1.
Phys Med Biol ; 66(6): 065005, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-32268312

RESUMO

X-ray phase contrast imaging can provide improved or complementary information to traditional attenuation-based X-ray imaging, making the field a vast and rapidly evolving research subject. X-ray speckle-based imaging (SBI) is one phase-contrast imaging approach that has shown significant potential in providing both high sensitivity and high resolution while using a very simple experimental setup. With the aim of transferring such phase-contrast-based imaging techniques from synchrotron to laboratory X-ray sources, the issue of the deposited radiation dose still remains to be addressed. In this work, we experimentally and quantitatively compare the results from three different SBI phase retrieval algorithms using both phantoms and biological samples in order to infer the optimal configuration. The results obtained using a synchrotron beam suggest that the technique based on optical flow conservation achieves the most accurate retrieval from the lowest number of sample exposures. This constitutes an important step toward the possibility of transferring SBI into the clinic.


Assuntos
Microscopia de Contraste de Fase/métodos , Doses de Radiação , Radiografia/métodos , Radiometria/métodos , Síncrotrons , Raios X , Algoritmos , Desenho de Equipamento , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade
2.
PLoS One ; 8(1): e55822, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23383288

RESUMO

In the airways of those with cystic fibrosis (CF), the leading pathophysiological hypothesis is that an ion channel defect results in a relative decrease in airway surface liquid (ASL) volume, producing thick and sticky mucus that facilitates the establishment and progression of early fatal lung disease. This hypothesis predicts that any successful CF airway treatment for this fundamental channel defect should increase the ASL volume, but up until now there has been no method of measuring this volume that would be compatible with in vivo monitoring. In order to accurately monitor the volume of the ASL, we have developed a new x-ray phase contrast imaging method that utilizes a highly attenuating reference grid. In this study we used this imaging method to examine the effect of a current clinical CF treatment, aerosolized hypertonic saline, on ASL depth in ex vivo normal mouse tracheas, as the first step towards non-invasive in vivo ASL imaging. The ex vivo tracheas were treated with hypertonic saline, isotonic saline or no treatment using a nebuliser integrated within a small animal ventilator circuit. Those tracheas exposed to hypertonic saline showed a transient increase in the ASL depth, which continued for nine minutes post-treatment, before returning to baseline by twelve minutes. These findings are consistent with existing measurements on epithelial cell cultures, and therefore suggest promise for the future development of in vivo testing of treatments. Our grid-based imaging technique measures the ASL depth with micron resolution, and can directly observe the effect of treatments expected to increase ASL depth, prior to any changes in overall lung health. The ability to non-invasively observe micron changes in the airway surface, particularly if achieved in an in vivo setting, may have potential in pre-clinical research designed to bring new treatments for CF and other airway diseases to clinical trials.


Assuntos
Fibrose Cística/diagnóstico por imagem , Líquido Extracelular , Mucosa Respiratória/metabolismo , Animais , Fibrose Cística/terapia , Feminino , Técnicas In Vitro , Camundongos , Radiografia , Fatores de Tempo , Traqueia/metabolismo
3.
Ultramicroscopy ; 111(7): 768-76, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21177037

RESUMO

Transient optical gratings for detecting ultrafast signals are routine for temporally resolved photochemical investigations. Many processes can contribute to the formation of such gratings; we indicate use of optically scattering centres that can be formed with highly variable latencies in different materials and devices using ionising radiation. Coherent light scattered by these centres can form the short-wavelength-to-optical-wavelength, incoherent-to-coherent basis of a Bragg X-ray microscope, with inherent scope for optical phasing. Depending on the dynamics of the medium chosen, the way is open to both ultrafast pulsed and integrating measurements. For experiments employing brief pulses, we discuss high-dynamic-range short-wavelength diffraction measurements with real-time optical reconstructions. Applications to optical real-time X-ray phase-retrieval are considered.


Assuntos
Microanálise por Sonda Eletrônica/métodos , Microscopia/métodos , Radiação Ionizante , Processamento de Imagem Assistida por Computador/métodos , Fótons , Espectrometria por Raios X/métodos , Difração de Raios X/métodos , Raios X
4.
Phys Med Biol ; 50(15): 3599-611, 2005 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-16030385

RESUMO

We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Lesões Pré-Cancerosas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias da Mama/complicações , Neoplasias da Mama/patologia , Calcinose/complicações , Calcinose/patologia , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS