Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 102(13): 1177-1185, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32618925

RESUMO

BACKGROUND: To enhance osseointegration in total hip arthroplasty (THA), ultraporous or highly porous-coated cups were introduced. Implant survival data on these new devices have been scarce. The aim of our study was to assess the survivorship of ultraporous Tritanium cups (Stryker) in a population-based register study. METHODS: In this study, we collected data on 6,080 primary THAs using a Tritanium cup and 25,670 THAs using a conventional cup (control group) from the Finnish Arthroplasty Register; these procedures were performed from January 1, 2009, to December 31, 2017. We calculated the Kaplan-Meier survival estimates with 95% confidence intervals (CIs). The end point was revision for any reason or for aseptic loosening of the cup. The revision risks were assessed with use of the Cox multiple regression model. The variables assessed in the Cox model were femoral head size, age group, involved side, operation year, sex, diagnosis, and fixation of the stem. The proportional hazards assumption of the Cox model was not fulfilled, so the follow-up time was divided into 3 time periods: 0 to 2 years, >2 to 4 years, and >4 years. RESULTS: When comparing the 2 groups with regard to revision for any reason, the 5-year Kaplan-Meier survivorship of the Tritanium group (94.7% [95% CI, 94.0% to 95.4%]) was inferior to that of the control group (96.0% [95% CI, 95.7% to 96.3%]). In the Cox regression analysis of the 2 groups for the time period of >4 years, the Tritanium group had an increased risk of revision for any reason compared with the control group (hazard ratio [HR], 3.12 [95% CI, 1.82 to 5.35]; p < 0.001). With regard to revision for aseptic loosening of the cup, the Tritanium group had an increased risk of revision compared with the control group for both 0 to 2 years (HR, 3.80 [95% CI, 1.76 to 8.24]; p < 0.001) and >2 to 4 years (HR, 11.2 [95% CI, 3.28 to 38.0]; p < 0.001). CONCLUSIONS: There was no advantage to using the ultraporous-coated Tritanium cup for primary THA compared with conventional uncemented cups. However, wide CIs for some HR estimates may point to a lack of precision. Therefore, further research on subject is needed. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/cirurgia , Prótese de Quadril , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Falha de Prótese , Sistema de Registros
2.
Arch Orthop Trauma Surg ; 137(3): 311-320, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28091739

RESUMO

INTRODUCTION: Total hip arthroplasty (THA) with uncemented implants has been a relatively common procedure in Finland during the recent decades. The most common brand of uncemented implants was chosen for further analysis to study the survivorship of this uncemented cup design in comparison to cemented references. PATIENTS, MATERIALS AND METHODS: Since 1980, The Finnish Arthroplasty Register has collected information on THAs on a national level. This study was based on information of THAs recorded in the Finnish Arthroplasty Register from 1985 to 2013. If patient had undergone bilateral THA, only the first one was included. Altogether, 49,289 THAs were included. RESULTS: The overall 10-year implant survivorship of uncemented implants was 84.3% (95% CI 83.5-85.0%) and of cemented implants 90.6% (90.2-90.0%). The 10-year survival of the contemporary uncemented implants was 90.8% (94.0-95.5%) and 88.5% (84.2-91.7%). The most recently introduced uncemented cup designs had good survivorship rates at 5 years; 10-year survival data are not yet available. CONCLUSIONS: We found that modern uncemented cup designs may provide good long-term survivorship rates comparable with the gold standard of cemented cups. However, polyethylene wear, liner problems and periosthetic osteolysis may still occur, also with modern uncemented acetabular components.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Polietileno , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA