1.
Rapid Commun Mass Spectrom ; 32(24): 2141-2151, 2018 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-30198194

RESUMO

RATIONALE: Structural characterization of individual compounds in very complex mixtures is difficult to achieve. One important step in structural elucidation is understanding the mass spectrometric fragmentation mechanisms of the compounds present in such mixtures. Here, different individual compounds presumed to be present in a complex crude oil mixture have been synthesized and structurally characterized by tandem mass spectrometry (MS/MS) studies. METHODS: Model compounds with different aromatic cores and various substitutents were synthesized. Major effort has been put into producing isomerically pure compounds to better understand the fragmentation pattern. Each synthesized compound has been subjected to MSn studies using either a triple quadrupole or a linear ion trap mass spectrometer with electrospray or atmospheric pressure photoionization. The results are used to analyze individual compounds from a complex vacuum gas oil (VGO). RESULTS: The synthesized compounds and a chromatographically simplified vacuum gas oil were used for structural analysis. The major fragmentation mechanism is the benzylic cleavage of the aliphatic side chain. Each side chain can be separately removed from the aromatic core by using MSn methods. At the end of a series of fragmentations, the base aromatic core structure remains and can be chararcterized. CONCLUSIONS: By defining the fragmentation mechanism in complex oil samples it was possible to structurally characterize individual compounds present in a chromatographically simplified VGO. The compounds consist of an aromatic core with aliphatic side chains. Cleavage of all side chains can be achieved by MSn measurements, allowing characterization of the remaining core structure.

2.
Anal Chem ; 85(20): 9478-85, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24063573

RESUMO

The high complexity of crude oil makes the use of chromatographic separation an important tool especially for sample simplification. The coupling of normal-phase high-performance liquid chromatography (HPLC) using a polar aminocyano column to a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer offers the best attributes of good separation prior to ultrahigh resolution mass spectrometry (MS) detection. Atmospheric pressure laser ionization (APLI) was used as an ionization technique to analyze the nitrogen-containing aromatic compounds in a deasphalted crude oil due to its unique selectivity toward aromatic compounds and also due to its sensitivity. Two main chromatographic peaks were observed during this separation indicating a class-based separation. Mass spectra obtained from fractions were collected along the entire retention time and compared with each other to assign the unique constituents. By coupling the HPLC system directly to the FTICR mass spectrometer, comparable ion and UV chromatograms were obtained, reflecting the scan-to-scan sensitivity of the coupling system. The results show that it is possible to calculate reconstructed class chromatograms (RCC), allowing differences in class composition to be traced along the retention time. As an example, radical and protonated nitrogen species generated by APLI were detected along the retention time which enabled a differentiation between basic and nonbasic species in the same polar peak, thus overcoming the limitation of chromatographic resolution. This report represents the first online LC-FTICR MS coupling in the field of crude oil analysis.

3.
J Am Soc Mass Spectrom ; 23(5): 806-15, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22359090

RESUMO

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has been applied for the quantitative speciation of sulfur containing compounds in gas oil (GO). For this purpose, ionization and mass spectrometric parameters have been studied and optimized with a set of standard compounds and GO samples. Comprehensive two-dimensional gas chromatography (GCxGC) was used as the reference method. To allow a quantitative comparison between FT-ICR MS and GCxGC results for GO samples, FT-ICR MS parameters were optimized and data obtained by both techniques were standardized. Response factors were established for two ionization modes: atmospheric pressure photo ionization (APPI) and electrospray after selective derivatization of sulfur compounds (MeESI). To test the validity of the developed MS methods, a third GO was analyzed and response factors were applied. Comparison with GCxGC results showed good agreement for sulfur families (deviation within 5% and 15% for MeESI and APPI data, respectively). Abundances of individual isomer groups match within 40% in most cases. These results principally demonstrate the suitability of FT-ICR MS for a quantitative analysis of sulfur compounds (by DBE and carbon number distribution pattern) in petroleum middle distillates. This approach has the potential to be extended to higher- and non-boiling petroleum fractions where quantitative speciation is presently not available.

4.
Angew Chem Int Ed Engl ; 48(10): 1788-91, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19173274

RESUMO

Through different windows: One major obstacle in energy research is the complexity and variety of compounds present in crude oil. A study of different ionization methods for mass spectrometry shows that the mass spectrum very strongly depends on which method is used.

5.
Anal Bioanal Chem ; 392(5): 839-48, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18695977

RESUMO

The analysis of sulfur aromatics in vacuum gas oils (VGO) distilled from an Iranian light crude oil is discussed. The VGOs were fractionated into three boiling ranges, 390-460, 460-520, and 520-550 degrees C, and were analyzed using liquid chromatographic separation on a Pd(II)-bonded stationary phase followed by identification with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). It was possible to detect a large number of thiophenes, including a substantial number of isomers, in the three VGO fractions. Separation on the palladium phase and inclusion of sulfur-selective derivatization makes electrospray ionization of these nonpolar compounds possible. An elemental composition can be assigned to a large number of S(1) compounds without ambiguity in the presence of abundant hydrocarbons. With an increase in boiling temperature, an increase in the size of the aromatic system and the number of side chain carbon atoms was observed. In addition, the masses of higher magnitude shifted toward larger aromatic systems with an increase in boiling range. A comparison of FT-ICR MS and comprehensive gas chromatography is also given.

6.
Analyst ; 133(7): 867-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18575636

RESUMO

We report on the successful application of the recently introduced atmospheric pressure laser ionization (APLI) method as a novel tool for the analysis of crude oil and its components. Using Fourier transform ion cyclotron resonance mass spectrometry, unambiguous determination of key compounds in this complex matrix with unprecedented sensitivity is presented.

7.
Anal Bioanal Chem ; 389(5): 1329-39, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17885749

RESUMO

Crude oil analysis has long been an inspiration for the development of analytical techniques. Especially mass spectrometry has flourished as a result of the challenge these extremely complex problems offer. Here an overview of different analytical methods is presented that shows different ways to analyze volatile and nonvolatile crude oil components. Focus has been placed on the use of mass spectrometry and especially the new developments that have been introduced using the emerging technique of Fourier transform ion cyclotron resonance mass spectrometry. These studies are examples of how far the development of analytical methods has come for the task of studying such complex problems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA