Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Ophthalmol Retina ; 8(4): 360-366, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37913992

RESUMO

PURPOSE: To assess the anatomic and functional outcomes in eyes with neovascular age-related macular degeneration (nAMD) previously treated with anti-VEGF therapy in response to intravitreal faricimab. DESIGN: Retrospective, interventional, consecutive case series. SUBJECTS: Patients with previously treated nAMD who received ≥ 4 consecutive injections of faricimab were included. The study period was from March through November 2022. METHODS: Clinical and imaging data were extracted from the electronic medical record. Central foveal thickness (CFT), maximum fibrovascular pigment epithelial detachment (fvPED) height, and Snellen visual acuity (VA) were obtained. Generalized estimating equations were used to analyze the change in CFT, maximum fvPED height, and logarithm of the minimum angle of resolution VA. MAIN OUTCOME MEASURES: Change in CFT, maximum fvPED height, and Snellen VA before faricimab and after ≥ 4 faricimab intravitreal injections. RESULTS: During the study period, 218 eyes of 191 patients met inclusion criteria. Mean age was 79.9 (range, 70.6-89.2) years. The mean number of intravitreal anti-VEGF injections received before faricimab was 34.2 (range, 6.4-62). The following results were found after ≥ 4 faricimab injections. Mean logarithm of the minimum angle of resolution VA before switching to faricimab was 0.58 (Snellen VA ∼20/76; range, 20/22-20/264) and was 0.55 (Snellen VA ∼20/71; range, 20/21-20/235; P = 0.20) after switching. Mean maximum fvPED height was 195.0 (range, 50.2-339.8) µm before switching to faricimab and improved to 165.0 (range, 33.6-296.4; P < 0.001) µm after switching. Mean CFT was 354.8 (range, 184.7-524.9) µm before switching to faricimab and improved to 306.6 (range, 144.4-468.8; P < 0.001) after switching. The proportion of eyes with intraretinal fluid was 36.7% (80/218 eyes) before switching, and decreased to 24.8% (54/218 eyes, P < 0.001) after switching. The proportion of eyes with subretinal fluid was 53.2% (116/218 eyes) before switching and decreased to 26.6% (58/218 eyes, P < 0.001) after switching. CONCLUSIONS: Intravitreal faricimab may improve anatomic outcomes in patients with previously treated nAMD, while maintaining VA in the short-term. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Anticorpos Biespecíficos , Degeneração Macular , Descolamento Retiniano , Humanos , Idoso , Idoso de 80 Anos ou mais , Ranibizumab , Inibidores da Angiogênese , Fator A de Crescimento do Endotélio Vascular , Estudos Retrospectivos , Resultado do Tratamento , Tomografia de Coerência Óptica/métodos , Descolamento Retiniano/tratamento farmacológico , Degeneração Macular/tratamento farmacológico
3.
Ophthalmol Retina ; 7(10): 862-868, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37277096

RESUMO

OBJECTIVE: To evaluate the appropriateness and readability of the medical knowledge provided by ChatGPT-4, an artificial intelligence-powered conversational search engine, regarding common vitreoretinal surgeries for retinal detachments (RDs), macular holes (MHs), and epiretinal membranes (ERMs). DESIGN: Retrospective cross-sectional study. SUBJECTS: This study did not involve any human participants. METHODS: We created lists of common questions about the definition, prevalence, visual impact, diagnostic methods, surgical and nonsurgical treatment options, postoperative information, surgery-related complications, and visual prognosis of RD, MH, and ERM, and asked each question 3 times on the online ChatGPT-4 platform. The data for this cross-sectional study were recorded on April 25, 2023. Two independent retina specialists graded the appropriateness of the responses. Readability was assessed using Readable, an online readability tool. MAIN OUTCOME MEASURES: The "appropriateness" and "readability" of the answers generated by ChatGPT-4 bot. RESULTS: Responses were consistently appropriate in 84.6% (33/39), 92% (23/25), and 91.7% (22/24) of the questions related to RD, MH, and ERM, respectively. Answers were inappropriate at least once in 5.1% (2/39), 8% (2/25), and 8.3% (2/24) of the respective questions. The average Flesch Kincaid Grade Level and Flesch Reading Ease Score were 14.1 ± 2.6 and 32.3 ± 10.8 for RD, 14 ± 1.3 and 34.4 ± 7.7 for MH, and 14.8 ± 1.3 and 28.1 ± 7.5 for ERM. These scores indicate that the answers are difficult or very difficult to read for the average lay person and college graduation would be required to understand the material. CONCLUSIONS: Most of the answers provided by ChatGPT-4 were consistently appropriate. However, ChatGPT and other natural language models in their current form are not a source of factual information. Improving the credibility and readability of responses, especially in specialized fields, such as medicine, is a critical focus of research. Patients, physicians, and laypersons should be advised of the limitations of these tools for eye- and health-related counseling. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Letramento em Saúde , Doenças Retinianas , Humanos , Compreensão , Estudos Transversais , Inteligência Artificial , Estudos Retrospectivos , Doenças Retinianas/cirurgia
4.
J Vitreoretin Dis ; 6(4): 324-328, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37007920

RESUMO

Purpose: To describe delayed detection of pericentral hydroxychloroquine (HCQ) toxicity. Methods: 67-year-old Dominican woman with rheumatoid arthritis on HCQ presented for examination. Results: Spectral-domain optical coherence tomography (SD-OCT) demonstrated bilateral cystoid macular edema with parafoveal attenuation of the external limiting membrane (ELM) and the ellipsoid zone (EZ). ELM and EZ disruption was present in inferior macula. While subtle superior defects were present on 10-2 visual fields, superior pericentral defects were noted on 24-2 testing. Hyperautofluorescence along inferior arcades corresponded to SD-OCT and visual fields. Examination 2 years prior demonstrated nonspecific points of depression on 10-2 visual fields and normal central SD-OCT findings. EZ and ELM disruption was present in the perifoveal inferior macula. Conclusions: Early pericentral distribution of HCQ toxicity is not limited to Asian patients. Detecting pericentral HCQ toxicity involves reviewing entire macular cube on OCT. When OCT changes are suspected on parafoveal OCT B-scans, visual field testing with 24-2 may be more sensitive than 10-2.

5.
Orbit ; 38(2): 112-118, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29985741

RESUMO

PURPOSE: To better understand the nature of periocular dermatitis (PD) patient presentation, treatment, time-to-cure, and referral pattern for allergy testing in an ophthalmic academic center. METHODS: A retrospective chart review of 344 patients diagnosed with PD between January 1, 2000 and November 30, 2016 at the Edward S. Harkness Eye Institute was performed. Eighty patients were eligible for the study. The primary endpoint was the time-to-cure. Cox proportional hazards regression was performed to assess if there was a significant difference between time-to-cure in patients treated with: 1) combination topical steroid/antibiotic (n = 6) vs. topical steroid alone (n = 40) and 2) combination topical steroid and oral antihistamine (n = 5) vs. topical steroid alone (n = 40). RESULTS: The median age of eligible patients was 57.69 years old, 66.25% of patients were female, and 41.25% had a history of atopy. Seven patients in total were referred for allergy testing. A significant difference was found in likelihood of cure when comparing combination topical steroid and oral antihistamine versus topical steroid alone, adjusting for age and gender (aHR = 3.97, 95% CI: 1.40-11.25). No significance was found when comparing combination topical steroid/antibiotic versus topical steroid alone (aHR = 1.96, 95% CI: 0.72-5.27). CONCLUSION: Patients treated with topical steroid and oral antihistamine were approximately 4 times more likely to experience cure in comparison to patients treated with topical steroids alone. While the majority of patients were not referred for formal allergy testing, this would likely be of benefit.


Assuntos
Dermatite Alérgica de Contato/diagnóstico , Dermatite Atópica/diagnóstico , Dermatite Irritante/diagnóstico , Doenças Palpebrais/diagnóstico , Centros Médicos Acadêmicos , Administração Oftálmica , Administração Oral , Adulto , Idoso , Antialérgicos/uso terapêutico , Antibacterianos/uso terapêutico , Dermatite Alérgica de Contato/tratamento farmacológico , Dermatite Atópica/tratamento farmacológico , Dermatite Irritante/tratamento farmacológico , Quimioterapia Combinada , Doenças Palpebrais/tratamento farmacológico , Feminino , Fluormetolona/uso terapêutico , Glucocorticoides/uso terapêutico , Humanos , Hidrocortisona/uso terapêutico , Etabonato de Loteprednol/uso terapêutico , Masculino , Pessoa de Meia-Idade , New York , Soluções Oftálmicas , Oftalmologia , Modelos de Riscos Proporcionais , Encaminhamento e Consulta , Estudos Retrospectivos
6.
Ophthalmic Plast Reconstr Surg ; 34(6): e186-e189, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30289825

RESUMO

A 15-month-old male was referred for biopsy of presumed rhabdomyosarcoma in the setting of rapidly progressing left-sided proptosis. Examination revealed left periorbital edema and left hypoglobus. MRI revealed a soft-tissue density mass within the left lateral retrobulbar space. Several days later, he developed acute periorbital ecchymosis and increasing edema. With high suspicion for a vascular lesion, a CT scan was performed with dynamic arterial and venous imaging. Central filling was noted in the lateral retrobulbar component with increased enhancement on delayed venous imaging in the middle cranial fossa component favoring the diagnosis of a low-flow orbital venous malformation. In the setting of spontaneous orbital hemorrhage and risk of future vision loss, the decision was made to proceed with a combined neurosurgical approach treating the intracranial component and debulking the orbital component. This case highlights the importance of thorough radiographic evaluation prior to proceeding with a surgical procedure in the appropriate clinical context.


Assuntos
Órbita/irrigação sanguínea , Neoplasias Orbitárias/diagnóstico , Rabdomiossarcoma/diagnóstico , Malformações Vasculares/diagnóstico , Veias/anormalidades , Biópsia , Diagnóstico Diferencial , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Procedimentos Cirúrgicos Oftalmológicos/métodos , Órbita/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Malformações Vasculares/cirurgia , Veias/diagnóstico por imagem
7.
Ophthalmic Plast Reconstr Surg ; 34(6): 560-561, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29547470

RESUMO

PURPOSE: This study evaluates the reliability of a frequently used subjective measurement of orbital compliance (0-3 scale) and describes a simple, quantitative measure with excellent intra- and interrater reliability. METHODS: Two examiners performed both measurements on 100 orbits (50 consecutive patients) from the office of 1 oculoplastics surgeon. Each measurement was obtained at 2 different time points, 10 minutes apart. For the subjective measurement, the patient was asked to close their eyes, and the globe was displaced posteriorly with digital pressure until moderate resistance was felt. This was graded on a 0 to 3 scale. For the quantitative measurement (millimeter scale), the difference in axial displacement was measured using a Hertel exophthalmometer. RESULTS: The subjective measurement (scale, 0-3) showed excellent test-retest reliability (average, 0.901) for both examiners at both time points and good interobserver reliability (average, 0.677). The quantitative measurement (millimeter scale) showed excellent test-retest reliability (average, 0.848) and very good interobserver reliability (average, 0.756). CONCLUSION: This study shows that while both methods have both excellent test-retest reliability, the interobserver reliability is slightly higher with the quantitative measurement. This suggests that the described measurement of orbital compliance is both a reasonable alternative and possibly more accurate measurement without the steep learning curve.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Exoftalmia/diagnóstico , Neoplasias Orbitárias/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Exoftalmia/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Orbitárias/fisiopatologia , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA