Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Infect Dis ; 20(1): 320, 2020 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-32366227

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs and was selected for evaluation in South Africa in the context of HIV RDT analysis. METHODS: This study consisted of a laboratory evaluation and two-part field evaluation of the Deki Reader v100, covering two RDT testing algorithms, and an evaluation of the continuous quality monitoring through the Fionet™ web portal. Based on user feedback from the field evaluation, the device underwent hardware and software redesign, and the Deki Reader v200 was evaluated in the laboratory. Ethics approval for this evaluation was obtained from the University of the Witwatersrand Human Research Ethics Committee: M150160. RESULTS: The intra- and inter-device laboratory precision of the Deki Reader v100 were 98.3 and 99.2% respectively, and 99.3 and 100% for the Deki Reader v200. The laboratory concordances compared to standard-of-care reporting were 99.5 and 98.0% for the two respective models, while sensitivity and specificity were 99.5 and 99.4% for the Deki Reader V100 and 100 and 93.1% for the Deki Reader V200 respectively. Screening and confirmatory concordances in the field were 99.3 and 96.5% under algorithm 1 and 99.7 and 100% under algorithm 2. Sensitivity and specificity for the field evaluation were 99.8 and 97.7%. Overall robustness of the device was acceptable and continuous quality monitoring through Fionet™ was feasible. CONCLUSIONS: The Deki Reader provides an option for improved and reliable quality assessment for rapid diagnosis of HIV using RDTs to enhance the quality of healthcare at the point-of-care. However, the introduction of new RDTs and modification of current algorithms necessitates ongoing and agile RDT reader adjustments, which will require cost modelling to ensure sustainability of devices implemented into national HIV programs.


Assuntos
Sorodiagnóstico da AIDS/instrumentação , Testes Diagnósticos de Rotina/instrumentação , Ensaio de Imunoadsorção Enzimática/instrumentação , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , HIV-1/imunologia , HIV-2/imunologia , Sorodiagnóstico da AIDS/métodos , Algoritmos , Testes Diagnósticos de Rotina/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Infecções por HIV/virologia , Humanos , Programas de Rastreamento/métodos , Aplicativos Móveis , Sistemas Automatizados de Assistência Junto ao Leito , Prevalência , Sensibilidade e Especificidade , África do Sul/epidemiologia
2.
J Clin Microbiol ; 47(8): 2465-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19474266

RESUMO

The early diagnosis of human immunodeficiency virus (HIV) infection in infants is critical to ensure the initiation of treatment before significant immunological compromise. Each year an estimated 300,000 HIV-exposed infants in South Africa require access to tests for the diagnosis of HIV infection. Currently, testing is performed at several facilities by using PCR amplification of HIV DNA at 6 weeks of age by the use of dried blood spots (DBSs) and whole blood (WB). The Gen-Probe Aptima HIV type 1 (HIV-1) screening assay (the Aptima assay) is a qualitative nucleic acid test based on transcription-mediated amplification (TMA), a technology routinely used in blood banks in South Africa. The performance characteristics of Gen-Probe's TMA technology compared well to those of the Roche Amplicor HIV-1 DNA (version 1.5) assay. The sensitivity of the assay with WB and DBS samples was 100%, and the specificities were 99.4% and 99.5% for DBSs and WB, respectively. The detection of HIV by the Aptima assay at greater levels of dilution in samples negative by the comparator assay indicates an improvement in sensitivity by the use of the TMA technology. The ability to process 1,900 samples in a 24-h period on the Tigris instrument makes the Aptima assay an attractive option for high-volume, centralized laboratories.


Assuntos
Automação , Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Programas de Rastreamento/métodos , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/genética , Virologia/métodos , Sangue/virologia , Infecções por HIV/virologia , HIV-1/genética , Humanos , Lactente , Sensibilidade e Especificidade , África do Sul
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA