1.
Pediatr Hematol Oncol ; 16(6): 561-4, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10599098

RESUMO

Purpura fulminans usually consists of large, often symmetrical, spreading ecchymosis, which may later develop into extensive areas of skin necrosis and peripheral gangrene. Postinfectious purpura fulminans associated with an autoantibody directed against protein S has been described. The interaction and the contribution of recently described mutations such as factor V Leiden and prothrombin G20210A to the development and progression of postinfectious purpura fulminans and venous thrombosis is not known. The authors describe a patient heterozygous for prothrombin G20210A who developed purpura fulminans and extensive venous thrombosis secondary to acquired protein S deficiency.


Assuntos
Vasculite por IgA/etiologia , Deficiência de Proteína S/complicações , Deficiência de Proteína S/imunologia , Protrombina/efeitos adversos , Protrombina/genética , Autoanticorpos/efeitos adversos , Autoanticorpos/sangue , Pré-Escolar , Heterozigoto , Humanos , Vasculite por IgA/genética , Vasculite por IgA/imunologia , Masculino , Mutação de Sentido Incorreto , Deficiência de Proteína S/diagnóstico , Trombose Venosa/etiologia , Trombose Venosa/terapia
2.
Crit Care Med ; 19(11): 1370-3, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1935156

RESUMO

OBJECTIVE: To investigate: a) the relationship between humidifier temperature and inspired gas humidity and b) the effect of insulating the inspiratory tube on "rainout" (condensate). DESIGN: Observational study. SETTING: Regional neonatal unit in a university hospital. PATIENTS: Forty-eight infants receiving assisted ventilation, of whom 31 infants were nursed in incubators and 17 under radiant heaters. MEASUREMENTS AND MAIN RESULTS: Despite always maintaining humidifier temperature greater than 34.7 degrees C, inspired gas humidity decreased below the American National Standards Institution minimum of 30 mg H2O/L on 35 of 479 occasions. At a humidifier temperature of 36 degrees C, inspired gas humidity varied between 17 and 43 mg H2O/L. In incubators set at a temperature of 34.1 +/- 1.3 (SD) degrees C, inspired gas humidity was linearly related to humidifier temperature, but with wide scatter (p less than .001, r2 = .28). In cooler incubators set at 32.9 +/- 1.8 degrees C, inspired gas humidity varied inversely with humidifier temperature. This variation was attributed to condensate due to inspired gas cooling within the incubator. Insulation of the inspiratory tubing reduced condensate by only 15%. CONCLUSIONS: Inspired gas humidity cannot be predicted reliably from humidifier temperature. Accurate control will require a new generation of humidifiers that measure inspired gas humidity.


Assuntos
Umidade , Incubadoras para Lactentes/normas , Temperatura , Desenho de Equipamento , Humanos , Recém-Nascido , Terapia Intensiva Neonatal/métodos , Modelos Lineares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA