Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
2.
J Cardiovasc Electrophysiol ; 33(7): 1383-1390, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35502754

RESUMO

AIMS: Cryoballoon-guided pulmonary vein isolation (CB-PVI) for symptomatic atrial fibrillation (AF) has become an established treatment option with encouraging results in terms of safety and efficacy. Data reporting on long-term data beyond a follow-up (FU) period of 5 years is scarce. This prospective study aimed to evaluate very long-term outcome after CB-PVI for AF. METHODS: Data from consecutive patients treated with CB-PVI for symptomatic and drug refractory AF between 2005 and 2012 were analyzed. Patients with a FU of ≥9 years after index CB-PVI were included. All patients were continuously followed-up in our outpatient clinic. Arrhythmia recurrence was defined as AF or atrial tachycardia (AT) lasting >30 s beyond a 3-month blanking period. RESULTS: A total of 385 patients (71% male) were included. Mean age was 58 ± 10 years and paroxysmal AF was present in 93% of patients. Mean FU duration was 124 ± 24 months. At the end of the observational period, 73% of all patients were in stable sinus rhythm after a mean of 2 ± 0.8 ablation procedures. Patients with AF/AT recurrence were older (60 ± 8 vs. 57 ± 10 years; p = .019), had a higher CHA2 DS2 -Vasc Score (2.47 ± 1.46 vs. 1.98 ± 1.50; p = .01) and presented with a larger left atrium (LA)-diameter (43 ± 5.6 vs. 40 ± 5.1 mm; p = .002). The LA-diameter was also a significant predictor for AF/AT recurrence after CB-PVI (odds ratio: 0.939, 95% confidence interval: [0.886, 0.992], p = .03). CONCLUSIONS: CB-PVI as index procedure for AF ablation resulted in favorable long-term outcome in symptomatic AF. CB-PVI might be recommended as interventional therapy in patients with lower LA remodeling.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Europace ; 21(9): 1313-1324, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31199860

RESUMO

AIMS: To evaluate the effectiveness and safety of cryoballoon ablation (CBA) compared with radiofrequency ablation (RFA) for symptomatic paroxysmal or drug-refractory persistent atrial fibrillation (AF). METHODS AND RESULTS: Prospective cluster cohort study in experienced CBA and RFA centres. Primary endpoint was 'atrial arrhythmia recurrence', secondary endpoints were as follows: procedural results, safety, and clinical course. A total of 4189 patients were included: CBA 2329 (55.6%) and RFA 1860 (44.4%). Cryoballoon ablation population was younger, with fewer comorbidities. Procedure time was longer in the RFA group (P = 0.01). Radiation exposure was 2487 (CBA) and 1792 cGycm2 (RFA) (P < 0.001). Follow-up duration was 441 (CBA) and 511 days (RFA) (P < 0.0001). Primary endpoint occurred in 30.7% (CBA) and 39.4% patients (RFA) [adjusted hazard ratio (adjHR) 0.85, 95% confidence interval (CI) 0.70-1.04; P = 0.12). In paroxysmal AF, CBA resulted in a lower risk of recurrence (adjHR 0.80, 95% CI 0.64-0.99; P = 0.047). In persistent AF, the primary outcome was not different between groups. Major adverse cardiovascular and cerebrovascular event rates were 1.0% (CBA) and 2.8% (RFA) (adjHR 0.53, 95% CI 0.26-1.10; P = 0.088). Re-ablations (adjHR 0.46, 95% CI 0.34-0.61; P < 0.0001) and adverse events during follow-up (adjHR 0.64, 95% CI 0.48-0.88; P = 0.005) were less common after CBA. Higher rehospitalization rates with RFA were caused by re-ablations. CONCLUSIONS: The primary endpoint did not differ between CBA and RFA. Cryoballoon ablation was completed rapidly; the radiation exposure was greater. Rehospitalization due to re-ablations and adverse events during follow-up were observed significantly less frequently after CBA than after RFA. Subgroup analysis suggested a lower risk of recurrence after CBA in paroxysmal AF. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01360008), https://clinicaltrials.gov/ct2/show/NCT01360008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Readmissão do Paciente , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Doses de Radiação , Recidiva , Reoperação , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 4(11): 1440-1447, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30466850

RESUMO

OBJECTIVES: The CRYO4PERSISTENT AF (Cryoballoon Ablation for Early Persistent Atrial Fibrillation) trial aims to report long-term outcomes after a single pulmonary vein isolation (PVI)-only ablation procedure using the second-generation cryoballoon in persistent atrial fibrillation (PerAF) patients. BACKGROUND: Pulmonary vein isolation is recognized as the cornerstone of atrial fibrillation (AF) ablation, including ablation of PerAF. METHODS: The CRYO4PERSISTENT AF trial (NCT02213731) is a prospective, multicenter, single-arm trial designed to assess single-procedure outcomes of PVI using the cryoballoon. The primary endpoint was freedom from AF, atrial flutter, or atrial tachycardia ≥30 s after a 90-day blanking period. After enrollment, but before ablation, patients without 100% AF burden (18-h Holter monitoring or 3 consecutive electrocardiograms in a time frame ≥14 days) were excluded. Patients were followed at 3, 6, and 12 months, with 48-h Holter monitoring at 6 and 12 months. Quality of life and symptoms were evaluated at baseline and 12 months. Arrhythmia recurrence and adverse events were adjudicated by an independent committee. RESULTS: A total of 101 patients (62 ± 11 years of age, 74% men, left ventricular ejection fraction 56 ± 8%, left atrial diameter 43 ± 5 mm) meeting criteria, undergoing cryoballoon-based PVI, with follow-up data, were included. Kaplan-Meier estimate of freedom from AF, atrial flutter, or atrial tachycardia recurrence was 60.7% at 12 months. Compared with baseline, there were significantly fewer patients with arrhythmia-related symptoms at 12 months (16% vs. 92%; p < 0.0001). The symptom reduction was supported by significant improvement in 36-Item Short Form Health Survey composite scores and European Heart Rhythm Association score at 12 months. The only device related event was transient phrenic nerve injury in 2 (2%) patients, with resolution pre-discharge. CONCLUSIONS: Cryoballoon ablation for treatment of PerAF demonstrated 61% single-procedure success at 12 months post-ablation in addition to significant reduction in arrhythmia-related symptoms and improved quality of life. (Cryoballoon Ablation for Early Persistent Atrial Fibrillation [Cryo4 Persistent AF]; NCT02213731).


Assuntos
Fibrilação Atrial , Criocirurgia , Qualidade de Vida , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Criocirurgia/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Europace ; 18(3): 368-75, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26504108

RESUMO

AIMS: First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. METHODS AND RESULTS: The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural data and outcome were analysed. From 2011 to 2014, a total of 373/4184 (8.9%) patients with PAF naïve to AAD were identified. Pulmonary vein isolation (PVI) was performed with RF (n = 180) or CB (n = 193). In the RF group, patients were older (65 vs. 61 years, P < 0.01) compared with the CB group. The procedure time was significantly shorter and radiation exposure higher in the CB group. Major adverse events occurred in 1.6% (CB) and 3.7% (RF) of patients (P = 0.22). AF/atrial tachycardia (AT) recurrence until discharge was 4.5% (RF) and 8.5% (CB, P = 0.2). Follow-up (FU) ≥12 months was available in 99 (RF) and 107 (CB) patients. After 1.4 years of FU, freedom from AF/atrial tachycardia (AT) was 61% (RF) and 71% (CB, P = 0.11). In the RF group, more patients underwent cardioversion, and a trend for more repeat ablations was observed. Persistent phrenic nerve palsy was observed in one patient treated by CB. CONCLUSION: First-line ablation for PAF is safe and effective with either RF or CB. The procedure was faster with the CB, but the radiation exposure was higher. Although there was a trend for more recurrences and complications in the RF group, a more favourable risk profile in patients undergoing CB ablation might have biased the results. CLINICALTRIALSGOV IDENTIFIER: NCT01360008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Doses de Radiação , Exposição à Radiação , Recidiva , Sistema de Registros , Reoperação , Fatores de Risco , África do Sul , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA