Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Blood ; 142(26): 2305-2314, 2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-37883798

RESUMO

ABSTRACT: Platelet-activating anti-platelet factor 4 (PF4)/heparin antibodies and anti-PF4 antibodies cause heparin-induced thrombocytopenia (HIT) and vaccine-induced immune thrombocytopenia and thrombosis (VITT), respectively. Diagnostic and treatment considerations differ somewhat between HIT and VITT. We identified patients with thrombocytopenia and thrombosis without proximate heparin exposure or adenovirus-based vaccination who tested strongly positive by PF4/polyanion enzyme-immunoassays and negative/weakly positive by heparin-induced platelet activation (HIPA) test but strongly positive by PF4-induced platelet activation (PIPA) test (ie, VITT-like profile). We tested these patients by a standard chemiluminescence assay that detects anti-PF4/heparin antibodies found in HIT (HemosIL AcuStar HIT-IgG(PF4-H)) as well as a novel chemiluminescence assay for anti-PF4 antibodies found in VITT. Representative control sera included an exploratory anti-PF4 antibody-positive but HIPA-negative/weak cohort obtained before 2020 (n = 188). We identified 9 patients with a clinical-pathological profile of a VITT-like disorder in the absence of proximate heparin or vaccination, with a high frequency of stroke (arterial, n = 3; cerebral venous sinus thrombosis, n = 4), thrombocytopenia (median platelet count nadir, 49 × 109/L), and hypercoagulability (greatly elevated D-dimer levels). VITT-like serological features included strong reactivity by PIPA (aggregation <10 minutes in 9/9 sera) and positive testing in the novel anti-PF4 chemiluminescence assay (3/9 also tested positive in the anti-PF4/heparin chemiluminescence assay). Our exploratory cohort identified 13 additional patient sera obtained before 2020 with VITT-like anti-PF4 antibodies. Platelet-activating VITT-like anti-PF4 antibodies should be considered in patients with thrombocytopenia, thrombosis, and very high D-dimer levels, even without a proximate exposure to heparin or adenovirus vector vaccines.


Assuntos
Anticorpos , Trombocitopenia , Trombose , Trombocitopenia/diagnóstico , Trombocitopenia/patologia , Heparina , Vacinação , Humanos , Fator Plaquetário 4/metabolismo , Anticorpos/análise , Masculino , Feminino , Pré-Escolar , Criança , Adulto , Trombose/diagnóstico , Trombose/patologia
2.
Int J Cancer ; 133(10): 2383-91, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23649867

RESUMO

Rapid and reliable diagnosis of endometrial cancer (EC) in uterine aspirates is highly desirable. Current sensitivity and failure rate of histological diagnosis limit the success of this method and subsequent hysteroscopy is often necessary. Using quantitative reverse transcriptase-polymerase chain reaction on RNA from uterine aspirates samples, we measured the expression level of 20 previously identified genes involved in EC pathology, created five algorithms based on combinations of five genes and evaluated their ability to diagnose EC. The algorithms were tested in a prospective, double-blind, multicenter study. We enlisted 514 patients who presented with abnormal uterine bleeding. EC was diagnosed in 60 of the 514 patients (12%). Molecular analysis was performed on the remnants of aspirates and results were compared to the final histological diagnoses obtained through biopsies acquired by aspiration or guided by hysteroscopy, or from the specimens resected by hysterectomy. Algorithm 5 was the best performing molecular diagnostic classifier in the case-control and validation study. The molecular test had a sensitivity of 81%, specificity of 96%, positive predictive value (PPV) of 75% and negative predictive value (NPV) of 97%. A combination of the molecular and histological diagnosis had a sensitivity of 91%, specificity of 97%, PPV of 79% and NPV of 99% and the cases that could be diagnosed on uterine aspirate rose from 76 to 93% when combined with the molecular test. Incorporation of the molecular diagnosis increases the reliability of a negative diagnosis, reduces the need for hysteroscopies and helps to identify additional cases.


Assuntos
Neoplasias do Endométrio/diagnóstico , Neoplasias Uterinas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Estudos de Casos e Controles , Método Duplo-Cego , Neoplasias do Endométrio/patologia , Feminino , Humanos , Histerectomia/métodos , Histeroscopia/métodos , Pessoa de Meia-Idade , Patologia Molecular/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Hemorragia Uterina/diagnóstico , Hemorragia Uterina/patologia , Neoplasias Uterinas/genética , Neoplasias Uterinas/patologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA