Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hand Surg Am ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38597836

RESUMO

PURPOSE: The distal radioulnar joint (DRUJ) is supported by an array of dynamic and static stabilizers, of which the triangular fibrocartilage complex (TFCC) is the most important, and the distal interosseous ligament is next in importance. The distal oblique band (DOB) is an identifiable component of the distal interosseous ligament, found in a subset of the population. Our objective was to determine the contribution of the DOB to DRUJ stability in the presence of a disrupted TFCC. METHODS: Twenty-three above-elbow specimens were prepared by removing the TFCC and the DRUJ joint capsule, preserving the distal interosseous ligament and the pronator quadratus. Cadavers were stratified into two groups-those with, and those without a DOB. A bone plate and screws were attached to the ulna; then, a transverse load was applied to failure, creating a diastasis between the radius and ulna. RESULTS: The group with a DOB had a mean load at failure of 160.7 ± 46.5 N. The group without a DOB had a mean load at failure of 148.0 ± 26.3 N. Stiffness prior to failure was 16.9 N/mm in the group with a DOB and 12.4 N/mm in the group without a DOB. CONCLUSIONS: The current results indicate that the DOB may not substantially contribute to DRUJ stability in the presence of a disrupted TFCC. CLINICAL RELEVANCE: Stability of the DRUJ after TFCC injury may not be substantially improved by the presence of a DOB. Thus, the clinical importance of DOB reconstruction remains unclear.

3.
Tech Hand Up Extrem Surg ; 27(4): 214-219, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439145

RESUMO

We describe a medial approach to the coronoid where the flexor-pronator mass is released from its humeral origin by creating a proximally based tendinous flap. This technique facilitates access to the coronoid, preservation of the medial collateral ligament origin, and repair of the flexor-pronator mass. This approach has utility for all coronoid fracture variations but especially the O'Driscoll anteromedial subtype 3, which includes fractures of the sublime tubercle, the anteromedial facet, and the coronoid tip.


Assuntos
Articulação do Cotovelo , Fraturas Ósseas , Fraturas da Ulna , Humanos , Fraturas da Ulna/cirurgia , Articulação do Cotovelo/cirurgia , Fraturas Ósseas/cirurgia , Úmero , Fixação Interna de Fraturas/métodos
4.
J Hand Surg Glob Online ; 4(6): 328-331, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36425377

RESUMO

Purpose: Distal radius fractures are the most common fractures in adults. Because of the prevalence of these injuries, patients may present with a repeat distal radius fracture on the same wrist through the site of a malunion. We clinically refer to this as an acute on chronic distal radius fracture. In this setting, the restoration of acceptable alignment can be challenging. There is little guidance in the literature for the management of these fractures. We report our experience with acute on chronic distal radius fractures. The secondary fracture plane was used to correct the prior deformity, and the construct was fixated with a fixed angle volar locking plate. Methods: Records of patients with malunion of the distal radius who experienced an acute fracture of the ipsilateral distal radius were reviewed. Inclusion required treatment with open reduction internal fixation using a distal fragment first technique and a volar locking plate through the extended flexor carpi radialis approach. Clinical outcomes and complications were collected. Results: Across 13 patients, the mean follow-up term was 13 months (range, 6-40 months). Radiographic union was noted in all patients. The mean visual analog scale score for pain was 1.8, and the mean Quick Disabilities of the Arm, Shoulder, and Hand score was 21.9. There were no recorded complications. Conclusion: Our results and described technique provide reproducible guidance for the management of acute on chronic distal radius fractures. These cases can be managed using the secondary fracture plane, a distal fragment first technique, and a volar locking plate to correct the preexisting deformity. Type of study/level of evidence: Therapeutic IV.

5.
J Wrist Surg ; 11(3): 219-223, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35837586

RESUMO

Greater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.

6.
J Wrist Surg ; 11(3): 214-218, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35837594

RESUMO

The volar rim of the distal radius is the only bony restraint to volar carpal subluxation. Higher loads across the volar rim require stable and rigid fixation to maintain reduction and allow healing while rehabilitation begins. Volar marginal fragments are not amenable to buttressing by fixed angle volar locking plates. Appropriate management of volar marginal fragments comprises two steps-recognition of their presence and rigid anatomical repair. The best opportunity for success in the presence of a volar marginal fragment is its adequate initial treatment. The purpose of this review is to reinforce the importance of a complete preoperative and intraoperative evaluation of distal radius fractures. Volar marginal fragments can easily be overlooked even following initial reduction and fixation. Understanding the relevant anatomy and loading parameters can facilitate intraoperative decisions on approach and fixation, which are integral to achieving optimal clinical outcomes.

7.
Tech Hand Up Extrem Surg ; 26(4): 257-262, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35698306

RESUMO

It is challenging to restore the clinically acceptable alignment of the distal radius after an acute on chronic fracture or after a secondary fracture occurring after malunion of a primary distal radius fracture. In cases of insignificant primary deformity, restoration to the primary deformity may suffice to obtain a successful clinical result. A borderline acceptable primary radial deformity can be unacceptable after the second injury, resulting in functional disability. If surgery is indicated, the surgeon must contend with both primary and secondary deformities to restore proper distal radius anatomy. We present our technique to correct both primary and secondary distal radius deformities through the new or secondary fracture plane.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Humanos , Fraturas do Rádio/complicações , Fraturas do Rádio/cirurgia , Articulação do Punho , Rádio (Anatomia)/cirurgia , Fraturas Mal-Unidas/cirurgia , Resultado do Tratamento
8.
J Wrist Surg ; 10(6): 536-538, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34877080

RESUMO

The flexor carpi radialis brevis (FCRB) is an anomalous muscle of the forearm that is only present in 3.5 to 8.6% of the population. In the case of volar plating of distal radius fractures, the FCRB inhibits proper fracture exposure and thus hinders proper reduction. A 78-year-old female presented with right distal radius fracture which necessitated internal fixation. Following mobilization and retraction of the flexor carpi radialis tendon, an anomalous muscle belly was identified as the FCRB. With continued difficulty in exposure and fracture site reduction, resection of the FCRB was performed. The patient was able to return to her activities of daily living without pain and demonstrated no appreciable functional deficit. This case report demonstrates a distal radius fracture where FCRB resection was used, resulting in no detrimental clinical outcomes.

9.
J Hand Surg Am ; 43(9): 827-832, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29804695

RESUMO

PURPOSE: Ulnar impaction syndrome is a poorly understood degenerative wrist condition characterized by symptoms of pain thought to be caused by increased loads between the ulnar head and the carpals. Radiographic evaluation often reveals an ulnar-positive wrist. We hypothesize that progressive elongation of the central band of the forearm interosseous ligaments changes the longitudinal radial-ulnar relationships, resulting in an ulnar-positive wrist. The objective of the study was to identify a relationship between the loss of integrity of the forearm interosseous ligaments and increased ulnar variance. METHODS: Six cadaveric human forearms were used to measure displacement of the radius relative to the ulna during axial loading of the lunate fossa of the radius. Radial heights were measured in supination and pronation under a 5-lbF (22-N) preload. Gradual axial loads were applied up to 50 lbF (222N); the resultant axial displacement was measured in supination and pronation. All measurements were evaluated with the interosseous ligament intact and repeated with the central band cut. RESULTS: With an applied 5-lbF preload, cutting the central band increased ulnar variance by 3.02 ± 0.80 mm in supination and by 2.15 ± 0.79 mm in pronation. In supination, when the loads were increased from the 5-lbF preload to 50 lbF, the radius displaced 2.1 times further after the central band was cut (3.00 mm) compared with the group with the intact forearm construct (1.41 mm). In pronation, when the loads were increased from the 5-lbF preload to 50 lbF, the radius displaced 1.8 times further when the central band was cut (2.84 mm) than with the intact forearm construct (1.57 mm). CONCLUSIONS: Because of a parallelogram effect, the radius shifted proximally under a 5-lbF preload, creating an ulnar-positive wrist relationship. Dynamic loading of the forearm after ligament excision resulted in significant additional radial displacement relative to the intact forearm. CLINICAL RELEVANCE: Deficiency in the ligamentous restraints of the central band leads to positive ulnar variance, which could be a factor (among others) that contributes to idiopathic ulnar impaction syndrome.


Assuntos
Antebraço/fisiologia , Ligamentos/lesões , Ligamentos/fisiologia , Rádio (Anatomia)/fisiologia , Ulna/fisiologia , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pronação/fisiologia , Supinação/fisiologia , Suporte de Carga/fisiologia
10.
J Shoulder Elbow Surg ; 26(1): 125-132, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27939280

RESUMO

BACKGROUND: Our primary efficacy objective was to evaluate the effectiveness of the internal joint stabilizer of the elbow (IJS-E) in maintaining concentric location of the elbow during and after removal of the device in the treatment of persistent or recurrent instability after elbow fracture or dislocations, or both. The secondary study objectives were to assess range of motion, Broberg-Morrey functional score, Broberg-Morrey categorical rating, the Disabilities of the Arm, Shoulder and Hand score, and the rate of complications and adverse events after the use of IJS-E. METHODS: Twenty-four patients were studied in a multicenter, nonrandomized, prospective, single-arm study. The IJS-E was used to provide temporary stabilization of the elbow joint and allow a functional range of motion while ligaments and fractures healed. RESULTS: The elbow remained concentrically aligned in 23 of 24 patients. One coronoid-deficient elbow did not maintain concentric reduction. At the last evaluation a minimum of 6 months after device removal, the mean arc of elbow flexion was 119° (range, 80°-150°; standard deviation [SD], 18°), and the mean arc of forearm rotation was 151° (range, 90°-190°; SD, 24°). The mean and median Broberg-Morrey scores were 93 and 97, respectively. Categorically the results were excellent in 14, good in 8, fair in 1, and poor in 1. The mean Disabilities of the Arm, Shoulder and Hand score was 16 (range, 0-68; SD, 18). CONCLUSION: The IJS-E maintains concentric reduction, allows elbow motion, and avoids the inconveniences and pin problems of percutaneous fixation.


Assuntos
Articulação do Cotovelo , Fixação Interna de Fraturas/instrumentação , Fraturas Intra-Articulares/cirurgia , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Adulto , Idoso , Remoção de Dispositivo , Feminino , Humanos , Fraturas Intra-Articulares/complicações , Fraturas Intra-Articulares/diagnóstico por imagem , Luxações Articulares/complicações , Luxações Articulares/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Resultado do Tratamento
11.
Tech Hand Up Extrem Surg ; 20(4): 155-160, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27801774

RESUMO

Locked volar plating is the most common surgical procedure to address distal radius fractures. The extended flexor carpi radialis approach continues to be an excellent method for visualizing distal radius fractures and applying a volar plate. A new understanding of the anatomy allows for better visualization and reduction of the many different distal radius fracture patterns surgeons commonly see. Within the extended flexor carpi radialis approach, we describe the radial septum in further detail including the anatomy which comprises the radial septum triangle. Knowledge of this area allows for better visualization, more anatomic reductions, and fewer complications.


Assuntos
Placas Ósseas , Dissecação/métodos , Fixação Interna de Fraturas/métodos , Placa Palmar , Fraturas do Rádio/cirurgia , Tendões/cirurgia , Humanos , Seleção de Pacientes
12.
J Wrist Surg ; 5(1): 17-21, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26855831

RESUMO

Background Articular fractures of the distal radius may include a small fragment from the volar margin of the lunate fossa: volar marginal fragments (VMFs); these fragments are prone to loss of fixation and avascular necrosis, and often result in wrist subluxation. We present our experience managing acute and delayed VMFs. The first is treated using a hook plate extension to a volar locking plate and the latter using a volar opening wedge osteotomy to redistribute loads on the remaining articular surface. Materials and Methods We retrospectively reviewed the records of all patients treated at our facility with a hook plate extension for a VMF and for patients treated with a volar opening wedge osteotomy. Medical charts were examined for complications and functional results. Technique A hook plate extension was used to fix the VMF when plate buttressing was insufficient. For patients who presented a collapsed and reabsorbed VMF, a volar opening wedge osteotomy was used to reorient the articular surface, restoring joint stability. Results The hook plate extension was successful in managing 19 of the 21 acute VMFs. The volar opening wedge osteotomy provided concentric reduction and improved pain and motion in all treated patients. Conclusion We demonstrated that hook plate fixation of the VMF is an effective means of fixing the acute VMF and that a volar opening wedge osteotomy can be used to salvage a distal radius fracture with a collapsed VMF.

14.
Clin Orthop Relat Res ; 472(7): 2049-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24789029

RESUMO

BACKGROUND: Nonsurgical and surgical treatments such as immobilization, transarticular pinning, and hinged or nonhinged external fixation have been used to treat unstable elbows. These methods all have drawbacks. We thought that a bent Steinmann pin introduced through the axis of ulnohumeral rotation and attached to the ulna could provide an improved method of treatment and that this could result in the development of a proper internal joint fixator that may have widespread application. QUESTIONS/PURPOSES: Does a fully internal hinged fixator crafted intraoperatively by the surgeon from a Steinmann pin for patients undergoing surgery for severe elbow instability result in restoration of range of motion and elbow stability? Does it result in new complications? METHODS: We reviewed the first 10 patients treated with the method for elbow instability. Diagnoses included fracture-dislocations of the elbow that remain unstable after fracture repair and unstable elbows that result from release of contracture or ulnohumeral synostosis. During that time, all patients meeting these criteria who underwent surgery by this surgeon (JLO) were treated with this approach. Charts, radiographs, and therapy notes were assessed at a minimum of 14 months (mean, 32 months; range, 14-59 months); no patients were lost to followup. Data recorded included age, sex, and elbow and forearm range of motion as well as any complications and reoperations that occurred. The absence of elbow instability was determined initially by radiographically observing concentric reduction of the ulnohumeral and radiocapitellar joints and later by radiography plus the absence of clinical signs and symptoms of elbow instability. RESULTS: Mean range of motion at latest followup was flexion 134°, extension -19°, pronation 75°, and supination 64°. All elbows were clinically and radiographically stable. Complications resulting in additional procedures occurred in four patients, including one recurrent deep infection in a patient with a remote history of sepsis, one wound hematoma that resolved after a drainage procedure performed in the office, one prominent implant treated by partial removal, and one patient with heterotopic ossification treated with excision of the heterotopic bone. CONCLUSIONS: This technique restores elbow stability and permits motion without the use of transcutaneous pins. It seems promising for the treatment of patients with severe elbow instability but requires a second procedure for removal. Further investigation is needed to understand its place in the surgeon's toolbox and what drawbacks it may have. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Pinos Ortopédicos , Articulação do Cotovelo/cirurgia , Traumatismos do Antebraço/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fixadores Internos , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos , Criança , Remoção de Dispositivo , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Feminino , Traumatismos do Antebraço/diagnóstico , Traumatismos do Antebraço/fisiopatologia , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/fisiopatologia , Humanos , Luxações Articulares/diagnóstico , Luxações Articulares/fisiopatologia , Instabilidade Articular/diagnóstico , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem , Lesões no Cotovelo
15.
J Wrist Surg ; 2(3): 247-54, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24436824

RESUMO

Background Intra-articular fractures of the distal radius represent a therapeutic challenge as compared with the unstable extra-articular fractures. With the recent development of specifically designed internal fixation materials for the distal radius, treatment of these fractures by fragment-specific implants using two or more incisions has been advocated. Purpose The purpose of this study was to investigate the efficacy of a fixed-angle locking plate applied through a single volar approach in maintaining the radiographic alignment of unstable intra-articular fractures as well as to report the clinical outcomes. We only excluded those with massive comminution, as is discussed in greater detail in the text. Patients and Methods This is a multicentered, retrospective study involving three hospitals situated in Spain, Switzerland, and the United States. In the period between January 2000 and March 2006, 97 patients with 101 intra-articular distal radius fractures, including 13 volarly displaced and 88 dorsally angulated fractures were analyzed. Over 80% were C2/C3 fractures, based on the AO classification. 16 open fractures were noted. Results With an average follow-up of 28 months (range 24-70 months), the range of movement of the wrist was very satisfactory, and the mean grip strength was 81% of the opposite wrist. The Disabilities of the Arm, Shoulder, and Hand (DASH) score was 8. The complications rate was < 5%, including loss of reduction in two patients. All fractures healed by 3 months postinjury. Conclusions Irrespective of the direction and amount of initial displacement, a great majority of intra-articular fractures of the distal radius can be managed with a fixed-angle volar plate through a single volar approach. Level IV retrospective case series.

16.
J Wrist Surg ; 1(2): 179-84, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24179725

RESUMO

Total wrist arthrodesis is commonly performed using fixation plates, which can produce soft tissue irritation, often require removal, and limit the ability to position the hand in space. The Skeletal Dynamics IMPLATE is an intramedullary total wrist fusion device designed to provide stable fixation while avoiding the problems associated with plates. Radial and metacarpal locked intramedullary nails are inserted and joined by a connector. Desired hand placement is achieved by selecting the proper connector length and angle, then orienting it appropriately. Fusion mass compression is obtained by virtue of longitudinal threads on the radial nail that allow for length adjustment. Seven wrists in three men and four women were treated with this device and followed for a minimum of 24 weeks. In all cases, local cancellous bone graft was used and the third carpometacarpal (CMC) joint incorporated into the fusion. The median age was 49 (range, 28-71) years. Indications for fusion were two posttraumatic arthritides, three rheumatoid arthritides, one spastic deformity, and one infection. Patients were evaluated before surgery and at final follow-up using the Fernandez pain score and grip strength measurements using a hand-held dynamometer. All patients improved their grip strength and decreased their pain scores. All fusions united, and none of the patients presented dorsal soft tissue problems or required implant removal. One rheumatoid patient required secondary surgery for removal of a retained palmar osteophyte. This device delivers stable fixation, facilitates hand placement, and does not require removal.

17.
Tech Hand Up Extrem Surg ; 13(3): 145-50, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19730044

RESUMO

We devised a new flap using the palmar cutaneous branch of the superficial radial artery proximally and anastomosed with a cutaneous perforator of the superficial palmar arch distally. We named our flap "the volar glabrous palmar flap." The flap was used both as a free flap and as a reverse-flow island flap. Thirty-six patients with volar hand defects (24 digits, 7 palms, and 5 first web space) were reconstructed with this flap. The flap was used as a proximally based free flap in 15 patients and was used as a reverse-flow island flap based on distal communication in the remaining 21 patients. Free flaps were supplied by the palmar branch of the superficial radial artery and its fasciocutaneous extensions; reverse-flow island flaps were supplied by one of the perforating branches of the superficial palmar arch, which is connected to the proximal fasciocutaneous branches. Flaps extended from the wrist crease to the proximal palmar crease and were designed medially on the thenar crease, extending 2 to 2.5 cm laterally. Flap sizes ranged from 1.5 x 2.2 cm to 2.5 x 10 cm. The palmar cutaneous branch of the median nerve within the flap area was identified and then was sutured to the divided digital nerve in 6 cases of finger pulp defect. The donor sites were closed and repaired primarily in most cases. The postoperative course was uneventful, and all the flaps survived without major complications. Follow-up (minimum 6 mo, mean 24 mo) showed excellent functional and cosmetic results. Satisfactory sensory reinnervation was achieved in patients who underwent sensory flap transfer for pulp defects. At the same time, we studied 6 cadaver hands to understand the vascular anatomy of the thenar area of the hand. We also revised several published anatomic papers to obtain a refined and scrutinized understanding of the palmar anatomy.


Assuntos
Fáscia/transplante , Traumatismos da Mão/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Transplante de Pele/métodos , Retalhos Cirúrgicos , Adolescente , Adulto , Criança , Estudos de Coortes , Feminino , Rejeição de Enxerto , Sobrevivência de Enxerto , Traumatismos da Mão/diagnóstico , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Prognóstico , Recuperação de Função Fisiológica , Medição de Risco , Lesões dos Tecidos Moles/diagnóstico , Lesões dos Tecidos Moles/cirurgia , Cicatrização/fisiologia , Adulto Jovem
18.
Clin Orthop Relat Res ; 445: 133-45, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16505726

RESUMO

UNLABELLED: This report cites new developments in the treatment of extra-articular hand fractures in adults. Recent reports confirm that small amounts of metacarpal shortening or dorsal angulation cause minimal functional impairment. Unilateral excision of the lateral band and oblique fibers of the extensor apparatus of the metacarpophalangeal joint facilitates proximal phalangeal fracture exposure and may improve functional recovery. Results using open mini screw fixation of oblique extra-articular metacarpal and phalangeal fractures may be comparable to those of percutaneous Kirschner wire fixation. Bicortical self-tapping mini screw fixation of extra-articular oblique metacarpal and phalangeal fractures simplifies screw insertion and provides stability comparable to that of fractures fixed with lag screws. Percutaneous intramedullary wire fixation may afford suitable fixation for unstable extra-articular oblique as well as transverse metacarpal fractures. Locked intramedullary nails may offer similar advantages. Unicortical screw fixation of mini plates securing transverse extra-articular metacarpal fractures affords stability comparable to that of bicortical screw fixation while creating less bone damage. The dissection required for plate fixation and the small surface area of transverse fractures delay and occasionally impair bone healing. Primary bone grafting of diaphyseal defects in clean stable wounds may shorten and simplify treatment and decrease morbidity. As little as 1.7 mm of flexor tendon excursion during the first 4 weeks after reduction or repair may substantially diminish peritendonous adhesions at the fracture site. Synchronous wrist and digital exercises may also reduce peritendonous fracture adhesions. Early motion of adjacent joints in closed simple metacarpal fractures expedites recovery of motion and strength without adversely affecting fracture alignment and leads to earlier return to work. LEVEL OF EVIDENCE: Level V (expert opinion).


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Fechadas/cirurgia , Traumatismos da Mão/cirurgia , Ossos Metacarpais/lesões , Placas Ósseas , Parafusos Ósseos , Fios Ortopédicos , Traumatismos dos Dedos/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Traumatismos da Mão/diagnóstico por imagem , Humanos , Ossos Metacarpais/diagnóstico por imagem , Procedimentos Cirúrgicos Minimamente Invasivos , Radiografia
19.
Tech Hand Up Extrem Surg ; 9(3): 142-8, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16175117

RESUMO

Treating unstable distal radius fractures in osteoporotic patients remains a challenge for the surgeon. Fixed angle plate fixation requires ample surgical dissection but has been shown to improve stability, allow early functional use of the hand and facilitate rehabilitation. We herein describe a treatment method that provides the benefits of fixed angle fixation while utilizing a minimally invasive approach. Stability is achieved by the use of a new implant that is placed through a small dorsal incision and minimizes extensor tendon disruption. This method finds application in the unstable extra-articular fracture of the high risk patient where minimal surgical morbidity is desirable and when reduction can be obtained without the need of extensive dissection. Clinical examples are fractures in the elderly patient where confusion can follow prolonged anesthesia, fractures in the patient with a bleeding disorder where a small wound volume is desirable and fractures in the polytraumatized patient where surgical time must be kept to a minimum. This technique allows anatomic reduction and stable fixation to be achieved in a short operative time and with minimal surgical insult while providing the compromised patient with a rapid recovery.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteoporose/complicações , Osteoporose/cirurgia , Modalidades de Fisioterapia , Fraturas do Rádio/complicações
20.
J Hand Surg Am ; 30(1): 154-60, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15680573

RESUMO

PURPOSE: Many skeletal traction devices have been described to treat fracture dislocations of the proximal interphalangeal (PIP) joint. Most of these techniques are technically challenging or involve cumbersome frames. We present a design modification that enhances the stability of a simple dynamic fixation system described previously and report our results with this technique. METHODS: A previously described simple dynamic fixator with no rubber bands was applied to 6 patients who sustained fracture dislocations of the PIP joint. The middle finger was involved in 3 patients, the ring finger in 1 patient, and the small finger in 2 patients. The average age of the patients was 27 years (range, 21-42 y). The average involvement of the base of the middle phalanx was 48% (range, 35% to 60%). The average time from the injury to the surgery was 6 days (range, 1-14 d). The average follow-up period was 24 months (range, 7-43 mo). Immediate active flexion extension was allowed and the fixator was removed after 3 to 4 weeks. RESULTS: The average range of motion of the PIP joint at the final follow-up evaluation was 5 degrees to 89 degrees (range, 0 degrees to 100 degrees ). Two patients developed pin track infection that resolved with oral antibiotics. Only one patient complained of mild pain with extreme flexion. Proper reduction and congruency of the joint was noted on final anteroposterior and lateral radiographs. CONCLUSIONS: A simple dynamic fixator for the treatment of unstable PIP joint fracture dislocations was used successfully in 6 digits to maintain reduction and restore digital range of motion. The addition of modifications to the original technique not only improves the solidity of the construct but also provides satisfactory functional results. Based on our experience we recommend this easy technique to treat fracture dislocations of the PIP joint.


Assuntos
Fixadores Externos , Traumatismos dos Dedos/cirurgia , Articulações dos Dedos/cirurgia , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Luxações Articulares/cirurgia , Adulto , Desenho de Equipamento , Feminino , Traumatismos dos Dedos/fisiopatologia , Articulações dos Dedos/fisiopatologia , Fraturas Ósseas/fisiopatologia , Humanos , Luxações Articulares/fisiopatologia , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Masculino , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA