Resultados 1 - 20 de 113
Filtrar
1.
Lancet Oncol ; 25(7): 879-887, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876123

RESUMO

BACKGROUND: Artificial intelligence (AI) systems can potentially aid the diagnostic pathway of prostate cancer by alleviating the increasing workload, preventing overdiagnosis, and reducing the dependence on experienced radiologists. We aimed to investigate the performance of AI systems at detecting clinically significant prostate cancer on MRI in comparison with radiologists using the Prostate Imaging-Reporting and Data System version 2.1 (PI-RADS 2.1) and the standard of care in multidisciplinary routine practice at scale. METHODS: In this international, paired, non-inferiority, confirmatory study, we trained and externally validated an AI system (developed within an international consortium) for detecting Gleason grade group 2 or greater cancers using a retrospective cohort of 10 207 MRI examinations from 9129 patients. Of these examinations, 9207 cases from three centres (11 sites) based in the Netherlands were used for training and tuning, and 1000 cases from four centres (12 sites) based in the Netherlands and Norway were used for testing. In parallel, we facilitated a multireader, multicase observer study with 62 radiologists (45 centres in 20 countries; median 7 [IQR 5-10] years of experience in reading prostate MRI) using PI-RADS (2.1) on 400 paired MRI examinations from the testing cohort. Primary endpoints were the sensitivity, specificity, and the area under the receiver operating characteristic curve (AUROC) of the AI system in comparison with that of all readers using PI-RADS (2.1) and in comparison with that of the historical radiology readings made during multidisciplinary routine practice (ie, the standard of care with the aid of patient history and peer consultation). Histopathology and at least 3 years (median 5 [IQR 4-6] years) of follow-up were used to establish the reference standard. The statistical analysis plan was prespecified with a primary hypothesis of non-inferiority (considering a margin of 0·05) and a secondary hypothesis of superiority towards the AI system, if non-inferiority was confirmed. This study was registered at ClinicalTrials.gov, NCT05489341. FINDINGS: Of the 10 207 examinations included from Jan 1, 2012, through Dec 31, 2021, 2440 cases had histologically confirmed Gleason grade group 2 or greater prostate cancer. In the subset of 400 testing cases in which the AI system was compared with the radiologists participating in the reader study, the AI system showed a statistically superior and non-inferior AUROC of 0·91 (95% CI 0·87-0·94; p<0·0001), in comparison to the pool of 62 radiologists with an AUROC of 0·86 (0·83-0·89), with a lower boundary of the two-sided 95% Wald CI for the difference in AUROC of 0·02. At the mean PI-RADS 3 or greater operating point of all readers, the AI system detected 6·8% more cases with Gleason grade group 2 or greater cancers at the same specificity (57·7%, 95% CI 51·6-63·3), or 50·4% fewer false-positive results and 20·0% fewer cases with Gleason grade group 1 cancers at the same sensitivity (89·4%, 95% CI 85·3-92·9). In all 1000 testing cases where the AI system was compared with the radiology readings made during multidisciplinary practice, non-inferiority was not confirmed, as the AI system showed lower specificity (68·9% [95% CI 65·3-72·4] vs 69·0% [65·5-72·5]) at the same sensitivity (96·1%, 94·0-98·2) as the PI-RADS 3 or greater operating point. The lower boundary of the two-sided 95% Wald CI for the difference in specificity (-0·04) was greater than the non-inferiority margin (-0·05) and a p value below the significance threshold was reached (p<0·001). INTERPRETATION: An AI system was superior to radiologists using PI-RADS (2.1), on average, at detecting clinically significant prostate cancer and comparable to the standard of care. Such a system shows the potential to be a supportive tool within a primary diagnostic setting, with several associated benefits for patients and radiologists. Prospective validation is needed to test clinical applicability of this system. FUNDING: Health~Holland and EU Horizon 2020.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Neoplasias da Próstata , Radiologistas , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Gradação de Tumores , Países Baixos , Curva ROC
2.
EJNMMI Res ; 14(1): 32, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536511

RESUMO

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients that have bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases. METHODS: For this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified by the most commonly used PET parameter, the maximum tumor voxel normalized by dose and body weight (SUVmax) and also by the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals for SUVmax and SULpeak were used to determine the limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax and SULpeak in 38 bone tumors of the first cohort were 4.3% and 6.7%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and - 16.3% for SUVmax, and 21.2% and - 17.5% for SULpeak. 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification using SULpeak for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria for SULpeak changed the status of 3 patients compared to the standard Positron Emission Tomography Response Criteria in Solid Tumors of ± 30% SULpeak. CONCLUSION: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG SUVmax, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions in these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

3.
J Gastrointest Oncol ; 15(1): 356-367, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38482235

RESUMO

Background: 90Y radioembolization is an established treatment modality for hepatic malignancies. Successful radioembolization requires optimal dose delivery to tumors while minimizing dosages to parenchyma. Post-treatment positron emission tomography (PET)/computed tomography (CT) dosimetry is the established benchmark, whereas PET/magnetic resonance (MR) is an emerging modality. The goal of this study was to assess the intermodality agreement between PET/MR and PET/CT 90Y dosimetry. Methods: In this single-institution study, 18 patients (20 treatment sessions) with a primary or metastatic hepatic malignancy underwent both PET/MR and PET/CT after 90Y radioembolization. Patients were randomized to undergo one modality first, followed by the other. The region of interest was delineated using MR images and tumor and liver dosimetry was calculated. Intermodality agreement was assessed using the Bland-Altman method. A generalized linear model was used to assess the effect of baseline variables on intermodality dose differences. Results: PET/MR underestimated tumor and liver absorbed doses when compared to PET/CT by -3.7% (P=0.042) and -5.8% (P=0.029), respectively. A coverage probability plot demonstrated that 80% and 90% of tumor dose measurements fell within intermodality differences of 11% and 18%, respectively. PET/MR underestimated tumor dose at both low (<1 GBq) and high (>3 GBq) injected activity levels (P<0.001) by -22.3 [standard deviation (SD) =13.5] and -24.3 (SD =18.7), respectively. Conclusions: Although PET/MR significantly underestimated the absorbed dose when compared to PET/CT, the intermodality agreement was high and the degree of underestimation was better than previously reported. Intermodality differences were more pronounced at low and high injected doses. Additional studies are required to assess the clinical implications of these findings.

4.
Res Sq ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38313279

RESUMO

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients with bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases.In this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified as the maximum tumor voxel normalized by dose and body weight (SUVmax) and the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals of SUVmax and SULpeak were used to determine limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax in 38 bone tumors of the first cohort was 4.3%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and -16.3%, respectively. The 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria changed the status of 3 patients compared to standard the standard Positron Emission Tomography Response Criteria in Solid Tumors of ±30% SULpeak. CONCLUSIONS: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG uptake, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions from these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

5.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059633

RESUMO

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Quant Imaging Med Surg ; 13(9): 6193-6204, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37711774

RESUMO

Background: A calibration phantom-based method has been developed for predicting small lung nodule volume measurement bias and precision that is specific to a particular computed tomography (CT) scanner and acquisition protocol. Methods: The approach involves CT scanning a simple reference object with a specific acquisition protocol, analyzing the scan to estimate the fundamental imaging properties of the CT acquisition system, generating numerous simulated images of a target geometry using the fundamental imaging properties, measuring the simulated images with a standard nodule volume segmentation algorithm, and calculating bias and precision performance statistics from the resulting volume measurements. We evaluated the ability of this approach to predict volume measurement bias and precision of Teflon spheres (diameters =4.76, 6.36, and 7.94 mm) placed within an anthropomorphic chest phantom when using 3M Scotch Magic™ tape as the reference object. CT scanning of the spheres was performed with 0.625, 1.25, and 2.5 mm slice thickness and spacing. Results: The study demonstrated good agreement between predicted volumetric performance and observed volume measurement performance for both volumetric measurement bias and precision. The predicted and observed volume mean for all slice thicknesses was found to be 28% and 13% lower on average than the manufactured sphere volume, respectively. When restricted to 0.625 and 1.25 mm slice thickness scans, which are recommended for small lung nodule volume measurement, we found that the difference between predicted and observed volume coefficient of variation was less than 1.0 %. The approach also showed a resilience to varying CT image acquisition protocols, a critical capability when deploying in a real-world clinical setting. Conclusions: This is the first report of a calibration phantom-based method's ability to predict both small lung nodule volume measurement bias and precision. Volume measurement bias and precision for small lung nodules can be predicted using simple low-cost reference objects to estimate fundamental CT image characteristics and modeling and simulation techniques. The approach demonstrates an improved method for predicting task specific, clinically relevant measurement performance using advanced and fully automated image analysis techniques and low-cost reference objects.

7.
J Neurooncol ; 163(3): 647-655, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37341842

RESUMO

PURPOSE: Distinguishing radiation necrosis from tumor progression among patients with brain metastases previously treated with stereotactic radiosurgery represents a common diagnostic challenge. We performed a prospective pilot study to determine whether PET/CT with 18F-fluciclovine, a widely available amino acid PET radiotracer, repurposed intracranially, can accurately diagnose equivocal lesions. METHODS: Adults with brain metastases previously treated with radiosurgery presenting with a follow-up tumor-protocol MRI brain equivocal for radiation necrosis versus tumor progression underwent an 18F-fluciclovine PET/CT of the brain within 30 days. The reference standard for final diagnosis consisted of clinical follow-up until multidisciplinary consensus or tissue confirmation. RESULTS: Of 16 patients imaged from 7/2019 to 11/2020, 15 subjects were evaluable with 20 lesions (radiation necrosis, n = 16; tumor progression, n = 4). Higher SUVmax statistically significantly predicted tumor progression (AUC = 0.875; p = 0.011). Lesion SUVmean (AUC = 0.875; p = 0.018), SUVpeak (AUC = 0.813; p = 0.007), and SUVpeak-to-normal-brain (AUC = 0.859; p = 0.002) also predicted tumor progression, whereas SUVmax-to-normal-brain (p = 0.1) and SUVmean-to-normal-brain (p = 0.5) did not. Qualitative visual scores were significant predictors for readers 1 (AUC = 0.750; p < 0.001) and 3 (AUC = 0.781; p = 0.045), but not for reader 2 (p = 0.3). Visual interpretations were significant predictors for reader 1 (AUC = 0.898; p = 0.012) but not for reader 2 (p = 0.3) or 3 (p = 0.2). CONCLUSIONS: In this prospective pilot study of patients with brain metastases previously treated with radiosurgery presenting with a contemporary MRI brain with a lesion equivocal for radiation necrosis versus tumor progression, 18F-fluciclovine PET/CT repurposed intracranially demonstrated encouraging diagnostic accuracy, supporting the pursuit of larger clinical trials which will be necessary to establish diagnostic criteria and performance.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Adulto , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radiocirurgia/efeitos adversos , Projetos Piloto , Estudos Prospectivos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/etiologia , Necrose/diagnóstico por imagem , Necrose/etiologia
8.
Eur J Radiol ; 162: 110782, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37004362

RESUMO

PURPOSE: VERDICT (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) MRI is a multi b-value, variable diffusion time DWI sequence that allows generation of ADC maps from different b-value and diffusion time combinations. The aim was to assess precision of prostate ADC measurements from varying b-value combinations using VERDICT and determine which protocol provides the most repeatable ADC. MATERIALS AND METHODS: Forty-one men (median age: 67.7 years) from a prior prospective VERDICT study (April 2016-October 2017) were analysed retrospectively. Men who were suspected of prostate cancer and scanned twice using VERDICT were included. ADC maps were formed using 5b-value combinations and the within-subject standard deviations (wSD) were calculated per ADC map. Three anatomical locations were analysed per subject: normal TZ (transition zone), normal PZ (peripheral zone), and index lesions. Repeated measures ANOVAs showed which b-value range had the lowest wSD, Spearman correlation and generalized linear model regression analysis determined whether wSD was related to ADC magnitude and ROI size. RESULTS: The mean lesion ADC for b0b1500 had the lowest wSD in most zones (0.18-0.58x10-4 mm2/s). The wSD was unaffected by ADC magnitude (Lesion: p = 0.064, TZ: p = 0.368, PZ: p = 0.072) and lesion Likert score (p = 0.95). wSD showed a decrease with ROI size pooled over zones (p = 0.019, adjusted regression coefficient = -1.6x10-3, larger ROIs for TZ versus PZ versus lesions). ADC maps formed with a maximum b-value of 500 s/mm2 had the largest wSDs (1.90-10.24x10-4 mm2/s). CONCLUSION: ADC maps generated from b0b1500 have better repeatability in normal TZ, normal PZ, and index lesions.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Idoso , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos Prospectivos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
9.
Acad Radiol ; 30(1): 3-13, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35491345

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to test for superiority of wide-angle digital breast tomosynthesis plus synthetic mammography (Insight 2D) in comparison to full-field digital mammography (FFDM). MATERIALS AND METHODS: In this study, twenty readers interpreted 350 screening and diagnostic cases of wide-angle digital breast tomosynthesis (DBT) plus Insight 2D and FFDM in two separate reading sessions separated by at least a 6-week washout period. Breast-level estimates of the area under the curve and sensitivity along with subject-level recall rate were measured and compared between wide-angle DBT plus Insight 2D and FFDM. The same measures were also assessed for dense breasts. A hierarchical analysis plan was used to control the study's type I error rate at 0.05. RESULTS: The mean breast-level area under the curve for distinguishing breasts with cancer from non-cancer breasts was 0.893 with DBT plus Insight 2D versus 0.837 with FFDM, showing superiority of DBT plus Insight 2D (p < 0.001). Breast-level sensitivity was significantly superior for DBT plus Insight 2D in comparison to FFDM (0.852 vs. 0.805, p = 0.043). Subject-level recall rate for DBT plus Insight 2D was significantly lower in comparison to FFDM (0.344 vs. 0.473, p < 0.001). For dense breasts, the readers' accuracy with DBT plus Insight 2D was superior to their accuracy with FFDM (0.875 vs. 0.830, p = 0.026), and their recall rate was significantly lower for DBT plus Insight 2D in comparison to FFDM (0.338 vs. 0.441, p = 0.003). CONCLUSION: Reader performance with wide-angle DBT plus Insight 2D is superior to that with FFDM, showing significantly higher breast-level accuracy and sensitivity and significantly lower recall rates.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Mama/diagnóstico por imagem , Programas de Rastreamento , Tórax , Coleta de Dados , Neoplasias da Mama/diagnóstico por imagem , Estudos Retrospectivos
10.
Am J Epidemiol ; 192(4): 632-643, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-36549904

RESUMO

In diagnostic medicine, the true disease status of a patient is often represented on an ordinal scale-for example, cancer stage (0, I, II, III, or IV) or coronary artery disease severity measured using the Coronary Artery Disease Reporting and Data System (CAD-RADS) scale (none, minimal, mild, moderate, severe, or occluded). With advances in quantitation of diagnostic images and in artificial intelligence (AI), both supervised and unsupervised algorithms are being developed to help physicians correctly grade disease. Most of the diagnostic accuracy literature deals with binary disease status (disease present or absent); however, tests diagnosing ordinal-scaled diseases should not be reduced to a binary status just to simplify diagnostic accuracy testing. In this paper, we propose different characterizations of ordinal-scale accuracy for different clinical use scenarios, along with methods for comparing tests. In the simplest scenario, just the proportion of correct grades is considered; other scenarios address the magnitude and direction of misgrading; and at the other extreme, a weighted accuracy measure with weights based on the relative costs of different types of misgrading is presented. The various scenarios are illustrated using a coronary artery disease example where the accuracy of AI algorithms in providing patients with the correct CAD-RADS grade is assessed.


Assuntos
Doença da Artéria Coronariana , Humanos , Angiografia Coronária/métodos , Inteligência Artificial , Algoritmos , Testes Diagnósticos de Rotina
11.
Acad Radiol ; 30(2): 215-229, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36411153

RESUMO

This paper is the fifth in a five-part series on statistical methodology for performance assessment of multi-parametric quantitative imaging biomarkers (mpQIBs) for radiomic analysis. Radiomics is the process of extracting visually imperceptible features from radiographic medical images using data-driven algorithms. We refer to the radiomic features as data-driven imaging markers (DIMs), which are quantitative measures discovered under a data-driven framework from images beyond visual recognition but evident as patterns of disease processes irrespective of whether or not ground truth exists for the true value of the DIM. This paper aims to set guidelines on how to build machine learning models using DIMs in radiomics and to apply and report them appropriately. We provide a list of recommendations, named RANDAM (an abbreviation of "Radiomic ANalysis and DAta Modeling"), for analysis, modeling, and reporting in a radiomic study to make machine learning analyses in radiomics more reproducible. RANDAM contains five main components to use in reporting radiomics studies: design, data preparation, data analysis and modeling, reporting, and material availability. Real case studies in lung cancer research are presented along with simulation studies to compare different feature selection methods and several validation strategies.


Assuntos
Neoplasias Pulmonares , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Curva ROC , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Diagnóstico por Imagem , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão
12.
Curr Probl Cardiol ; 48(2): 101456, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36265589

RESUMO

The objective of the study was to construct a multi-parametric mitral annular calcification (MAC) score using computed tomography (CT) features for prediction of outcomes in patients undergoing mitral valve surgery. We constructed a multi-parametric MAC score, which ranges between 2 and 12, and consists of Agatston calcium score (1 point: <1000 Agatston units (AU); 2 points: 1000-<3000 AU; 3 points: 3000-5000 AU; 4 points: >5000 AU), quantitative MAC circumferential angle (1 point: <90°; 2 points: 90-<180°; 3 points: 180-<270°; 4 points: 270-360°), involvement of trigones (1 point: 1 trigone; 2 points: both trigones), and 1 point each for myocardial infiltration and left ventricular outflow tract extension/involvement of aorto-mitral curtain. The association between MAC score and clinical outcomes was evaluated. The study cohort consisted of 334 patients undergoing mitral valve surgery (128 mitral valve repairs, 206 mitral valve replacements) between January 2011 and September 2019, who had both non-contrast gated CT scan and evidence of MAC. The mean age was 72 ± 11 years, with 58% of subjects being female. MAC score was a statistically significant predictor of total operation time (P<0.001), cross-clamp time (P = 0.001) and in-hospital complications (P = 0.003). Additionally, MAC score was a significant predictor of time to all-cause death (P = 0.046). A novel multi-parametric score based on CT features allowed systematic assessment of MAC, and predicted clinical outcomes in patients with mitral valve dysfunction undergoing mitral valve surgery.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Tomografia Computadorizada por Raios X
13.
J Am Coll Radiol ; 19(6): 782-791, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35487247

RESUMO

In the spring of 2021, the ACR approved a proposal to improve the consistency, transparency, and administrative oversight of the ACR Reporting and Data Systems (RADS). A working group of experts and stakeholders was convened to draft this governance document. Major advances include (1) forming a RADS Steering Committee, (2) establishing minimum requirements and evidence standards for new and existing RADS, and (3) outlining a governance structure and communication strategy for RADS.


Assuntos
Sistemas de Dados , Nódulo da Glândula Tireoide , Comunicação , Previsões , Humanos , Cuidados Paliativos , Estudos Retrospectivos , Ultrassonografia
14.
Am J Sports Med ; 50(4): 951-961, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35373606

RESUMO

BACKGROUND: Patients undergoing anterior cruciate ligament reconstruction (ACLR) are at an increased risk for posttraumatic osteoarthritis (PTOA). While we have previously shown that meniscal treatment with ACLR predicts more radiographic PTOA at 2 to 3 years postoperatively, there are a limited number of similar studies that have assessed cartilage directly with magnetic resonance imaging (MRI). HYPOTHESIS: Meniscal repair or partial meniscectomy at the time of ACLR independently predicts more articular cartilage damage on 2- to 3-year postoperative MRI compared with a healthy meniscus or a stable untreated tear. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: A consecutive series of patients undergoing ACLR from 1 site within the prospective, nested Multicenter Orthopaedic Outcomes Network (MOON) cohort underwent bilateral knee MRI at 2 to 3 years postoperatively. Patients were aged <36 years without previous knee injuries, were injured while playing sports, and had no history of concomitant ligament surgery or contralateral knee surgery. MRI scans were graded by a board-certified musculoskeletal radiologist using the modified MRI Osteoarthritis Knee Score (MOAKS). A proportional odds logistic regression model was built to predict a MOAKS-based cartilage damage score (CDS) relative to the contralateral control knee for each compartment as well as for the whole knee, pooled by meniscal treatment, while controlling for sex, age, body mass index, baseline Marx activity score, and baseline operative cartilage grade. For analysis, meniscal injuries surgically treated with partial meniscectomy or meniscal repair were grouped together. RESULTS: The cohort included 60 patients (32 female; median age, 18.7 years). Concomitant meniscal treatment at the time of index ACLR was performed in 17 medial menisci (13 meniscal repair and 4 partial meniscectomy) and 27 lateral menisci (3 meniscal repair and 24 partial meniscectomy). Articular cartilage damage was worse in the ipsilateral reconstructed knee (P < .001). A meniscal injury requiring surgical treatment with ACLR predicted a worse CDS for medial meniscal treatment (medial compartment CDS: P = .005; whole joint CDS: P < .001) and lateral meniscal treatment (lateral compartment CDS: P = .038; whole joint CDS: P = .863). Other predictors of a worse relative CDS included age for the medial compartment (P < .001), surgically observed articular cartilage damage for the patellofemoral compartment (P = .048), and body mass index (P = .007) and age (P = .020) for the whole joint. CONCLUSION: A meniscal injury requiring surgical treatment with partial meniscectomy or meniscal repair at the time of ACLR predicted worse articular cartilage damage on MRI at 2 to 3 years after surgery. Further research is required to differentiate between the effects of partial meniscectomy and meniscal repair.


Assuntos
Lesões do Ligamento Cruzado Anterior , Cartilagem Articular , Menisco , Ortopedia , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/patologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Cartilagem Articular/cirurgia , Estudos de Coortes , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Menisco/diagnóstico por imagem , Menisco/cirurgia , Estudos Prospectivos
15.
J Cardiovasc Magn Reson ; 24(1): 12, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35193584

RESUMO

BACKGROUND: Significant aortic regurgitation (AR) leads to left ventricular (LV) remodeling; however, little data exist regarding sex-based differences in LV remodeling in this setting. We sought to compare LV remodeling and AR severity, assessed by echocardiography and cardiovascular magnetic resonance (CMR), to discern sex-based differences. METHODS: Patients with ≥ moderate chronic AR by echocardiography who underwent CMR within 90 days between December 2005 and October 2015 were included. Nonlinear regression models were built to assess the effect of AR regurgitant fraction (RF) on LV remodeling. A generalized linear model and Bland Altman analyses were constructed to evaluate differences between CMR and echocardiography. Referral for surgical intervention based on symptoms and LV remodeling was evaluated. RESULTS: Of the 243 patients (48.3 ± 16.6 years, 58 (24%) female), 119 (49%) underwent surgical intervention with a primary indication of severe AR, 97 (82%) men, 22 (18%) women. Significant sex differences in LV remodeling emerged on CMR. Women demonstrated significantly smaller LV end-diastolic volume index (LVEDVI) (96.8 ml/m2 vs 125.6 ml/m2, p < 0.001), LV end-systolic volume index (LVESVI) (41.1 vs 54.5 ml/m2, p < 0.001), blunted LV dilation in the setting of increasing AR severity (LVEDVI p value < 0.001, LVESVI p value 0.011), and LV length indexed (8.32 vs 9.69 cm, p < 0.001). On Bland Altman analysis, a significant interaction with sex and LV diameters was evident, demonstrating a significant increase in the difference between CMR and echocardiography measurements as the LV enlarged in women: LVEDVI (p = 0.006), LVESVI (p < 0.001), such that echocardiographic measurements increasingly underestimated LV diameters in women as the LV enlarged. LV length was higher for males with a linear effect from RF (p < 0.001), with LV length increasing at a higher rate with increasing RF for males compared to females (two-way interaction with sex p = 0.005). Sphericity volume index was higher for men after adjusting for a relative wall thickness (p = 0.033). CONCLUSIONS: CMR assessment of chronic AR revealed significant sex differences in LV remodeling and significant echocardiographic underestimation of LV dilation, particularly in women. Defining optimal sex-based CMR thresholds for surgical referral should be further developed. TRIAL REGISTRATION: NA.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Caracteres Sexuais , Função Ventricular Esquerda , Remodelação Ventricular
16.
Magn Reson Med ; 87(3): 1184-1206, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34825741

RESUMO

On behalf of the International Society for Magnetic Resonance in Medicine (ISMRM) Quantitative MR Study Group, this article provides an overview of considerations for the development, validation, qualification, and dissemination of quantitative MR (qMR) methods. This process is framed in terms of two central technical performance properties, i.e., bias and precision. Although qMR is confounded by undesired effects, methods with low bias and high precision can be iteratively developed and validated. For illustration, two distinct qMR methods are discussed throughout the manuscript: quantification of liver proton-density fat fraction, and cardiac T1 . These examples demonstrate the expansion of qMR methods from research centers toward widespread clinical dissemination. The overall goal of this article is to provide trainees, researchers, and clinicians with essential guidelines for the development and validation of qMR methods, as well as an understanding of necessary steps and potential pitfalls for the dissemination of quantitative MR in research and in the clinic.


Assuntos
Imageamento por Ressonância Magnética , Terapia com Prótons , Viés , Espectroscopia de Ressonância Magnética , Prótons , Reprodutibilidade dos Testes
17.
Am J Sports Med ; 49(5): 1251-1261, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33793363

RESUMO

BACKGROUND: The incidence of posttraumatic osteoarthritis (PTOA) based on clinical radiographic grading criteria at 10 years after anterior cruciate ligament (ACL) reconstruction (ACLR) has not been well-defined in a prospective cohort of young athletic patients. HYPOTHESIS: Among young athletic patients, there is a high incidence of clinical radiographic PTOA at 10 years after ACLR. Additionally, there is a significant difference in clinical radiographic osteoarthritis (OA) changes (joint space narrowing and osteophyte formation) between ACL-reconstructed and contralateral knees at 10 years. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: The first 146 patients in an ongoing nested cohort study of the Multicenter Orthopaedic Outcomes Network (MOON) prospective cohort presented for a minimum 10-year follow-up. Included patients had a sports-related ACL injury, were aged <33 years at the time of ACLR, had no history of ipsilateral or contralateral knee surgery, and did not undergo revision ACLR before follow-up. Bilateral knee metatarsophalangeal view radiographs were obtained and graded according to International Knee Documentation Committee (IKDC), Osteoarthritis Research Society International (OARSI), and modified Kellgren-Lawrence (KL) criteria by 2 blinded reviewers. The incidence and severity of ipsilateral and contralateral radiographic OA were determined among patients without a contralateral ACL injury before 10-year follow-up (N = 133). RESULTS: Interrater reliability was substantial for the IKDC (Gwet Agreement Coefficient [AC] 1 = 0.71), moderate for the KL (0.48), and almost perfect for the OARSI (0.84) grading systems. Among patients with a contralateral radiographically normal knee, the 10-year incidence of clinical radiographic PTOA after ACLR was 37% as defined by osteophytes and 23% as defined by joint space narrowing. The maximum side-to-side difference in the OARSI osteophyte grade in the medial or lateral compartment was 0 in 65% of patients, 1 in 20%, and ≥2 in 15%. The maximum side-to-side difference in the OARSI joint space narrowing grade was 0 in 77% of patients, 1 in 19%, and ≥2 in 4%. CONCLUSION: In young active patients, the 10-year incidence of clinical radiographic PTOA after ACLR was 37% as defined by osteophytes and 23% as defined by joint space narrowing. The mean difference in the degree of osteophyte formation (≤1 grade in 85%) and joint space narrowing (≤1 grade in 96%) between the ACL-reconstructed and contralateral knees was small. REGISTRATION: NCT02717559 (ClinicalTrials.gov identifier).


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ortopedia , Osteoartrite do Joelho , Osteoartrite , Idoso , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/epidemiologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Estudos de Coortes , Humanos , Incidência , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/epidemiologia , Osteoartrite do Joelho/etiologia , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
Ann Work Expo Health ; 65(4): 463-474, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33458738

RESUMO

OBJECTIVES: N95 filtering facepiece respirators (N95 FFRs) and surgical masks are comprised of multiple layers of nonwoven polypropylene. Tight-fitting N95 FFRs are respiratory protective devices (RPDs) designed to efficiently filter aerosols. During the COVID-19 pandemic, health care workers (HCWs) throughout the world continue to face shortages of disposable N95 FFRs. Existing version of widely available FDA cleared loose-fitting surgical masks with straps do not provide reliable protection against aerosols. We tested the faceseal of a modified strapless form-fitting sealed version of surgical mask using quantitative fit testing (QNFT) and compared the performance of this mask with that of N95 FFRs and unmodified loose-fitting surgical masks. METHODS: Twenty HCWs participated in the study (10 women; 10 men; age 23-59 years). To create the sealed surgical masks, we removed the straps from loose-fitting surgical masks, made new folds, and used adhesive medical tape to secure the new design. All participants underwent QNFT with a loose-fitting surgical mask, the sealed surgical mask, and an N95 FFR; fit factors were recorded. Each QNFT was performed using a protocol of four exercises: (i) bending over, (ii) talking, (iii) moving head side to side, and (iv) moving head up and down. When the overall fit factor for the sealed surgical mask or N95 FFR was <100, the participant retook the test. Participants scored the breathability and comfort of the sealed surgical mask and N95 FFR on a visual analog scale (VAS) ranging from 0 (unfavorable) to 10 (favorable). RESULTS: The median fit factor for the sealed surgical mask (53.8) was significantly higher than that of the loose-fitting surgical mask (3.0) but lower than that of the N95 FFR (177.0) (P < 0.001), equating to significantly lower inward leakage of ambient aerosols (measuring 0.04-0.06 µm) with the sealed surgical mask (geometric mean 1.79%; geometric standard deviation 1.45%; range 0.97-4.03%) than with the loose-fitting surgical mask (29.5%; 2.01%; 25-100.0%) but still higher than with the N95 FFR (0.66%; 1.46%; 0.50-1.97%) (P < 0.001). Sealed surgical masks led to a marked reduction (range 60-98%) in inward leakage of aerosols in all the participants, compared to loose-fitting surgical masks. Among the exercises, talking had a greater effect on reducing overall fit factor for the sealed surgical mask than for the N95 FFR; when talking was excluded, the fit factor for the sealed surgical mask improved significantly (median 53.8 to 81.5; P < 0.001). The sealed surgical mask, when compared with the N95 FFR, offered better reported breathability (median VAS 9 versus 5; P < 0.001) and comfort (9 versus 5; P < 0.001). CONCLUSIONS: Widely available loose-fitting surgical masks can be easily modified to achieve faceseal with adhesives. Unlike loose-fitting surgical masks, sealed surgical masks can markedly reduce inward leakage of aerosols and may therefore offer useful levels of respiratory protection during an extreme shortage of N95 FFRs and could benefit HCWs who cannot comply with N95 FFRs due to intolerance. However, because a wide range of surgical masks is commercially available, individual evaluation of such masks is highly recommended before sealed versions are used as RPDs.


Assuntos
COVID-19 , Exposição Ocupacional , Adulto , Feminino , Filtração , Humanos , Masculino , Máscaras , Pessoa de Meia-Idade , Respiradores N95 , Pandemias , SARS-CoV-2 , Adulto Jovem
19.
Circ Cardiovasc Imaging ; 13(9): e011126, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32900226

RESUMO

BACKGROUND: Cardiac computed tomography (CT) is emerging as an adjunctive modality to echocardiography in the evaluation of infective endocarditis (IE) and surgical planning. CT studies in IE have, however, focused on its diagnostic rather than prognostic utility, the latter of which is important in high-risk diseases like IE. We evaluated the associations between cardiac CT and transesophageal echocardiography (TEE) findings and adverse outcomes after IE surgery. METHODS: Of 833 consecutive patients with surgically proven IE during May 1, 2014 to May 1, 2019, at Cleveland Clinic, 155 underwent both preoperative ECG-gated contrast-enhanced CT and TEE. Multivariable analyses were performed to identify CT and TEE biomarkers that predict adverse outcomes after IE surgery, adjusting for EuroSCORE II (European System for Cardiac operative Risk Evaluation II). RESULTS: CT and TEE were positive for IE in 123 (75.0%) and 124 (75.6%) of patients, respectively. Thirty-day mortality occurred in 3 (1.9%) patients and composite mortality or morbidities in 72 (46.5%). Pseudoaneurysm or abscess detected on TEE was the only imaging biomarker to show independent association with composite mortality or morbidities in-hospital, with odds ratio (95% CI) of 3.66 (1.76-7.59), P=0.001. There were 17 late deaths, and both pseudoaneurysm or abscess detected on CT and fistula detected on CT were the only independent predictors of total mortality during follow-up, with hazards ratios (95% CI) of 3.82 (1.25-11.7), P<0.001 and 9.84 (1.89-51.0), P=0.007, respectively. CONCLUSIONS: We identified cardiac CT and TEE features that predicted separate adverse outcomes after IE surgery. Imaging biomarkers can play important roles incremental to conventional clinical factors for risk stratification in patients undergoing IE surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Endocardite/diagnóstico por imagem , Endocardite/cirurgia , Complicações Pós-Operatórias/etiologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/mortalidade , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Endocardite/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Ohio , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
20.
Quant Imaging Med Surg ; 10(9): 1748-1762, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32879854

RESUMO

BACKGROUND: MRI acceleration using deep learning (DL) convolutional neural networks (CNNs) is a novel technique with great promise. Increasing the number of convolutional layers may allow for more accurate image reconstruction. Studies on evaluating the diagnostic interchangeability of DL reconstructed knee magnetic resonance (MR) images are scarce. The purpose of this study was to develop a deep CNN (DCNN) with an optimal number of layers for accelerating knee magnetic resonance imaging (MRI) acquisition by 6-fold and to test the diagnostic interchangeability and image quality of nonaccelerated images versus images reconstructed with a 15-layer DCNN or 3-layer CNN. METHODS: For the feasibility portion of this study, 10 patients were randomly selected from the Osteoarthritis Initiative (OAI) cohort. For the interchangeability portion of the study, 40 patients were randomly selected from the OAI cohort. Three readers assessed meniscal and anterior cruciate ligament (ACL) tears and cartilage defects using DCNN, CNN, and nonaccelerated images. Image quality was subjectively graded as nondiagnostic, poor, acceptable, or excellent. Interchangeability was tested by comparing the frequency of agreement when readers used both accelerated and nonaccelerated images to frequency of agreement when readers only used nonaccelerated images. A noninferiority margin of 0.10 was used to ensure type I error ≤5% and power ≥80%. A logistic regression model using generalized estimating equations was used to compare proportions; 95% confidence intervals (CIs) were constructed. RESULTS: DCNN and CNN images were interchangeable with nonaccelerated images for all structures, with excess disagreement values ranging from -2.5% [95% CI: (-6.1, 1.1)] to 3.0% [95% CI: (-0.1, 6.1)]. The quality of DCNN images was graded higher than that of CNN images but less than that of nonaccelerated images [excellent/acceptable quality: DCNN, 95% of cases (114/120); CNN, 60% (72/120); nonaccelerated, 97.5% (117/120)]. CONCLUSIONS: Six-fold accelerated knee images reconstructed with a DL technique are diagnostically interchangeable with nonaccelerated images and have acceptable image quality when using a 15-layer CNN.