Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
JCO Clin Cancer Inform ; 7: e2300026, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37843071

RESUMO

PURPOSE: Abundant literature and clinical trials indicate that routine cancer screenings decrease patient mortality for several common cancers. However, current national cancer screening guidelines heavily rely on patient age as the predominant factor in deciding cancer screening timing, neglecting other important medical characteristics of individual patients. This approach either delays screening or prescribes excessive screenings. Another disadvantage of the current approach is its inability to combine information across hospital systems because of the lack of a coherent records system. METHODS: We propose to use claims data and medical insurance transactions that use consistent and pre-established sets of codes for diagnosis, procedures, and medications to develop a clinical support tool to supply supplemental insights and precautions for physicians to make more informed decisions. Furthermore, we propose a novel machine learning framework to recommend personalized, data-driven, and dynamic screening decisions. RESULTS: We apply this new method to the study of breast cancer mammograms using claims data from 378,840 female patients to demonstrate that across different risk populations, personalized screening reduces the average delay in a cancer diagnosis by 2-3 months with statistical significance, with even stronger benefits for individual patients up to 10 months. CONCLUSION: Incorporating personal medical characteristics using claims data and novel machine learning methodologies into breast cancer screening improves screening delay by more dynamically considering changing patient risks. Future incorporation of the proposed methodology in health care settings could be provided as a potential support tool for clinicians.


Assuntos
Neoplasias da Mama , Médicos , Humanos , Feminino , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/prevenção & controle , Detecção Precoce de Câncer , Mamografia
2.
Phys Med Biol ; 63(22): 22TR02, 2018 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-30418942

RESUMO

Motion and uncertainty in radiotherapy is traditionally handled via margins. The clinical target volume (CTV) is expanded to a larger planning target volume (PTV), which is irradiated to the prescribed dose. However, the PTV concept has several limitations, especially in proton therapy. Therefore, robust and probabilistic optimization methods have been developed that directly incorporate motion and uncertainty into treatment plan optimization for intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT). Thereby, the explicit definition of a PTV becomes obsolete and treatment plan optimization is directly based on the CTV. Initial work focused on random and systematic setup errors in IMRT. Later, inter-fraction prostate motion and intra-fraction lung motion became a research focus. Over the past ten years, IMPT has emerged as a new application for robust planning methods. In proton therapy, range or setup errors may lead to dose degradation and misalignment of dose contributions from different beams - a problem that cannot generally be addressed by margins. Therefore, IMPT has led to the first implementations of robust planning methods in commercial planning systems, making these methods available for clinical use. This paper first summarizes the limitations of the PTV concept. Subsequently, robust optimization methods are introduced and their applications in IMRT and IMPT planning are reviewed.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Movimento (Física) , Dosagem Radioterapêutica
3.
J Appl Clin Med Phys ; 17(6): 44-59, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27929480

RESUMO

The purpose was to study correlations amongst IMRT DVH evaluation points and how their relaxation impacts the overall plan. 100 head-and-neck cancer cases, using the Eclipse treatment planning system with the same protocol, are statisti-cally analyzed for PTV, brainstem, and spinal cord. To measure variations amongst the plans, we use (i) interquartile range (IQR) of volume as a function of dose, (ii) interquartile range of dose as a function of volume, and (iii) dose falloff. To determine correlations for institutional and ICRU goals, conditional probabilities and medians are computed. We observe that most plans exceed the median PTV dose (average D50 = 104% prescribed dose). Furthermore, satisfying D50 reduced the probability of also satisfying D98, constituting a negative correlation of these goals. On the other hand, satisfying D50 increased the probability of satisfying D2, suggesting a positive correlation. A positive correlation is also observed between the PTV V105 and V110. Similarly, a positive correlation between the brainstem V45 and V50 is measured by an increase in the conditional median of V45, when V50 is violated. Despite the imposed institutional and international recommenda-tions, significant variations amongst DVH points can occur. Even though DVH aims are evaluated independently, sizable correlations amongst them are possible, indicating that some goals cannot be satisfied concurrently, calling for unbiased plan criteria.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem Radioterapêutica
4.
Phys Med Biol ; 55(17): 5189-202, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20714043

RESUMO

Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan. We present a spatiotemporal optimization method, which takes into account all phases of breathing via the corresponding 4D-CTs and provides a 4D-optimal plan that can be delivered throughout all breathing phases. Monte Carlo dose calculations are employed to warrant for highest dosimetric accuracy, as pertinent to study motion effects in lung. We demonstrate the performance of this optimization method with clinical lung cancer cases and compare the outcomes to conventional gating techniques. We report significant improvements in target coverage and in healthy tissue sparing at a comparable computational expense. Furthermore, we show that the phase-adapted 4D-optimized plans are robust against irregular breathing, as opposed to gating. This technique has the potential to yield a higher delivery efficiency and a decisively shorter delivery time.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Método de Monte Carlo , Movimento (Física) , Dosagem Radioterapêutica , Respiração
5.
Phys Med Biol ; 54(11): 3421-32, 2009 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-19436100

RESUMO

All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose error estimations, we do not rely on the detailed knowledge about the sources of the uncertainty and use a generic error model based on random perturbation. This generality is sought in order to cope with a large variety of error sources. We demonstrate the method on a clinical case of lung cancer and show that our method provides plans that are more robust against dosimetric errors and are clinically acceptable. In fact, the robust plan exhibits a two-fold improved equivalent uniform dose compared to the non-robust but optimized plan. The achieved speedup will allow computationally extensive multi-criteria or beam-angle optimization approaches to warrant for dosimetrically relevant plans.


Assuntos
Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Método de Monte Carlo , Dosagem Radioterapêutica , Processos Estocásticos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA