Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 48(15): 1072-1081, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36972119

RESUMO

STUDY DESIGN: Retrospective observational study. OBJECTIVE: Biomechanical and geometrical descriptors are used to improve global alignment and proportion (GAP) prediction accuracy to detect proximal junctional failure (PJF). SUMMARY OF BACKGROUND DATA: PJF is probably the most important complication after sagittal imbalance surgery. The GAP score has been introduced as an effective predictor for PJF, but it fails in certain situations. In this study, 112 patient records were gathered (57 PJF; 55 controls) with biomechanical and geometrical descriptors measured to stratify control and failure cases. PATIENTS AND METHODS: Biplanar EOS radiographs were used to build 3-dimensional full-spine models and determine spinopelvic sagittal parameters. The bending moment (BM) was calculated as the upper body mass times, the effective distance to the body center of mass at the adjacent upper instrumented vertebra +1. Other geometrical descriptors such as full balance index (FBI), spino-sacral angle (SSA), C7 plumb line/sacrofemoral distance ratio (C7/SFD ratio), T1-pelvic angle (TPA), and cervical inclination angle (CIA) were also evaluated. The respective abilities of the GAP, FBI, SSA, C7/SFD, TPA, CIA, body weight, body mass index, and BM to discriminate PJF cases were analyzed through receiver operating characteristic curves and corresponding areas under the curve (AUC). RESULTS: GAP (AUC = 0.8816) and FBI (AUC = 0.8933) were able to discriminate PJF cases but the highest discrimination power (AUC = 0.9371) was achieved with BM at upper instrumented vertebra + 1. Parameter cutoff analyses provided quantitative thresholds to characterize the control and failure groups and led to improved PJF discrimination, with GAP and BM being the most important contributors. SSA (AUC = 0.2857), C7/SFD (AUC = 0.3143), TPA (AUC = 0.5714), CIA (AUC = 0.4571), body weight (AUC = 0.6319), and body mass index (AUC = 0.7716) did not adequately predict PJF. CONCLUSION: BM reflects the quantitative biomechanical effect of external loads and can improve GAP accuracy. Sagittal alignments and mechanical integrated scores could be used to better prognosticate the risk of PJF.


Assuntos
Cifose , Fusão Vertebral , Humanos , Cifose/cirurgia , Fusão Vertebral/métodos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Pescoço , Estudos Retrospectivos , Peso Corporal
2.
Front Bioeng Biotechnol ; 9: 750246, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35087797

RESUMO

Introduction: 3D printed trussed titanium interbody cages may deliver bone stimulating mechanobiological strains to cells attached at their surface. The exact size and distribution of these strains may depend on patient-specific factors, but the influence of these factors remains unknown. Therefore, this study aimed to determine patient-specific variations in local strain patterns on the surface of a trussed titanium interbody fusion cage. Materials and Methods: Four patients eligible for spinal fusion surgery with the same cage size were selected from a larger database. For these cases, patient-specific finite element models of the lumbar spine including the same trussed titanium cage were made. Functional dynamics of the non-operated lumbar spinal segments, as well as local cage strains and caudal endplate stresses at the operated segment, were evaluated under physiological extension/flexion movement of the lumbar spine. Results: All patient-specific models revealed physiologically realistic functional dynamics of the operated spine. In all patients, approximately 30% of the total cage surface experienced strain values relevant for preserving bone homeostasis and stimulating bone formation. Mean caudal endplate contact pressures varied up to 10 MPa. Both surface strains and endplate contact pressures varied more between loading conditions than between patients. Conclusions: This study demonstrates the applicability of patient-specific finite element models to quantify the impact of patient-specific factors such as bone density, degenerative state of the spine, and spinal curvature on interbody cage loading. In the future, the same framework might be further developed in order to establish a pipeline for interbody cage design optimizations.

3.
PLoS One ; 13(8): e0200899, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30161138

RESUMO

Spinal fusion is a standard surgical treatment for patients suffering from low back pain attributed to disc degeneration. However, results are somewhat variable and unpredictable. With fusion the kinematic behaviour of the spine is altered. Fusion and/or stabilizing implants carrying considerable load and prevent rotation of the fused segments. Associated with these changes, a risk for accelerated disc degeneration at the adjacent levels to fusion has been demonstrated. However, there is yet no method to predict the effect of fusion surgery on the adjacent tissue levels, i.e. bone and disc. The aim of this study was to develop a coupled and patient-specific mechanoregulated model to predict disc generation and changes in bone density after spinal fusion and to validate the results relative to patient follow-up data. To do so, a multiscale disc mechanoregulation adaptation framework was developed and coupled with a previously developed bone remodelling algorithm. This made it possible to determine extra cellular matrix changes in the intervertebral disc and bone density changes simultaneously based on changes in loading due to fusion surgery. It was shown that for 10 cases the predicted change in bone density and degeneration grade conforms reasonable well to clinical follow-up data. This approach helps us to understand the effect of surgical intervention on the adjacent tissue remodelling. Thereby, providing the first insight for a spine surgeon as to which patient could potentially be treated successfully by spinal fusion and in which patient has a high risk for adjacent tissue changes.


Assuntos
Remodelação Óssea , Degeneração do Disco Intervertebral/cirurgia , Modelos Biológicos , Fusão Vertebral , Adaptação Fisiológica , Adulto , Algoritmos , Fenômenos Biomecânicos , Remodelação Óssea/fisiologia , Simulação por Computador , Feminino , Análise de Elementos Finitos , Seguimentos , Humanos , Imageamento Tridimensional , Disco Intervertebral/patologia , Disco Intervertebral/fisiopatologia , Disco Intervertebral/cirurgia , Degeneração do Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/fisiopatologia , Dor Lombar/patologia , Dor Lombar/fisiopatologia , Dor Lombar/cirurgia , Vértebras Lombares/patologia , Vértebras Lombares/fisiopatologia , Vértebras Lombares/cirurgia , Masculino , Medicina de Precisão , Fusão Vertebral/efeitos adversos
4.
Knee Surg Sports Traumatol Arthrosc ; 26(3): 756-761, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255659

RESUMO

PURPOSE: The role of the proximal tibiofibular joint (PTFJ) in tibial plateau fractures is unknown. The purpose of this study was to assess, with finite-element (FE) calculations, differences in interfragmentary movement (IFM) in a split fracture of lateral tibial plateau, with and without intact fibula. It was hypothesized that an intact fibula could positively contribute to the mechanical stabilization of surgically reduced lateral tibial plateau fractures. METHODS: A split fracture of the lateral tibial plateau was recreated in an FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. The fracture was reproduced using geometrical data from patient radiographs, and two models were created: one with intact fibula and other without fibula. A locking screw plate and cannulated screw systems were modelled to virtually reduce the fracture, and 80 kg static body weight was simulated. RESULTS: Under mechanical loads, the maximum interfragmentary movement achieved with the fibula was about 30% lower than without fibula, with both the cannulated screws and the locking plate. When the locking plate model was loaded, intact fibula contributed to lateromedial forces on the fractured fragments, which would be clinically translated into increased normal compression forces in the fractured plane. The intact fibula also reduced the mediolateral forces with the cannulated screws, contributing to stability of the construct. CONCLUSION: This FE model showed that an intact fibula contributes to the mechanical stability of the lateral tibial plateau. In combination with a locking plate fixation, early weight bearing may be allowed without significant IFM, contributing to an early clinical and functional recovery of the patient.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fíbula/cirurgia , Fixação Interna de Fraturas/métodos , Tíbia/lesões , Fraturas da Tíbia/cirurgia , Suporte de Carga , Fíbula/diagnóstico por imagem , Fíbula/lesões , Humanos , Imageamento Tridimensional , Radiografia , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/fisiopatologia
5.
Ann Biomed Eng ; 44(8): 2453-2463, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26715210

RESUMO

Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical µCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Simulação por Computador , Perda Auditiva Neurossensorial , Modelos Neurológicos , Feminino , Análise de Elementos Finitos , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/terapia , Humanos , Masculino , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA