Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Hum Exp Toxicol ; 43: 9603271241248631, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38646969

RESUMO

BACKGROUND: Fresh Menthol 3% Nicotine (FM3) is a novel JUUL e-liquid formulation. Its potential toxicity and that of the corresponding base formulation relative to a filtered air (FA) control was studied in a subchronic inhalation study conducted in general accordance with OECD 413. METHODS: Aerosols generated with an intense puffing regime were administered to rats in a nose-only fashion at 1400 µg aerosol collected mass/L on a 6 hour/day basis for 90 days with a 42-day recovery. Exposure atmospheres met target criteria. Systemic exposure was confirmed by plasma measurement of nicotine. RESULTS: No test article-related mortality, clinical signs (other than reversible lower body weight gains in males), clinical pathology or gross findings were noted during this study. No microscopic lesions related to base formulation exposure were identified. Minimal microscopic lesions were observed in the FM3 6-hour exposure group. Microscopic lesions observed in the FM3 6-hour exposure group comprised only minimal laryngeal squamous metaplasia in one male and one female animal. No microscopic lesions related to FM3 exposure remained after the recovery period. CONCLUSION: Exposure atmosphere characterization indicated that conditions were achieved to permit thorough assessment of test articles and results indicate a low order of toxicity for the FM3 Electronic nicotine delivery systems (ENDS) formulation and its base formulation.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina , Animais , Masculino , Feminino , Nicotina/toxicidade , Nicotina/administração & dosagem , Administração por Inalação , Testes de Toxicidade Subcrônica , Aerossóis , Mentol/toxicidade , Mentol/administração & dosagem , Ratos Sprague-Dawley , Ratos , Exposição por Inalação
2.
Toxics ; 12(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38250996

RESUMO

Electronic nicotine delivery systems (ENDSs) are designed as a non-combustible alternative to cigarettes, aiming to deliver nicotine without the harmful byproducts of tobacco combustion. As the category evolves and new ENDS products emerge, it is important to continually assess the levels of toxicologically relevant chemicals in the aerosols and characterize any related toxicology. Herein, we present a proposed framework for characterizing novel ENDS products (i.e., devices and formulations) and determining the reduced risk potential utilizing analytical chemistry and in vitro toxicological studies with a qualitative risk assessment. To demonstrate this proposed framework, long-term stability studies (12 months) analyzing relevant toxicant emissions from six formulations of a next-generation product, JUUL2, were conducted and compared to reference combustible cigarette (CC) smoke under both non-intense and intense puffing regimes. In addition, in vitro cytotoxicity, mutagenicity, and genotoxicity assays were conducted on aerosol and smoke condensates. In all samples, relevant toxicants under both non-intense and intense puffing regimes were substantially lower than those observed in reference CC smoke. Furthermore, neither cytotoxicity, mutagenicity, nor genotoxicity was observed in aerosol condensates generated under both intense and non-intense puffing regimes, in contrast to results observed for reference cigarettes. Following the proposed framework, the results demonstrate that the ENDS products studied in this work generate significantly lower levels of toxicants relative to reference cigarettes and were not cytotoxic, mutagenic, or genotoxic under these in vitro assay conditions.

3.
Front Chem ; 11: 1223967, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37744056

RESUMO

Literature reports the chemical constituent yields of electronic nicotine delivery systems (ENDS) aerosol collected using a range of aerosol collection strategies. The number of puffs to deplete an ENDS product varies widely, but collections often consist of data from the first 50-100 puffs. However, it is not clear whether these discrete puff blocks are representative of constituent yields over the life of a pod. We aimed to assess the effect of differing aerosol collection strategies on reported yields for select chemical constituents in the aerosol of closed pod-based ENDS products. Constituents analyzed were chosen to reflect important classes of compounds from the Final Premarket Tobacco Product Application Guidance. Yields were normalized to total device mass loss (DML). Collection strategies that consisted of partial pod collection were valid for determining yields of constituents whose DML normalized yields were consistent for the duration of pod life. These included primary aerosol constituents, such as propylene glycol, glycerol, and nicotine, and whole pod yields could be determined from initial puff blocks. However, changes were observed in the yields of some metals, some carbonyl compounds, and glycidol over pod life in a chemical constituent and product dependent manner. These results suggest that collection strategies consisting of initial puff block collections require validation per chemical constituent/product and are not appropriate for chemical constituents with variable yields over pod life. Whole pod collection increased sensitivity and accuracy in determining metal, carbonyl, and glycidol yields compared to puff block-based collection methodologies for all products tested.

4.
Food Chem Toxicol ; 179: 113917, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37451597

RESUMO

Electronic nicotine delivery systems (ENDS) are generally recognized as less harmful alternatives for those who would otherwise continue to smoke cigarettes. The potential toxicity of aerosols generated from JUUL Device and Virginia Tobacco (VT3) or Menthol (ME3) JUULpods at 3.0% nicotine concentration was assessed in rats exposed at target aerosol concentrations of 1400 µg/L for up to 6 h/day on a 5 day/week basis for at least 90 days (general accordance with OECD 413). 3R4F reference cigarette smoke (250 µg/L) and Filtered Air were used as comparators. JUUL ENDS product aerosol exposures at >5x the 3R4F cigarette smoke level resulted in greater plasma nicotine and cotinine levels (up to 2x). Notable cigarette smoke related effects included pronounced body weight reductions in male rats, pulmonary inflammation evidenced by elevated lactate dehydrogenase, pro-inflammatory cytokines and neutrophils in bronchoalveolar lavage fluid, increased heart and lung weights, and minimal to marked respiratory tract histopathology. In contrast, ENDS aerosol exposed animals had minimal body weight changes, no measurable inflammatory changes and minimal to mild laryngeal squamous metaplasia. Despite the higher exposure levels, VT3 and ME3 did not result in significant toxicity or appreciable respiratory histopathology relative to 3R4F cigarette smoke following 90 days administration.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Masculino , Ratos , Animais , Nicotina/farmacologia , Ratos Sprague-Dawley , Aerossóis e Gotículas Respiratórios , Produtos do Tabaco/toxicidade , Pulmão , Aerossóis/toxicidade
5.
Sci Rep ; 13(1): 7297, 2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37147399

RESUMO

The harm caused by cigarette smoking is overwhelmingly due to byproducts of tobacco combustion. Electronic Nicotine Delivery Systems (ENDS) provide nicotine to users without combustion, and may support tobacco harm reduction among cigarette smokers who would not otherwise quit in the near term. Analyses of Wave 5 of the Population Assessment of Tobacco and Health (PATH) Study compared biomarkers of exposure (BOE) levels for nicotine, 3 metals, 2 tobacco-specific nitrosamines and 14 smoking-related volatile organic compounds in 151 exclusive ENDS users, 1341 exclusive cigarette smokers, 115 dual users (cigarettes and ENDS), and 1846 past 30-day nonusers of tobacco, adjusting for demographics. Nicotine exposure in ENDS users and dual users did not significantly differ from smokers. Among ENDS users, 16 of 18 other BOEs were significantly lower than smokers'; 9 BOEs were not significantly different from nonusers. Among dual users smoking < 10 cigarettes/day, 15 of 18 non-nicotine BOEs were significantly lower than smokers', whereas in dual users smoking ≥ 10 cigarettes per day none of the BOEs significantly differed from smokers'. In this representative sample of US adults, exclusive use of ENDS (vs. cigarette smoking) was associated with much lower exposures to many harmful chemicals associated with smoking-related disease. BOE levels in dual users were directly related to their cigarette consumption. These BOE data provide further evidence that ENDS expose users to substantially lower levels of toxicants than combustible cigarettes, confirming their potential for harm reduction.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Epilepsias Parciais , Produtos do Tabaco , Adulto , Humanos , Fumantes , Nicotina , Biomarcadores/análise
6.
Toxicol In Vitro ; 84: 105434, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35820568

RESUMO

In vitro testing of Electronic Nicotine Delivery System (ENDS) aerosol condensates is important in evaluating their potential toxicity. Collecting sufficient condensate for these tests is a time consuming and costly procedure. The "triple puff (TP)" is a novel system which collects the aerosol from three ENDS devices sequentially into a single filter pad and impinger. The TP substantially reduces condensate collection time relative to the conventional single ENDS, single puff (SP), device system. Both the TP and SP (using two puffing profiles) were used to generate condensates from JUUL ENDS e-liquid Mint 5.0% (nicotine by weight). Aerosols were collected using the filter pad and ethanol-containing impinger method. Condensates produced with the SP and TP were compared for concentrations of primary constituents and carbonyl compounds as well as for their cytotoxicity (OECD 129), mutagenicity (OECD 471) and genotoxicity (OECD 487). Condensates generated with the SP and TP, regardless of puffing regimen, were very similar chemically and equivalent in the biological assays tested (not cytotoxic, mutagenic, or genotoxic). The TP device significantly reduces production time of ENDS condensates relative to the standard SP method and thus may facilitate further research by reducing the time and effort required to collect ENDS condensates.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Aerossóis/química , Mutagênicos , Nicotina/toxicidade
7.
J Breath Res ; 15(4)2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34544050

RESUMO

Use of computational fluid dynamic (CFD) modeling to predict temporal and spatial constituent exposure for non-electronic nicotine delivery systems (ENDS) users (passive exposure) provides a more efficient methodology compared to conducting actual exposure studies. We conducted a clinical study measuring exhaled breath concentrations of glycerin, propylene glycol, nicotine, benzoic acid, formaldehyde, acetaldehyde, acrolein, menthol and carbon monoxide from use of eight different commercial ENDS devices and a non-menthol and menthol cigarette. Because baseline adjusted levels of other constituents were not consistently above the limit of detection, the mean minimum and maximum per puff exhaled breath concentrations (N= 20/product) of glycerin (158.7-260.9µg), propylene glycol (0.941-3.58µg), nicotine (0.10-1.06µg), and menthol (0.432-0.605µg) from use of the ENDS products were used as input parameters to predict temporal and spatial concentrations in an environmental chamber, office, restaurant, and car using different ENDS use scenarios. Among these indoor locations and ENDS use scenarios, the car with closed windows resulted in the greatest concentrations while opening the car windows produced the lowest concentrations. The CFD predicted average maximum glycerin and propylene glycol concentration ranged from 0.25 to 1068µg m-3and 1.5 pg m-3to 13.56µg m-3,respectively. For nicotine and menthol the CFD predicted maximum concentration ranged from 0.16 pg m-3to 4.02µg m-3and 0.068 pg m-3to 2.43µg m-3, respectively. There was better agreement for CFD-predicted nicotine concentrations than glycerin and propylene glycol with published reports highlighting important experimental and computational variables. Maximum measured nicotine levels from environmental tobacco smoke in offices, restaurants, and cars exceeded our maximum average CFD predictions by 7-97 times. For all the measured exhaled breath constituents and CFD predicted constituents, except for propylene glycol and glycerin, concentrations were less from use of ENDS products compared to combustible cigarettes. NCT number: NCT04143256.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Poluição por Fumaça de Tabaco , Testes Respiratórios , Humanos , Hidrodinâmica , Nicotina
8.
Sci Rep ; 11(1): 1736, 2021 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-33462299

RESUMO

To assess potential exposure of non-users to exhaled constituents from pod and cartridge electronic nicotine delivery systems (ENDS) products, an environmental clinical study was conducted with (n = 43) healthy adult smokers. Room air concentrations of 34 selected constituents (nicotine, propylene glycol, glycerin, 15 carbonyls, 12 volatile organic compounds, and 4 trace metals) and particle number concentration (0.3 to 25 µm) were compared from use of two ENDS products and conventional cigarettes using room ventilations representative of a residential, an office or a hospitality setting over a 4-h. exposure period. Products used were JUUL ENDS, Virginia Tobacco flavor (Group I), VUSE Solo, Original flavor (Group II) (5.0 and 4.8% nicotine by weight, respectively) and subjects' own conventional cigarettes (Group III). Cumulative 4-h room air sampling and particle counting were performed during prescribed (Groups I and II) and ad libitum product use (all Groups). Conventional cigarette use resulted in significantly more constituents detected and higher 4-h cumulative constituent concentrations compared to use of the ENDS products tested, except for the predominant ENDS ingredients, propylene glycol and glycerin. Use of conventional cigarettes also resulted in greater total particle number concentration than either prescribed or ad libitum use of either of the ENDS used in this study.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Sistemas Eletrônicos de Liberação de Nicotina , Nicotina/análise , Fumantes/estatística & dados numéricos , Produtos do Tabaco/estatística & dados numéricos , Ventilação/métodos , Compostos Orgânicos Voláteis/análise , Adulto , Feminino , Aromatizantes/análise , Humanos , Masculino , Pessoa de Meia-Idade , Propilenoglicol/análise , Produtos do Tabaco/normas , Adulto Jovem
9.
Regul Toxicol Pharmacol ; 112: 104588, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32001280

RESUMO

1,2-Propylene glycol and glycerin, principal components of e-liquids, can thermally degrade to form acetaldehyde, acrolein, and formaldehyde when heated in electronic nicotine delivery systems (ENDS). Recently the flavors in e-liquids were suggested to be the major source of these aldehydes. We used the same 10 ENDS devices to test 5 e-liquid formulations (four flavored & one corresponding non-flavored) and measured device mass loss and levels of acetaldehyde, acrolein, and formaldehyde (30 replicate measurements per formulation). Despite finding reasonable variability in measurements of device mass loss, two out of 10 ENDS devices tested produced outlier values for aerosol levels acetaldehyde, acrolein, and formaldehyde. After removing these devices from further analysis, acceptable variability (≤20% RSD) in aerosol levels of acetaldehyde, and formaldehyde were found. The flavored formulations tested resulted in a consistent and selective increase of 150%-200% in acetaldehyde, no increase or decrease in acrolein and depending on the flavor formulation, an increase, a decrease or no change in formaldehyde levels. Comparison of our results to the literature illustrates the need for development of a standardized ENDS testing protocol. Our results further support that device variability must be fully characterized and considered before assessing the impact of e-liquid formulations.


Assuntos
Aldeídos/metabolismo , Aromatizantes/metabolismo , Vaping/metabolismo , Humanos
10.
Food Chem Toxicol ; 113: 236-240, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29408542

RESUMO

Dosimetry models can be used to predict the dose of inhaled material, but they require several parameters including particle size distribution. The reported particle size distributions for aerosols from electronic nicotine delivery system (ENDS) products vary widely and don't always identify a specific product. A low-flow cascade impactor was used to determine the particle size distribution [mass median aerodynamic diameter (MMAD); geometric standard deviation (GSD)] from 20 different cartridge based ENDS products. To assess losses and vapor phase amount, collection efficiency of the system was measured by comparing the collected mass in the impactor to the difference in ENDS product mass. The levels of nicotine, glycerin, propylene glycol, water, and menthol in the formulations of each product were also measured. Regardless of the ENDS product formulation, the MMAD of all tested products was similar and ranged from 0.9 to 1.2 µm with a GSD ranging from 1.7 to 2.2. There was no consistent pattern of change in the MMAD and GSD as a function of number of puffs (cartridge life). The collection efficiency indicated that 9%-26% of the generated mass was deposited in the collection system or was in the vapor phase. The particle size distribution data are suitable for use in aerosol dosimetry programs.


Assuntos
Nicotina/administração & dosagem , Tamanho da Partícula , Sistemas Eletrônicos de Liberação de Nicotina , Glicerol/análise , Mentol/análise , Nicotina/análise , Propilenoglicol/análise , Água/análise
11.
Artigo em Inglês | MEDLINE | ID: mdl-28846634

RESUMO

There is an ongoing debate regarding the potential of secondhand exposure of non-users to various chemicals from use of e-vapor products (EVPs). Room air levels of 34 chemicals (nicotine, propylene glycol (PG), glycerol, 15 carbonyl chemicals, 12 volatile organic chemicals (VOCs), and four selected trace elements) were measured where EVPs and cigarettes were used by n = 37 healthy adult tobacco users in an exposure chamber. The products used were MarkTen® 2.5% Classic (Group I), a Prototype GreenSmoke® 2.4% (Group II), Ego-T® Tank with subjects' own e-liquids (Group III) and subjects' own conventional cigarettes (Group IV). Products were used under controlled conditions and 4-h ad libitum use. Background (without subjects) and baseline levels (with subjects) were measured. Cumulative 4-h. levels of nicotine, PG and glycerol measured were several-fold below the time-weighted average limits used in workplace exposure evaluation. Most the other chemicals (>75%) were at or below the limit of quantification during EVP use. Significant levels of chemicals (17 out of 34) were observed in Group IV. Overall, our results indicate that under the study conditions with the products tested, cumulative room air levels of the selected chemicals measured over 4-h were relatively small and were several-fold below the current occupational regulatory and consensus limits.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Sistemas Eletrônicos de Liberação de Nicotina/métodos , Produtos do Tabaco , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Regul Toxicol Pharmacol ; 85: 55-63, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28153745

RESUMO

Concerns have been raised about the potential health effects of potential bystander exposure to exhaled aerosols from e-vapor products (EVPs). An exhaled breath collection system (EBS) was developed and analytical methods were verified for collection and analysis of exhaled breath from users of EVPs. Analytical methods were adapted and verified for collection of environmental air samples during EVP use in an exposure chamber. Analysis of constituents in exhaled breath focused on nicotine, propylene glycol, and glycerin (because these are reported as the major constituents in EVPs) and selected carbonyl compounds (acetaldehyde, acrolein, and formaldehyde). Analysis of environmental samples included nicotine, propylene glycol, glycerin, 12 volatile organic compounds (VOCs), 15 carbonyl compounds and 4 metals. The EBS and analytical methods used were found to be suitable for collection and analysis of the target constituents in exhaled breath. Environmental sampling for background levels of VOCs and carbonyl compounds found only acetone, acetaldehyde, benzene, ethylbenzene, formaldehyde, isoprene, methyl ethyl ketone, hexaldehyde, propionaldehyde, and toluene above the limit of quantification in some samples. None of the targeted metals were detected. Background levels of VOCs and carbonyl compounds were consistent with levels previously reported for ambient air.


Assuntos
Testes Respiratórios , Monitoramento Ambiental/métodos , Vaping , Compostos Orgânicos Voláteis/análise , Aerossóis/análise , Expiração
13.
Artigo em Inglês | MEDLINE | ID: mdl-27537903

RESUMO

Concerns have been raised in the literature for the potential of secondhand exposure from e-vapor product (EVP) use. It would be difficult to experimentally determine the impact of various factors on secondhand exposure including, but not limited to, room characteristics (indoor space size, ventilation rate), device specifications (aerosol mass delivery, e-liquid composition), and use behavior (number of users and usage frequency). Therefore, a well-mixed computational model was developed to estimate the indoor levels of constituents from EVPs under a variety of conditions. The model is based on physical and thermodynamic interactions between aerosol, vapor, and air, similar to indoor air models referred to by the Environmental Protection Agency. The model results agree well with measured indoor air levels of nicotine from two sources: smoking machine-generated aerosol and aerosol exhaled from EVP use. Sensitivity analysis indicated that increasing air exchange rate reduces room air level of constituents, as more material is carried away. The effect of the amount of aerosol released into the space due to variability in exhalation was also evaluated. The model can estimate the room air level of constituents as a function of time, which may be used to assess the level of non-user exposure over time.


Assuntos
Aerossóis/análise , Poluição do Ar em Ambientes Fechados/análise , Gases/análise , Fumar , Poluição por Fumaça de Tabaco , Expiração , Humanos , Modelos Estatísticos , Nicotina/análise
14.
Regul Toxicol Pharmacol ; 79: 64-73, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27181452

RESUMO

The use of very low nicotine tobacco cigarettes is currently being investigated as a possible harm reduction strategy. Here, we report the smoke chemistry, toxicity, and physical characteristics of very low nicotine cigarettes that were made using blended tobacco processed through a supercritical CO2 fluid extraction, which resulted in elimination of 96% of nicotine content (denicotinized (denic) tobacco). Three types of test cigarettes (TCs) were manufactured with tobacco filler containing 100% denic tobacco (TC100), 50% denic tobacco and 50% unextracted tobacco (TC50/50), and 100% unextracted tobacco (TC0). Mainstream smoke (MS) was generated for measurement of 46 analytes and cytotoxicity and mutagenicity determination. Analysis of physical characteristics of TCs demonstrated they were well made with <5% variability among cigarettes for most parameters measured. We observed significant changes in the levels of smoke constituents, including decreases in formaldehyde, nitrosamines, and phenol, and increases in aliphatic hydrocarbons, aliphatic nitrogen compounds, aromatic amines, halogen compounds, and metals. Use of denic tobacco resulted in changes in the chemical composition of MS, but these changes did not modify biological activity as measured in the mutagenicity and cytotoxicity assays.


Assuntos
Nicotiana/química , Nicotina/análise , Agonistas Nicotínicos/análise , Fumaça/análise , Fumar , Produtos do Tabaco/análise , Células 3T3 , Animais , Cromatografia com Fluido Supercrítico , Qualidade de Produtos para o Consumidor , DNA Bacteriano/efeitos dos fármacos , DNA Bacteriano/genética , Fibroblastos/efeitos dos fármacos , Fibroblastos/patologia , Humanos , Camundongos , Mutagênese , Testes de Mutagenicidade , Mutação , Nicotina/toxicidade , Agonistas Nicotínicos/toxicidade , Medição de Risco , Salmonella typhimurium/efeitos dos fármacos , Salmonella typhimurium/genética , Fumaça/efeitos adversos , Fumar/efeitos adversos , Nicotiana/toxicidade , Produtos do Tabaco/toxicidade
15.
Inhal Toxicol ; 28(1): 22-38, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26787428

RESUMO

A prototype electronic cigaret device and three formulations were evaluated in a 90-day rat inhalation study followed by a 42-day recovery period. Animals were randomly assigned to groups for exposure to low-, mid- and high-dose levels of aerosols composed of vehicle (glycerin and propylene glycol mixture); vehicle and 2.0% nicotine; or vehicle, 2.0% nicotine and flavor mixture. Daily targeted aerosol total particulate matter (TPM) doses of 3.2, 9.6 and 32.0 mg/kg/day were achieved by exposure to 1 mg/L aerosol for 16, 48 and 160 min, respectively. Pre-study evaluations included indirect ophthalmoscopy, virology and bacteriological screening. Body weights, clinical observations and food consumption were monitored weekly. Plasma nicotine and cotinine and carboxyhemoglobin levels were measured at days 28 and 90. After days 28, 56 and 90, lung function measurements were obtained. Biological endpoints after 90-day exposure and 42-day recovery period included clinical pathology, urinalysis, bronchoalveolar fluid (BALF) analysis, necropsy and histopathology. Treatment-related effects following 90 days of exposure included changes in body weight, food consumption and respiratory rate. Dose-related decreases in thymus and spleen weights, and increased BALF lactate dehydrogenase, total protein, alveolar macrophages, neutrophils and lung weights were observed. Histopathology evaluations revealed sporadic increases in nasal section 1-4 epithelial hyperplasia and vacuolization. Following the recovery period, effects in the nose and BALF were persistent while other effects were resolved. The no observed effect level based upon body weight decreases is considered to be the mid-dose level for each formulation, equivalent to a daily TPM exposure dose of approximately 9.6 mg/kg/day.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Aromatizantes/toxicidade , Administração por Inalação , Aerossóis , Animais , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/citologia , Contagem de Células , Cotinina/sangue , Feminino , L-Lactato Desidrogenase/metabolismo , Masculino , Nicotina/sangue , Nível de Efeito Adverso não Observado , Nariz/efeitos dos fármacos , Nariz/patologia , Ratos Sprague-Dawley , Testes de Toxicidade Subcrônica
16.
J Occup Environ Hyg ; 13(4): 275-83, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26576834

RESUMO

While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Sistemas Eletrônicos de Liberação de Nicotina , Saúde Ocupacional , Formaldeído/análise , Glicerol/análise , Mentol/análise , Nicotina/análise , Material Particulado/análise , Projetos Piloto , Propilenoglicol/análise
17.
Regul Toxicol Pharmacol ; 70(1): 138-48, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24973503

RESUMO

A total of 20 commercial cigarette and 16 commercial smokeless tobacco products were assayed for 96 compounds listed as harmful and potentially harmful constituents (HPHCs) by the US Food and Drug Administration. For each product, a single lot was used for all testing. Both International Organization for Standardization and Health Canada smoking regimens were used for cigarette testing. For those HPHCs detected, measured levels were consistent with levels reported in the literature, however substantial assay variability (measured as average relative standard deviation) was found for most results. Using an abbreviated list of HPHCs, statistically significant differences for most of these HPHCs occurred when results were obtained 4-6months apart (i.e., temporal variability). The assay variability and temporal variability demonstrate the need for standardized analytical methods with defined repeatability and reproducibility for each HPHC using certified reference standards. Temporal variability also means that simple conventional comparisons, such as two-sample t-tests, are inappropriate for comparing products tested at different points in time from the same laboratory or from different laboratories. Until capable laboratories use standardized assays with established repeatability, reproducibility, and certified reference standards, the resulting HPHC data will be unreliable for product comparisons or other decision making in regulatory science.


Assuntos
Produtos do Tabaco/análise , Tabaco sem Fumaça/análise , Canadá , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Produtos do Tabaco/efeitos adversos , Tabaco sem Fumaça/efeitos adversos , Estados Unidos , United States Food and Drug Administration
18.
Nicotine Tob Res ; 16(7): 948-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24638852

RESUMO

INTRODUCTION: Few clinical studies involving cigarettes have provided a comprehensive picture of smoke exposure, test article characterization, and insights into sensory properties combined. The purpose of these pilot studies was to determine whether cigarettes with different levels of nicotine but similar tar levels would affect sensory experience or smoking behavior so as to significantly alter levels of selected biomarkers of exposure (BOE). METHODS: In 2 confined, double-blind studies, 120 adult smokers switched from Marlboro Gold cigarettes at baseline to either 1 of 2 lower nicotine cigarettes or 1 of 2 higher nicotine cigarettes and then to the other cigarette after 5 days. Urinary excretion of exposure biomarkers (nicotine equivalents [NE], total and free 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol [NNAL], 1-hydroxypyrene, and 3-hydroxypropyl mercapturic acid) as well as carboxyhemoglobin and plasma cotinine were measured at baseline, Day 5, and Day 10. Daily cigarette consumption was monitored and sensory characteristics were rated for each cigarette. RESULTS: With higher nicotine yield, urine NE, urine total NNAL, and plasma cotinine increased while nonnicotine BOE decreased without changes in cigarette consumption. In contrast, with lower nicotine yield, urine NE, urine total NNAL, and plasma cotinine dropped while nonnicotine BOE and cigarettes per day increased. Higher nicotine cigarettes were rated harsher and stronger than at baseline while lower nicotine cigarettes were less strong. All 4 test cigarettes were highly disliked. CONCLUSIONS: These studies demonstrate that abrupt increases or decreases in nicotine and the resulting sensory changes impact BOE through changes in intensity or frequency of smoking.


Assuntos
Biomarcadores/urina , Nicotina/análise , Percepção/efeitos dos fármacos , Fumar/urina , Produtos do Tabaco/análise , Adulto , Carboxihemoglobina/metabolismo , Cotinina/sangue , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/urina , Nitrosaminas/urina , Projetos Piloto , Pirenos/urina , Piridinas/urina , Fumar/sangue , Alcatrões/análise , Adulto Jovem
19.
Inhal Toxicol ; 26(4): 207-21, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24568577

RESUMO

A formulation of tobacco extract containing 4% nicotine (TE) and similar nicotine formulation containing vehicle and 4% nicotine (NF) were evaluated using animal inhalation assays. Two 4-h inhalation exposures at 1 and 2 mg/L aerosol exposure concentrations, respectively, of the tobacco extract with 4% nicotine formulation showed that the LC50 was greater than 2 mg/L, the maximum concentration tested. All inhalation exposures were conducted using the capillary aerosol generator (CAG). Increasing aerosol TPM concentrations (0, 10, 50, 200, 1000 mg/m(3) TE and 0, 50, 200, 500, 1000 mg/m(3) NF) were generated via the CAG and used to expose groups of male and female rats for 4-h per day for 14 days. In life monitors for potential effects included clinical observations, weekly body weights and food consumption. Post mortem evaluations included gross tissue findings, hematology, clinical chemistry, serum plasma and nicotine levels, absolute and normalized organ and tissue weights, and histopathology of target organs. Treatment-related changes were observed in body weights, hematology, clinical chemistry, organ weights and histopathological findings for TE at the 200 and 1000 mg/m(3) exposure levels, and in the 500 and 1000 mg/m(3) exposure groups for NF. Under the conditions of these studies, the no-observed-adverse-effect level in the rat was approximately 50 mg/m(3) for the TE aerosol-exposed groups, and approximately 200 mg/m(3) in the NF aerosol-exposed groups.


Assuntos
Nicotiana , Nicotina/toxicidade , Extratos Vegetais/toxicidade , Administração por Inalação , Animais , Peso Corporal/efeitos dos fármacos , Cotinina/sangue , Ingestão de Alimentos/efeitos dos fármacos , Feminino , Laringe/efeitos dos fármacos , Laringe/patologia , Masculino , Nicotina/sangue , Nicotina/farmacocinética , Nível de Efeito Adverso não Observado , Tamanho do Órgão/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Baço/efeitos dos fármacos , Baço/crescimento & desenvolvimento , Baço/patologia , Timo/efeitos dos fármacos , Timo/crescimento & desenvolvimento , Timo/patologia , Testes de Toxicidade Aguda , Testes de Toxicidade Subaguda
20.
Inhal Toxicol ; 25 Suppl 2: 1-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24341842

RESUMO

CONTEXT: In addition to tobacco and cigarette ingredients, there are many non-tobacco components and processes used to manufacture commercial cigarettes. Proposed cigarette components and manufacturing process changes were evaluated using a tiered toxicological testing program. OBJECTIVE: The toxicological testing and evaluation of proposed changes to selected non-tobacco cigarette components and manufacturing processes are described in this special report. MATERIALS AND METHODS: Selected non-tobacco cigarette components and manufacturing processes were evaluated using experimental and control cigarettes. These experimental cigarettes were evaluated using mainstream smoke chemistry, bacterial mutagenicity and cytotoxicity assays. In some evaluations, 90-day nose-only mainstream smoke inhalation studies using rats were performed. RESULTS: Some proposed design changes were not implemented, or limitations on their use were established. Most study results, however, were similar to those previously reported in the scientific literature for design changes in cigarette construction. CONCLUSION: The studies reported in the series of publication demonstrate that our testing approach is feasible for evaluation of cigarette component and manufacturing process changes.


Assuntos
Qualidade de Produtos para o Consumidor , Nicotiana/toxicidade , Fumaça/efeitos adversos , Indústria do Tabaco/métodos , Produtos do Tabaco/toxicidade , Animais , Humanos , Teste de Materiais , Fumaça/análise , Nicotiana/química , Produtos do Tabaco/análise , Poluição por Fumaça de Tabaco/prevenção & controle , Testes de Toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA