Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Retina ; 44(5): 782-790, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237083

RESUMO

PURPOSE: To evaluate the incidence, associated factors, and outcome of persistent subretinal fluid (SRF) after vitrectomy for macular hole-associated retinal detachment (MHRD). METHODS: A total of 158 eyes from 156 patients with MHRD who achieved macular hole closure after primary vitrectomy were included in the analysis; persistent SRF was defined as the presence of SRF for more than 1 month after first surgery. Preoperative and postoperative parameters were analyzed for their relationship with SRF development. RESULTS: Persistent SRF was observed in 19 eyes (12.0% of 158) postoperatively. Seven eyes (36.8% of 19) with persistent SRF eventually displayed complete absorption during follow-up. Univariate analysis revealed that eyes with persistent SRF were statistically associated with internal limiting membrane inverted flap, duration of symptoms, tamponade (perfluoropropane/silicone oil: 14/5 vs. 35/104, P < 0.001), and MHRD subtype (Type 1/Type 2/Type 3: 15/4/0 vs. 60/40/39, P = 0.003). In multivariate analysis, only internal limiting membrane inverted flap (odds ratio, 15.778, 95% confidence interval, 3.170-78.523; P = 0.001) was positively associated with persistent SRF. There were no significant differences in best-corrected visual acuity improvement ( P = 0.425) between the SRF involved foveal and without involved foveal groups and no significant differences between the SRF complete absorption and incomplete absorption groups. CONCLUSION: Absorption of persistent SRF may be more difficult in MHRD eyes than in ordinary rhegmatogenous retinal detachment eyes. The internal limiting membrane inverted flap in MHRD was associated with a greater likelihood of persistent SRF. The location and incomplete absorption of persistent SRF did not seem to be associated with the final visual outcome.


Assuntos
Tamponamento Interno , Descolamento Retiniano , Perfurações Retinianas , Líquido Sub-Retiniano , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Masculino , Feminino , Perfurações Retinianas/cirurgia , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/etiologia , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Tamponamento Interno/métodos , Tomografia de Coerência Óptica/métodos , Complicações Pós-Operatórias , Seguimentos , Fluorocarbonos/administração & dosagem , Incidência
2.
Acta Ophthalmol ; 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37818952

RESUMO

PURPOSE: To identify prognostic factors for complete anatomical success (CAS) under different axial length (AL) conditions after vitrectomy plus internal limiting membrane (ILM) peeling for retinal detachment associated with macular hole (MHRD). METHODS: This retrospective study included 243 patients (251 eyes) with MHRD who underwent primary vitrectomy plus ILM peeling. Multivariate logistic regression explored prognostic factors for CAS in AL <30 mm and ≥ 30 mm groups. RESULTS: Overall, 113 eyes (45.0% of 251) exhibited complete CAS after initial surgery. Eyes with CAS had greater best-corrected visual acuity improvement than eyes without CAS (p < 0.001). CAS was more common in eyes with AL < 30 mm (50.3% of 155) than in eyes with AL ≥ 30 mm (36.5%, 35/96; p = 0.032). In the AL < 30 mm group, CAS was associated with ILM insertion (odds ratio [OR], 2.824, 95% confidence interval [CI], 1.189-6.710; p = 0.019), silicone oil (SO)/perfluoropropane (C3F8) tamponade (SO: OR, 0.408, 95% CI, 0.191-0.873; C3F8: OR, 2.448, 95% CI, 1.145-5.234; p = 0.021) and staphyloma (OR, 0.318, 95% CI, 0.143-0.707; p = 0.005). In the AL ≥30 mm group, CAS was associated with ILM insertion (OR, 11.621, 95% CI, 2.557-52.813; p = 0.001), SO /C3F8 tamponade (SO: OR, 5.305, 95% CI, 1.206-23.334; C3F8: OR, 0.188, 95% CI, 0.043-0.829; p = 0.027) and age (OR, 0.928, 95% CI, 0.876-0.983; p = 0.011). CONCLUSION: Vitrectomy plus ILM peeling can effectively treat MHRD but has limited efficacy in eyes with AL ≥ 30 mm. ILM insertion was associated with more frequent CAS at any AL. C3F8 tamponade yielded better outcomes with AL < 30 mm; SO tamponade yielded better outcomes with AL ≥ 30 mm.

3.
Int J Ophthalmol ; 16(2): 215-223, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36816206

RESUMO

AIM: To identify the risk factors for postoperative proliferative vitreoretinopathy (PVR) in patients with primary rhegmatogenous retinal detachment (RRD) and develop a nomogram for predicting postoperative PVR-free probability. METHODS: A total of 741 patients (741 eyes) diagnosed with primary RRD who underwent first surgery in the same hospital were retrospectively reviewed and randomly assigned with 521 to the training set and 220 to the validation set. Univariate and multivariate logistic regression analyses were performed in the training cohort to determine risk factors to construct a nomogram for predicting the 3-, 4-, 5-, and 6-month postoperative PVR-free probabilities. Nomogram performance was estimated by the concordance index (C-index), calibration plot, and the area receiver operating characteristic (ROC) curve. RESULTS: A nomogram was constructed based on the preoperative PVR, silicone oil tamponade time (SOTT), photocoagulation energy (PE), retinal tear size (RTS), and hypertension. In the training set, the C-index of the nomogram was 0.896, 0.936, 0.961, and 0.972 at 3, 4, 5, and 6mo, respectively. The C-index values in the validation set were 0.860, 0.936, 0.951, and 0.965 at 3, 4, 5, and 6mo, respectively. Decision-curve analysis indicated that only the 4-, 5-, and 6-month nomograms had significant net benefits over a large threshold probabilities interval. CONCLUSION: Preoperative PVR, SOTT, PE, RTS, and hypertension are significant risk factors for postoperative PVR formation in patients with primary RRD. The proposed nomogram can effectively predict the 4-, 5-, and 6-month PVR-free probabilities after surgery and assist in making clinical decisions during follow-up.

4.
Acta Ophthalmol ; 100(4): e1024-e1030, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34403213

RESUMO

PURPOSE: To report the clinical outcomes and evaluate the efficacy of a novel bubble ultra-wide field viewing system for vitreoretinal surgery. DESIGN: Prospective, noncomparative, interventional case series. PARTICIPANTS: One hundred and fifty-one eyes of 146 consecutive patients with proliferative diabetic retinopathy (PDR), vitreous haemorrhage originating from retinal vein occlusion (VH-RVO), epiretinal membrane (EM), macular hole (MH) or retinal detachment (RD) who underwent vitreoretinal surgery using the bubble ultra-wide field viewing system were included. METHODS: A standard phacoemulsification was performed on each patient. Core humour and mid-peripheral vitreous humour were removed using a planoconcave lens. A suitably sized bubble was infused to attach to the posterior capsule or the anterior chamber depending on the integrity of the posterior capsule. The planoconcave lens and the air bubble formed the wide-angle viewing system, through which peripheral vitrectomy was performed. MAIN OUTCOME MEASURES: Range of applications, field of view, model validation and complications were recorded. RESULTS: The new ultra-wide field viewing system was successfully applied in all eyes, including 34 with PDR, 28 VH-RVO, 28 EM, 25 MH and 36 RD. Peripheral vitrectomy, local or panretinal laser photocoagulation, and removal of the peripheral proliferative membrane were successfully performed while viewing through this system. Maximum peripheral retinal area observable during the procedure was positively correlated with pupil diameter. Model analysis results showed that when the pupil diameter was 6 mm, the maximum field of view was approximately 128.1- 148.0 degrees with this system. Of 142 eyes, the main intraoperative complication was iatrogenic retinal breaks (IRBs) in 8 eyes (5.3%) and posterior capsule injury by vitreous cutter during bubble removal in 6 eyes (4.2%). The postsurgery mean best-corrected visual acuity (BCVA) (0.48 ± 0.39 logMAR) was significantly improved compared with the preoperative mean BCVA (1.60 ± 1.08 logMAR, p < 0.001). No incidents of postoperative choroidal detachment, secondary glaucoma or endophthalmitis were recorded. CONCLUSIONS: For patients with lens excision or absence, vitreoretinal surgery can be successfully performed using the novel viewing system described here. The system is a safe, convenient and economical ultra-wide field viewing system with a wide range of applications.


Assuntos
Retinopatia Diabética , Membrana Epirretiniana , Descolamento Retiniano , Cirurgia Vitreorretiniana , Retinopatia Diabética/complicações , Membrana Epirretiniana/complicações , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Humanos , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual , Vitrectomia/métodos , Cirurgia Vitreorretiniana/efeitos adversos
5.
Int Ophthalmol ; 41(12): 3903-3910, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34291401

RESUMO

PURPOSE: To compare safety and effectiveness among methods to remove sticky silicone oil bubbles adhered to the retinal surface. METHODS: This retrospective nonrandomised case series included 14 eyes of 14 patients who had sticky silicone oil residue during silicone oil removal surgery. For small sticky silicone oil bubbles (< 2-disc diameter), aspiration was performed with a 23-gauge vitreous cutter. Residual tiny oil bubbles were then removed with a silicone-tipped flute needle or internal limiting membrane (ILM) peeling. For large sticky silicone oil bubbles (≥ 2-disc diameter) that could not be removed with a 23-gauge vitreous cutter, we devised a more efficient active removal method involving a modified 22-gauge venous indwelling cannula device. RESULTS: The mean preoperative best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR]) significantly improved from 1.28 ± 0.63 logMAR to 0.77 ± 0.58 logMAR (p = 0.014). The postoperative BCVA and improvement in BCVA were significantly better in the ILM peeling group than in the non-ILM peeling group (p = 0.004 and p = 0.045, respectively). Postoperative complications included residual sticky silicone oil bubbles in seven eyes without ILM peeling (50.0%), retinal neuroepithelial layer damage in two eyes (14.3%), and temporary hypotony in five eyes (35.7%). CONCLUSION: Various methods can safely and efficiently remove sticky silicone oil bubbles adhered to the retinal surface. A 22-gauge venous indwelling cannula enabled simple and safe removal of large sticky silicone oil bubbles, while small residual sticky silicone oil bubbles could be completely removed by ILM peeling.


Assuntos
Descolamento Retiniano , Perfurações Retinianas , Membrana Basal , Tamponamento Interno , Humanos , Descolamento Retiniano/cirurgia , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Óleos de Silicone , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia
6.
Br J Ophthalmol ; 103(10): 1495-1502, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30470714

RESUMO

PURPOSE: The aim of this study was to determine the effect of the inverted internal limiting membrane (ILM) flap technique on the macular hole (MH) closure and foveal microstructure recovery of patients with highly myopic MH. METHODS: Pars plana vitrectomy and gas tamponade with the inverted ILM flap technique (19 eyes) or with the ILM peeling technique (21 eyes) were performed in patients with highly myopic MH with or without retinal detachment. The rate of MH closure and retinal reattachment, the reconstructive anatomical change of the foveal microstructure and the best-corrected visual acuities (BCVA) of the two groups were compared. RESULTS: The anatomic closure rate was statistically significantly higher in the inverted group (100%) than in the peeling group (66.7%; p=0.009). All eyes with MH retinal detachment had successful retinal reattachment in these two groups. However, the rate of the external limiting membrane (ELM) and ellipsoid zone (EZ) (p=0.020), as well as gliosis (p=0.049) in macular area, detected by OCT, was significantly greater in the inverted group than in the peeling group. The postoperative BCVA was significantly better in the eyes with ELM, EZ (p=0.031) and gliosis (p=0.008), but without hyperreflective foci (p=0.001). CONCLUSIONS: These findings demonstrate that the inverted ILM flap technique has better efficacy than the ILM peeling technique for patients with myopic MH in closure rate, foveal microstructure and postoperative BCVA.


Assuntos
Membrana Basal/cirurgia , Fóvea Central/fisiopatologia , Miopia Degenerativa/complicações , Perfurações Retinianas/cirurgia , Retalhos Cirúrgicos , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Corantes/administração & dosagem , Tamponamento Interno/métodos , Feminino , Fluorocarbonos/administração & dosagem , Humanos , Verde de Indocianina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Perfurações Retinianas/etiologia , Perfurações Retinianas/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Vitrectomia/métodos , Adulto Jovem
7.
Int J Ophthalmol ; 6(6): 892-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24392344

RESUMO

Transscleral suturing is a commonly applied technique to fix intraocular implants in the sulcus. A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result in an increased incidence of endophthalmitis. Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation. This is a simple, quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA