Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Radiother Oncol ; 197: 110372, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38866204

RESUMO

BACKGROUND AND PURPOSE: Recommendations for regional radiotherapy (RT) of sentinel lymph node (SLN)-positive breast cancer are debated. We here report a RT quality assessment of the SENOMAC trial. MATERIALS AND METHODS: The SENOMAC trial randomized clinically node-negative breast cancer patients with 1-2 SLN macrometastases to completion axillary lymph node dissection (cALND) or SLN biopsy only between 2015-2021. Adjuvant RT followed national guidelines. RT plans for patients included in Sweden and Denmark until June 2019 were collected (N = 1176) and compared to case report forms (CRF). Dose to level I (N = 270) and the humeral head (N = 321) was analyzed in detail. RESULTS: CRF-data and RT plans agreed in 99.3 % (breast/chest wall) and in 96.6 % of patients (regional RT). Congruence for whether level I was an intended RT target was lower (78 %). In accordance with Danish national guidelines, level I was more often an intended target in the SLN biopsy only arm (N = 334/611, 55 %,) than in the cALND arm (N = 174/565, 31 %,). When an intended target, level I received prescribed dose to 100 % (IQR 98-100 %) of the volume. However, even when not an intended target, full dose was delivered to > 80 % of level I (IQR 75-90 %). The intentional inclusion of level I in the target volume more than doubled the dose received by ≥ 50 % of the humeral head. CONCLUSION: Congruence between CRF data and RT plans was excellent. Level I received a high dose coverage even when not intentionally included in the target. Including level I in target significantly increased dose to the humeral head.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/patologia , Estudos Prospectivos , Biópsia de Linfonodo Sentinela , Excisão de Linfonodo , Dosagem Radioterapêutica , Suécia , Radioterapia Adjuvante , Axila , Garantia da Qualidade dos Cuidados de Saúde , Dinamarca , Planejamento da Radioterapia Assistida por Computador/métodos , Linfonodo Sentinela/patologia , Metástase Linfática/radioterapia , Pessoa de Meia-Idade , Idoso
2.
N Engl J Med ; 390(13): 1163-1175, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38598571

RESUMO

BACKGROUND: Trials evaluating the omission of completion axillary-lymph-node dissection in patients with clinically node-negative breast cancer and sentinel-lymph-node metastases have been compromised by limited statistical power, uncertain nodal radiotherapy target volumes, and a scarcity of data on relevant clinical subgroups. METHODS: We conducted a noninferiority trial in which patients with clinically node-negative primary T1 to T3 breast cancer (tumor size, T1, ≤20 mm; T2, 21 to 50 mm; and T3, >50 mm in the largest dimension) with one or two sentinel-node macrometastases (metastasis size, >2 mm in the largest dimension) were randomly assigned in a 1:1 ratio to completion axillary-lymph-node dissection or its omission (sentinel-node biopsy only). Adjuvant treatment and radiation therapy were used in accordance with national guidelines. The primary end point was overall survival. We report here the per-protocol and modified intention-to-treat analyses of the prespecified secondary end point of recurrence-free survival. To show noninferiority of sentinel-node biopsy only, the upper boundary of the confidence interval for the hazard ratio for recurrence or death had to be below 1.44. RESULTS: Between January 2015 and December 2021, a total of 2766 patients were enrolled across five countries. The per-protocol population included 2540 patients, of whom 1335 were assigned to undergo sentinel-node biopsy only and 1205 to undergo completion axillary-lymph-node dissection (dissection group). Radiation therapy including nodal target volumes was administered to 1192 of 1326 patients (89.9%) in the sentinel-node biopsy-only group and to 1058 of 1197 (88.4%) in the dissection group. The median follow-up was 46.8 months (range, 1.5 to 94.5). Overall, 191 patients had recurrence or died. The estimated 5-year recurrence-free survival was 89.7% (95% confidence interval [CI], 87.5 to 91.9) in the sentinel-node biopsy-only group and 88.7% (95% CI, 86.3 to 91.1) in the dissection group, with a country-adjusted hazard ratio for recurrence or death of 0.89 (95% CI, 0.66 to 1.19), which was significantly (P<0.001) below the prespecified noninferiority margin. CONCLUSIONS: The omission of completion axillary-lymph-node dissection was noninferior to the more extensive surgery in patients with clinically node-negative breast cancer who had sentinel-node macrometastases, most of whom received nodal radiation therapy. (Funded by the Swedish Research Council and others; SENOMAC ClinicalTrials.gov number, NCT02240472.).


Assuntos
Neoplasias da Mama , Excisão de Linfonodo , Linfadenopatia , Biópsia de Linfonodo Sentinela , Linfonodo Sentinela , Feminino , Humanos , Axila , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Neoplasias da Mama/secundário , Neoplasias da Mama/terapia , Intervalo Livre de Doença , Excisão de Linfonodo/métodos , Linfonodos/patologia , Linfonodos/cirurgia , Linfadenopatia/patologia , Linfadenopatia/radioterapia , Linfadenopatia/cirurgia , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Terapia Combinada , Seguimentos
3.
Phys Med ; 118: 103206, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224663

RESUMO

BACKGROUND: Non-surgical management of rectal cancer relies on (chemo)radiotherapy as the definitive treatment modality. This study reports and evaluates the clinical high dose radiotherapy treatment plans delivered to patients with low resectable rectal cancer in a Danish multicenter trial. METHODS: The Danish prospective multicenter phase II Watchful Waiting 2 trial (NCT02438839) investigated definitive chemoradiation for non-surgical management of low rectal cancer. Three Danish centers participated in the trial and committed to protocol-specified treatment planning and delivery requirements. The protocol specified a dose of 50.4 Gy in 28 fractions to the elective volume (CTV-/PTV-E) and a concomitant boost of 62 Gy in 28 fractions to the primary target volume (CTV-/PTV-T). RESULTS: The trial included 108 patients, of which 106 treatment plans were available for retrospective analysis. Dose coverage planning goals for the main target structures were fulfilled for 94% of the treatment plans. However, large intercenter differences in doses to organs-at-risk (OARs) were seen, especially for the intestines. Five patients had a V60Gy>10 cm3 for the intestines and two patients for the bladder. CONCLUSION: Prescribed planning goals for target coverage were fulfilled for 94% of the treatment plans, however analysis of OAR doses and volumes indicated intercenter variations. Dose escalation to 62 Gy (as a concomitant boost to the primary tumor) introduced no substantial high dose volumes (>60 Gy) to the bladder and intestines. The treatment planning goals may be used for future prospective evaluation of highdose radiotherapy for organ preservation for low rectal cancer.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias Retais , Humanos , Preservação de Órgãos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Retais/radioterapia , Estudos Prospectivos
4.
Lancet Reg Health Eur ; 36: 100789, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38188272

RESUMO

Background: Guidelines recommend preoperative dental screening (PDS) prior to cardiac valve surgery, to reduce the incidence of prosthetic valve infective endocarditis (IE). However, limited data support these recommendations, particular in patients undergoing transcatheter aortic valve implantation (TAVI). We aimed to investigate the effect of mandatory PDS on risk of IE in patients undergoing TAVI. Methods: In this observational study, a total of 1133 patients undergoing TAVI in Western-Denmark from 2020 to 2022 were included. Patients were categorized based on two implemented PDS practices: mandatory PDS (MPDS group), and no referral for PDS (NPDS group). Outcome data were retrieved from Danish registries and confirmed using medical records. The primary outcome was incidence of IE. Secondary outcomes were all-cause mortality and composite outcome of all-cause mortality and IE. Findings: Of 568 patients in the MPDS group 126 (22.2%) underwent subsequent oral dental surgery, compared to 8 (1.4%) among 565 patients in the NPDS group. During a median follow-up of 1.9 years (interquartile range 1.4-2.5 years), 31 (2.7%) developed IE. The yearly incidence IE rate was 1.4% (0.8-2.3) and 1.5% (0.8-2.4) in MPDS and NPDS, respectively, p = 0.86. All-cause mortality rates were similar between groups (estimated 2-year overall mortality of 6.7% (4.8-9.2) vs. 4.7% (3.2-6.9), MPDS and NPDS, respectively, p = 0.15). Consistent findings were found in 712 propensity score-matched patients. Interpretation: Mandatory PDS did not demonstrate reduced risk of IE or all-cause mortality compared to targeted PDS in patients undergoing TAVI. Funding: The funder had no role in the study design, data management, or writing.

5.
Acta Oncol ; 62(10): 1161-1168, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37850659

RESUMO

BACKGROUND: Previously, many radiotherapy (RT) trials were based on a few selected dose measures. Many research questions, however, rely on access to the complete dose information. To support such access, a national RT plan database was created. The system focuses on data security, ease of use, and re-use of data. This article reports on the development and structure, and the functionality and experience of this national database. METHODS AND MATERIALS: A system based on the DICOM-RT standard, DcmCollab, was implemented with direct connections to all Danish RT centres. Data is segregated into any number of collaboration projects. User access to the system is provided through a web interface. The database has a finely defined access permission model to support legal requirements. RESULTS: Currently, data for more than 14,000 patients have been submitted to the system, and more than 50 research projects are registered. The system is used for data collection, trial quality assurance, and audit data set generation.Users reported that the process of submitting data, waiting for it to be processed, and then manually attaching it to a project was resource intensive. This was accommodated with the introduction of triggering features, eliminating much of the need for users to manage data manually. Many other features, including structure name mapping, RT plan viewer, and the Audit Tool were developed based on user input. CONCLUSION: The DcmCollab system has provided an efficient means to collect and access complete datasets for multi-centre RT research. This stands in contrast with previous methods of collecting RT data in multi-centre settings, where only singular data points were manually reported. To accommodate the evolving legal environment, DcmCollab has been defined as a 'data processor', meaning that it is a tool for other research projects to use rather than a research project in and of itself.


Assuntos
Radioterapia (Especialidade) , Radioterapia , Humanos , Ensaios Clínicos como Assunto
6.
Acta Oncol ; 62(11): 1551-1560, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37815867

RESUMO

BACKGROUND: As magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure. MATERIALS AND METHODS: Nine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated. RESULTS: We found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (σ = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels. CONCLUSION: There is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Encéfalo , Imagens de Fantasmas
7.
Phys Imaging Radiat Oncol ; 27: 100485, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37705727

RESUMO

Large Digital Imaging and Communications in Medicine (DICOM) datasets are key to support research and the development of machine learning technology in radiotherapy (RT). However, the tools for multi-centre data collection, curation and standardisation are not readily available. Automated batch DICOM export solutions were demonstrated for a multicentre setup. A Python solution, Collaborative DICOM analysis for RT (CORDIAL-RT) was developed for curation, standardisation, and analysis of the collected data. The setup was demonstrated in the DBCG RT-Nation study, where 86% (n = 7748) of treatments in the inclusion period were collected and quality assured, supporting the applicability of the end-to-end framework.

8.
Acta Oncol ; 62(10): 1279-1285, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37647364

RESUMO

BACKGROUND: Secondary lymphedema is a known side effect to radiotherapy (RT), but limited information regarding prevalence and risk factors for lower limb edema (LLE) after curative radiotherapy in patients with prostate cancer (PCa) is available. This study provides a descriptive analysis of patient-reported LLE with analysis of risk factors in a cohort of patients with PCa treated with curative RT. MATERIAL AND METHODS: A total of 302 patients with PCa with prospective registration of patient-reported LLE (EORTC QLQ-PR25 (Question 46)) were included. Analysis of LLE was done with the calculation of prevalence rates and Kaplan-Meier statistics. Risk factors for LLE were analyzed multivariate with Cox regression analysis. RESULTS: At a median follow-up of 15 (3-51) months, the overall crude incidence of patients reporting 'quite a bit' or 'a lot' of LLE was 49 (16.2%) and 21 (7.0%), respectively. The baseline prevalence rate of 'quite a bit' and 'a lot' of LLE was 5.0% and 0.8%, respectively. During follow-up the prevalence rate for 'quite a bit' or 'a lot' of LLE increased significantly and remained constant from 6 months where 11.5% (±1.7%) reported 'quite a bit' and 2.9% (±0.5%) reported 'very much' LLE (p < 0.001), respectively.Significant risk factors (p < 0.10) for LLE in univariate analysis included lymph node irradiation (HR:2.325), baseline Body Mass Index (BMI) (HR:1.100), Charlson Comorbidity Index (HR:1.227), Androgen Deprivation Therapy (HR:2,979), and Performance Status (HR:0.594). Only high BMI (HR:1.091) remained significant in multivariate analysis with a three-fold increase in LLE in patients with BMI ≥ 30 compared to normal weight patients. CONCLUSION: Severe patient-reported LLE after curative RT for PCa is rare. Significantly more patients with a high BMI report 'quite a bit' or 'very much' LLE compared to patients with a normal BMI. Obese PCa patients could be offered a rehabilitation program for early detection and management of LLE.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Estudos Prospectivos , Antagonistas de Androgênios , Edema , Extremidade Inferior , Medidas de Resultados Relatados pelo Paciente
9.
Eur J Cardiothorac Surg ; 63(2)2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617167

RESUMO

OBJECTIVES: To assess temporal changes in the surgical management of patients with tetralogy of Fallot including the timing of interventions, surgical techniques, reinterventions and survival in a nationwide cohort. METHODS: Patients with tetralogy of Fallot in Denmark were divided into 3 eras based on their year of birth: early (1977-1991), intermediate (1992-2006) and late (2007-2021). RESULTS: The cohort consisted of 745 patients. Median follow-up was 21.2 years (13.7-30.5). There was a temporal trend towards less shunt palliation (-0.3% per year, 95% CI -0.05 to -0.1). Median age at intracardiac repair was 2.9 years (1.8-5.0), 0.8 years (0.5-1.3) and 0.5 years (0.4-0.7) (P < 0.001) in the early, intermediate and late era, respectively. There was a temporal trend towards less valve-sparing repair (-0.7% per year, 95% CI -0.5 to -1.0) and more repair with transannular patches (0.7% per year, 95% CI 0.5-1.0). Survival at 10 years was 79% (64-76), 90% (87-93) and 95% (92-98) (P < 0.001) and pulmonary valve replacement within the first 10 years after intracardiac repair was performed in 3% (1-6), 12% (8-16) and 21% (13-29) (P < 0.001) in the early, intermediate and late era, respectively. CONCLUSIONS: There was a temporal trend towards less shunt palliation and intracardiac repair at a younger age with more use of transannular patches. While survival throughout childhood and adolescence has improved, more patients undergo pulmonary valve replacement during the first 10 years after intracardiac repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar , Tetralogia de Fallot , Adolescente , Humanos , Lactente , Criança , Pré-Escolar , Tetralogia de Fallot/cirurgia , Estudos de Coortes , Valva Pulmonar/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Reoperação , Dinamarca/epidemiologia , Resultado do Tratamento , Estudos Retrospectivos
10.
Radiother Oncol ; 180: 109453, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36642388

RESUMO

BACKGROUND: Coronary artery disease (CAD) has been reported as a late effect following radiation therapy (RT) of early breast cancer (BC). This study aims to report individual RT doses to the heart and cardiac substructures in patients treated with CT-based RT and to investigate if a dose-response relationship between RT dose and CAD exists using modern radiation therapy techniques. METHODS: Patients registered in the Danish Breast Cancer Group database from 2005 to 2016 with CT-based RT were eligible. Among 15,765 patients, the study included 204 with CAD after irradiation (cases) and 408 matched controls. Individual planning CTs were retrieved, the heart and cardiac substructures were delineated and dose-volume parameters were extracted. RESULTS: The median follow-up time was 7.3 years (IQR: 4.6-10.0). Among cases, the median mean heart dose was 1.6 Gy (IQR 0.2-6.1) and 0.8 Gy (0.1-2.9) for left-sided and right-sided patients, respectively (p < 0.001). The highest RT doses were observed in the left ventricle and left anterior descending coronary artery for left-sided RT and in the right atrium and the right coronary artery after right-sided RT. The highest left-minus-right dose-difference was located in the distal part of the left anterior descending coronary artery where also the highest left-versus-right ratio of events was observed. However, no significant difference in the distribution of CAD was observed by laterality. Furthermore, no significant differences in the dose-volume parameters were observed for cases versus controls. CONCLUSIONS: CAD tended to occur in the part of the heart with the highest left-minus- right dose difference, however, no significant risk of CAD was observed at 7 years' median follow-up.


Assuntos
Neoplasias da Mama , Doença da Artéria Coronariana , Humanos , Feminino , Doença da Artéria Coronariana/etiologia , Neoplasias da Mama/radioterapia , Coração/efeitos da radiação , Dosagem Radioterapêutica , Doses de Radiação
11.
Phys Imaging Radiat Oncol ; 21: 146-152, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35284662

RESUMO

Background and purpose: Diffusion-Weighted Magnetic Resonance imaging (DWI) quantifies water mobility through the Apparent Diffusion Coefficient (ADC), a promising radiotherapy response biomarker. ADC measurements depend on manual delineation of a region of interest, a time-consuming and observer-dependent process. Here, the aim was to introduce and test the performance of a new, semi-automatic delineation tool (SADT) for ADC calculation within the viable region of the tumour. Materials and methods: Thirty patients with rectal cancer were scanned with DWI before radiotherapy (RT) (baseline) and two weeks into RT (week 2). The SADT was based on intensities in b=1100 s mm-2 DWI and derived ADC maps. ADC values measured using the SADT and manual delineations were compared using Bland-Altman- and correlation analyses. Delineations were repeated to assess intra-observer variation, and repeatability was estimated using repeated DWI scans. Results: ADC measured using the SADT and manual delineation showed strong and moderate correlation at baseline and week 2, respectively, with the SADT measuring systematically smaller values. Intra-observer ADC variation was slightly smaller for the SADT compared to manual delineation both at baseline, [-0.00; 0.03] vs. [-0.02; 0.04] 10-3 mm2 s-1, and week 2, [-0.01; 0.00] vs. [-0.04; 0.07] 10-3 mm2 s-1 (68.3% limits of agreement). The ADC change between baseline and week 2 was larger than the ADC uncertainty ( ± 0.04 · 10-3 mm2 s-1) in all cases except one. Conclusion: The presented SADT showed performance comparable to manual expert delineation, and with sufficient consistency to allow extraction of potential biological information from the viable tumour.

12.
J Clin Med ; 11(2)2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35054137

RESUMO

Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.

13.
Radiother Oncol ; 164: 115-121, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34563607

RESUMO

Bolus serves as a tissue equivalent material that shifts the 95-100% isodose line towards the skin and subcutaneous tissue. The need for bolus for all breast cancer patients planned for postmastectomy radiation therapy (PMRT) has been questioned. The work was initiated by the faculty of the European SocieTy for Radiotherapy & Oncology (ESTRO) breast cancer courses and represents a multidisciplinary international breast cancer expert collaboration to optimize PMRT. Due to the lack of randomised trials evaluating the benefits of bolus, we designed a stepwise project to evaluate the existing evidence about the use of bolus in the setting of PMRT to achieve an international consensus for the indications of bolus in PMRT, based on the Delphi method.


Assuntos
Neoplasias da Mama , Mastectomia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Consenso , Técnica Delphi , Feminino , Humanos , Radioterapia Adjuvante
14.
Crit Rev Oncol Hematol ; 163: 103391, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34102286

RESUMO

PURPOSE: Post mastectomy radiation therapy (PMRT) reduces locoregional recurrence (LRR) and breast cancer mortality for selected patients. Bolus overcomes the skin-sparing effect of external-beam radiotherapy, ensuring adequate dose to superficial regions at risk of local recurrence (LR). This systematic review summarizes the current evidence regarding the impact of bolus on LR and acute toxicity in the setting of PMRT. RESULTS: 27 studies were included. The use of bolus led to higher rates of acute grade 3 radiation dermatitis (pooled rates of 9.6% with bolus vs. 1.2% without). Pooled crude LR rates from thirteen studies (n = 3756) were similar with (3.5%) and without (3.6%) bolus. CONCLUSIONS: Bolus may be indicated in cases with a high risk of LR in the skin, but seems not to be necessary for all patients. Further work is needed to define the role of bolus in PMRT.


Assuntos
Neoplasias da Mama , Radiodermite , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Radioterapia Adjuvante/efeitos adversos
15.
Clin Transl Radiat Oncol ; 27: 126-131, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33659716

RESUMO

BACKGROUND AND PURPOSE: Adjuvant radiotherapy of internal mammary nodes (IMN) improves survival in high-risk early breast cancer patients but inevitably leads to more dose to heart and lung. Target coverage is often compromised to meet heart/lung dose constraints. We estimate heart and lung dose when target coverage is not compromised in consecutive patients. These estimates are used to guide the choice of selection criteria for the randomised Danish Breast Cancer Group (DBCG) Proton Trial. MATERIALS AND METHODS: 179 breast cancer patients already treated with loco-regional IMN radiotherapy from 18 European departments were included. If the clinically delivered treatment plan did not comply with defined target coverage requirements, the plan was modified retrospectively until sufficient coverage was reached. The choice of selection criteria was based on the estimated number of eligible patients for different heart and lung dose thresholds in combination with proton therapy capacity limitations and dose-response relationships for heart and lung. RESULTS: Median mean heart dose was 3.0 Gy (range, 1.1-8.2 Gy) for left-sided and 1.4 Gy (0.4-11.5 Gy) for right-sided treatment plans. Median V17Gy/V20Gy (hypofractionated/normofractionated plans) for ipsilateral lung was 31% (9-57%). The DBCG Radiotherapy Committee chose mean heart dose ≥ 4 Gy and/or lung V17Gy/V20Gy ≥ 37% as thresholds for inclusion in the randomised trial. Using these thresholds, we estimate that 22% of patients requiring loco-regional IMN radiotherapy will be eligible for the trial. CONCLUSION: The patient selection criteria for the DBCG Proton Trial are mean heart dose ≥ 4 Gy and/or lung V17Gy/V20Gy ≥ 37%.

16.
Phys Med ; 61: 44-51, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31151578

RESUMO

Quantitative imaging features (radiomics) extracted from apparent diffusion coefficient (ADC) maps of rectal cancer patients can provide additional information to support treatment decision. Most available radiomic computational packages allow extraction of hundreds to thousands of features. However, two major factors can influence the reproducibility of radiomic features: interobserver variability, and imaging filtering applied prior to features extraction. In this exploratory study we seek to determine to what extent various commonly-used features are reproducible with regards to the mentioned factors using ADC maps from two different clinics (56 patients). Features derived from intensity distribution histograms are less sensitive to manual tumour delineation differences, noise in ADC images, pixel size resampling and intensity discretization. Shape features appear to be strongly affected by delineation quality. On the whole, textural features appear to be poorly or moderately reproducible with respect to the image pre-processing perturbations we reproduced.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Humanos , Variações Dependentes do Observador , Carga Tumoral
17.
Acta Radiol ; 60(4): 535-541, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29969051

RESUMO

BACKGROUND: Ultrasound elastography is increasingly available in clinical practice. Recent studies showed higher velocity stiffness in testicular tumors compared to normal testicles. PURPOSE: To evaluate ultrasound elastography in combination with the apparent diffusion coefficient measurements in diffusion weighted (DW) magnetic resonance imaging (MRI) in testicles. DW can be a useful tool in evaluating testicular malignancies. However, the relationship between velocity stiffness and MRI diffusion is not well established. MATERIAL AND METHODS: We prospectively included 132 patients with testicular microlithiasis (n = 53), or normal testicular tissue (n = 53), or suspected for testicular cancer (n = 26). All 132 patients underwent ultrasonography including shear wave elastography and MRI diffusion coefficient examination of the scrotum. RESULTS: No clinically relevant difference in velocity stiffness was found between normal and testicles with microlithiasis. There was a significant difference in stiffness between patients with testicular microlithiasis (0.78 m/s), normal testicular tissue (0.77 m/s), and patients with testicular cancer (1.95 m/s) ( P ≤ 0.001). Similarly, there was a statistically significant difference in MRI diffusion values between patients with testicular microlithiasis (0.978 × 10-3 mm2 s-1), normal testicular tissue (0.929 × 10-3 mm2 s-1), and testicular cancers (0.743 × 10-3 mm2 s-1) ( P < 0.01). CONCLUSION: Patients with testicular microlithiasis had no malignant characteristics measured with shear wave elastography or MRI diffusion. MRI diffusion and elastography may be useful to preoperatively differentiate benign from malignant testicular lesions.


Assuntos
Cálculos/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Técnicas de Imagem por Elasticidade/métodos , Doenças Testiculares/diagnóstico por imagem , Neoplasias Testiculares/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Testículo/diagnóstico por imagem , Adulto Jovem
18.
Catheter Cardiovasc Interv ; 92(6): 1163-1170, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30079597

RESUMO

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS: Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Técnicas de Apoio para a Decisão , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Acta Oncol ; 57(1): 113-119, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29205080

RESUMO

PURPOSE: The potential benefits from respiratory gating (RG) compared to free-breathing (FB) regarding target coverage and dose to organs at risk for breast cancer patients receiving post-operative radiotherapy (RT) in the DBCG HYPO multicentre trial are reported. MATERIAL AND METHODS: Patients included in the DBCG HYPO trial were randomized between 50 Gy in 25 fractions (normofractionated) versus 40 Gy in 15 fractions (hypofractionated). A tangential forward field-in-field dose planning technique was used to cover the clinical target volume (CTV) with the intent to limit dose to the left anterior descending coronary artery (LADCA) to 20 Gy and 17 Gy in the normo- and hypofractionated arms, respectively. Treatment plan data for 1327 patients from four Danish centres was retrospectively analyzed. FB right-sided patients served as control group for the left-sided patients regarding CTV V95% (relative volume receiving at least 95% of the prescribed dose), mean heart dose (MHD) and mean lung dose (MLD). RESULTS: Median CTV V95% was for FB right-sided, FB left-sided and RG left-sided patients 94.6, 92.6 and 94.7% for normofractionated therapy, respectively, and 94.6, 91.8 and 94.4% for hypofractionated therapy and did not differ significantly for RG left-sided plans compared to FB right-sided in either study arm. CTV V95% was significantly lower for FB versus RG for left-sided plans in both arms. Median MHD was 0.7, 1.8 and 1.5 Gy (normofractionated therapy) versus 0.6, 1.5 and 1.2 Gy (hypofractionated therapy), respectively. The corresponding median MLD was 9.0, 8.3 and 7.3 Gy versus 7.3, 6.4 and 5.8 Gy, respectively. CONCLUSIONS: RG for left-sided breast cancer patients ensured similar CTV V95% as for FB right-sided patients. MLD was lower for RG due to the increased lung volume. MHD was generally low due to strict protocol-defined maximum dose to LADCA, but for left-sided patients RG led to significantly lower MHD.


Assuntos
Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Neoplasias Unilaterais da Mama/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Vasos Coronários/diagnóstico por imagem , Fracionamento da Dose de Radiação , Feminino , Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
20.
Scand Cardiovasc J ; 51(1): 40-46, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27624406

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an established treatment for high-grade aortic valve stenosis in patients found unfit for open heart surgery. The method may cause cardiac conduction disorders requiring permanent pacemaker (PPM) implantation, and the long-term effect of PPM implantation remains ambiguous. Design One hundred sixty-eight patients who underwent TAVI from 2008 to 2012 were included. Patient characteristics, ECGs and PPM data were collected through medical records. Kaplan-Meier plots and Cox regression analysis were performed. RESULTS: Forty subjects were excluded, leaving 128 patients for final inclusion. 41 (32%) received a PPM (mean age 82 vs. 80 in patients without PPM, p = .06) within 30 days of the TAVI procedure. Median follow-up was ∼4 years and 37 (29%) died. One-year mortality was 14% for non-PPM patients vs. 2% in PPM patients, and mortality at 5yrs 70% vs. 54%, respectively. Kaplan-Meier survival analysis showed higher mortality in patients without PPM (p = .008). In multivariate survival analysis significant variables were: No PPM (HR 2.6; CI 1.1-6.2; p = .03), chronic obstructive pulmonary disease (HR 2.4; CI 1.2-5.0; p = .02) and either pre- or post-procedural chronic or paroxystic atrial fibrillation (HR 2.3; CI 1.2-4.7; p= .02). CONCLUSION: TAVI-patients with a PPM had better survival than patients in whom a PPM was not implanted.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Arritmias Cardíacas/terapia , Cateterismo Cardíaco/mortalidade , Estimulação Cardíaca Artificial/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Estimulação Cardíaca Artificial/efeitos adversos , Distribuição de Qui-Quadrado , Dinamarca , Eletrocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estimativa de Kaplan-Meier , Masculino , Prontuários Médicos , Análise Multivariada , Marca-Passo Artificial/efeitos adversos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA