Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
J Cyst Fibros ; 22(4): 715-721, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37400300

RESUMO

BACKGROUND: Medical radiation exposure is of increasing concern in patients with cystic fibrosis (PWCF) due to improving life expectancy. We aimed to assess and quantify the cumulative effective dose (CED) in PWCF in the context of CFTR-modulator therapy and the advancement of dose reduction techniques. METHODS: We performed a retrospective observational study in a single University CF centre over a 11-year period. We included PWCF, aged over 18 years who exclusively attended our institution. Relevant clinical data (demographics, transplantation history and modulator status) and radiological data (modality, quantity, and radiation exposure measured as CED) were collected. For those on modulator therapy the quantified imaging and radiation data was dichotomised into pre-and-post therapy periods. RESULTS: The study included 181 patients: 139 on CFTR modulator therapy, 15 transplant recipients and 27 with neither exposure. 82% of patients received <25 mSv over the study period. Mean study duration was 6.9 ± 2.6 years pre-modulation and 4.2 ± 2.6 years post-modulation. Pre-modulation CT contributed 9.6% of total chest imaging (n = 139/1453) and 70.9% of the total CED. Post-modulation CT use increased contributing 42.7% of chest imaging (n = 444/1039) and comprised 75.8% of CED. Annual CED was 1.55 mSv pre and 1.36 mSv post modulation (p = 0.41). Transplant recipients had an annual CED of 64 ± 36.1mSv. CONCLUSION: Chest CT utilisation for PWCF is rising in our institution, replacing chest radiography amidst CFTR-modulation. Despite the increasing use of CT, no significant radiation dose penalty was observed with a reduction in mean annual CED, primarily due to the influence of CT dose reduction strategies.


Assuntos
Fibrose Cística , Humanos , Adulto , Pessoa de Meia-Idade , Fibrose Cística/diagnóstico por imagem , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Radiografia , Tórax
2.
Diagnostics (Basel) ; 12(12)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36552922

RESUMO

Post-embolisation syndrome (PES) is a prevalent complication that occurs in patients following uterine artery embolisation (UAE) for the treatment of uterine fibroids. The aetiology of PES remains incompletely understood, although postulated to result secondary to tissue infarction resulting in release of inflammatory mediators. We followed PRISMA guidelines and performed a systematic review of studies of PES following UAE from inception to October 2022. Our published protocol was prospectively registered. Our search yielded 54 results. We reviewed 22 full texts, and nine articles were included. Observational studies comprised 6/9 relevant studies, with 5/9 retrospective design. The rate of PES was documented in 5/8 studies (excluding case report) with a reported incidence ranging from 4-34.6%. Five of the nine studies studies postulated that the aetiological basis of PES is inflammatory related. Further research is necessary to advance our understanding of PES to define the biological basis of the syndrome with more certainty and gain a consensus on peri-procedure management to reduce incidence and improve patient outcomes.

3.
Scand J Gastroenterol ; 57(2): 175-182, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34699288

RESUMO

Background and aims: Computed tomography (CT), often more accessible than magnetic resonance imaging (MRI), remains widely used though radiation exposure is an obvious disadvantage. We previously showed that modern CT technology can achieve over 70% reduction in radiation-dose without loss of accuracy. Here, we compare low- versus conventional-dose CT in patients with known Crohn's disease to assess clinical confidence and accuracy of the low-dose procedure in the semi-acute setting.Methods: A comparative study of low-dose CT with full iterative reconstruction (IR) versus conventional-dose CT was conducted in 50 consecutive outpatients with Crohn's disease. Clinicians were provided with the low-dose images and reports, whereas conventional-dose images were reviewed after 4 weeks.Results: The clinical question was adequately addressed with low-dose IR imaging in all cases. Complications of Crohn's were detected in 37/50 (74%) with no disagreement between low- and conventional-dose imaging. The effective radiation dose reduction was 76.5% (low-dose mean 2.15 mSv versus conventional-dose CT 6.99 mSv).Conclusion: Low-dose IR CT is safe and accurate for evaluating distribution and complications of known Crohn's disease in the outpatient setting. We propose that low-dose radiation imaging should be adopted as standard-of-care for the evaluation of Crohn's disease and an acceptable alternative to MR particularly in the acute setting. ClinicalTrials.gov: NCT03140306.


Assuntos
Doença de Crohn , Exposição à Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Doses de Radiação
4.
JAMA Netw Open ; 4(8): e2115274, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34459908

RESUMO

Importance: Obesity, particularly visceral obesity and sarcopenia, are poor prognostic indicators in colon cancer. Objectives: To explore the association between body composition profiles and 5-year colon cancer outcomes and delineate the associated underlying inflammatory processes. Design, Setting, and Participants: This multicenter translational cohort study included patients with nonmetastatic colon cancer who did not have underlying chronic inflammatory disorders and were not receiving anti-inflammatory drugs referred to tertiary cancer centers from 2009 to 2015. Preoperative acute phase proteins (white cell count, C-reactive protein, and albumin), cytokines (interleukin [IL]-1b, IL-2, IL-6, IL-10, interferon γ, and tumor necrosis factor α), vascular endothelial growth factor (VEGF), and cell surface receptor expression levels (CD11b and CD14) were measured. All patients underwent follow-up for at least 5 years. Data were analyzed in December 2020. Exposure: Nonmetastatic colon cancer. Main Outcomes and Measures: The associations of body composition profiles with 5-year cancer recurrence and disease-specific mortality were analyzed using Mantel Cox log-rank test and Kaplan-Meier curves. Results: A total of 28 patients were included (median [interquartile range] age, 67 [58-72] years; 22 [78.6%] men). Low skeletal muscle area (SMA) and high visceral to total fat ratio were associated with poor clinical and oncological outcomes, including increased 5-year recurrence (low SMA: hazard ratio [HR], 2.30 [95% CI, 1.41-2.89]; P = .04; high visceral to total fat ratio: HR, 5.78 [95% CI, 3.66-7.95]; P = .02). High visceral to total fat ratio was associated with increased 5-year disease-specific mortality (HR, 5.92 [95% CI, 4.04-8.00]; P = .02). Patients with low SMA who developed a cancer recurrence, compared with those who did not, had higher C-reactive protein (mean [SD], 31.24 [6.95] mg/dL vs 8.11 [0.58] mg/dL; P = .003), IL-6 (mean [SD], 1.93 [1.16] ng/mL vs 0.88 [0.14] ng/mL; P = .004), VEGF (mean [SD], 310.03 [122.66] ng/mL vs 176.12 [22.94] ng/mL; P = .007), and CD14 (mean [SD], 521.23 [302.02] ng/mL vs 322.07 [98.35] ng/mL; P = .03) expression and lower albumin (mean [SD], 3.8 [0.6] g/dL vs 43.50 [3.69] g/dL; P = .01), IL-2 (mean [SD], 0.45 [0.25] ng/mL vs 0.94 [0.43] ng/mL; P < .001), IL-10 (mean [SD], 8.15 [1.09] ng/mL vs 16.32 [4.43] ng/mL; P = .004), and interferon γ (mean [SD], 2.61 [1.36] ng/mL vs 14.87 [3.43] ng/mL; P = .02) levels. Patients with high visceral to total fat ratio who developed recurrence had higher levels of IL-6 (mean [SD], 5.26 [7.05] ng/mL vs 2.76 [3.11] ng/mL; P = .03) and tumor necrosis factor α (mean [SD], 5.74 [4.53] ng/mL vs 4.50 [1.99] ng/mL; P = .03). Conclusions and Relevance: These findings suggest that low SMA and high visceral to total fat ratio were associated with worse colon cancer outcomes and with increased expression of proinflammatory cytokines and VEGF and inhibition of anti-inflammatory cytokines.


Assuntos
Composição Corporal , Neoplasias do Colo/mortalidade , Neoplasias do Colo/fisiopatologia , Tecido Adiposo/fisiopatologia , Idoso , Proteína C-Reativa/análise , Antígeno CD11b/sangue , Neoplasias do Colo/cirurgia , Citocinas/sangue , Feminino , Humanos , Inflamação , Gordura Intra-Abdominal/fisiopatologia , Estimativa de Kaplan-Meier , Contagem de Leucócitos , Receptores de Lipopolissacarídeos/sangue , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/fisiopatologia , Período Pré-Operatório , Modelos de Riscos Proporcionais , Albumina Sérica/análise , Fator A de Crescimento do Endotélio Vascular/sangue
5.
Eur Radiol Exp ; 5(1): 26, 2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-34180040

RESUMO

BACKGROUND: Cerebrospinal fluid shunts in the treatment of hydrocephalus, although associated with clinical benefit, have a high failure rate with repeat computed tomography (CT) imaging resulting in a substantial cumulative radiation dose. Therefore, we sought to develop a whole-body ultralow-dose (ULD) CT protocol for the investigation of shunt malfunction and compare it with the reference standard, plain radiographic shunt series (PRSS). METHODS: Following ethical approval, using an anthropomorphic phantom and a human cadaveric ventriculoperitoneal shunt model, a whole-body ULD-CT protocol incorporating two iterative reconstruction (IR) algorithms, pure IR and hybrid IR, including 60% filtered back projection and 40% IR was evaluated in 18 adult patients post new shunt implantation or where shunt malfunction was suspected. Effective dose (ED) and image quality were analysed. RESULTS: ULD-CT permitted a 36% radiation dose reduction (median ED 0.16 mSv, range 0.07-0.17, versus 0.25 mSv (0.06-1.69 mSv) for PRSS (p = 0.002). Shunt visualisation in the thoracoabdominal cavities was improved with ULD-CT with pure IR (p = 0.004 and p = 0.031, respectively) and, in contrast to PRSS, permitted visualisation of the entire shunt course (p < 0.001), the distal shunt entry point and location of the shunt tip in all cases. For shunt complications, ULD-CT had a perfect specificity. False positives (3/22, 13.6%) were observed with PRSS. CONCLUSIONS: At a significantly reduced radiation dose, whole body ULD-CT with pure IR demonstrated diagnostic superiority over PRSS in the evaluation of cerebrospinal fluid shunt malfunction.


Assuntos
Hidrocefalia , Tomografia Computadorizada por Raios X , Adulto , Algoritmos , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Doses de Radiação , Derivação Ventriculoperitoneal/efeitos adversos
6.
AJR Am J Roentgenol ; 217(2): 304-313, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34076456

RESUMO

OBJECTIVE. Cystic fibrosis (CF) is a multisystemic life-limiting disorder. The leading cause of morbidity in CF is chronic pulmonary disease. Chest CT is the reference standard for detection of bronchiectasis. Cumulative ionizing radiation limits the use of CT, particularly as treatments improve and life expectancy increases. The purpose of this article is to summarize the evidence on low-dose chest CT and its effect on image quality to determine best practices for imaging in CF. CONCLUSION. Low-dose chest CT is technically feasible, reduces dose, and renders satisfactory image quality. There are few comparison studies of low-dose chest CT and standard chest CT in CF; however, evidence suggests equivalent diagnostic capability. Low-dose chest CT with iterative reconstructive algorithms appears superior to chest radiography and equivalent to standard CT and has potential for early detection of bronchiectasis and infective exacerbations, because clinically significant abnormalities can develop in patients who do not have symptoms. Infection and inflammation remain the primary causes of morbidity requiring early intervention. Research gaps include the benefits of replacing chest radiography with low-dose chest CT in terms of improved diagnostic yield, clinical decision making, and patient outcomes. Longitudinal clinical studies comparing CT with MRI for the monitoring of CF lung disease may better establish the complementary strengths of these imaging modalities.


Assuntos
Fibrose Cística/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Bronquiectasia/diagnóstico por imagem , Bronquiectasia/etiologia , Fibrose Cística/complicações , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Doses de Radiação , Adulto Jovem
7.
Pediatr Radiol ; 51(4): 544-553, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33743038

RESUMO

Thoracic computed tomography (CT) is the imaging reference method in the diagnosis, assessment and management of lung disease. In the setting of cystic fibrosis (CF), CT demonstrates increased sensitivity compared with pulmonary function tests and chest radiography, and findings correlate with clinical outcomes. Better understanding of the aetiology of CF lung disease indicates that even asymptomatic infants with CF can have irreversible pulmonary pathology. Surveillance and early diagnosis of lung disease in CF are important to preserve lung parenchyma and to optimise long-term outcomes. CF is associated with increased cumulative radiation exposure due to the requirement for repeated imaging from a young age. Radiation dose optimisation, important for the safe use of CT in children with CF, is best achieved in a team environment where paediatric radiologists work closely with paediatric respiratory physicians, physicists and radiography technicians to achieve the best patient outcomes. Despite the radiation doses incurred, CT remains a vital imaging tool in children with CF. Radiologists with special interests in CT dose optimisation and respiratory disease are key to the appropriate use of CT in paediatric imaging. Paediatric radiologists strive to minimise radiation dose to children whilst providing the best possible assessment of lung disease.


Assuntos
Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Fibrose Cística/patologia , Diagnóstico por Imagem/métodos , Humanos , Lactente , Doses de Radiação , Radiografia Torácica/métodos
8.
Gastroenterol Res Pract ; 2018: 1768716, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30515203

RESUMO

Magnetic resonance imaging (MRI) is the mainstay method for the radiological imaging of the small bowel in patients with inflammatory bowel disease without the use of ionizing radiation. There are circumstances where imaging using ionizing radiation is required, particularly in the acute setting. This usually takes the form of computed tomography (CT). There has been a significant increase in the utilization of computed tomography (CT) for patients with Crohn's disease as patients are frequently diagnosed at a relatively young age and require repeated imaging. Between seven and eleven percent of patients with IBD are exposed to high cumulative effective radiation doses (CEDs) (>35-75 mSv), mostly patients with Crohn's disease (Newnham E 2007, Levi Z 2009, Hou JK 2014, Estay C 2015). This is primarily due to the more widespread and repeated use of CT, which accounts for 77% of radiation dose exposure amongst patients with Crohn's disease (Desmond et al., 2008). Reports of the projected cancer risks from the increasing CT use (Berrington et al., 2007) have led to increased patient awareness regarding the potential health risks from ionizing radiation (Coakley et al., 2011). Our responsibilities as physicians caring for these patients include education regarding radiation risk and, when an investigation that utilizes ionizing radiation is required, to keep radiation doses as low as reasonably achievable: the "ALARA" principle. Recent advances in CT technology have facilitated substantial radiation dose reductions in many clinical settings, and several studies have demonstrated significantly decreased radiation doses in Crohn's disease patients while maintaining diagnostic image quality. However, there is a balance to be struck between reducing radiation exposure and maintaining satisfactory image quality; if radiation dose is reduced excessively, the resulting CT images can be of poor quality and may be nondiagnostic. In this paper, we summarize the available evidence related to imaging of Crohn's disease, radiation exposure, and risk, and we report recent advances in low-dose CT technology that have particular relevance.

9.
Eur Radiol Exp ; 2(1): 38, 2018 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-30483977

RESUMO

BACKGROUND: The size-specific dose estimate (SSDE) is a dose-related metrics that incorporates patient size into its calculation. It is usually derived from the volume computed tomography dose index (CTDIvol) by applying a conversion factor determined from manually measured anteroposterior and lateral skin-to-skin patient diameters at the midslice level on computed tomography (CT) localiser images, an awkward, time-consuming, and not highly reproducible technique. The objective of this study was to evaluate the potential for the use of body mass index (BMI) as a size-related metrics alternative to the midslice effective diameter (DE) to obtain a size-specific dose (SSDE) in abdominal CT. METHODS: In this retrospective study of patients who underwent abdominal CT for the investigation of inflammatory bowel disease, the DE was measured on the midslice level on CT-localiser images of each patient. This was correlated with patient BMI and the linear regression equation relating the quantities was calculated. The ratio between the internal and the external abdominal diameters (DRATIO) was also measured to assess correlation with radiation dose. Pearson correlation analysis and linear regression models were used. RESULTS: There was good correlation between DE and patient BMI (r = 0.88). An equation allowing calculation of DE from BMI was calculated by linear regression analysis as follows: DE = 0.76 (BMI) + 9.4. A weak correlation between radiation dose and DRATIO was demonstrated (r = 0.45). CONCLUSIONS: Patient BMI can be used to accurately estimate DE, obviating the need to measure anteroposterior and lateral diameters in order to calculate a SSDE for abdominal CT.

10.
J Gastric Cancer ; 18(3): 242-252, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30276001

RESUMO

PURPOSE: Surgical resection for gastric adenocarcinoma is associated with significant post-operative morbidity and mortality. The aim of this study was to assess the prognostic significance of sarcopenia in patients undergoing resection for gastric adenocarcinoma with respect to post-operative morbidity and survival. MATERIALS AND METHODS: A retrospective analysis was conducted on a cohort of consecutive patients who underwent surgical resection for gastric adenocarcinoma between 2008 and 2014. Patient demographics, radiological parameters, and pathological data were collected. OsiriX software (Pixmeo) was used to measure skeletal muscle area, which was normalized for height to calculate skeletal muscle index. RESULTS: A total of 56 patients (41 male, 15 female; mean age, 68.4 ± 11.9 years) met the inclusion criteria. Of these, 36% (20 of 56) of the patients were sarcopenic pre-operatively. Both sarcopenic and non-sarcopenic patient groups were equally matched with the exception of weight and body mass index (P=0.036 and 0.001, respectively). Sarcopenia was associated with a decreased overall survival (log-rank P=0.003) and was an adverse prognostic predictor of overall survival in multivariate analysis (hazard ratio, 10.915; P=0.001). Sarcopenia was a predictor of serious in-hospital complications in multivariate analysis (odds ratio, 3.508; P=0.042). CONCLUSIONS: In patients undergoing curative resection for gastric cancer, there was a statistically significant association between sarcopenia and both decreased overall survival and serious post-operative complications. The measurement and reporting of skeletal muscle index on pre-operative computed tomography should be considered.

11.
Eur Radiol ; 28(9): 3669-3675, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29651772

RESUMO

OBJECTIVES: There is potential for high radiation exposure during neurointerventional procedures. Increasing regulatory requirements mandate dose monitoring of patients and staff, and justification of high levels of radiation exposure. This paper demonstrates the potential to use radiation dose-tracking software to establish local diagnostic reference levels. METHODS: Consecutive neurointerventional procedures, performed in a single institution within a one-year period, were retrospectively studied. Dose area product (DAP) data were collected using dose-tracking software and clinical data obtained from a prospectively generated patient treatment database. RESULTS: Two hundred and sixty-four procedures met the selection criteria. Median DAP was 100 Gy.cm2 for aneurysm coiling procedures, 259 Gy.cm2 for arteriovenous malformation (AVM) embolisation procedures, 87 Gy.cm2 for stroke thrombolysis/thrombectomy, and 74 Gy.cm2 for four-vessel angiography. One hundred and nine aneurysm coiling procedures were further studied. Six significant variables were assessed using stepwise regression analysis to determine effect on DAP. Aneurysm location (anterior vs posterior circulation) had the single biggest effect (p = 0.004). CONCLUSIONS: This paper confirms variable radiation exposures during neurointerventional procedures. The 75th percentile (used to define diagnostic reference levels) of DAP measurements represents a reasonable guidance metric for monitoring purposes. Results indicate that aneurysm location has the greatest impact on dose during coiling procedures and that anterior and posterior circulation coiling procedures should have separate diagnostic reference levels. KEY POINTS: • Dose-tracking software is useful for monitoring patient radiation dose during neurointerventional procedures • This paper provides a template for methodology applicable to any interventional suite • Local diagnostic reference levels were defined by using the 75th percentile of DAP as per International Commission on Radiological Protection recommendations • Aneurysm location is the biggest determinant of radiation dose during coiling procedures. • Anterior and posterior circulation coiling procedures should have separate diagnostic reference levels.


Assuntos
Transtornos Cerebrovasculares/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Monitoramento de Radiação/métodos , Radiografia Intervencionista , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos Cerebrovasculares/terapia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Software , Adulto Jovem
12.
J Med Imaging Radiat Oncol ; 62(5): 625-633, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29656596

RESUMO

INTRODUCTION: Cadaveric studies provide a means of safely assessing new technologies and optimizing scanning prior to clinical validation. Reducing radiation exposure in a clinical setting can entail incremental dose reductions to avoid missing important clinical findings. The use of cadavers allows assessment of the impact of more substantial dose reductions on image quality. Our aim was to identify a suitable low-dose abdominopelvic CT protocol for subsequent clinical validation. METHODS: Five human cadavers were scanned at one conventional dose and three low-dose settings. All scans were reconstructed using three different reconstruction algorithms: filtered back projection (FBP), hybrid iterative reconstruction (60% FBP and 40% adaptive statistical iterative reconstruction (ASIR40)), and model-based iterative reconstruction (MBIR). Two readers rated the image quality both quantitatively and qualitatively. RESULTS: Model-based iterative reconstruction images had significantly better objective image noise and higher qualitative scores compared with both FBP and ASIR40 images at all dose levels. The greatest absolute noise reduction, between MBIR and FBP, of 34.3 HU (equating to a 68% reduction) was at the lowest dose level. MBIR reduced image noise and improved image quality even in CT images acquired with a mean radiation dose reduction of 62% compared with conventional dose studies reconstructed with ASIR40, with lower levels of objective image noise, superior diagnostic acceptability and contrast resolution, and comparable subjective image noise and streak artefact scores. CONCLUSION: This cadaveric study demonstrates that MBIR reduces image noise and improves image quality in abdominopelvic CT images acquired with dose reductions of up to 62%.


Assuntos
Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Cadáver , Humanos
13.
Insights Imaging ; 9(1): 9-16, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29063481

RESUMO

OBJECTIVES: We designed a prospective study to investigate the in-vivo relationship between abdominal body composition and radiation exposure to determine the strongest body composition predictor of dose length product (DLP) at CT. METHODS: Following institutional review board approval, quantitative analysis was performed prospectively on 239 consecutive patients who underwent abdominopelvic CT. DLP, BMI, volumes of abdominal adipose tissue, muscle, bone and solid organs were recorded. RESULTS: All measured body composition parameters correlated positively with DLP. Linear regression (R2 = 0.77) revealed that total adipose volume was the strongest predictor of radiation exposure [B (95% CI) = 0.027(0.024-0.030), t=23.068, p < 0.001]. Stepwise linear regression using DLP as the dependent and BMI and total adipose tissue as independent variables demonstrated that total adipose tissue is more predictive of DLP than BMI [B (95% CI) = 16.045 (11.337-20.752), t=6.681, p < 0.001]. CONCLUSIONS: The volume of adipose tissue was the strongest predictor of radiation exposure in our cohort. MAIN MESSAGE: • Individual body composition variables correlate with DLP at abdominopelvic CT. • Total abdominal adipose tissue is the strongest predictor of radiation exposure. • Muscle volume is also a significant but weaker predictor of DLP.

14.
Chest ; 153(2): 395-403, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29037527

RESUMO

BACKGROUND: Ivacaftor produces significant clinical benefit in patients with cystic fibrosis (CF) with the G551D mutation. Prevalence of this mutation at the Cork CF Centre is 23%. This study assessed the impact of cystic fibrosis transmembrane conductance regulator modulation on multiple modalities of patient assessment. METHODS: Thirty-three patients with the G551D mutation were assessed at baseline and prospectively every 3 months for 1 year after initiation of ivacaftor. Change in ultra-low-dose chest CT scans, blood inflammatory mediators, and the sputum microbiome were assessed. RESULTS: Significant improvements in FEV1, BMI, and sweat chloride levels were observed post-ivacaftor treatment. Improvement in ultra-low-dose CT imaging scores were observed after treatment, with significant mean reductions in total Bhalla score (P < .01), peribronchial thickening (P = .035), and extent of mucous plugging (P < .001). Reductions in circulating inflammatory markers, including interleukin (IL)-1ß, IL-6, and IL-8 were demonstrated. There was a 30% reduction in the relative abundance of Pseudomonas species and an increase in the relative abundance of bacteria associated with more stable community structures. Posttreatment community richness increased significantly (P = .03). CONCLUSIONS: Early and sustained improvements on ultra-low-dose CT scores suggest it may be a useful method of evaluating treatment response. It paralleled improvement in symptoms, circulating inflammatory markers, and changes in the lung microbiota.


Assuntos
Aminofenóis/uso terapêutico , Agonistas dos Canais de Cloreto/uso terapêutico , Fibrose Cística/tratamento farmacológico , Quinolonas/uso terapêutico , Adolescente , Adulto , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/genética , Fibrose Cística/fisiopatologia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Estudos Prospectivos , Radiografia Torácica/métodos , Saliva/microbiologia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
15.
J Am Coll Radiol ; 15(1 Pt A): 11-18, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29079250

RESUMO

OBJECTIVES: Our goal was to ascertain the quality of health information related to CT radiation exposure using a simulated Internet search and from incident information that may be available during day-to-day Internet usage. METHODS: We entered 14 terms relating to information on CT dose into the most commonly used Internet search engine and analyzed the first 100 web page results for each. A Rich Search Site (RSS) feed search was also used to evaluate incidental information over a 12-week period in 2014. Each web page was classified as being "completely accurate," "somewhat accurate," or "inaccurate." RESULTS: Of 1,400 web pages, 290 were relevant and accessible. We deemed 12.8% of these pages as inaccurate and 67.2% of pages as completely accurate. The highest proportion of web pages was from media sources, which, along with discussion forums, commercial websites, and blogs, were found to have proportionally the largest amount of inaccurate information. Of 1,943 posts, 136 (7.0%) identified by the RSS were relevant, 9.6% were deemed inaccurate, and only 29.9% were deemed completely accurate. The results of our simulated query highlight the importance of public education regarding Internet usage when researching topics relating to radiation exposure associated with CT.


Assuntos
Internet , Doses de Radiação , Tomografia Computadorizada por Raios X , Educação em Saúde , Humanos , Ferramenta de Busca
16.
J Med Imaging Radiat Oncol ; 61(2): 190-196, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27739229

RESUMO

INTRODUCTION: We assess the ability of low-dose hybrid iterative reconstruction (IR) and 'pure' model-based IR (MBIR) images to maintain accurate Hounsfield unit (HU)-determined tissue characterization. METHODS: Standard-protocol (SP) and low-dose modified-protocol (MP) CTs were contemporaneously acquired in 34 Crohn's disease patients referred for CT. SP image reconstruction was via the manufacturer's recommendations (60% FBP, filtered back projection; 40% ASiR, Adaptive Statistical iterative Reconstruction; SP-ASiR40). MP data sets underwent four reconstructions (100% FBP; 40% ASiR; 70% ASiR; MBIR). Three observers measured tissue volumes using HU thresholds for fat, soft tissue and bone/contrast on each data set. Analysis was via SPSS. RESULTS: Inter-observer agreement was strong for 1530 datapoints (rs > 0.9). MP-MBIR tissue volume measurement was superior to other MP reconstructions and closely correlated with the reference SP-ASiR40 images for all tissue types. MP-MBIR superiority was most marked for fat volume calculation - close SP-ASiR40 and MP-MBIR Bland-Altman plot correlation was seen with the lowest average difference (336 cm3 ) when compared with other MP reconstructions. CONCLUSIONS: Hounsfield unit-determined tissue volume calculations from MP-MBIR images resulted in values comparable to SP-ASiR40 calculations and values that are superior to MP-ASiR images. Accuracy of estimation of volume of tissues (e.g. fat) using segmentation software on low-dose CT images appears optimal when reconstructed with pure IR.


Assuntos
Doença de Crohn/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Densidade Óssea , Meios de Contraste , Diatrizoato de Meglumina , Feminino , Humanos , Iohexol , Masculino , Estudos Prospectivos , Exposição à Radiação , Reprodutibilidade dos Testes
17.
World J Radiol ; 8(4): 331-41, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-27158420

RESUMO

Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

18.
World J Radiol ; 8(4): 419-27, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-27158429

RESUMO

AIM: To quantify cumulative effective dose of intensive care unit (ICU) patients attributable to diagnostic imaging. METHODS: This was a prospective, interdisciplinary study conducted in the ICU of a large tertiary referral and level 1 trauma center. Demographic and clinical data including age, gender, date of ICU admission, primary reason for ICU admission, APACHE II score, length of stay, number of days intubated, date of death or discharge, and re-admission data was collected on all patients admitted over a 1-year period. The overall radiation exposure was quantified by the cumulative effective radiation dose (CED) in millisieverts (mSv) and calculated using reference effective doses published by the United Kingdom National Radiation Protection Board. Pediatric patients were selected for subgroup-analysis. RESULTS: A total of 2737 studies were performed in 421 patients. The total CED was 1704 mSv with a median CED of 1.5 mSv (IQR 0.04-6.6 mSv). Total CED in pediatric patients was 74.6 mSv with a median CED of 0.07 mSv (IQR 0.01-4.7 mSv). Chest radiography was the most commonly performed examination accounting for 83% of all studies but only 2.7% of total CED. Computed tomography (CT) accounted for 16% of all studies performed and contributed 97% of total CED. Trauma patients received a statistically significant higher dose [median CED 7.7 mSv (IQR 3.5-13.8 mSv)] than medical [median CED 1.4 mSv (IQR 0.05-5.4 mSv)] and surgical [median CED 1.6 mSv (IQR 0.04-7.5 mSv)] patients. Length of stay in ICU [OR = 1.12 (95%CI: 1.079-1.157)] was identified as an independent predictor of receiving a CED greater than 15 mSv. CONCLUSION: Trauma patients and patients with extended ICU admission times are at increased risk of higher CEDs. CED should be minimized where feasible, especially in young patients.

19.
Eur J Radiol Open ; 3: 38-45, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27069978

RESUMO

PURPOSE: We examine the performance of pure model-based iterative reconstruction with reduced-dose CT in follow-up of patients with early-stage testicular cancer. METHODS: Sixteen patients (mean age 35.6 ± 7.4 years) with stage I or II testicular cancer underwent conventional dose (CD) and low-dose (LD) CT acquisition during CT surveillance. LD data was reconstructed with model-based iterative reconstruction (LD-MBIR). Datasets were objectively and subjectively analysed at 8 anatomical levels. Two blinded clinical reads were compared to gold-standard assessment for diagnostic accuracy. RESULTS: Mean radiation dose reduction of 67.1% was recorded. Mean dose measurements for LD-MBIR were: thorax - 66 ± 11 mGy cm (DLP), 1.0 ± 0.2 mSv (ED), 2.0 ± 0.4 mGy (SSDE); abdominopelvic - 128 ± 38 mGy cm (DLP), 1.9 ± 0.6 mSv (ED), 3.0 ± 0.6 mGy (SSDE). Objective noise and signal-to-noise ratio values were comparable between the CD and LD-MBIR images. LD-MBIR images were superior (p < 0.001) with regard to subjective noise, streak artefact, 2-plane contrast resolution, 2-plane spatial resolution and diagnostic acceptability. All patients were correctly categorised as positive, indeterminate or negative for metastatic disease by 2 readers on LD-MBIR and CD datasets. CONCLUSIONS: MBIR facilitated a 67% reduction in radiation dose whilst producing images that were comparable or superior to conventional dose studies without loss of diagnostic utility.

20.
AJR Am J Roentgenol ; 206(3): 448-54, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26901001

RESUMO

1. CT is superior to pulmonary function tests and chest radiography for the assessment and monitoring of cystic fibrosis (CF)-related lung disease and, also, of pediatric bronchiectasis not caused by CF (hereafter referred to as non-CF bronchiectasis). 2. Low-dose CT protocols that impart radiation doses similar to those used in chest radiography are feasible for the surveillance of patients with bronchiectasis. 3. Chest radiography is still most commonly used as the first-line imaging examination of choice for the assessment of acute complications related to bronchiectasis. 4. Pulmonary MRI, with or without the use of inhaled hyperpolarized gas, can be performed to obtain functional information, and, in dedicated centers, it may yield imaging results comparable to those obtained by CT. 5. Gastrointestinal and pancreaticobiliary manifestations of CF are observed with greater frequency in adults, because of increased life expectancy.


Assuntos
Bronquiectasia/diagnóstico , Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Bronquiectasia/diagnóstico por imagem , Criança , Fibrose Cística/diagnóstico , Fibrose Cística/fisiopatologia , Humanos , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Testes de Função Respiratória , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA