Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 10(3)2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32143528

RESUMO

Prolonged exposure to NO2 can cause lung tissue inflammation, bronchiolitis fibrosa obliterans, and silo filler's disease. In recent years, nanostructured semiconducting metal oxides have been widely used to fabricate gas sensors because of their unique structure and surface-to-volume ratio compared to layered materials. In particular, the different morphologies of ZnO-based nanostructures significantly affect the detection property of NO2 gas sensors. However, because of the large interaction energy of chemisorption (1-10 eV), metal oxide-based gas sensors are typically operated above 100 °C, overcoming the energy limits to attain high sensitivity and fast reaction. High operating temperature negatively affects the reliability and durability of semiconductor-based sensors; at high temperature, the diffusion and sintering effects at the metal oxide grain boundaries are major factors causing undesirable long-term drift problems and preventing stability improvements. Therefore, we demonstrate NO2 gas sensors consisting of ZnO hemitubes (HTs) and nanotubes (NTs) covered with TiO2 nanoparticles (NPs). To operate the gas sensor at room temperature (RT), we measured the gas-sensing properties with ultraviolet illumination onto the active region of the gas sensor for photoactivation instead of conventional thermal activation by heating. The performance of these gas sensors was enhanced by the change of barrier potential at the ZnO/TiO2 interfaces, and their depletion layer was expanded by the NPs formation. The gas sensor based on ZnO HTs showed 1.2 times higher detection property than those consisting of ZnO NTs at the 25 ppm NO2 gas.

2.
PLoS One ; 15(1): e0227430, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31914142

RESUMO

In this study, we propose a method to quantitatively analyze the concentration of VOCs adsorbed on zeolite filters via gas chromatography (GC). The sampled VOCs from the filters with ethanol as a solution were characterized using GC to determine the concentration of the adsorbed VOCs by comparing the areas of GC peaks of the detected VOCs and ethanol. The proposed method also enabled determination of the desorption (regeneration) conditions of the zeolite filters according to heating temperature and time for various VOCs. Repeated adsorption and desorption of VOCs on zeolite filters and GC analyses allow us to evaluate the durability and reusability of the filter and could help predict the lifetime of zeolite filters in practice.


Assuntos
Filtração , Compostos Orgânicos Voláteis , Zeolitas , Adsorção , Cromatografia Gasosa , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA