Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Can J Ophthalmol ; 58(5): 455-460, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35525263

RESUMO

OBJECTIVE: We assessed the utility of apparent diffusion coefficients (ADCs) derived from diffusion-weighted imaging to differentiate benign and malignant orbital tumours by oculoplastic surgeons in the clinical setting and sought to validate observed ADC cut-off values. DESIGN AND PARTICIPANTS: Retrospective review of patients with benign or malignant biopsy-confirmed orbital tumours. METHODS: Blinded graders including 2 oculoplastic surgeons, 1 neuroradiologist, and 1 medical student located and measured orbital tumour ADCs (10-6 mm2/s) using the Region of Interest tool. OUTCOME MEASURES: Nonradiologist measurements were compared with each other to assess reliability and with an expert neuroradiologist measurement and final pathology to assess accuracy. RESULTS: Twenty-nine orbital tumours met inclusion criteria, consisting of 6 benign tumours and 23 malignant tumours. Mean ADC values for benign orbital tumours were 1430.59 ± 254.81 and 798.68 ± 309.12 mm2/s for malignant tumours. Our calculated optimized ADC cut-off to differentiate benign from malignant orbital tumours was 1120.84 × 10-6 mm2/s (sensitivity 1, specificity 0.9). Inter-rater reliability was excellent (intraclass correlation coefficient = 0.92; 95% CI, 0.86-0.96). Our 3 graders had a combined accuracy of 84.5% (92.3%, 92.3%, and 65.4%). CONCLUSIONS: Our ADC cut-off of 1120.84 × 10-6 mm2/s for benign and malignant orbital tumours agrees with previously established values in literature. Without priming with instructions, training, or access to patient characteristics, most tumours were correctly classified using rapid ADC measurements. Surgeons without radiologic expertise can use the ADC tool to quickly risk stratify orbital tumours during clinic visits to guide patient expectations and further work-up.


Assuntos
Neoplasias Orbitárias , Humanos , Neoplasias Orbitárias/diagnóstico , Neoplasias Orbitárias/patologia , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos
2.
Orbit ; 40(3): 222-227, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32460574

RESUMO

Purpose: To compare the efficacy of the vertical lid split (VLS) to the standard lateral canthotomy and cantholysis (LC/C) for orbital compartment syndrome (OCS) in the cadaveric model.Methods: Simulated OCS was achieved in seven fresh frozen cadaveric orbits. Orbital pressure (OP) was monitored in one control orbit and six interventional orbits. Initial OP was recorded before three right orbits underwent lateral canthotomy with superior and inferior cantholysis, and three left orbits underwent vertical lid split of the upper and lower eyelids. In all 7 orbits, OP was recorded for a total of 16 min. The main outcome measure was the amount of OP reduction at timed intervals.Results: Beginning OP in the control orbit was 109 mmHg, and average initial OP of the LC/C and VLS orbits were 90 and 103 mmHg, respectively. The control orbit maintained high OP without intervention. One minute after LC/C, OP decreased an average of 58.7 mmHg (65.2%; range 48-65 mmHg). One minute following VLS, OP decreased an average of 63 mmHg (61.0%; range 39-102 mmHg). At 16 min, OP reduction in the LC/C orbits averaged 65.3 mmHg (72.6%; range 56-71 mmHg), and OP reduction in the VLS orbits averaged 78 mmHg (75.5%; range 54-121 mmHg). Both interventions produced a comparable reduction in OP.Conclusions: Vertical lid split was found to be as effective as LC/C in reducing OP. The technical simplicity of the VLS lends itself well to utilization by physicians who are unfamiliar with eyelid surgery.


Assuntos
Síndromes Compartimentais , Órbita , Síndromes Compartimentais/cirurgia , Pálpebras/cirurgia , Humanos , Pressão Intraocular , Órbita/cirurgia
3.
Orbit ; 40(6): 470-480, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32990145

RESUMO

PURPOSE: The reconstruction of large (>50%) upper eyelid margin defects can be technically challenging, with multiple approaches described in the literature. We sought to review the recent literature for new techniques or modifications to existing techniques. METHODS: We conducted a Pubmed search for technique papers on the reconstruction of large upper eyelid defects published within the past ten years with a minimum of four patients. RESULTS: We identified ten articles, and divided them into techniques that use a bridging flap from the lower eyelid and those that do not. The number of upper eyelids repaired in each article ranged from 4 to 17. Most techniques could be considered either a modification of the Cutler-Beard technique or a novel anterior lamella flap laid over a graft for the posterior lamella. Postoperative complications included upper or lower eyelid cicatricial retraction, trichiasis, entropion, and lagophthalmos. CONCLUSIONS: Surgeons continue to innovate for this challenging reconstructive surgery. Overall, the trend was to use a graft, most commonly tarsoconjunctiva from the contralateral upper lid, to replace the posterior lamella, and a skin flap, from the lower eyelid or from the adjacent periorbital area, to replace the anterior lamella. Bridging techniques utilized the skin; the skin, orbicularis, and conjunctiva; or a tarsoconjunctival flap from the lower eyelid. Non-bridging techniques generally used a tarsoconjunctival or substitute graft for the posterior lamella, and a skin flap for the anterior lamella.


Assuntos
Entrópio , Doenças Palpebrais , Neoplasias Palpebrais , Procedimentos de Cirurgia Plástica , Doenças Palpebrais/cirurgia , Neoplasias Palpebrais/cirurgia , Pálpebras/cirurgia , Humanos , Transplante de Pele , Retalhos Cirúrgicos
4.
Ophthalmic Plast Reconstr Surg ; 36(1): 34-37, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31567912

RESUMO

PURPOSE: To assess the recurrence rate of involutional entropion in patients treated with a combined approach including a modified Bick procedure, excision of preseptal orbicularis muscle, and conservative resection of prolapsed orbital fat. METHODS: A retrospective chart review of patients undergoing repair of involutional entropion with the combined procedure including orbital fat resection and a second group with standard entropion repair without orbital fat resection was performed. Only patients with follow-up greater than 6 months were included in the study. RESULTS: Seventy eyelids of 54 patients met all inclusion criteria for the combined procedure group over a 9-year period from 2008 to 2016. Average follow-up was 46.9 months. There was a documented recurrence of entropion in 1 eyelid during the follow-up period (1.4%). The remaining 69 cases had successful subjective and objective results without need for any additional procedures. In the group undergoing entropion repair without fat resection, 22 eyelids of 19 patients had the required follow-up period with a recurrence rate of 4.5% (p > 0.05). CONCLUSIONS: The authors demonstrate good surgical success with a combined approach of a modified Bick procedure, preseptal orbicularis excision, and conservative orbital fat resection. Conservative fat resection during entropion repair was found to be safe, and the combined procedure was found to be effective with a rate of recurrent entropion of 1.4% on extended follow-up.The authors propose that orbital fat prolapse contributes to the mechanics of involutional entropion and that conservative orbital fat resection during surgical repair of entropion can be done safely, resulting in low recurrence rates.


Assuntos
Blefaroplastia , Entrópio , Entrópio/cirurgia , Seguimentos , Humanos , Prolapso , Recidiva , Estudos Retrospectivos
5.
Am J Otolaryngol ; 40(4): 564-566, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31109804

RESUMO

PURPOSE: The safety profile of the transcutaneous medial canthal incision for access to the medial orbit is assessed with a focus on the risk of post-operative iatrogenic epiphora. METHODS: A retrospective chart review of patients undergoing medial orbitotomy via the transcutaneous medial canthal incision was performed. Patients with a minimum of 3 months of follow-up were included and post-operative complications were assessed and characterized. RESULTS: One-hundred-fifty patients were included in the study. A total of 4 complications were identified, including one each of the following: nasolacrimal duct obstruction, hypertrophic scar, suture granuloma and soft tissue infection. Only the nasolacrimal duct obstruction required surgical intervention. DISCUSSION: Access to the medial orbit has been achieved through a variety of approaches, each with their own benefits and risk profile. The transcaruncular approach has increased in usage as a means to avoid a visible cutaneous scar and decrease the risk of iatrogenic epiphora, however, there are specific patients who may have relative contraindications to this approach. The current study demonstrates the low risk profile of the transcutaneous medial canthal incision, specifically the minimal risk of iatrogenic damage to the nasolacrimal outflow system. This approach is another useful tool which orbit surgeons should be familiar with to offer as an option to patients requiring medial orbitotomy.


Assuntos
Doença Iatrogênica/prevenção & controle , Doenças do Aparelho Lacrimal/prevenção & controle , Aparelho Lacrimal/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Órbita/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Risco , Adulto Jovem
6.
Am J Otolaryngol ; 40(4): 509-511, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30987775

RESUMO

PURPOSE: To examine the incidence of intracapsular hemorrhage in orbital fracture repair with non-fixated nylon sheet implants. METHODS: A retrospective chart review of 227 patients presenting from January 2013 to December 2016 for orbital fracture repair with nylon sheet implants. RESULTS: Of the 331 orbital fractures repaired over 4 years, a total of 227 met inclusion criteria. The average implant thickness was 0.38 mm and no implants were fixated. Four total implants (1.8%) were removed due to complications; one each secondary to exploration for ongoing postoperative diplopia, immediate post-operative orbital hemorrhage, a cystic mass anterior to the implant, and pain. There were no cases of intracapsular hemorrhage nor infection for any of the 227 patients over 4 years. CONCLUSIONS: To the authors knowledge, this represents the largest case series to date to assess the rate of intracapsular hemorrhage in non-fixated nylon sheet orbital implants. In the 227 cases reviewed over a 4-year period, there were no cases of intracapsular hemorrhage. This suggests a much lower complication rate than previously reported. PRéCIS: A case series of 227 patients who underwent orbital fracture repair with non-fixated nylon sheet implants.


Assuntos
Hemorragia Ocular/epidemiologia , Nylons/efeitos adversos , Fraturas Orbitárias/cirurgia , Implantes Orbitários/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diplopia/epidemiologia , Diplopia/etiologia , Hemorragia Ocular/etiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
7.
Ophthalmic Plast Reconstr Surg ; 35(4): 403-406, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30908466

RESUMO

PURPOSE: To evaluate the efficacy in degree of ptosis correction achieved by single suture Müeller muscle conjunctival resection (ssMMCR) when compared with that of traditional MMCR. METHODS: A retrospective chart analysis of patients who underwent either ssMMCR or traditional MMCR at 2 institutions. Single suture MMCR was performed after using a ptosis clamp to imbricate conjunctiva and Müeller muscle. Margin-to-reflex distance 1 was measured pre- and postoperatively, and the change in margin-to-reflex distance 1 was analyzed for both groups. Patients were monitored in follow up for postoperative complications including lagophthalmos, corneal abrasions, and change in visual acuity. Statistical analysis was performed using the Microsoft Excel and Stata software programs. RESULTS: Twenty-seven and 30 patients underwent single suture and traditional MMCR, respectively. The ssMMCR and MMCR groups were followed postoperatively for approximately 4.2 and 9.7 months, respectively and the average margin-to-reflex distance 1 increased by 2.93 mm and 2.81 mm, respectively. Notably, there was no statistically significant difference in the means identified by t test. Of the 94 eyelid surgeries evaluated, 1 ssMMCR and 3 MMCR eyelids required further surgical revision for persistent ptosis, and 1 ssMMCR developed a transient corneal epithelial abrasion. Surgical revisions were rare with both procedures, and patient satisfaction was high. CONCLUSIONS: Single suture MMCR is an efficient and effective method for ptosis repair. It results in comparable outcomes including elevation in margin-to-reflex distance 1, safety profile, and reoperation rates, when compared with traditional MMCR.


Assuntos
Blefaroplastia/métodos , Blefaroptose/cirurgia , Túnica Conjuntiva/cirurgia , Músculos Oculomotores/cirurgia , Técnicas de Sutura/instrumentação , Suturas , Idoso , Idoso de 80 Anos ou mais , Pálpebras/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
8.
Ophthalmic Plast Reconstr Surg ; 35(1): 67-70, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30198963

RESUMO

PURPOSE: The aim of this study was to evaluate the efficacy of the nonporous polyethylene barrier sheet as an alternative for nylon foil (SupraFOIL) implants in repair of orbital fractures. METHODS: This is a prospective, case series using the Stryker 0.4-mm-thick nonporous polyethylene barrier sheet in all patients over the age of 18 years presenting with orbital fractures from December 2014 to June 2015. Patient's age, location of fracture, etiology of injury, presence of preoperative restriction and diplopia, and postoperative diplopia and/or enophthalmos was recorded. Institutional review board approval was received, and consent was obtained from all participants. Patients were followed for at least 6 months when possible. Scanning electron microscopy was used to compare the thickness, surface characteristics, and porosity of the nonporous polyethylene barrier and nylon foil implants. Beam deflection testing was also performed to compare the biomechanical properties of each implant. RESULTS: Forty-six patients who underwent repair of orbital fractures with the nonporous polyethylene barrier sheet were included in this series. Average age was 43.3 years (range: 18-84 years). Twenty-six of 46 patients (56.5%) were males, and 20 (43.4%) were females. The most common causes of injuries were assault (38.3%), falls (25.5%), motor vehicle accident (14.9%), and sports related (10.5%). Twenty of 46 patients (43.4%) had isolated orbital floor, and 2 patients (4.3%) had isolated medial wall fractures. Fifteen patients (32.6%) had combined floor and medial wall fractures involving the inferomedial orbital strut, and 9 (19.6%) had floor fractures associated with zygomaticomaxillary complex or lateral wall fractures. Twenty-eight patients (60.9%) had preoperative diplopia. Timing of surgery was between 3 and 55 days, with the median of 11.5 days. Five of 46 patients (10.8%) had residual diplopia at their 1-week postoperative visit, 4 of those patients' diplopia had resolved at 2 months postoperatively. One patient had residual diplopia at 6-month follow up. Electron microscopy showed that the 0.4-mm nonporous polyethylene barrier implant was thinner (0.33 mm) than expected and thinner than 0.4-mm SupraFOIL (0.38 mm). Scanning electron microscopy exhibited that the surface of the nonporous polyethylene barrier was smooth and nonporous. Beam deflection testing showed that for small forces (<100 mN), the 2 materials behaved nearly identically, but at higher forces, the nonporous polyethylene implant exhibited less stiffness. CONCLUSIONS: The use of nonporous polyethylene barrier sheet implant for orbital fracture repair is a safe and effective alternative to nonporous nylon foil implants. There were no complications and one case of residual diplopia (2.1%) in this case series.


Assuntos
Fixação de Fratura/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Implantes Orbitários , Procedimentos de Cirurgia Plástica/métodos , Polietileno , Implantação de Prótese/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Orbitárias/diagnóstico , Fraturas Orbitárias/cirurgia , Porosidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
9.
Orbit ; 38(4): 318-321, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30388918

RESUMO

Purpose: The anterior vestibule salvaging ('Birdcage') technique may limit orbital implant extrusion following evisceration. Methods: A 10-year retrospective chart review from 2005 to 2015 of individuals who underwent evisceration procedures utilizing the vestibule salvaging technique was performed. Results: A total of 96 patients (61 male; 35 female; average age 64 years; range 17-96 years) underwent evisceration with a technique avoiding anterior scleral relaxing incisions. Three (3.1%) patients had documented extrusion of the silicone implant. Time from evisceration to extrusion ranged from 26 to 372 days. Conclusions: Maintenance of the anterior scleral vestibule during evisceration may decrease extrusion rates after surgery compared with traditional evisceration techniques that utilize anterior relaxing incisions.


Assuntos
Evisceração do Olho , Procedimentos Cirúrgicos Oftalmológicos , Implantes Orbitários , Complicações Pós-Operatórias/prevenção & controle , Esclera/cirurgia , Elastômeros de Silicone , Deiscência da Ferida Operatória/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos , Adulto Jovem
10.
Am J Otolaryngol ; 39(5): 472-475, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29776684

RESUMO

PURPOSE: To present the results of treating combined lower eyelid laxity, retraction and midface descent secondary to facial nerve weakness with a hybrid surgical procedure. MATERIALS AND METHODS: A retrospective analysis of patients from January 2015 to January 2017 who underwent a hybrid surgical technique for the treatment of corneal exposure secondary to facial nerve paresis with a single surgeon was performed. Age, gender, and presence of exposure symptoms were recorded pre-operatively. Outcomes assessed included improvement of lower eyelid laxity and position, operative complications, and post-operative symptomatic relief. RESULTS: A total of 11 patients underwent unilateral eyelid surgery. All patients had symptomatic relief and good functional outcomes defined as improvement in eyelid laxity, lower eyelid position, and objective corneal exposure. No cases required reoperation during an average follow up of 174.5 days. CONCLUSIONS: Combining portions of a tarsorrhaphy and lateral wedge resection technique is a simple and effective procedure to improve lower eyelid position and limit corneal exposure secondary to facial nerve paresis.


Assuntos
Blefaroplastia/métodos , Doenças Palpebrais/etiologia , Doenças Palpebrais/cirurgia , Doenças do Nervo Facial/complicações , Procedimentos de Cirurgia Plástica/métodos , Adulto , Idoso , Estudos de Coortes , Córnea/fisiopatologia , Estética , Doenças Palpebrais/fisiopatologia , Pálpebras/inervação , Doenças do Nervo Facial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paresia/complicações , Paresia/diagnóstico , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento
11.
Ophthalmic Plast Reconstr Surg ; 34(4): 387-389, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29356717

RESUMO

PURPOSE: To review physician-based clinical surveys published in Ophthalmic Plastic and Reconstructive Surgery. METHODS: Complementary Ovid and PubMed searches of Ophthalmic Plastic and Reconstructive Surgery journal content were performed for the term "survey." Results were narrowed to studies that specifically addressed physicians' clinical practices. This search resulted in 162 articles, and after dual-investigator independent screening, 13 surveys met inclusion criteria. RESULTS: Of the 13 surveys published from 2007 to January 2017, 6 were published since 2015, showing an increased trend in survey-based publications. Topics included assessing practice patterns regarding eyelid disorders, thyroid eye disease, optic nerve sheath fenestration, anophthalmic socket, and diagnosing lacrimal disorders. Average response rate was 38.7% (range 17.5-60%), with 201 average number of replies (range 72-310). Nine out of 13 surveys included some form of statistical analysis with the remainder presenting data in percentages. CONCLUSIONS: There has been an increased rate of survey-type publications in Ophthalmic Plastic and Reconstructive Surgery over the past 10 years. The low response rate and frequent lack of statistical analysis raise concerns regarding the validity and usefulness of such studies. The authors believe that survey studies can be improved through better standardization and the use of author guidelines. They have made specific recommendations to improve the impact of survey papers in the future.


Assuntos
Pesquisas sobre Atenção à Saúde/tendências , Pesquisa sobre Serviços de Saúde/métodos , Oftalmologia , Publicações Periódicas como Assunto , Procedimentos de Cirurgia Plástica , Editoração/tendências , Cirurgia Plástica , Humanos , Estudos Retrospectivos
12.
Orbit ; 37(5): 315-320, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29300514

RESUMO

To assess the practice patterns of current members of the American Society of Ophthalmic Plastic and Reconstructive Surgery (ASOPRS) in the treatment of medically refractive endophthalmitis (MRE). A 17-question survey included the procedure of choice for MRE, the preferred type of orbital implant, the timing of implant placement, and the incidence of postoperative complications. 107 ASOPRS members participated in the study. In the setting of MRE, 72% preferred evisceration versus 28% who preferred enucleation. Fifty-nine percent of responders preferred enucleation if the MRE extended to orbital tissues versus 27% who would eviscerate. Among those that would place an orbital implant at the initial surgery, 65% would do so during an enucleation and 58% would do so during an evisceration. If an orbital implant was placed at the initial surgery, 52% of responders preferred a silicone implant, while 17% preferred hydroxyapatite implant. A minority of responders (6%) reported "yes" to ever having infectious complications after primary enucleation, compared to 10% after primary evisceration. Overall, 12% of responders noted more frequent complications (other than infectious) when an enucleation was performed compared to 5% for eviscerations. Current opinions on the surgical management of MRE show a trend toward evisceration, with 65% of ASOPRS respondents placing an orbital implant at the time of an enucleation and 58% at the time of an evisceration. Enucleation was preferred when involvement of orbital tissues was apparent. Both evisceration and enucleation remain a viable treatment option for MRE. The most appropriate initial approach is best determined by careful patient selection and informed decision-making by the patient.


Assuntos
Endoftalmite/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Endoftalmite/diagnóstico , Enucleação Ocular/estatística & dados numéricos , Evisceração do Olho/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmologia/organização & administração , Implantes Orbitários/estatística & dados numéricos , Complicações Pós-Operatórias , Implantação de Prótese , Recidiva , Sociedades Médicas/estatística & dados numéricos , Inquéritos e Questionários , Fatores de Tempo , Estados Unidos
13.
Am J Otolaryngol ; 39(1): 34-36, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28969869

RESUMO

PURPOSE: To report a series of patients with extra-ocular movement restriction and diplopia after orbital fracture repair, and determine the effect of timing of repair and the type of implant used. METHODS: A chart review was conducted identifying all patients >18years of age at our institution between June 2005 and June 2008 who underwent orbital fracture repair, and presented with clinically significant diplopia and extra-ocular movement restriction persisting longer than one month after repair. Data collected included timing of repair, implant used within the orbit, and need for revision. RESULTS: Ten patients were identified with a mean time to primary orbital fracture repair at 9days (range 1-48). Seven patients underwent revision of their orbital fracture repair with removal of the previously placed implant and replacement with non-porous 0.4mm Supramid Foil, whereas one patient underwent lateral and inferior rectus recessions without revision of primary fracture repair. Titanium mesh was the intra-orbital implant found in all patients requiring revision of orbital fracture repair. All revisions resulted in resolution of clinically significant diplopia. CONCLUSIONS: Clinically significant diplopia and extra-ocular movement restriction is not an uncommon complication after orbital fracture repair. In our series, there was a strong association between these complications and the use of porous titanium mesh implants. Revision of fractures significantly improved diplopia in all but one patient. This suggests that meticulous fracture repair and the use of non-porous implants primarily or secondarily may preclude the need for strabismus surgery after orbital trauma.


Assuntos
Diplopia/etiologia , Fixação de Fratura/efeitos adversos , Transtornos da Motilidade Ocular/etiologia , Fraturas Orbitárias/cirurgia , Telas Cirúrgicas/efeitos adversos , Adulto , Estudos de Coortes , Diplopia/fisiopatologia , Diplopia/cirurgia , Feminino , Seguimentos , Fixação de Fratura/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos da Motilidade Ocular/fisiopatologia , Transtornos da Motilidade Ocular/cirurgia , Fraturas Orbitárias/complicações , Fraturas Orbitárias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Próteses e Implantes , Recuperação de Função Fisiológica , Reoperação/métodos , Estudos Retrospectivos , Titânio , Resultado do Tratamento , Adulto Jovem
14.
Orbit ; 36(6): 392-396, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28812914

RESUMO

Optic nerve sheath meningiomas (ONSM) and intra-conal orbital lymphomas are common entities on the differential of a retrobulbar optic nerve involving space-occupying lesion. In this study, we compare the pre-surgical diagnosis, based on clinical presentation and neuroimaging, to the surgical pathology results of intra-conal orbital lymphomas and ONSM. This is an IRB approved retrospective chart review of orbital lymphomas and optic nerve sheath meningiomas biopsied by a single surgeon over a 4-year period at a single institution. Pre-surgical diagnosis and surgical pathology were compared. Fifteen cases of orbital lymphoma were identified. Fourteen were excluded based on extra-conal location. The single histologically confirmed intra-conal orbital lymphoma had a pre-surgical diagnosis of ONSM. Four cases of optic nerve sheath meningioma were identified. Three of the 4 cases of histologically confirmed ONSM had a pre-surgical diagnosis of ONSM. One of the 4 had a pre-surgical diagnosis of lymphoma. Diagnosis based on surgical pathology differed from the pre-surgical diagnosis in 2 out of 5 cases showing that clinical diagnosis does not always correlate with histologic diagnosis. Although both diseases are typically managed with radiation therapy, the treatment dosage and systemic disease implications are very different. These findings emphasis the importance of biopsy in the diagnosis of orbital lesions surrounding the optic nerve.


Assuntos
Linfoma/diagnóstico por imagem , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/diagnóstico por imagem , Neoplasias do Nervo Óptico/diagnóstico por imagem , Neoplasias Orbitárias/diagnóstico por imagem , Adulto , Biópsia , Feminino , Humanos , Linfoma/cirurgia , Imageamento por Ressonância Magnética , Masculino , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Neoplasias do Nervo Óptico/cirurgia , Neoplasias Orbitárias/cirurgia , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
15.
Digit J Ophthalmol ; 23(4): 8-12, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29403334

RESUMO

PURPOSE: To report our experience with protractor myectomy in patients with benign essential blepharospasm who did not respond to serial botulinum toxin injection, and to describe intra- and postoperative techniques that limited skin contracture while also providing excellent functional and cosmetic results. METHODS: The medical records of patients with isolated, benign, essential blepharospasm who underwent protractor myectomy from 2005 to 2008 by a single surgeon were reviewed retrospectively. The technique entailed operating on a single eyelid during each procedure, using a complete en bloc resection of all orbicularis tissue, leaving all eyelid skin intact at the time of surgery, and placing the lid under stretch with Frost suture and applying a pressure dressing for 5-7 days. RESULTS: Data from 28 eyelids in 7 patients were included. Average follow-up was 21.5 months (range, 4-76 months). Of the 28 eyelids, 20 (71.4%) showed postoperative resolution of spasm, with no further need for botulinum toxin injections. In the 8 eyelids requiring further injections, the average time to injection after surgery was 194 days (range, 78-323 days), and the average number of injections was 12 (range, 2-23 injections). All but one eyelid had excellent cosmetic results, without signs of contracture; one eyelid developed postoperative skin contracture following premature removal of the Frost suture and pressure dressing because of concerns over increased intraocular pressure. CONCLUSIONS: In our patient cohort, this modified technique resulted in excellent cosmetic and functional results and limited postoperative skin contracture.


Assuntos
Blefarospasmo/cirurgia , Contratura/cirurgia , Pálpebras/cirurgia , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Complicações Pós-Operatórias/cirurgia , Dermatopatias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Contratura/diagnóstico , Contratura/etiologia , Pálpebras/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Reoperação , Estudos Retrospectivos , Pele/patologia , Dermatopatias/diagnóstico , Dermatopatias/etiologia , Fatores de Tempo , Resultado do Tratamento
16.
Ophthalmic Plast Reconstr Surg ; 32(3): e71-2, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25186215

RESUMO

Histoplasma capsulatum var capsulatum is a dimorphic fungus endemic to the Ohio and Mississippi River Valleys of the United States. In this case report, a 33-year-old woman who presented with a right orbital mass causing progressive vision loss, diplopia, and facial swelling is described. Lateral orbitotomy with lateral orbital wall bone flap was performed for excisional biopsy of the lesion. The 1.5 × 1.8 × 2.3 cm cicatricial mass demonstrated a granulomatous lesion with necrosis and positive staining consistent with Histoplasma capsulatum var capsulatum infection. To the authors' knowledge, this is the first case of orbital histoplasmosis to be reported in the United States and the first case worldwide of orbital histoplasmosis due to Histoplasma capsulatum var capsulatum.


Assuntos
Infecções Oculares Fúngicas/diagnóstico , Histoplasma/isolamento & purificação , Histoplasmose/diagnóstico , Órbita/diagnóstico por imagem , Doenças Orbitárias/diagnóstico , Adulto , Biópsia , Diagnóstico Diferencial , Infecções Oculares Fúngicas/microbiologia , Feminino , Histoplasmose/microbiologia , Humanos , Imageamento por Ressonância Magnética , Órbita/microbiologia , Doenças Orbitárias/microbiologia
17.
Ophthalmic Plast Reconstr Surg ; 32(6): e154-e156, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25393905

RESUMO

A 13-month-old boy was presented with new onset proptosis of the right eye. CT scan and MRI showed an enhancing mass in the right superior orbit with local bone remodeling and erosion. A craniotomy was performed for biopsy and sub-total resection. Histopathology and immunohistochemistry confirmed the lesion to be nodular fasciitis. Nodular fasciitis lesions are classically found in the anterior ocular adnexa, especially in pediatric patients. This is the first reported case of nodular fasciitis arising in the posterior orbit of a child younger than 16.


Assuntos
Fasciite/diagnóstico , Órbita/diagnóstico por imagem , Biópsia , Diagnóstico Diferencial , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada por Raios X
18.
Ophthalmic Plast Reconstr Surg ; 32(6): e137-e138, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25393906

RESUMO

Porous polyethylene is commonly used in the orbit for fracture repair and anophthalmic reconstruction; it reportedly has a good safety profile and integrates well into host tissue. Foreign body reaction to porous polyethylene has been reported in facial tissue, but to our knowledge, not in the orbit. The authors report 2 cases of foreign body inflammatory giant cell reaction in patients who underwent orbital fracture repairs with porous polyethylene implants.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Granuloma de Corpo Estranho/etiologia , Implantes Orbitários/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Polietileno/efeitos adversos , Adulto , Biópsia , Diagnóstico Diferencial , Granuloma de Corpo Estranho/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X
19.
Am J Ophthalmol Case Rep ; 2: 1-3, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29503887

RESUMO

PURPOSE: We report here a newborn male infant with striking features consistent with severe Pfeiffer syndrome type II, including cloverleaf skull deformity with pansynostosis, extreme proptosis, upper extremity contractures, broad big toes and thumbs with varus deviation and genetic mutation in the FGFR2 gene. The authors review the ophthalmic complications in Pfeiffer syndrome and discuss the unique surgical strategies used for obtaining adequate corneal coverage in these unique patients. OBSERVATIONS: Ophthalmic considerations in Type 2 Pfeiffer Syndrome include vision loss secondary to increased intracranial pressure, and extreme proptosis as a result of orbitostenosis and midfacial retrusion. Our patient has undergone multiple ophthalmic/oculoplastic, neurosurgical, and midfacial surgeries as a result of corneal deterioration due to extreme exorbitism. CONCLUSIONS AND IMPORTANCE: It is important for ophthalmologists to be aware of the ophthalmic complications associated with patients with craniosynostosis syndromes. Our case identifies the importance of close communication between ophthalmology and plastic reconstructive surgery to help formulate the most successful plan in treating corneal decompensation and proptosis in Pfeiffer Syndrome patients.

20.
Ophthalmic Plast Reconstr Surg ; 31(4): 323-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26020720

RESUMO

PURPOSE: To describe a technique to correct lower eyelid malposition and lagophthalmos due to facial nerve palsy. METHODS: Chart review was performed and identified 13 patients with facial nerve palsy, who presented with paralytic eyelid malposition and were treated with recession and extirpation of the lower eyelid retractors between September 2012 and March 2014 by 1 surgeon (HBL). RESULTS: A total of 12 eyelids in 11 patients met inclusion criteria. Mean preoperative MRD2 was 10 mm (range, 9.0-12.0 mm) and the mean postoperative MRD2 was 7 mm (range, 5.0-9.0 mm). The MRD2 improved an average of 3.0 mm in each patient (range, 2.0-4.0 mm). Patients had an average of 6.9 mm (range, 4.0-10.0 mm) of lagophthalmos preoperatively, which improved to 2.1 mm (range, 0.0-4 mm). The amount of lagophthalmos improved an average of 4.8 mm in the patients. There were no complications encountered in the patients. All patients had a subjective improvement in ocular comfort. CONCLUSIONS: The authors' surgical technique is effective in addressing lower eyelid malposition and ocular surface disease in paralytic lagophthalmos.


Assuntos
Ectrópio/cirurgia , Doenças Palpebrais/cirurgia , Pálpebras/cirurgia , Paralisia Facial/cirurgia , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Adulto , Idoso , Túnica Conjuntiva/cirurgia , Ectrópio/etiologia , Doenças Palpebrais/etiologia , Paralisia Facial/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Retalhos Cirúrgicos , Técnicas de Sutura , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA