Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Ear Hear ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38915137

RESUMO

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

2.
Otol Neurotol ; 45(4): e315-e321, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38478410

RESUMO

INTRODUCTION: Preservation of residual hearing after cochlear implantation allows for electroacoustic stimulation, which leads to better music appreciation, noise localization, and speech comprehension in noisy environments. Real-time intraoperative electrocochleography (rt-ECochG) monitoring has shown promise in improving residual hearing rates. Four-point impedance (4PI) is being explored as a potential biomarker in cochlear implantation that has been associated with fibrotic tissue response, hearing loss, and dizziness. In this study, we explore whether monitoring both rt-ECochG intraoperatively and postoperative 4PI improves predictions of the preservation of residual hearing. METHODS: This was a prospective cohort study. Adults with residual acoustic hearing underwent cochlear implantation with intraoperative intracochlear electrocochleography (ECochG) monitoring. The surgeon responded to a drop in ECochG signal amplitude of greater than 30% by a standardized manipulation of the electrode with the aim of restoring the ECochG. At the end of the procedure, the ECochG signal was categorized as being maintained or having dropped more than 30%. 4PI was measured on 1 day, 1 week, and 1 and 3 months after cochlear implantation. Residual hearing was measured by routine pure-tone audiogram at 3 months postoperatively. The ECochG category and 4PI impedance values were entered as factors in a multiple linear regression predicting the protection of residual hearing. RESULTS: Twenty-six patients were recruited. Rt-ECochG significantly predicted residual hearing at 3 months (t test; mean difference, 37.7%; p = 0.002). Inclusion of both 1-day or 3-month 4PI in a multiple linear regression with rt-ECochG markedly improved upon correlations with residual hearing compared with the rt-ECochG-only model (rt-ECochG and 1-d 4PI model, R2 = 0.67; rt-ECochG and 3-mo 4PI model, R2 = 0.72; rt-ECochG-only model, R2 = 0.33). CONCLUSIONS: Both rt-ECochG and 4PI predict preservation of residual hearing after cochlear implantation. These findings suggest that the biological response of the cochlea to implantation, as reflected in 4PI, is an important determinant of residual hearing, independent of the acute effects on hearing during implant surgery seen with rt-ECochG. We speculate that 4PI relates to inflammation 1 day after implantation and fibrosis at 3 months.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Humanos , Implante Coclear/métodos , Estudos Prospectivos , Impedância Elétrica , Cóclea/cirurgia , Audição , Audiometria de Resposta Evocada/métodos , Biomarcadores
3.
Otol Neurotol ; 45(3): 238-244, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238914

RESUMO

BACKGROUND: The shape and position of cochlear implant electrodes could potentially influence speech perception, as this determines the proximity of implant electrodes to the spiral ganglion. However, the literature to date reveals no consistent association between speech perception and either the proximity of electrode to the medial cochlear wall or the depth of insertion. These relationships were explored in a group of implant recipients receiving the same precurved electrode. METHODS: This was a retrospective study of adults who underwent cochlear implantation with Cochlear Ltd.'s Slim Perimodiolar electrode at the Royal Victorian Eye and Ear Hospital between 2015 and 2018 (n = 52). Postoperative images were obtained using cone beam computed tomography (CBCT) and analyzed by multi-planar reconstruction to identify the position of the electrode contacts within the cochlea, including estimates of the proximity of the electrodes to the medial cochlear wall or modiolus and the angular depth of insertion. Consonant-vowel-consonant (CVC) monosyllabic phonemes were determined preoperatively, and at 3 and 12 months postoperatively. Electrically evoked compound action potential (ECAP) thresholds and impedance were measured from the implant array immediately after implantation. The relationships between electrode position and speech perception, electrode impedance, and ECAP threshold were an analyzed by Pearson correlation. RESULTS: Age had a negative impact on speech perception at 3 months but not 12 months. None of the electrode-wide measures of proximity between electrode contacts and the modiolus, nor measures of proximity to the medial cochlear wall, nor the angular depth of insertion of the most apical electrode correlated with speech perception. However, there was a moderate correlation between speech perception and the position of the most basal electrode contacts; poorer speech perception was associated with a greater distance to the modiolus. ECAP thresholds were inversely related to the distance between electrode contacts and the modiolus, but there was no clear association between this distance and impedance. CONCLUSIONS: Speech perception was significantly affected by the proximity of the most basal electrodes to the modiolus, suggesting that positioning of these electrodes may be important for optimizing speech perception. ECAP thresholds might provide an indication of this proximity, allowing for its optimization during surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Humanos , Lactente , Implante Coclear/métodos , Estudos Retrospectivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Potenciais Evocados
4.
Laryngoscope ; 134(3): 1410-1416, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37694764

RESUMO

INTRODUCTION: Intraoperative trauma leading to bleeding during cochlear implantation negatively impacts residual hearing of cochlear implant recipients. There are no clinical protocols for the removal of blood during implantation, to reduce the consequential effects such as inflammation and fibrosis which adversely affect cochlear health and residual hearing. This preclinical study investigated the implementation of an intra-cochlear flushing protocol for the removal of blood. METHODS: Three groups of guinea pigs were studied for 28 days after cochlear implantation; cochlear implant-only (control group); cochlear implant with blood injected into the cochlea (blood group); and cochlear implant, blood injection, and flushing of the blood from the cochlea intraoperatively (flush group). Auditory brainstem responses (ABRs) in addition to tissue response volumes were analyzed and compared between groups. RESULTS: After implantation, the blood group exhibited the highest ABR thresholds when compared to the control and flush group, particularly in the high frequencies. On the final day, the control and blood group had similar ABR thresholds across all frequencies tested, whereas the flush group had the lowest thresholds, significantly lower at 24 kHz than the blood and control group. Analysis of the tissue response showed the flush group had significantly lower tissue responses in the basal half of the array when compared with the blood and control group. CONCLUSIONS: Flushing intra-cochlear blood during surgery resulted in better auditory function and reduced subsequent fibrosis in the basal region of the cochlea. This finding prompts the implementation of a flushing protocol in clinical cochlear implantation. LEVEL OF EVIDENCE: N/A Laryngoscope, 134:1410-1416, 2024.


Assuntos
Antígenos de Grupos Sanguíneos , Implante Coclear , Implantes Cocleares , Animais , Cobaias , Implante Coclear/métodos , Cóclea/patologia , Fibrose , Potenciais Evocados Auditivos do Tronco Encefálico , Limiar Auditivo
5.
Otol Neurotol ; 45(1): 36-45, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085760

RESUMO

HYPOTHESIS: Gross electrode movements detected with intraoperative, real-time X-ray fluoroscopy will correlate with fluctuations in cochlear output, as measured with intraoperative electrocochleography (ECochG). BACKGROUND: Indications for cochlear implantation (CI) are expanding to include patients with residual hearing; however, implant recipients often lose residual hearing after CI. The objective of this study was to identify probable traumatic events during implantation by combining electrophysiological monitoring of cochlear function with simultaneous X-ray monitoring. The surgical timing of these apparently traumatic events was then investigated. METHODS: For 19 adult patients (21 surgeries, 2 bilateral), the ECochG responses were measured during implantation of a cochlear nucleus slim modiolar electrode (CI532/CI632, Cochlear Ltd Australia Nucleus slim modiolar). Simultaneous fluoroscopy was performed, as well as a postoperative cone-beam computed tomography (CT) scan. For all patients, pre- and postoperative audiograms were recorded up to 1 year after surgery to record the loss of residual hearing. RESULTS: Electrode insertions for 21 surgeries were successfully monitored. A drop in ECochG response was significantly correlated with reduced hearing preservation compared with patients with preserved responses throughout. Drops in the ECochG response were measured to occur during insertion, because of movement of the array after insertion was complete, including while sealing of the electrode array at the round window or coiling of the array lead within the mastoid cavity. In some patients, a reduction in cochlear output, resulting in poor ECochG response, was inferred to occur before the beginning of implantation. CONCLUSION: The combination of perioperative ECochG measurements, microscope video, fluoroscopy, and postoperative CT scan may inform on what causes the loss of residual hearing after implantation. These findings will be used to improve the surgical procedure in future.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Humanos , Audiometria de Resposta Evocada/métodos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Cóclea/lesões , Implante Coclear/métodos , Fluoroscopia
6.
Acta Otolaryngol ; 143(8): 647-654, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37603289

RESUMO

BACKGROUND: Systemically administered steroids are widely utilised for hearing preservation therapies. More recently, steroids have been administered to achieve hearing protection after cochlear implant surgery. Currently there is a lack of understanding as to which administration route offers most therapeutic efficacy, local or systemic administration. Paramount to this are observations in animal studies that systemic administration following implantation offers hearing protection and reduced cochlear fibrosis, despite observations that perilymphatic levels are up to 10-fold higher after local administration in non-implanted cochleae. AIMS/OBJECTIVES: This paper explores the impact that cochlear implantation and associated acute inflammation has on steroid distribution and uptake following systemic administration of dexamethasone. MATERIAL AND METHODS: Eight guinea pigs received systemic dexamethasone 60 min prior to cochlear implantation. Implanted and contralateral non-implanted cochlea were harvested for tissue immunohistochemistry and detection of dexamethasone. RESULTS: Cochleostomy with scala tympani implantation resulted in a significant increase in cochlear dexamethasone signal. This was most notable at the organ of Corti, stria vascularis, and blood product in the scala tympani. CONCLUSIONS AND SIGNIFICANCE: This study demonstrates that the inner ear distribution of systemically administered steroids is enhanced following surgery for cochlear implantation and provides rationale for systemic perioperative steroids in hearing preservation surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Animais , Cobaias , Cóclea/cirurgia , Esteroides , Dexametasona
7.
Ear Hear ; 44(4): 710-720, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36550618

RESUMO

OBJECTIVES: Different patterns of electrocochleographic responses along the electrode array after insertion of the cochlear implant electrode array have been described. However, the implications of these patterns remain unclear. Therefore, the aim of the study was to correlate different peri- and postoperative electrocochleographic patterns with four-point impedance measurements and preservation of residual hearing. DESIGN: Thirty-nine subjects with residual low-frequency hearing which were implanted with a slim-straight electrode array could prospectively be included. Intracochlear electrocochleographic recordings and four-point impedance measurements along the 22 electrodes of the array (EL, most apical EL22) were conducted immediately after complete insertion and 3 months after surgery. Hearing preservation was assessed after 3 months. RESULTS: In perioperative electrocochleographic recordings, 22 subjects (56%) showed the largest amplitude around the tip of the electrode array (apical-peak, AP, EL20 or EL22), whereas 17 subjects (44%) exhibited a maximum amplitude in more basal regions (mid-peak, MP, EL18 or lower). At 3 months, in six subjects with an AP pattern perioperatively, the location of the largest electrocochleographic response had shifted basally (apical-to-mid-peak, AP-MP). Latency was analyzed along the electrode array when this could be discerned. This was the case in 68 peri- and postoperative recordings (87% of all recordings, n = 78). The latency increased with increasing insertion depth in AP recordings (n = 38, median of EL with maximum latency shift = EL21). In MP recordings (n = 30), the maximum latency shift was detectable more basally (median EL12, p < 0.001). Four-point impedance measurements were available at both time points in 90% (n = 35) of all subjects. At the 3-month time point, recordings revealed lower impedances in the AP group (n = 15, mean = 222 Ω, SD = 63) than in the MP (n = 14, mean = 295 Ω, SD= 7 6) and AP-MP groups (n = 6, mean = 234 Ω, SD = 129; AP versus MP p = 0.026, AP versus AP-MP p = 0.023, MP versus AP-MP p > 0.999). The amplitudes of perioperative AP recordings showed a correlation with preoperative hearing thresholds ( r2 =0.351, p = 0.004). No such correlation was detectable in MP recordings ( r2 = 0.033, p = 0.484). Audiograms were available at both time points in 97% (n = 38) of all subjects. The mean postoperative hearing loss in the AP group was 13 dB (n = 16, SD = 9). A significantly larger hearing loss was detectable in the MP and AP-MP groups with 28 (n = 17, SD = 10) and 35 dB (n = 6, SD = 13), respectively (AP versus MP p = 0.002, AP versus AP-MP p = 0.002, MP versus AP-MP p = 0.926). CONCLUSION: MP and AP-MP response patterns of the electrocochleographic responses along the electrode array after cochlear implantation are correlated with higher four-point impedances and poorer postoperative hearing compared to AP response patterns. The higher impedances suggest that MP and AP-MP patterns are associated with increased intracochlear fibrosis.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Humanos , Impedância Elétrica , Perda Auditiva/cirurgia , Cóclea/cirurgia , Surdez/cirurgia
8.
Eur Arch Otorhinolaryngol ; 280(3): 947-962, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36301356

RESUMO

The objective of this systematic review is to compare the diagnostic value of endolymphatic hydrops (EH) magnetic resonance imaging (MRI) with audiovestibular function tests, including electro cochleography (ECochG), cervical vestibular evoked myogenic potential (cVEMP) and caloric tests for the diagnosis of definite Meniere's disease (DMD). An electronic search was performed in the PubMed, Embase and Cochrane databases in August 2022. Original studies which reported the efficacy of gadolinium MRI for diagnosis of DMD were compared with ECochG, cVEMP and caloric tests from 2007 to 2022 published in English. Two reviewers extracted the methodology and results of MRI and functional tests, assessing them independently. A modified version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used for the assessment of the quality and the risk of bias of each study. The proportion of DMD cases diagnosed by MRI hydrops vs corresponding functional tests were calculated and the relationship between MRI and functional tests were evaluated using the Cohen's Kappa test. Concerning the MRI, the proportion diagnostic of DMD was 0.67 by cochlear EH and 0.80-0.82 by vestibular EH. Regarding the functional test, the propotiojn diagnostic of DMD was 0.48 by ECochG, 0.76 by cVEMP and 0.65 by caloric test. The findings of this systematic review were that the vestibular EH on imaging most effectively assisted in diagnosing DMD. Among the functional tests, cVEMP was the second most effective test. The agreement between imaging and cVEMP was moderate (0.44), indicating a gap between the patients identified by the imaging and functional tests based on the relatively small number of patients.


Assuntos
Hidropisia Endolinfática , Potenciais Evocados Miogênicos Vestibulares , Humanos , Testes Calóricos , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Audiometria de Resposta Evocada , Hidropisia Endolinfática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Edema
9.
Otol Neurotol ; 43(10): e1107-e1114, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36351225

RESUMO

OBJECTIVE: Monitor four-point impedance in cochlear implant recipients over time and determine if implant type, surgical approach, and electrode positioning affected impedance measurements. STUDY DESIGN: Prospective observational. SETTING: Hospital. PATIENTS: Adult cochlear implant recipients implanted with a perimodiolar or lateral wall cochlear implant. MAIN OUTCOME MEASURES: Mean values for four-point impedances were calculated for all electrode contacts at perioperative and 3 months after surgery. Linear mixed models were applied to the impedance data to compare between implant types and time points. The angular insertion depth and electrode position relative to the medial and lateral wall, commonly termed the Intracochlear Position Index (ICPI), were collected and compared with impedance measurements. RESULTS: Perioperatively, the four-point impedance was similar between implant types, with perimodiolar implants having marginally higher impedance values in the basal region. At 3 months after surgery, impedances significantly increased in the basal half of the electrode array for both implants, with higher impedance values for CI532 implants. There were no significant differences in insertion angle depth between implant types. The ICPI values for the seven most basal electrodes were similar for both implants; however, CI532 arrays were significantly more medially placed along the remaining apical portion of the array, which is expected. ICPI values did not correlate with impedance measurements for either implant. CONCLUSIONS: Four-point impedance increases at 3 months after surgery may reflect fibrous tissue formation after cochlear implantation. The higher impedance values in perimodiolar implants may reflect a more extensive fibrosis formation as a result of surgical approaches used, requiring drilling of the cochlea bone.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Humanos , Impedância Elétrica , Cóclea/cirurgia , Eletrodos Implantados
10.
Otol Neurotol ; 43(7): e730-e737, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35861642

RESUMO

OBJECTIVE: Monitoring four-point impedance changes after cochlear implantation with comparison to conventional impedance measurements. Four-point impedance provides information regarding the bulk biological environment surrounding the electrode array, which is not discernible with conventional impedances. STUDY DESIGN: Prospective observational. SETTING: Hospital. PATIENTS: Adult cochlear implant recipients with no measurable hearing before implantation and implanted with a perimodiolar cochlear implant. MAIN OUTCOME MEASURES: Mean values for four-point and common ground impedances were calculated for all electrode contacts at intra-operative, 1 day, 1 week, 4 to 6 weeks, and 3 months post implantation. Linear mixed models were applied to the impedance data to compare between impedances and time points. Furthermore, patients were divided into groups dependent on the normalized change in four-point impedance from intra-operative to 1 day post-operative. The normalized change was then calculated for all other time points and compared across the two groups. RESULTS: Significant increases in four-point impedance occurred 1 day and 3 months after surgery, particularly in the basal half of the array. Four-point impedance at 1 day was highly predictive of four-point impedance at 3 months. Four-point impedance at the other time points showed marginal or no increases from intra-operative. Patients with an average increase higher than 10% in four-point impedance from intra-operative to 1 day, had significantly higher values at 3 months ( p = 0.012). These patterns were not observed in common ground impedance. CONCLUSION: This is the first study to report increases in four-point impedance within 24 hours of cochlear implantation. The increases at 1 day and 3 months align with the natural timeline of an acute and chronic inflammatory responses.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Impedância Elétrica , Testes Auditivos , Humanos , Período Pós-Operatório
11.
PLoS One ; 17(7): e0269187, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35834542

RESUMO

Cochlear implants (CIs) provide an opportunity for the hearing impaired to perceive sound through electrical stimulation of the hearing (cochlear) nerve. However, there is a high risk of losing a patient's natural hearing during CI surgery, which has been shown to reduce speech perception in noisy environments as well as music appreciation. This is a major barrier to the adoption of CIs by the hearing impaired. Electrocochleography (ECochG) has been used to detect intra-operative trauma that may lead to loss of natural hearing. There is early evidence that ECochG can enable early intervention to save natural hearing of the patient. However, detection of trauma by observing changes in the ECochG response is typically carried out by a human expert. Here, we discuss a method of automating the analysis of cochlear responses during CI surgery. We establish, using historical patient data, that the proposed method is highly accurate (∼94% and ∼95% for sensitivity and specificity respectively) when compared to a human expert. The automation of real-time cochlear response analysis is expected to improve the scalability of ECochG and improve patient safety.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Audiometria de Resposta Evocada/métodos , Cóclea/cirurgia , Implante Coclear/métodos , Audição , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Humanos
12.
Otol Neurotol ; 43(6): 685-693, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35761462

RESUMO

BACKGROUND: Endolymphatic hydrops (EH) has been observed in both animal and human cochleae following cochlear implant (CI) surgery. We tested whether EH could be eliminated by administration of mineralocorticoid steroid antagonist spironolactone and explored the electrophysiological consequences of this. METHODS: Sixty-four adult guinea pigs underwent cochlear implantation with a dummy electrode. Animals then survived either 2, 7, or 28 days. Auditory function was monitored by recording electrocochleography from the round window membrane preimplantation, and on the last day of the experiment. Spironolactone or control solution was added to animals' feed for 7 days (if they survived that long) beginning immediately prior to surgery. The presence of EH was determined using thin-sheet laser imaging microscopy. RESULTS: Treatment with spironolactone resulted in significant reduction in EH in the second cochlear turn 7 days postimplantation. In all animals, the compound action potential (CAP) threshold was elevated 2 days postimplantation, but for most frequencies had recovered substantially by 28 days. There was no treatment effect on CAP thresholds. SP/AP ratios were elevated at day 2. The amplitude growth of the CAP did not differ between test and control groups at any time after implantation. CONCLUSIONS: EH can be suppressed by antagonism of mineralocorticoid receptors in the week after cochlear implantation. Reduction in EH did not lead to any change in hearing, and there was no indication of synaptopathy signalled by reduced CAP amplitude at high sound intensities. We found no electrophysiological evidence that EH early after implantation impacts negatively upon preservation of residual hearing.


Assuntos
Implante Coclear , Implantes Cocleares , Hidropisia Endolinfática , Animais , Audiometria de Resposta Evocada , Hidropisia Endolinfática/tratamento farmacológico , Hidropisia Endolinfática/etiologia , Cobaias , Humanos , Espironolactona/farmacologia , Espironolactona/uso terapêutico
13.
Eur Arch Otorhinolaryngol ; 279(10): 4917-4923, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35355112

RESUMO

SETTING: The Eustachian tube plays a vital role in middle ear physiology. There has been evidence that Eustachian tube (ET) and angle are correlated with middle ear function. The measurements of these Eustachian tube features are now made possible with computed tomography and multiplanar reconstruction techniques. However, there has not been a standardised protocol devised to these measurements in limited window cone-beam CT scans of temporal bones. OBJECTIVE: The primary object of the present study is to establish and validate a new landmark in closer proximity to the middle ear that is consistently captured, thereby allowing ET angle and length to be measured from the majority of cone-beam CT scans. Secondarily, the ET anatomies of patients with middle ear dysfunction manifesting as acquired cholesteatoma are analysed with this new method of measurement. METHODS: This study undertook a step-by-step method to first validate the methods of ET measurement with Reid's standard plane, then identifying an alternative landmark, thus a new plane visible on limited window cone-beam CT scans of temporal bones and lastly, validating the application of this new plane in the measurements of ET angle and length. This new method of measurement was coined the Ku-Copson plane and was applied to 30 cochlear implant patients and 30 patients with acquired cholesteatomas. Their ET anatomies were analysed and compared. RESULTS: It was found that the new Ku-Copson mandibular fossa plane was a reliable and accurate plane for the measurement of ET angle and length. Furthermore, it was found that patients with acquired cholesteatomas have statistically significant smaller ET angles and shorter ET lengths when compared with patients with cochlear implants, of normal middle ear function. CONCLUSION: The newly proposed method utilising the right mandibular fossa as an anatomical landmark for ET angles and lengths measurement appears to be viable. The close proximity of this landmark to the middle ear means that it is highly likely to be captured in most cone-beam CT scans of the petrous temporal bones. This enables the retrospective examination ET angles and lengths to be conducted on CB CT scans. This study reports statistically significant difference in ET anatomy in patients with middle ear dysfunction.


Assuntos
Colesteatoma , Tuba Auditiva , Orelha Média/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem
14.
Sensors (Basel) ; 22(2)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35062484

RESUMO

Multi-modal three-dimensional (3-D) image segmentation is used in many medical applications, such as disease diagnosis, treatment planning, and image-guided surgery. Although multi-modal images provide information that no single image modality alone can provide, integrating such information to be used in segmentation is a challenging task. Numerous methods have been introduced to solve the problem of multi-modal medical image segmentation in recent years. In this paper, we propose a solution for the task of brain tumor segmentation. To this end, we first introduce a method of enhancing an existing magnetic resonance imaging (MRI) dataset by generating synthetic computed tomography (CT) images. Then, we discuss a process of systematic optimization of a convolutional neural network (CNN) architecture that uses this enhanced dataset, in order to customize it for our task. Using publicly available datasets, we show that the proposed method outperforms similar existing methods.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
15.
J Vestib Res ; 32(3): 295-304, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34459428

RESUMO

BACKGROUND: Dizziness is a common perioperative complication after cochlear implantation (CI). To date, the exact cause behind this phenomenon remains unclear. There is recent evidence to suggest that otolith function, specifically utricular, may be affected shortly after CI surgery, however whether these changes are related to patient symptoms has not yet been investigated. OBJECTIVE: To determine whether CI surgery and perioperative dizziness is associated with changes in utricular function. METHODS: We performed an observational study on patients undergoing routine CI surgery. Utricular function was assessed using the Subjective Visual Vertical (SVV), and perioperative dizziness was determined using a questionnaire. The study followed patients before surgery and then again 1-day, 1-week and 6-weeks after implantation. RESULTS: Forty-one adult CI recipients participated in the study. The SVV deviated away from the operated ear by an average of 2.17° a day after implantation, 0.889° 1 week and -0.25° 6 weeks after surgery. Dizziness contributed to a tilt of 0.5° away from the implanted ear. These deviations were statistically significant. CONCLUSIONS: CI surgery causes utricular hyperfunction in the operated ear that resolves over 6 weeks. SVV tilts were greater in participants experiencing dizziness, suggesting that utricular hyperfunction may contribute to the dizziness.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Tontura/etiologia , Humanos , Membrana dos Otólitos , Vertigem/complicações
16.
Eur Arch Otorhinolaryngol ; 279(1): 137-147, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33547488

RESUMO

PURPOSE: To provide practical guidance to the operative surgeon by mapping the location, where acceptable straight-line virtual cochlear implant electrode trajectories intersect the facial recess. In addition, to investigate the influence of facial recess preparation, virtual electrode width and surgical approach to the cochlea on these available trajectories. METHODS: The study was performed on imaging data from eight cadaveric temporal bones within the University of Melbourne Virtual Reality (VR) Temporal Bone Surgery Simulator. The facial recess was opened to varying degrees, and acceptable trajectory vectors with varying diameters were calculated for electrode insertions via cochleostomy or round window membrane (RWM). The percentage of acceptable insertion vectors through each location of the facial recess was visually represented using heatmaps. RESULTS: Seven of the eight bones allowed for acceptable vector trajectories via both cochleostomy and RWM approaches. These acceptable trajectories were more likely to lie superiorly within the facial recess for insertion via the round window, and inferiorly for insertion via cochleostomy. Cochleostomy insertions required a greater degree of preparation and skeletonisation of the junction of the facial nerve and chorda tympani within the facial recess. The width of the virtual electrode had only marginal impact on the availability of acceptable trajectories. Heatmaps emphasised the intimate relationship the acceptable trajectories have with the facial nerve and chorda tympani. CONCLUSION: These findings highlight the differences in the acceptable straight-line trajectories for electrodes when implanted via the round window or cochleostomy. There were notable exceptions to both surgical approaches, likely explained by the variation of hook region anatomy. The methodology used in this study holds promise for translation to patient specific surgical planning.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Eletrodos Implantados , Humanos , Janela da Cóclea/cirurgia , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
17.
Otol Neurotol ; 42(8): 1253-1260, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34149030

RESUMO

BACKGROUND: This project investigated the effects of round window membrane (RWM) sealants after surgical incision, with a focus on audiological thresholds, ossicular mechanics, and the impact upon cochlear function and pathology. METHODS: Twenty-eight guinea pigs were randomly allocated to one of three sealant groups (muscle, n = 7; fascia, n = 7, Tisseel, n = 8) or an unsealed control group (n = 6). Preoperative hearing was measured using auditory brainstem responses (ABRs). The ossicular chain and RWM were exposed surgically, and Laser Doppler Vibrometry (LDV) measurements were obtained from the long process of the incus. The RWM was incised then sealed (or left unsealed) according to group. ABR testing and LDV measurements were repeated 4 and 12 weeks after surgery. At 12 weeks all cochleae were harvested. RESULTS: ABR thresholds deteriorated over time in all groups. Overall, group was not statistically significant (p = 0.064). There was no significant effect by group on LDV measurements (p = 0.798). Histopathological analyses of the RWM showed that the fascia group had more extensive fibrosis than other groups (Independent-Samples Median Test, p = 0.001). However, there were minimal differences in the outer hair cell counts between the different intervention groups. CONCLUSIONS: All the interventions appeared to be safe while none affected the cochlear mechanics or hearing thresholds in a statistically significant manner.


Assuntos
Perda Auditiva , Janela da Cóclea , Animais , Cobaias , Cóclea , Potenciais Evocados Auditivos do Tronco Encefálico , Audição , Janela da Cóclea/cirurgia
18.
Otol Neurotol ; 42(8): e1030-e1036, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33859138

RESUMO

OBJECTIVES: Real-time electrocochleography (rt-ECochG) is a method to detect intracochlear potential changes during cochlear implantation (CI). Steep amplitude drops of the cochlear microphonic (CM) signal (so called "ECochG events") have been correlated with worse residual hearing outcomes. However, the sensitivity and specificity of monitoring CM amplitude on its own are too low to use it as a biomarker. The aim of this article was to establish if additional signal components would help to better predict postoperative hearing outcomes. DESIGN AND SETTING: Single-center, prospective cohort study at a tertiary referral hospital. PARTICIPANTS AND INTERVENTIONS: Between 2017 and 2020, we included 73 adult patients receiving a lateral wall cochlear implant electrode. During electrode insertion, rt-ECochG measurements were performed. MAIN OUTCOMES: We calculated a multiple regression analysis for patients with one ECochG event. The dependant variable was the relative acoustic hearing result 4 weeks after surgery. Independent variables were CM latency, a ratio of the auditory nerve neurophonic to the CM (the ANN/CM index) as well as CM signal recovery. RESULTS: The change of the ANN/CM index linearly correlated with acoustic hearing outcomes 4 weeks after surgery. Adding this factor led to a statistically significant increase in the variance accounted for by the regression model. CONCLUSIONS: When monitoring the implantation process with rt-ECochG, prediction of postoperative hearing thresholds is improved by addition of the ANN/CM index to a model that includes CM amplitude fluctuation.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Audiometria de Resposta Evocada , Audição , Humanos , Estudos Prospectivos
19.
Hear Res ; 404: 108224, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33774594

RESUMO

AIM: To assess whether a single, peri-operative, high dose of methylprednisolone can improve the preservation of residual acoustic hearing following cochlear implantation (CI). METHODS: This was a double blinded placebo-controlled trial, performed in a tertiary academic centre. The hypothesis was that methylprednisolone would improve the preservation of hearing, and lower electrode impedances. Adult patients (18-85 years) with hearing at 85 dB or better at 500 Hz in the ear to be implanted were randomly allocated to either treatment (methylprednisolone, 1g administered intravenously upon induction of anaesthesia) or control (normal saline infusion). As per standard clinical practice, all patients received a routine dose of dexamethasone (8 mg intravenously) on induction of anaesthesia. Implantation was undertaken with a slim and flexible lateral wall electrode via the round window. Surgical technique was routine, with adherence to soft surgical principles. The primary outcome was hearing preservation within 20 dB at 500 Hz, 12 months following cochlear implantation. Secondary outcomes included hearing preservation at 6 weeks and 3 months, monopolar electrode impedance, and Consonant-Vowel-Consonant (CVC) Phoneme scores at 3 and 12 months after surgery. RESULTS: Forty-five patients were enrolled into the control group and 48 patients received the steroid. The number of patients achieving hearing preservation at 12 months did not differ significantly between those receiving methylprednisolone treatment and the controls. There were no differences in hearing preservation at any frequency at either 6 weeks or 3 months after implantation. Neither CVC phoneme scores nor electrode impedances differed between the groups. CONCLUSIONS: This paper demonstrates that high-dose local steroid injection at surgery was not effective in preventing a loss of residual hearing, improving speech perception, or lowering electrode impedances. The findings were contrary to the experimental literature, and emerging clinical evidence that steroid elution from implant electrodes influences cochlear biology in humans. We found no evidence to support the widely-held practice of administering intravenous steroids in the perioperative period, in an attempt to preserve residual hearing.


Assuntos
Implante Coclear , Implantes Cocleares , Audição , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Metilprednisolona/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
20.
Clin Otolaryngol ; 46(5): 961-968, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33779051

RESUMO

INTRODUCTION: Cortical mastoidectomy is a core skill that Otolaryngology trainees must gain competency in. Automated competency assessments have the potential to reduce assessment subjectivity and bias, as well as reducing the workload for surgical trainers. OBJECTIVES: This study aimed to develop and validate an automated competency assessment system for cortical mastoidectomy. PARTICIPANTS: Data from 60 participants (Group 1) were used to develop and validate an automated competency assessment system for cortical mastoidectomy. Data from 14 other participants (Group 2) were used to test the generalisability of the automated assessment. DESIGN: Participants drilled cortical mastoidectomies on a virtual reality temporal bone simulator. Procedures were graded by a blinded expert using the previously validated Melbourne Mastoidectomy Scale: a different expert assessed procedures by Groups 1 and 2. Using data from Group 1, simulator metrics were developed to map directly to the individual items of this scale. Metric value thresholds were calculated by comparing automated simulator metric values to expert scores. Binary scores per item were allocated using these thresholds. Validation was performed using random sub-sampling. The generalisability of the method was investigated by performing the automated assessment on mastoidectomies performed by Group 2, and correlating these with scores of a second blinded expert. RESULTS: The automated binary score compared with the expert score per item had an accuracy, sensitivity and specificity of 0.9450, 0.9547 and 0.9343, respectively, for Group 1; and 0.8614, 0.8579 and 0.8654, respectively, for Group 2. There was a strong correlation between the total scores per participant assigned by the expert and calculated by the automatic assessment method for both Group 1 (r = .9144, P < .0001) and Group 2 (r = .7224, P < .0001). CONCLUSION: This study outlines a virtual reality-based method of automated assessment of competency in cortical mastoidectomy, which proved comparable to the assessment provided by human experts.


Assuntos
Competência Clínica , Educação Médica/métodos , Mastoidectomia/educação , Treinamento por Simulação/métodos , Realidade Virtual , Adulto , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA