Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 20(9): 098002, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26405823

RESUMO

Protoporphyrin IX (PPIX) produced following the administration of exogenous 5d-aminolevulinic acid is clinically approved for photodynamic therapy and fluorescence-guided resection in various jurisdictions around the world. For both applications, quantification of PPIX forms the basis for accurate therapeutic dose calculation and identification of malignant tissues for resection. While it is well established that the PPIX synthesis and accumulation rates are subject to the cell's biochemical microenvironment, the effect of the physical microenvironment, such as matrix stiffness, has received little attention to date. Here we studied the proliferation rate and PPIX synthesis and accumulation in two glioma cell lines U373 and U118 cultured under five different substrate conditions, including the conventional tissue culture plastic and polyacrylamide gels that simulated tissue stiffness of normal brain (1 kPa) and glioblastoma tumors (12 kPa). We found that the proliferation rate increased with substrate stiffness for both cell lines, but not in a linear fashion. PPIX concentration was significantly higher in cells cultured on tissue-simulating gels than on the much stiffer tissue culture plastic for both cell lines. These findings, albeit preliminary, suggest that the physical microenvironment might be an important determinant of tumor aggressiveness and PPIX synthesis in glioma cells.


Assuntos
Resinas Acrílicas/química , Microambiente Celular/efeitos dos fármacos , Glioblastoma/metabolismo , Glioblastoma/fisiopatologia , Protoporfirinas/metabolismo , Resinas Acrílicas/farmacologia , Contagem de Células , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Elasticidade/efeitos dos fármacos , Glioma/metabolismo , Glioma/fisiopatologia , Humanos , Fotoquimioterapia
2.
Lasers Surg Med ; 45(7): 460-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24037824

RESUMO

Effective therapies for malignant gliomas are still elusive and limited survival improvements are provided only by Temozolomide or fluorescence guided resection. The efficacy of photodynamic therapy (PDT) in this indication is limited by the higher sensitivity of normal brain structures compared to glioma necessitating a modulation of its sensitivity. We evaluate the influence of hypothermia and the tyrosine kinase inhibitor Erlotinib on cell's ability to synthesize PPIX following the administration of ALA which was not previously investigated. We demonstrate that both hypothermia and Erlotinib are favorable in PPIX selectivity as only glioma cell lines demonstrate an increased PPIX synthesis, whereas the neuronal and astrocytic synthesis is remaining unaffected. The results are encouraging to consider hypothermia and Erlotinib as adjuvant therapies to increase the PDT therapeutic index between GBM and normal intracranial tissues, as well as to improve contrast in fluorescence guided resection.


Assuntos
Glioblastoma/tratamento farmacológico , Hipotermia Induzida , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacocinética , Inibidores de Proteínas Quinases/farmacologia , Protoporfirinas/farmacocinética , Quinazolinas/farmacologia , Animais , Biomarcadores Tumorais/metabolismo , Linhagem Celular Tumoral , Citoplasma/efeitos dos fármacos , Citoplasma/metabolismo , Cloridrato de Erlotinib , Glioblastoma/metabolismo , Humanos , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Protoporfirinas/farmacologia , Protoporfirinas/uso terapêutico , Quinazolinas/uso terapêutico , Ratos , Transdução de Sinais/efeitos dos fármacos
3.
Small ; 8(11): 1780-92, 2012 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-22431228

RESUMO

Quantum dot (QD) contrast-enhanced molecular imaging has potential for early cancer detection and image guided treatment, but there is a lack of quantitative image contrast data to determine optimum QD administered doses, affecting the feasibility, risk and cost of such procedures, especially in vivo. Vascular fluorescence contrast-enhanced imaging is performed on nude mice bearing dorsal skinfold window chambers, injected with 4 different QD solutions emitting in the visible and near infrared. Linear relationships are observed among the vascular contrast, injected contrast agent volume, and QD concentration in blood. Due primarily to differential light absorption by blood, the vasculature is optimally visualized when exciting in the 435-480 nm region in 81% of the cases (89 out of 110 regions of interest in 22 window chambers). The threshold dose, defined here as the quantity of injected nanoparticles required to yield a vascular target-to-autofluorescence ratio of 2, varies from 10.6 to 0.15 pmol g(-1) depending on the QD emission wavelength. The wavelength optimization maximum and broadband gain, defined as the ratio of threshold doses estimated for optimal and suboptimal (worst wavelength or broadband) spectral illumination, has average values of 4.5 and 1.9, respectively. This study demonstrates, for the first time, optimized QD imaging in vivo. It also proposes and validates a theoretical framework for QD dose estimation and quantifies the effects of blood absorption, QD emission wavelength, and vessel diameter relative to the threshold dose.


Assuntos
Imagem Molecular/métodos , Pontos Quânticos , Animais , Feminino , Fluorescência , Humanos , Camundongos , Espectrometria de Fluorescência
4.
Med Phys ; 39(2): 765-76, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22320786

RESUMO

PURPOSE: To propose a novel technique to experimentally validate deformable dose algorithms by measuring 3D dose distributions under the condition of deformation using deformable gel dosimeters produced by a novel gel fabrication method. METHOD: Five gel dosimeters, two rigid control gels and three deformable gels, were manufactured and treated with the same conformal plan that prescribed 400 cGy to the isocenter. The control gels were treated statically; the deformable gels were treated while being compressed by an actuation device to simulate breathing motion (amplitude of compression = 1, 1.5, and 2 cm, respectively; frequency = 16 rpm). Comparison between the dose measured by the control gels and the corresponding static dose distribution calculated in the treatment planning system (TPS) has determined the intrinsic dose measurement uncertainty of the gel dosimeters. Doses accumulated using MORFEUS, a biomechanical model-based deformable registration and dose accumulation algorithm, were compared with the doses measured by the deformable gel dosimeters to verify the accuracy of MORFEUS using dose differences at each voxel as well as the gamma index test. Flexible plastic wraps were used to contain and protect the deformable gels from oxygen infiltration, which inhibits the gels' dose sensitizing ability. Since the wraps were imperfect oxygen barrier, dose comparison between MORFEUS and the deformable gels was performed only in the central region with a received dose of 200 cGy or above to exclude the peripheral region where oxygen penetration had likely affected dose measurements. RESULTS: Dose measured with the control gels showed that the intrinsic dose measurement uncertainty of the gel dosimeters was 11.8 cGy or 4.7% compared to the TPS. The absolute mean voxel-by-voxel dose difference between the accumulated dose and the dose measured with the deformable gels was 4.7 cGy (SD = 36.0 cGy) or 1.5% (SD = 13.4%) for the three deformable gels. The absolute mean vector distance between the 250, 300, 350, and 400 cGy isodose surfaces on the accumulated and measured distributions was 1.2 mm (SD < 1.5 mm). The gamma index test that used the dose measurement precision of the control gels as the dose difference criterion and 2 mm as the distance criterion was performed, and the average pass rate of the accumulated dose distributions for all three deformable gels was 92.7%. When the distance criterion was relaxed to 3 mm, the average pass rate increased to 96.9%. CONCLUSION: This study has proposed a novel technique to manufacture deformable volumetric gel dosimeters. By comparing the doses accumulated in MORFEUS and the doses measured with the dosimeters under the condition of deformation, the study has also demonstrated the potential of using deformable gel dosimetry to experimentally validate algorithms that include deformations into dose computation. Since dose less than 200 cGy was not evaluated in this study, future investigations will focus more on low dose regions by either using bigger gel dosimeters or prescribing a lower dose to provide a more complete experimental validation of MORFEUS across a wider dose range.


Assuntos
Modelos Biológicos , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Simulação por Computador , Módulo de Elasticidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Magn Reson Med ; 68(1): 152-65, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22213551

RESUMO

Evaluation of imaging for cancer detection and localization can be achieved by correlation of gold-standard histopathology with imaging data. Usage of a 3D biomechanical-based deformable registration for correlation of the histopathology of whole-tissue specimens with ex vivo imaging necessitates measurement of the distribution of biomechanical properties in the ex vivo tissue specimen and changes that occur during pathology fixation. To measure high-resolution 3D distributions of Young's modulus (E) prefixation and postfixation, a quasi-static magnetic resonance elastography method was developed at 7 T. Use of echo-planar imaging allowed for shorter imaging times, in line with limited time frames allowable for pathology specimens. The finite element modeling algorithm produced voxel-wise E measures, and mechanical indentation was used for comparison. An initial preclinical evaluation with canine prostate specimens (n = 5) demonstrated a consistent increase in E with fixation (P < 0.002) by a factor of 4 (± 1). Increases were a function of distance from the tissue edge and correlated with fixation time (ρ = 1, P < 0.02). The technique will be used to generate population-averaged data of E from clinical ex vivo specimens prefixation and postfixation to inform registration of whole-mount histopathology with in vivo imaging.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Próstata/patologia , Próstata/fisiologia , Fixação de Tecidos , Animais , Simulação por Computador , Cães , Módulo de Elasticidade/fisiologia , Análise de Elementos Finitos , Dureza/fisiologia , Testes de Dureza/métodos , Aumento da Imagem/métodos , Masculino , Modelos Biológicos , Estimulação Física/métodos , Mudanças Depois da Morte , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA