection of various bone metastases.


Assuntos
Neoplasias Ósseas/tratamento farmacológico , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiologistas/estatística & dados numéricos , Sensibilidade e Especificidade , Software , Tomografia Computadorizada por Raios X/métodos
14.
Front Artif Intell ; 4: 694815, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34337394

RESUMO

Purpose: The purpose of this study was to develop and evaluate lung cancer segmentation with a pretrained model and transfer learning. The pretrained model was constructed from an artificial dataset generated using a generative adversarial network (GAN). Materials and Methods: Three public datasets containing images of lung nodules/lung cancers were used: LUNA16 dataset, Decathlon lung dataset, and NSCLC radiogenomics. The LUNA16 dataset was used to generate an artificial dataset for lung cancer segmentation with the help of the GAN and 3D graph cut. Pretrained models were then constructed from the artificial dataset. Subsequently, the main segmentation model was constructed from the pretrained models and the Decathlon lung dataset. Finally, the NSCLC radiogenomics dataset was used to evaluate the main segmentation model. The Dice similarity coefficient (DSC) was used as a metric to evaluate the segmentation performance. Results: The mean DSC for the NSCLC radiogenomics dataset improved overall when using the pretrained models. At maximum, the mean DSC was 0.09 higher with the pretrained model than that without it. Conclusion: The proposed method comprising an artificial dataset and a pretrained model can improve lung cancer segmentation as confirmed in terms of the DSC metric. Moreover, the construction of the artificial dataset for the segmentation using the GAN and 3D graph cut was found to be feasible.

15.
Sci Rep ; 11(1): 14440, 2021 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-34262088

RESUMO

Endometrial cancer (EC) is the most common gynecological tumor in developed countries, and preoperative risk stratification is essential for personalized medicine. There have been several radiomics studies for noninvasive risk stratification of EC using MRI. Although tumor segmentation is usually necessary for these studies, manual segmentation is not only labor-intensive but may also be subjective. Therefore, our study aimed to perform the automatic segmentation of EC on MRI with a convolutional neural network. The effect of the input image sequence and batch size on the segmentation performance was also investigated. Of 200 patients with EC, 180 patients were used for training the modified U-net model; 20 patients for testing the segmentation performance and the robustness of automatically extracted radiomics features. Using multi-sequence images and larger batch size was effective for improving segmentation accuracy. The mean Dice similarity coefficient, sensitivity, and positive predictive value of our model for the test set were 0.806, 0.816, and 0.834, respectively. The robustness of automatically extracted first-order and shape-based features was high (median ICC = 0.86 and 0.96, respectively). Other high-order features presented moderate-high robustness (median ICC = 0.57-0.93). Our model could automatically segment EC on MRI and extract radiomics features with high reliability.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Feminino , Humanos , Gravidez
16.
Cancers (Basel) ; 13(6)2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33801859

RESUMO

The purpose of this study was to develop a computer-aided diagnosis (CAD) system for automatic classification of histopathological images of lung tissues. Two datasets (private and public datasets) were obtained and used for developing and validating CAD. The private dataset consists of 94 histopathological images that were obtained for the following five categories: normal, emphysema, atypical adenomatous hyperplasia, lepidic pattern of adenocarcinoma, and invasive adenocarcinoma. The public dataset consists of 15,000 histopathological images that were obtained for the following three categories: lung adenocarcinoma, lung squamous cell carcinoma, and benign lung tissue. These images were automatically classified using machine learning and two types of image feature extraction: conventional texture analysis (TA) and homology-based image processing (HI). Multiscale analysis was used in the image feature extraction, after which automatic classification was performed using the image features and eight machine learning algorithms. The multicategory accuracy of our CAD system was evaluated in the two datasets. In both the public and private datasets, the CAD system with HI was better than that with TA. It was possible to build an accurate CAD system for lung tissues. HI was more useful for the CAD systems than TA.

18.
Sci Rep ; 10(1): 19388, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33168936

RESUMO

We hypothesized that, in discrimination between benign and malignant parotid gland tumors, high diagnostic accuracy could be obtained with a small amount of imbalanced data when anomaly detection (AD) was combined with deep leaning (DL) model and the L2-constrained softmax loss. The purpose of this study was to evaluate whether the proposed method was more accurate than other commonly used DL or AD methods. Magnetic resonance (MR) images of 245 parotid tumors (22.5% malignant) were retrospectively collected. We evaluated the diagnostic accuracy of the proposed method (VGG16-based DL and AD) and that of classification models using conventional DL and AD methods. A radiologist also evaluated the MR images. ROC and precision-recall (PR) analyses were performed, and the area under the curve (AUC) was calculated. In terms of diagnostic performance, the VGG16-based model with the L2-constrained softmax loss and AD (local outlier factor) outperformed conventional DL and AD methods and a radiologist (ROC-AUC = 0.86 and PR-ROC = 0.77). The proposed method could discriminate between benign and malignant parotid tumors in MR images even when only a small amount of data with imbalanced distribution is available.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Glândula Parótida/diagnóstico por imagem , Neoplasias Parotídeas/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos
19.
J Digit Imaging ; 33(6): 1543-1553, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33025166

RESUMO

Temporal subtraction (TS) technique calculates a subtraction image between a pair of registered images acquired from the same patient at different times. Previous studies have shown that TS is effective for visualizing pathological changes over time; therefore, TS should be a useful tool for radiologists. However, artifacts caused by partial volume effects degrade the quality of thick-slice subtraction images, even with accurate image registration. Here, we propose a subtraction method for reducing artifacts in thick-slice images and discuss its implementation in high-speed processing. The proposed method is based on voxel matching, which reduces artifacts by considering gaps in discretized positions of two images in subtraction calculations. There are two different features between the proposed method and conventional voxel matching: (1) the size of a searching region to reduce artifacts is determined based on discretized position gaps between images and (2) the searching region is set on both images for symmetrical subtraction. The proposed method is implemented by adopting an accelerated subtraction calculation method that exploit the nature of liner interpolation for calculating the signal value at a point among discretized positions. We quantitatively evaluated the proposed method using synthetic data and qualitatively using clinical data interpreted by radiologists. The evaluation showed that the proposed method was superior to conventional methods. Moreover, the processing speed using the proposed method was almost unchanged from that of the conventional methods. The results indicate that the proposed method can improve the quality of subtraction images acquired from thick-slice images.


Assuntos
Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Humanos , Radiologistas , Técnica de Subtração
20.
Comput Biol Med ; 126: 104032, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33045649

RESUMO

PURPOSE: To develop and evaluate a three-dimensional (3D) generative model of computed tomography (CT) images of lung nodules using a generative adversarial network (GAN). To guide the GAN, lung nodule size was used. MATERIALS AND METHODS: A public CT dataset of lung nodules was used, from where 1182 lung nodules were obtained. Our proposed GAN model used masked 3D CT images and nodule size information to generate images. To evaluate the generated CT images, two radiologists visually evaluated whether the CT images with lung nodule were true or generated, and the diagnostic ability was evaluated using receiver-operating characteristic analysis and area under the curves (AUC). Then, two models for classifying nodule size into five categories were trained, one using the true and the other using the generated CT images of lung nodules. Using true CT images, the classification accuracy of the sizes of the true lung nodules was calculated for the two classification models. RESULTS: The sensitivity, specificity, and AUC of the two radiologists were respectively as follows: radiologist 1: 81.3%, 37.7%, and 0.592; radiologist 2: 77.1%, 30.2%, and 0.597. For categorization of nodule size, the mean accuracy of the classification model constructed with true CT images was 85% (range 83.2-86.1%), and that with generated CT images was 85% (range 82.2-88.1%). CONCLUSIONS: Our results show that it was possible to generate 3D CT images of lung nodules that could be used to construct a classification model of lung nodule size without true CT images.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Humanos , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Redes Neurais de Computação , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA