Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Chim Acta ; 554: 117782, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38224930

RESUMO

BACKGROUND AND AIMS: To investigate the contribution of FGF23 in explaining the cases of hypophosphatemia observed in clinical practice, we aimed to determine for the first time the prevalence of FGF23 elevation in patients with hypophosphatemia and to describe the different mechanisms of FGF23-related hypophosphatemic disorders. MATERIALS AND METHODS: We performed a prospective, observational, multicenter, cohort study of 260 patients with hypophosphatemia. Blood measurements (PTH, 1,25-dihydroxyvitamin D, bone alkaline phosphatase, 25-hydroxyvitamin D, and FGF23) were performed on a Liaison XL® (DiaSorin) analyzer. RESULTS: Primary elevation of FGF23 (>95.4 pg/mL) was reported in 10.4% (95CI: 7.0-14.7) of patients (n = 27) with hypophosphatemia, suggesting that at least 1 in 10 cases of hypophosphatemia was erroneously attributed to an etiology other than FGF23 elevation. Patients with elevated blood FGF23 were grouped according to the etiology of the FGF23 elevation. Thus, 10 patients had a renal pathology, chronic kidney disease or post-renal transplantation condition. The remaining patients (n = 17) had the following etiologies: malignancies (n = 9), benign pancreatic tumor (n = 1), post-cardiac surgery (n = 4), cirrhosis (n = 2), and chronic obstructive pulmonary disease (n = 1). CONCLUSION: In order to improve patient management, it seems essential to better integrate plasma FGF23 measurement into the routine evaluation of hypophosphatemia.


Assuntos
Hipofosfatemia , Humanos , Calcifediol , Estudos de Coortes , Fatores de Crescimento de Fibroblastos , Hipofosfatemia/epidemiologia , Hipofosfatemia/etiologia , Fosfatos , Prevalência , Estudos Prospectivos
2.
J Clin Endocrinol Metab ; 108(11): 3031-3040, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37235783

RESUMO

CONTEXT: Tumor-induced osteomalacia (TIO) due to fibroblast growth factor 23 (FGF23) overexpression is becoming recognized in patients with malignancy. The condition may be underdiagnosed, with a scarce medical literature. OBJECTIVE: To perform a meta-analysis of case reports to allow a better understanding of malignant TIO and its clinical implications. METHODS: Full texts were selected according to strict inclusion criteria. All case reports were included where patients had hypophosphatemia, malignant TIO, and FGF23 blood levels. Thirty-two of 275 eligible studies (n = 34 patients) met inclusion criteria. A list of desired data was extracted and graded for methodological quality. RESULTS: Prostate adenocarcinoma (n = 9) were the most tumors reported. Twenty-five of 34 patients had a metastatic disease and a poor clinical outcome was reported for 15 of 28 patients. The median levels of blood phosphate and C-terminal FGF23 (cFGF23) were 0.40 mmol/L and 788.5 RU/mL, respectively. For most of patients, blood PTH was elevated or within range, and calcitriol levels were inappropriately low or normal. Alkaline phosphatase concentrations were increased for 20 of 22 patients. The cFGF23 values were significantly higher for patients with a poor clinical outcome when compared to other patients (1685 vs 357.5 RU/mL). In case of prostate cancer, cFGF23 levels were significantly lower (429.4 RU/mL) than for other malignancies (1007.5 RU/mL). CONCLUSION: We report for the first time a detailed description of the clinical and biological characteristics of malignant TIO. In this context, FGF23 blood measurement would be of value for the diagnostic workup, prognostication, and follow-up of patients.


Assuntos
Hipofosfatemia , Osteomalacia , Síndromes Paraneoplásicas , Humanos , Masculino , Calcitriol , Fatores de Crescimento de Fibroblastos , Hipofosfatemia/diagnóstico , Hipofosfatemia/etiologia , Osteomalacia/metabolismo , Síndromes Paraneoplásicas/diagnóstico , Síndromes Paraneoplásicas/etiologia , Relatos de Casos como Assunto
3.
Ann Biol Clin (Paris) ; 80(5): 487-493, 2022 09 01.
Artigo em Francês | MEDLINE | ID: mdl-36453737

RESUMO

A 65-year-old female was admitted to the Emergency Department for a fall. Upon admission, a blood sample was drawn for routine laboratory tests. Blood glucose measurement using the hexokinase method was made impossible due to a high lipemia index measured by the instrument despite a clear plasma specimen. It is well known that hemolysis, icterus, and lipemia interferences disrupt spectrophotometric quantifications. However, in this case, the absence of lipemia was confirmed by plasma triglycerides measurement in the normal reference range. Protein electrophoresis along with an immunofixation were carried out to characterize a monoclonal gammopathy since the presence of a monoclonal gammopathy in very high concentrations generates turbidity and interferes with spectrophotometric assays. A gamma peak evoking a monoclonal gammopathy was found on the serum electrophoresis and the immunofixation was positive for a monoclonal IgM kappa. Myelogram showed plasmocytes, lymphoplasmacytic cells and mast cells infiltration which led to the diagnosis of Waldenstrom macroglobulinemia. Based on this case, we propose a course of action to be taken in the case of a high lipemia index and clear plasma.


Une femme de 65 ans est admise aux urgences pour une chute. À l'admission, un échantillon de sang a été prélevé pour réaliser un bilan biologique de routine. Sur ce bilan, la mesure spectrophotométrique de la glycémie par la méthode de l'hexokinase était impossible en raison d'un indice de lactescence trop élevé et ce malgré un plasma d'aspect clair. Il est bien connu que l'hémolyse, l'ictère et la lactescence interfèrent dans le dosage spectrophotométrique. Cependant, dans ce cas, il n'y a pas de perturbation du bilan lipidique chez la patiente. Une prestation de conseil a donc été réalisée par le service de biochimie afin de recommander la réalisation d'une électrophorèse des protéines sériques car la présence d'une gammapathie monoclonale à des concentrations très élevées génère de la turbidité et interfère avec les dosages spectrophotométriques. Un pic dans la fraction des gammaglobulines évoquant une gammapathie monoclonale a été retrouvé sur l'électrophorèse sérique, l'immunofixation confirme la présence d'une IgM kappa monoclonale. Le myélogramme montre une infiltration de plasmocytes, de lymphoplasmocytes et de mastocytes ce qui a conduit au diagnostic de maladie de Waldenström. Sur la base de ce cas, nous proposons une conduite à tenir en cas d'indice de lactescence élevé avec un plasma d'aspect clair.


Assuntos
Gamopatia Monoclonal de Significância Indeterminada , Macroglobulinemia de Waldenstrom , Feminino , Humanos , Idoso , Macroglobulinemia de Waldenstrom/complicações , Macroglobulinemia de Waldenstrom/diagnóstico , Gamopatia Monoclonal de Significância Indeterminada/complicações , Gamopatia Monoclonal de Significância Indeterminada/diagnóstico , Plasmócitos , Bioensaio
4.
PLoS One ; 17(8): e0272835, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36001593

RESUMO

BACKGROUND: Proteinuria results from kidney damage and can be a predictor of illness severity and mortality in the intensive care unit (ICU). However, the optimal timing of proteinuria measurements and the reference values remain undetermined. Our objective was to identify the patterns of proteinuria change associated with mortality in ICU patients with sepsis or shock. METHODS: This monocentric retrospective cohort study performed from April 2010 to April 2018 involved all ICU patients with sepsis or shock and at least two measurements of proteinuria from a 24h-urine collection during the first 10 days of ICU stay, the first of which was made within 48h after ICU admission. We identified proteinuria trajectories by a semi-parametric mixture model and analysed the association between the trajectories and the mortality at day 28 by Cox proportional-hazards model. RESULTS: A total of 3,344 measurements of proteinuria from 659 patients were analysed. Four proteinuria trajectories were identified. Trajectories 1, 2, 3 and 4 comprised 127, 421, 60 and 51 patients, and were characterized by a first proteinuria of 1.14 [0.66-1.55], 0.52 [0.26-0.91], 2.92 [2.38-3.84] and 2.58 [1.75-3.32] g/24h (p<0.001) and a mortality of 24.4%, 38%, 20% and 43% (p = 0.002), respectively. Trajectories 3 and 4 had a high first proteinuria (>2g/24h). Only, the proteinuria of trajectory 4 increased within 3 days following the first measurement and was associated with increased mortality at day 28 (hazard ratio: 2.36 95%CI [1.07-5.19], p = 0.03), regardless of acute renal failure. The factors associated with trajectory 4 were cancer (relative risk: 8.91 95%CI [2.09-38.02], p = 0.003) and use of inotropic drugs (relative risk: 0.17 95%CI [0.04-0.69], p = 0.01). CONCLUSION: This exploratory study of ICU patients with sepsis or shock identified four proteinuria trajectories with distinct patterns of proteinuria change over time and mortality rates. These results provide novel insights into renal pathophysiology and may be helpful to investigate subphenotypes of kidney injury among ICU patients in future studies.


Assuntos
Sepse , Choque , Estado Terminal , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Proteinúria/complicações , Estudos Retrospectivos , Sepse/complicações
5.
Clin Biochem ; 104: 62-65, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35337828

RESUMO

BACKGROUND: Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome characterized by hypophosphatemia associated with elevated fibroblast growth factor 23 (FGF23). TIO is primarily caused by benign mesenchymal tumors of the soft tissue and skeleton. Rarely, it is associated with a solid tumor or hematological malignancy. To date, no case of osteomalacia related to pancreatic cancer has been reported in the literature. CASE REPORT: A 77-year-old woman was admitted to the rheumatology department (RD) of the Clermont-Ferrand University Hospital (France) for further evaluation of her hypophosphatemia. The patient reported bone pain, myalgia, and asthenia. Further laboratory tests revealed hyperphosphaturia, normocalcemia, low serum calcitriol, elevated serum alkaline phosphatase (ALP), and elevated plasma parathyroid hormone (PTH). A renal phosphate depletion disorder was suspected as an etiology for this hypophosphatemia. Finally, FGF23 levels were found to be significantly elevated, leading to a definitive diagnosis of pancreatic neuroendocrine tumor. CONCLUSION: This is the first report of hypophosphatemic osteomalacia related to pancreatic cancer. Therefore, in the setting of hypophosphatemia associated with renal phosphate wasting and low calcitriol level, plasma FGF23 measurement should be considered.


Assuntos
Doenças do Sistema Endócrino , Hipofosfatemia , Osteomalacia , Neoplasias Pancreáticas , Idoso , Calcitriol , Feminino , Fatores de Crescimento de Fibroblastos , Humanos , Hipofosfatemia/etiologia , Osteomalacia/etiologia , Osteomalacia/metabolismo , Osteomalacia/patologia , Neoplasias Pancreáticas/complicações , Síndromes Paraneoplásicas , Fosfatos
6.
Ann Clin Biochem ; 58(1): 54-65, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33026828

RESUMO

BACKGROUND: Thyroglobulin (Tg) assay in washout fluids of fine needles, after cervical lymph nodes aspiration, is used for detecting metastases from differentiated thyroid carcinomas. Assay methods are the same as for Tg in serum. However, with non-serum samples, methods require extensive validation to notably check for the absence of matrix effect. This study fits this context. Our objectives were to assess analytic performances, in washout fluid, of eight different Tg assay methods and to compare them to validated data in serum. METHODS: Eleven medical laboratories participated in this study. The matrix tested was phosphate-buffer saline containing 1% bovine serum albumin (PBS-1% BSA). Samples used were dilutions, in this buffer, of Certified Reference Material (CRM 457). We verified, for all methods, the limit of detection, precision, linearity, trueness and accuracy. RESULTS: In PBS-1% BSA, the functional sensitivities (FS) were comparable to those expected for serum. All the methods were linear. The relative biases of trueness were between -24.5 and 10.2% around 1 µg/L. Total analytical error was ≤40% near the functional sensitivity values. CONCLUSION: No quantitatively important matrix effect was observed. All the methods showed their ability to measure Tg in PBS-1% BSA, over the concentration range of interest, with acceptable total analytical error. We validated the functional sensitivity value as a decision threshold in thyroidectomized patients after treatment and with low concentrations of serum Tg.


Assuntos
Proteínas de Neoplasias/metabolismo , Tireoglobulina/metabolismo , Neoplasias da Glândula Tireoide/metabolismo , Biópsia por Agulha Fina , Feminino , Humanos , Masculino , Neoplasias da Glândula Tireoide/patologia
7.
Ann Biol Clin (Paris) ; 78(1): 93-107, 2020 02 01.
Artigo em Francês | MEDLINE | ID: mdl-32108587

RESUMO

The measurement performance of 13 biochemistry parameters (CEA, CA 19-9, amylase, lipase, sodium, potassium, chloride, creatinine, glucose, protein, albumin, LDH, triglycerides) was tested in a panel of biological fluids other than blood and urine (peritoneal, pleural, pancreatic fluids ...). Our protocol, based on a risk analysis, allowed us to justify our choices and compare the performance obtained with those of the serum or plasma matrix already validated. Thus, the coefficients of variation obtained in body fluids are comparable. The assessment of accuracy (spiking and dilution tests) shows the absence of bias, which is consistent with the absence of matrix effect. The linearity studied by dilution tests shows that the upper limits of the measurement interval communicated by the supplier are applicable to body fluids. The absence of contamination and stability have been also confirmed. All analytes are stable for 3 days at room temperature, 7 days between 2 and 8̊C, and 6 months at -20̊C; except LDH and lipase. For most analytes, at least one interference (hemolysis, icterus, lipemia) was found. Finally, a bibliographical study, confronted with the experience of prescribers, led us to define optimal thresholds to help interpret patients' results. In conclusion, this work has allowed us to validate analytical methods for body fluids testing after relying on their comparability to the blood matrix. We have also been able to adapt our practices and finally be accredited according to the standard NF IN ISO 15189.


Assuntos
Biomarcadores/análise , Líquidos Corporais/química , Técnicas de Laboratório Clínico , Albuminas/análise , Albuminas/metabolismo , Amilases/análise , Amilases/metabolismo , Biomarcadores/metabolismo , Líquidos Corporais/metabolismo , Antígeno CA-19-9/análise , Antígeno CA-19-9/metabolismo , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/metabolismo , Cloretos/análise , Cloretos/metabolismo , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Creatinina/análise , Creatinina/metabolismo , Glucose/análise , Glucose/metabolismo , Humanos , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/metabolismo , Lipase/análise , Lipase/metabolismo , Potássio/análise , Potássio/metabolismo , Proteínas/análise , Proteínas/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sódio/análise , Sódio/metabolismo , Temperatura , Triglicerídeos/análise , Triglicerídeos/metabolismo
8.
Pract Lab Med ; 10: 21-33, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29487890

RESUMO

BACKGROUND: Blood gas analyzers are o0.ften integrated into point-of-care testing provisions. International standards (ISO 22870 and 15189) as adapted to French COFRAC regulations make accreditation of point-ofta-care testintag obligatory. We installed and assessed 12 GEM PREMIER 4000 analyzers for pH, pCO2, pO2, Na+, K+, Cl-, Ca2+, lactate, hemoglobin and oxyhemoglobin (O2Hb) at Clermont-Ferrand Hospital. These instruments were distributed across 11 care sites in the hospital. METHODS: Precision was studied at two control levels for each parameter. Comparisons between GEM analyzers were performed (on 30 samples) for pH, pCO2, pO2, Na+, K+, Cl-, Ca2+, lactate, hemoglobin and O2Hb; and between GEM analyzers and the central laboratory for Na+, K+, Cl-, Ca2+ and hemoglobin (on 30-50 samples). Uncertainty in measurement (UM) was evaluated with an approach using reproducibility and accuracy data. RESULTS: The coefficients of variation (CVs) were in line with recommendations, except for the repeatability CV for pO2. All CVs were below 4%. All comparisons complied with recommendations. Uncertainties of measurement were also validated. CONCLUSION: Our results met standard requirements and the 12 analyzers were assessed as suitable for point-of-care testing in services of academic medical centers, as exemplified at Clermont-Ferrand hospital.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA