Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Blood Cancer J ; 14(1): 41, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38448432

RESUMO

Bridging therapy before CD19-directed chimeric antigen receptor (CAR) T-cell infusion is frequently applied in patients with relapsed or refractory Large B-cell lymphoma (r/r LBCL). This study aimed to assess the influence of quantified MATV and MATV-dynamics, between pre-apheresis (baseline) and pre-lymphodepleting chemotherapy (pre-LD) MATV, on CAR T-cell outcomes and toxicities in patients with r/r LBCL. MATVs were calculated semi-automatically at baseline (n = 74) and pre-LD (n = 68) in patients with r/r LBCL who received axicabtagene ciloleucel. At baseline, patients with a low MATV (< 190 cc) had a better time to progression (TTP) and overall survival (OS) compared to high MATV patients (p < 0.001). High MATV patients who remained stable or reduced upon bridging therapy showed a significant improvement in TTP (p = 0.041) and OS (p = 0.015), compared to patients with a high pre-LD MATV (> 480 cc). Furthermore, high MATV baseline was associated with severe cytokine release syndrome (CRS, p = 0.001). In conclusion, patients with low baseline MATV had the best TTP/OS and effective reduction or controlling MATV during bridging improved survival outcomes in patients with a high baseline MATV, providing rationale for the use of more aggressive bridging regimens.


Assuntos
Linfoma Difuso de Grandes Células B , Humanos , Carga Tumoral , Linfoma Difuso de Grandes Células B/terapia , Proteínas Adaptadoras de Transdução de Sinal , Antígenos CD19 , Linfócitos T
2.
Int J Radiat Oncol Biol Phys ; 118(3): 688-696, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37729971

RESUMO

PURPOSE: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) scan is the standard imaging procedure for biochemical recurrent prostate cancer postprostatectomy because of its high detection rate at low serum prostate-specific antigen levels. However, existing guidelines for clinical target volume (CTV) in prostate bed salvage external beam radiation therapy (sEBRT) are primarily based on experience-based clinical consensus and have been validated using conventional imaging modalities. Therefore, this study aimed to optimize CTV definition in sEBRT by using PSMA PET/CT-detected local recurrences (LRs). METHODS AND MATERIALS: Patients with suspected LR on PSMA PET/CT postprostatectomy were retrospectively enrolled in 9 Dutch centers. Anonymized scans were centrally reviewed by an expert nuclear medicine physician. Each boundary of the CTV guideline from the Groupe Francophone de Radiothérapie en Urologie (GFRU) was evaluated and adapted to improve the accuracy and coverage of the area at risk of LR (CTV) on PSMA PET/CT. The proposed CTV adaptation was discussed with the radiation oncologists of the participating centers, and final consensus was reached. To assess reproducibility, the participating centers were asked to delineate 3 new cases according to the new PERYTON-CTV, and the submitted contours were evaluated using the Dice similarity coefficient (DSC). RESULTS: After central review, 93 LRs were identified on 83 PSMA PET/CTs. The proposed CTV definition improved the coverage of PSMA PET/CT-detected LRs from 67% to 96% compared with the GFRU-CTV, while reducing the GFRU-CTV by 25%. The new CTV was highly reproducible, with a mean DSC of 0.82 (range, 0.81-0.83). CONCLUSIONS: This study contributes to the optimization of CTV definition in postprostatectomy sEBRT by using the pattern of LR detected on PSMA PET/CT. The PERYTON-CTV is highly reproducible across the participating centers and ensures coverage of 96% LRs while reducing the GFRU-CTV by 25%.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Próstata/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Prostatectomia/métodos , Radioisótopos de Gálio , Antígeno Prostático Específico
3.
Cancers (Basel) ; 15(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37958347

RESUMO

The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.

4.
J Hematol Oncol ; 16(1): 104, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37705050

RESUMO

Diagnosing post-transplant lymphoproliferative disorder (PTLD) is challenging and often requires invasive procedures. Analyses of cell-free DNA (cfDNA) isolated from plasma is minimally invasive and highly effective for genomic profiling of tumors. We studied the feasibility of using cfDNA to profile PTLD and explore its potential to serve as a screening tool. We included seventeen patients with monomorphic PTLD after solid organ transplantation in this multi-center observational cohort study. We used low-coverage whole genome sequencing (lcWGS) to detect copy number variations (CNVs) and targeted next-generation sequencing (NGS) to identify Epstein-Barr virus (EBV) DNA load and somatic single nucleotide variants (SNVs) in cfDNA from plasma. Seven out of seventeen (41%) patients had EBV-positive tumors, and 13/17 (76%) had stage IV disease. Nine out of seventeen (56%) patients showed CNVs in cfDNA, with more CNVs in EBV-negative cases. Recurrent gains were detected for 3q, 11q, and 18q. Recurrent losses were observed at 6q. The fraction of EBV reads in cfDNA from EBV-positive patients was 3-log higher compared to controls and EBV-negative patients. 289 SNVs were identified, with a median of 19 per sample. SNV burden correlated significantly with lactate dehydrogenase levels. Similar SNV burdens were observed in EBV-negative and EBV-positive PTLD. The most commonly mutated genes were TP53 and KMT2D (41%), followed by SPEN, TET2 (35%), and ARID1A, IGLL5, and PIM1 (29%), indicating DNA damage response, epigenetic regulation, and B-cell signaling/NFkB pathways as drivers of PTLD. Overall, CNVs were more prevalent in EBV-negative lymphoma, while no difference was observed in the number of SNVs. Our data indicated the potential of analyzing cfDNA as a tool for PTLD screening and response monitoring.


Assuntos
Ácidos Nucleicos Livres , Infecções por Vírus Epstein-Barr , Transtornos Linfoproliferativos , Humanos , Variações do Número de Cópias de DNA , Epigênese Genética , Infecções por Vírus Epstein-Barr/genética , Herpesvirus Humano 4/genética , Transtornos Linfoproliferativos/genética , Ácidos Nucleicos Livres/genética , Genômica
5.
BMC Cancer ; 23(1): 771, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596578

RESUMO

BACKGROUND: High dose unilobar radioembolization (also termed 'radiation lobectomy')-the transarterial unilobar infusion of radioactive microspheres as a means of controlling tumour growth while concomitantly inducing future liver remnant hypertrophy-has recently gained interest as induction strategy for surgical resection. Prospective studies on the safety and efficacy of the unilobar radioembolization-surgery treatment algorithm are lacking. The RALLY study aims to assess the safety and toxicity profile of holmium-166 unilobar radioembolization in patients with hepatocellular carcinoma ineligible for surgery due to insufficiency of the future liver remnant. METHODS: The RALLY study is a multicenter, interventional, non-randomized, open-label, non-comparative safety study. Patients with hepatocellular carcinoma who are considered ineligible for surgery due to insufficiency of the future liver remnant (< 2.7%/min/m2 on hepatobiliary iminodiacetic acid scan will be included. A classical 3 + 3 dose escalation model will be used, enrolling three to six patients in each cohort. The primary objective is to determine the maximum tolerated treated non-tumourous liver-absorbed dose (cohorts of 50, 60, 70 and 80 Gy). Secondary objectives are to evaluate dose-response relationships, to establish the safety and feasibility of surgical resection following unilobar radioembolization, to assess quality of life, and to generate a biobank. DISCUSSION: This will be the first clinical study to assess the unilobar radioembolization-surgery treatment algorithm and may serve as a stepping stone towards its implementation in routine clinical practice. TRIAL REGISTRATION: Netherlands Trial Register NL8902 , registered on 2020-09-15.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Microesferas , Estudos Prospectivos , Qualidade de Vida , Neoplasias Hepáticas/radioterapia , Hepatomegalia , Estudos Multicêntricos como Assunto
6.
EJNMMI Res ; 13(1): 77, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37644167

RESUMO

BACKGROUND: Early detection of recurrent or progressive HCC remains the strongest prognostic factor for survival. Dual tracer PET/CT imaging with [11C]CH and [18F]FDG can further increase detection rates as both tracers entail different metabolic pathways involved in HCC development. We investigated dual-tracer PET/CT in clinical decision making in patients suspected of recurrent or progressive HCC. All HCC patients who underwent both [11C]CH and [18F]FDG PET/CT in our institute from February 2018 to December 2021 were included. Both tracer PET/CT were within 4 weeks of each other with at least 6-month follow-up. Patients underwent dual tracer PET/CT because of unexplained and suspicious CT/MRI or sudden rise of serum tumour markers. A detected lesion was considered critical when the finding had prognostic consequences leading to treatment changes. RESULTS: Nineteen patients who underwent [11C]CH and [18F]FDG PET/CT were included of which all but six patients were previously treated for HCC. Dual-tracer critical finding detection rate was 95%, with [18F]FDG 68%, and [11C]CH 84%. Intrahepatic HCC recurrence finding rate was 65% for both tracers. [18F]FDG found more ablation site recurrences (4/5) compared to [11C]CH (2/5). Only [11C]CH found two needle tract metastases. Both tracers found 75% of the positive lymph nodes. Two new primary tumours were found, one by [18F]FDG and both by [11C]CH. CONCLUSIONS: Our study favours a dual-tracer approach in HCC staging in high-risk patients or when conventional imaging is non-conclusive.

7.
Ther Adv Med Oncol ; 15: 17588359231179311, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37441326

RESUMO

Background/objectives: Accurate and uniform interpretation and reporting of metastatic prostate cancer (PCa) lesions on prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) are indispensable. 18F-PSMA-1007 is increasingly used because of its favorable imaging characteristics. However, increased non-specific skeletal uptake may be an important pitfall of this radioligand. Therefore, we aimed to assess the interobserver variation in reporting skeletal 18F-PSMA-1007 uptake on PET/CT. Design/methods: In total, 33 18F-PSMA-1007 PET/CT scans of 21 patients with primary PCa and 12 patients with biochemical recurrence were included, and a total of 85 skeletal lesions were evaluated by three independent observers. The primary endpoint was the interobserver variability of the likelihood of malignancy of the skeletal lesions on both patient and lesion level (kappa analysis). Results: Observers qualified most lesions as not malignant (81-91%) and the overall mean interobserver agreement was moderate on both patient (κ: 0.54) and lesion level (κ: 0.55). In 52 lesions without corresponding CT substrate, the rating resulted in not malignant in 95-100%. Availability of additional imaging (60% of lesions) did not improve interobserver agreement (κ: 0.39 on lesion level) and resulted in unchanged rating for all observers in 78%. Conclusion: This interobserver analysis of skeletal 18F-PSMA-1007 uptake resulted in moderate agreement, in line with rates reported in literature. Importantly, the presence of non-specific skeletal uptake without CT substrate, as a potential shortcoming of 18F-PSMA-1007, did not impair interobserver agreement.

8.
Clin Transl Radiat Oncol ; 42: 100652, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37415639

RESUMO

Background and purpose: Previous pre-clinical research using [18F]FDG-PET has shown that whole-brain photon-based radiotherapy can affect brain glucose metabolism. This study, aimed to investigate how these findings translate into regional changes in brain [18F]FDG uptake in patients with head and neck cancer treated with intensity-modulated proton therapy (IMPT). Materials and methods: Twenty-three head and neck cancer patients treated with IMPT and available [18F]FDG scans before and at 3 months follow-up were retrospectively evaluated. Regional assessment of the [18F]FDG standardized uptake value (SUV) parameters and radiation dose in the left (L) and right (R) hippocampi, L and R occipital lobes, cerebellum, temporal lobe, L and R parietal lobes and frontal lobe were evaluated to understand the relationship between regional changes in SUV metrics and radiation dose. Results: Three months after IMPT, [18F]FDG brain uptake calculated using SUVmean and SUVmax, was significantly higher than that before IMPT. The absolute SUVmean after IMPT was significantly higher than before IMPT in seven regions of the brain (p ≤ 0.01), except for the R (p = 0.11) and L (p = 0.15) hippocampi. Absolute and relative changes were variably correlated with the regional maximum and mean doses received in most of the brain regions. Conclusion: Our findings suggest that 3 months after completion of IMPT for head and neck cancer, significant increases in the uptake of [18F]FDG (reflected by SUVmean and SUVmax) can be detected in several individual key brain regions, and when evaluated jointly, it shows a negative correlation with the mean dose. Future studies are needed to assess whether and how these results could be used for the early identification of patients at risk for adverse cognitive effects of radiation doses in non-tumor tissues.

9.
Nucl Med Commun ; 44(8): 709-718, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37132272

RESUMO

OBJECTIVES: Detection of residual oesophageal cancer after neoadjuvant chemoradiotherapy (nCRT) is important to guide treatment decisions regarding standard oesophagectomy or active surveillance. The aim was to validate previously developed 18 F-FDG PET-based radiomic models to detect residual local tumour and to repeat model development (i.e. 'model extension') in case of poor generalisability. METHODS: This was a retrospective cohort study in patients collected from a prospective multicentre study in four Dutch institutes. Patients underwent nCRT followed by oesophagectomy between 2013 and 2019. Outcome was tumour regression grade (TRG) 1 (0% tumour) versus TRG 2-3-4 (≥1% tumour). Scans were acquired according to standardised protocols. Discrimination and calibration were assessed for the published models with optimism-corrected AUCs >0.77. For model extension, the development and external validation cohorts were combined. RESULTS: Baseline characteristics of the 189 patients included [median age 66 years (interquartile range 60-71), 158/189 male (84%), 40/189 TRG 1 (21%) and 149/189 (79%) TRG 2-3-4] were comparable to the development cohort. The model including cT stage plus the feature 'sum entropy' had best discriminative performance in external validation (AUC 0.64, 95% confidence interval 0.55-0.73), with a calibration slope and intercept of 0.16 and 0.48 respectively. An extended bootstrapped LASSO model yielded an AUC of 0.65 for TRG 2-3-4 detection. CONCLUSION: The high predictive performance of the published radiomic models could not be replicated. The extended model had moderate discriminative ability. The investigated radiomic models appeared inaccurate to detect local residual oesophageal tumour and cannot be used as an adjunct tool for clinical decision-making in patients.


Assuntos
Neoplasias Esofágicas , Fluordesoxiglucose F18 , Humanos , Masculino , Idoso , Estudos Retrospectivos , Terapia Neoadjuvante/métodos , Estudos Prospectivos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Neoplasias Esofágicas/patologia , Quimiorradioterapia
10.
Eur Urol Open Sci ; 49: 23-31, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36874601

RESUMO

Background: Germline and tumour genetic testing in prostate cancer (PCa) is becoming more broadly accepted, but testing indications and clinical consequences for carriers in each disease stage are not yet well defined. Objective: To determine the consensus of a Dutch multidisciplinary expert panel on the indication and application of germline and tumour genetic testing in PCa. Design setting and participants: The panel consisted of 39 specialists involved in PCa management. We used a modified Delphi method consisting of two voting rounds and a virtual consensus meeting. Outcome measurements and statistical analysis: Consensus was reached if ≥75% of the panellists chose the same option. Appropriateness was assessed by the RAND/UCLA appropriateness method. Results and limitations: Of the multiple-choice questions, 44% reached consensus. For men without PCa having a relevant family history (familial PCa/BRCA-related hereditary cancer), follow-up by prostate-specific antigen was considered appropriate. For patients with low-risk localised PCa and a family history of PCa, active surveillance was considered appropriate, except in case of the patient being a BRCA2 germline pathogenic variant carrier. Germline and tumour genetic testing should not be done for nonmetastatic hormone-sensitive PCa in the absence of a relevant family history of cancer. Tumour genetic testing was deemed most appropriate for the identification of actionable variants, with uncertainty for germline testing. For tumour genetic testing in metastatic castration-resistant PCa, consensus was not reached for the timing and panel composition. The principal limitations are as follows: (1) a number of topics discussed lack scientific evidence, and therefore the recommendations are partly opinion based, and (2) there was a small number of experts per discipline. Conclusions: The outcomes of this Dutch consensus meeting may provide further guidance on genetic counselling and molecular testing related to PCa. Patient summary: A group of Dutch specialists discussed the use of germline and tumour genetic testing in prostate cancer (PCa) patients, indication of these tests (which patients and when), and impact of these tests on the management and treatment of PCa.

11.
Eur J Nucl Med Mol Imaging ; 50(8): 2258-2270, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36947185

RESUMO

PURPOSE: Monoclonal antibody (mAb)-based PET (immunoPET) imaging can characterise tumour lesions non-invasively. It may be a valuable tool to determine which patients may benefit from treatment with a specific monoclonal antibody (mAb) and evaluate treatment response. For 89Zr immunoPET imaging, higher sensitivity of state-of-the art PET/CT systems equipped with silicon photomultiplier (SiPM)-based detector elements may be beneficial as the low positron abundance of 89Zr causes a low signal-to-noise level. Moreover, the long physical half-life limits the amount of activity that can be administered to the patients leading to poor image quality even when using long scan durations. Here, we investigated the difference in semiquantitative performance between the PMT-based Biograph mCT, our clinical reference system, and the SiPM-based Biograph Vision PET/CT in 89Zr immunoPET imaging. Furthermore, the effects of scan duration reduction using the Vision on semiquantitative imaging parameters and its influence on image quality assessment were evaluated. METHODS: Data were acquired on day 4 post 37 MBq 89Zr-labelled mAb injection. Five patients underwent a double scan protocol on both systems. Ten patients were scanned only on the Vision. For PET image reconstruction, three protocols were used, i.e. one camera-dependent protocol and European Association of Nuclear Medicine Research Limited (EARL) standards 1 and 2 compliant protocols. Vision data were acquired in listmode and were reprocessed to obtain images at shorter scan durations. Semiquantitative PET image parameters were derived from tumour lesions and healthy tissues to assess differences between systems and scan durations. Differently reconstructed images obtained using the Vision were visually scored regarding image quality by two nuclear medicine physicians. RESULTS: When images were reconstructed using 100% acquisition time on both systems following EARL standard 1 compliant reconstruction protocols, results regarding semiquantification were comparable. For Vision data, reconstructed images that conform to EARL1 standards still resulted in comparable semiquantification at shorter scan durations (75% and 50%) regarding 100% acquisition time. CONCLUSION: Scan duration of 89Zr immunoPET imaging using the Vision can be decreased up to 50% compared with using the mCT while maintaining image quality using the EARL1 compliant reconstruction protocol.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias/diagnóstico por imagem , Padrões de Referência , Anticorpos Monoclonais , Tomografia por Emissão de Pósitrons/métodos , Processamento de Imagem Assistida por Computador
12.
Comput Struct Biotechnol J ; 21: 1102-1114, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36789266

RESUMO

In the treatment of Non-Hodgkin lymphoma (NHL), multiple therapeutic options are available. Improving outcome predictions are essential to optimize treatment. The metabolic active tumor volume (MATV) has shown to be a prognostic factor in NHL. It is usually retrieved using semi-automated thresholding methods based on standardized uptake values (SUV), calculated from 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) images. However, there is currently no consensus method for NHL. The aim of this study was to review literature on different segmentation methods used, and to evaluate selected methods by using an in house created software tool. A software tool, MUltiple SUV Threshold (MUST)-segmenter was developed where tumor locations are identified by placing seed-points on the PET images, followed by subsequent region growing. Based on a literature review, 9 SUV thresholding methods were selected and MATVs were extracted. The MUST-segmenter was utilized in a cohort of 68 patients with NHL. Differences in MATVs were assessed with paired t-tests, and correlations and distributions figures. High variability and significant differences between the MATVs based on different segmentation methods (p < 0.05) were observed in the NHL patients. Median MATVs ranged from 35 to 211 cc. No consensus for determining MATV is available based on the literature. Using the MUST-segmenter with 9 selected SUV thresholding methods, we demonstrated a large and significant variation in MATVs. Identifying the most optimal segmentation method for patients with NHL is essential to further improve predictions of toxicity, response, and treatment outcomes, which can be facilitated by the MUST-segmenter.

13.
Radiother Oncol ; 180: 109458, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36608769

RESUMO

BACKGROUND AND PURPOSE: Previously, PET image biomarkers (PET-IBMs) - the 90th percentile standardized uptake value (P90-SUV) and the Mean SUV (Mean-SUV) of the contralateral parotid gland (cPG) - were identified as predictors for late-xerostomia following head and neck cancer (HNC) radiotherapy. The aim of the current study was to assess in an independent validation cohort whether these pre-treatment PET-IBM can improve late-xerostomia prediction compared to the prediction with baseline xerostomia and mean cPG dose alone. MATERIALS AND METHODS: The prediction endpoint was patient-rated moderate-to-severe xerostomia at 12 months after radiotherapy. The PET-IBMs were extracted from pre-treatment 18 F-FDG PET images. The performance of the model (base model) with baseline xerostomia and mean cPG dose alone and models with additionally P90-SUV or Mean-SUV were tested in the current independent validation cohort. Specifically, model discrimination (area under the curve: AUC) and calibration (calibration plot) were evaluated. RESULTS: The current validation cohort consisted of 137 patients of which 40% developed moderate-to-severe xerostomia at 12 months. Both the PET-P90 model (AUC:PET-P90 = 0.71) and the PET-Mean model (AUC: PET-Mean = 0.70) performed well in the current validation cohort. Moreover, their performance were improved compared to the base model (AUC:base model= 0.68). The calibration plots showed a good fit of the prediction to the actual rates for all tested models. CONCLUSION: PET-IBMs showed an improved prediction of late-xerostomia when added to the base model in this validation cohort. This contributed to the published hypothesis that PET-IBMs include individualized information and can serve as a pre-treatment risk factor for late-xerostomia.


Assuntos
Neoplasias de Cabeça e Pescoço , Xerostomia , Humanos , Fluordesoxiglucose F18 , Xerostomia/diagnóstico por imagem , Xerostomia/etiologia , Neoplasias de Cabeça e Pescoço/radioterapia , Biomarcadores , Glândula Parótida , Tomografia por Emissão de Pósitrons
14.
Cancer Imaging ; 22(1): 69, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36527149

RESUMO

This review describes the main benefits of using long axial field of view (LAFOV) PET in clinical applications. As LAFOV PET is the latest development in PET instrumentation, many studies are ongoing that explore the potentials of these systems, which are characterized by ultra-high sensitivity. This review not only provides an overview of the published clinical applications using LAFOV PET so far, but also provides insight in clinical applications that are currently under investigation. Apart from the straightforward reduction in acquisition times or administered amount of radiotracer, LAFOV PET also allows for other clinical applications that to date were mostly limited to research, e.g., dual tracer imaging, whole body dynamic PET imaging, omission of CT in serial PET acquisition for repeat imaging, and studying molecular interactions between organ systems. It is expected that this generation of PET systems will significantly advance the field of nuclear medicine and molecular imaging.


Assuntos
Elétrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos
15.
Radiother Oncol ; 177: 164-171, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36368471

RESUMO

BACKGROUND AND PURPOSE: Xerostomia remains a common side effect of radiotherapy (RT) for patients with head and neck (H&N) cancer despite advancements in treatment planning and delivery. Secretory salivary gland cells express the prostate-specific membrane antigen (PSMA), and show significant uptake on PET scans using 68Ga/18F-PSMA-ligands. We aimed to objectively quantify the dose-response of salivary glands to RT using PSMA PET. METHODS AND MATERIALS: 28H&N cancer patients received RT with 70 Gy in 35 fractions over 7 weeks. PSMA PET/CT was acquired at baseline (BL), during treatment (DT) and at 1-&6-months post-treatment (PT1M/PT6M). Dose, BL- PT1M- and PT6M-SUV were extracted for every voxel inside each parotid (PG) and submandibular (SMG) gland. The PT1M/6M data was analysed using a generalised linear mixed effects model.Patient-reported xerostomia and DT-PSMA loss was also analysed. RESULTS: Dose had a relative effect on BL SUV. For a population average gland (BL-SUV of 10), every 1 Gy increment, decreased the PT1M/PT6M-SUV by 1.6 %/1.6 % for PGs and by 0.9 %/1.8 % for SMGs. TD50 of the population curves was 26.5/31.3 Gy for PGs, and 22.9/27.8 Gy for SMGs at PT1M /PT6M. PSMA loss correlated well with patient-reported xerostomia at DT/PT1M (Spearman's ρ = -0.64, -0.50). CONCLUSION: A strong relationship was demonstrated between radiation dose and loss of secretory cells in salivary glands derived using PSMA PET/CT. The population curve could potentially be used as a dose planning objective, by maximising the predicted post-treatment SUV. BL scans could be used to further tailor this to individual patients.


Assuntos
Neoplasias de Cabeça e Pescoço , Xerostomia , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Glândulas Salivares/diagnóstico por imagem , Xerostomia/diagnóstico por imagem , Xerostomia/etiologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/metabolismo , Tomografia por Emissão de Pósitrons
16.
EJNMMI Phys ; 9(1): 74, 2022 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-36308568

RESUMO

BACKGROUND: Excellent performance characteristics of the Vision Quadra PET/CT, e.g. a substantial increase in sensitivity, allow for precise measurements of image-derived input functions (IDIF) and tissue time activity curves. Previously we have proposed a method for a reduced 30 min (as opposed to 60 min) whole body 18F-FDG Patlak PET imaging procedure using a previously published population-averaged input function (PIF) scaled to IDIF values at 30-60 min post-injection (p.i.). The aim of the present study was to apply this method using the Vision Quadra PET/CT, including the use of a PIF to allow for shortened scan durations. METHODS: Twelve patients with suspected lung malignancy were included and received a weight-based injection of 18F-FDG. Patients underwent a 65-min dynamic PET acquisition which were reconstructed using European Association of Nuclear Medicine Research Ltd. (EARL) standards 2 reconstruction settings. A volume of interest (VOI) was placed in the ascending aorta (AA) to obtain the IDIF. An external PIF was scaled to IDIF values at 30-60, 40-60, and 50-60 min p.i., respectively, and parametric 18F-FDG influx rate constant (Ki) images were generated using a t* of 30, 40 or 50 min, respectively. Herein, tumour lesions as well as healthy tissues, i.e. liver, muscle tissue, spleen and grey matter, were segmented. RESULTS: Good agreement between the IDIF and corresponding PIF scaled to 30-60 min p.i. and 40-60 min p.i. was obtained with 7.38% deviation in Ki. Bland-Altman plots showed excellent agreement in Ki obtained using the PIF scaled to the IDIF at 30-60 min p.i. and at 40-60 min p.i. as all data points were within the limits of agreement (LOA) (- 0.004-0.002, bias: - 0.001); for the 50-60 min p.i. Ki, all except one data point fell in between the LOA (- 0.021-0.012, bias: - 0.005). CONCLUSIONS: Parametric whole body 18F-FDG Patlak Ki images can be generated non-invasively on a Vision Quadra PET/CT system. In addition, using a scaled PIF allows for a substantial (factor 2 to 3) reduction in scan time without substantial loss of accuracy (7.38% bias) and precision (image quality and noise interference).

17.
Eur J Nucl Med Mol Imaging ; 49(13): 4652-4660, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35876867

RESUMO

PURPOSE: Current European Association of Nuclear Medicine (EANM) Research Ltd. (EARL) guidelines for the standardisation of PET imaging developed for conventional systems have not yet been adjusted for long axial field-of-view (LAFOV) systems. In order to use the LAFOV Siemens Biograph Vision Quadra PET/CT (Siemens Healthineers, Knoxville, TN, USA) in multicentre research and harmonised clinical use, compliance to EARL specifications for 18F-FDG tumour imaging was explored in the current study. Additional tests at various locations throughout the LAFOV and the use of shorter scan durations were included. Furthermore, clinical data were collected to further explore and validate the effects of reducing scan duration on semi-quantitative PET image biomarker accuracy and precision when using EARL-compliant reconstruction settings. METHODS: EARL compliance phantom measurements were performed using the NEMA image quality phantom both in the centre and at various locations throughout the LAFOV. PET data (maximum ring difference (MRD) = 85) were reconstructed using various reconstruction parameters and reprocessed to obtain images at shorter scan durations. Maximum, mean and peak activity concentration recovery coefficients (RC) were obtained for each sphere and compared to EARL standards specifications. Additionally, PET data (MRD = 85) of 10 oncological patients were acquired and reconstructed using various reconstruction settings and reprocessed from 10 min listmode acquisition into shorter scan durations. Per dataset, SUVs were derived from tumour lesions and healthy tissues. ANOVA repeated measures were performed to explore differences in lesion SUVmax and SUVpeak. Wilcoxon signed-rank tests were performed to evaluate differences in background SUVpeak and SUVmean between scan durations. The coefficient of variation (COV) was calculated to characterise noise. RESULTS: Phantom measurements showed EARL compliance for all positions throughout the LAFOV for all scan durations. Regarding patient data, EARL-compliant images showed no clinically meaningful significant differences in lesion SUVmax and SUVpeak or background SUVmean and SUVpeak between scan durations. Here, COV only varied slightly. CONCLUSION: Images obtained using the Vision Quadra PET/CT comply with EARL specifications. Scan duration and/or activity administration can be reduced up to a factor tenfold without the interference of increased noise.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Imagens de Fantasmas , Biomarcadores
18.
Eur J Hybrid Imaging ; 6(1): 12, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35701566

RESUMO

BACKGROUND: In treatment of neuroendocrine neoplasms (NENs), confirmation of somatostatin receptor expression with 68Ga-DOTA somatostatin analogues is mandatory to determine eligibility for peptide receptor radionuclide therapy (PRRT). [18F]DOPA can detect additional lesions compared to [68Ga]DOTA-TOC. The aim of this study was to explore differences in tumour detection of both tracers and their relevance for selecting patients for PRRT. We retrospectively studied eight patients with NENs who underwent both [68Ga]DOTA-TOC and carbidopa-enhanced [18F]DOPA PET/CT, before first-time PRRT with [177Lu]DOTA-TATE. Tracer order was influenced due to stock availability or to detect suspected metastases with a second tracer. On CT, disease control was defined as a lesion showing complete response, partial response, or stable disease, according to RECIST 1.1. RESULTS: Seven patients with in total 89 lesions completed four infusions of 7.4 GBq [177Lu]DOTA-TATE, one patient received only two cycles. Before treatment, [18F]DOPA PET/CT detected significantly more lesions than [68Ga]DOTA-TOC PET/CT (79 vs. 62, p < .001). After treatment, no difference in number of lesions with disease control was found for [18F]DOPA-only (5/27) and [68Ga]DOTA-TOC-only lesions (4/10, p = .25). [18F]DOPA detected more liver metastases (24/27) compared to [68Ga]DOTA-TOC (7/10, p = .006). Six patients showed inpatient heterogeneity in treatment response between [18F]DOPA-only and [68Ga]DOTA-TOC-only lesions. CONCLUSIONS: Response to PRRT with [177Lu]DOTA-TATE was comparable for both [68Ga]DOTA-TOC- and [18F]DOPA-only NEN lesions. [18F]DOPA may be capable of predicting response to PRRT while finding more lesions compared to [68Ga]DOTA-TOC, although these additional lesions are often small of size and undetected by diagnostic CT.

19.
EJNMMI Res ; 12(1): 9, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35122166

RESUMO

BACKGROUND: Post-therapy [90Y] PET/CT-based dosimetry is currently recommended to validate treatment planning as [99mTc] MAA SPECT/CT is often a poor predictor of subsequent actual [90Y] absorbed dose. Treatment planning software became available allowing 3D voxel dosimetry offering tumour-absorbed dose distributions and dose-volume histograms (DVH). We aim to assess dose-response effects in post-therapy [90Y] PET/CT dosimetry in SIRT-treated HCC patients for predicting overall and progression-free survival (OS and PFS) and four-month follow-up tumour response (mRECIST). Tumour-absorbed dose and mean percentage of the tumour volume (V) receiving ≥ 100, 150, 200, or 250 Gy and mean minimum absorbed dose (D) delivered to 30%, 50%, 70%, and 90% of tumour volume were calculated from DVH's. Depending on the mean tumour -absorbed dose, treated lesions were assigned to a < 120 Gy or ≥ 120 Gy group. RESULTS: Thirty patients received 36 SIRT treatments, totalling 43 lesions. Median tumour-absorbed dose was significantly different between the ≥ 120 Gy (n = 28, 207 Gy, IQR 154-311 Gy) and < 120 Gy group (n = 15, 62 Gy, IQR 49-97 Gy, p <0 .01). Disease control (DC) was found more frequently in the ≥ 120 Gy group (79%) compared to < 120 Gy (53%). Mean tumour-absorbed dose optimal cut-off predicting DC was 131 Gy. Tumour control probability was 54% (95% CI 52-54%) for a mean tumour-absorbed dose of 120 Gy and 90% (95% CI 87-92%) for 284 Gy. Only D30 was significantly different between DC and progressive disease (p = 0.04). For the ≥ 120 Gy group, median OS and PFS were longer (median OS 33 months, [range 8-33 months] and median PFS 23 months [range 4-33 months]) than the < 120 Gy group (median OS 17 months, [range 5-33 months] and median PFS 13 months [range 1-33 months]) (p < 0.01 and p = 0.03, respectively). CONCLUSIONS: Higher 3D voxel-based tumour-absorbed dose in patients with HCC is associated with four-month DC and longer OS and PFS. DVHs in [90Y] SIRT could play a role in evaluative dosimetry.

20.
J Nucl Med ; 63(6): 899-905, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34503964

RESUMO

Immune checkpoint inhibitors (ICIs) targeting programmed cell death protein-1 (PD-1)/programmed cell death ligand-1 (PD-L1) frequently induces tumor response in metastatic melanoma patients. However, tumor response often takes months and may be heterogeneous. Consequently, additional local treatment for nonresponsive metastases may be needed, especially in the case of brain metastases. Noninvasive imaging may allow the characterization of (brain) metastases to predict response. This pilot study uses 18F-BMS986192 PET for PD-L1 expression to explore the variability in metastatic tracer uptake and its relation to tumor response, with a special focus on brain metastases. Methods: Metastatic melanoma patients underwent whole-body 18F-BMS986192 PET/CT scanning before and 6 wk after starting ICI therapy. 18F-BMS986192 uptake was measured in healthy tissues, organs, and tumor lesions. Tumor response was evaluated at 12 wk using CT of the thorax/abdomen and MRI of the brain. RECIST, version 1.1, was used to define therapy response per patient. Response per lesion was measured by the percentage change in lesion diameter. Toxicity was assessed according to Common Terminology Criteria for Adverse Events, version 4.0. Results: Baseline 18F-BMS986192 PET/CT was performed in 8 patients, with follow-up scans in 4 patients. The highest tracer uptake was observed in the spleen, bone marrow, kidneys, and liver. Tracer uptake in tumor lesions was heterogeneous. In total, 42 tumor lesions were identified at baseline, with most lesions in the lungs (n = 21) and brain (n = 14). Tracer uptake was similar between tumor locations. 18F-BMS986192 uptake in lesions at baseline, corrected for blood-pool activity, was negatively correlated with the change lesion diameter at response evaluation (r = -0.49, P = 0.005), both in intra- and extracerebral lesions. Receiver-operating-characteristic analysis demonstrated that 18F-BMS986192 uptake can discriminate between responding and nonresponding lesions with an area under the curve of 0.82. At the follow-up scan, an increased 18F-BMS986192 uptake compared with baseline scan was correlated with an increased lesion diameter at response evaluation. In the follow-up 18F-BMS986192 PET scan of 2 patients, ICI-related toxicity (thyroiditis and colitis) was detected. Conclusion: In this pilot study, 18F-BMS986192 PET showed heterogeneous uptake in intra- and extracerebral metastatic lesions in melanoma patients. Baseline 18F-BMS986192 uptake was able to predict an ICI treatment-induced reduction in lesion volume, whereas the follow-up PET scan allowed the detection of treatment-induced toxicity.


Assuntos
Neoplasias Encefálicas , Melanoma , Segunda Neoplasia Primária , Antígeno B7-H1 , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/tratamento farmacológico , Fluordesoxiglucose F18/uso terapêutico , Humanos , Inibidores de Checkpoint Imunológico , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA