Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Magn Reson Med ; 2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39072791

RESUMO

PURPOSE: There are many approaches to the quantitative BOLD (qBOLD) technique described in the literature, differing in pulse sequences, MRI parameters and data processing. Thus, in this review, we summarized the acquisition methods, approaches used for oxygenation quantification and clinical populations investigated. METHODS: Three databases were systematically searched (Medline, Embase, and Web of Science) for published research that used qBOLD methods for quantification of oxygen metabolism. Data extraction and synthesis were performed by one author and reviewed by a second author. RESULTS: A total of 93 relevant papers were identified. Acquisition strategies were summarized, and oxygenation parameters were found to have been investigated in many pathologies such as steno-occlusive diseases, stroke, glioma, and multiple sclerosis disease. CONCLUSION: A summary of qBOLD approaches for oxygenation measurements and applications could help researchers to identify good practice and provide objective information to inform the development of future consensus recommendations.

2.
Cancer Med ; 13(14): e70049, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39056567

RESUMO

BACKGROUND/OBJECTIVES: Ataxia telangiectasia (A-T) is an inherited multisystem disorder with increased sensitivity to ionising radiation and elevated cancer risk. Although other cancer predisposition syndromes have established cancer screening protocols, evidence-based guidelines for cancer screening in A-T are lacking. This study sought to assess feasibility of a cancer screening protocol based on whole-body MRI (WB-MRI) in children and young people with A-T. DESIGN/METHODS: Children and young people with A-T were invited to undergo a one-off non-sedated 3-Tesla WB-MRI. Completion rate of WB-MRI was recorded and diagnostic image quality assessed by two experienced radiologists, with pre-specified success thresholds for scan completion of >50% participants and image quality between acceptable to excellent in 65% participants. Positive imaging findings were classified according to the ONCO-RADS system. Post-participation interviews were performed with recruited families to assess the experience of participating and feelings about waiting for, and communication of, the findings of the scan. RESULTS: Forty-six children and young people with A-T were identified, of which 36 were eligible to participate, 18 were recruited and 16 underwent WB-MRI. Nineteen parents participated in interviews. Fifteen participants (83%) completed the full WB-MRI scan protocol. The pre-specified image quality criterion was achieved with diagnostic images obtained in at least 93% of each MRI sequence. Non-malignant scan findings were present in 4 (25%) participants. Six themes were identified from the interviews: (1) anxiety is a familiar feeling, (2) the process of MRI scanning is challenging for some children and families, (3) preparation is essential to reduce stress, (4) WB-MRI provides the reassurance about the physical health that families need, (5) WB-MRI experience turned out to be a positive experience and (6) WB-MRI allows families to be proactive. CONCLUSION: This study shows that WB-MRI for cancer screening is feasible and well-accepted by children and young people with A-T and their families.


Assuntos
Ataxia Telangiectasia , Detecção Precoce de Câncer , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Imagem Corporal Total , Humanos , Ataxia Telangiectasia/diagnóstico por imagem , Criança , Feminino , Masculino , Adolescente , Imageamento por Ressonância Magnética/métodos , Estudos Transversais , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/psicologia , Imagem Corporal Total/métodos , Adulto Jovem , Pré-Escolar , Neoplasias/diagnóstico por imagem , Neoplasias/psicologia , Adulto
3.
Molecules ; 29(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38731585

RESUMO

The techniques used to detect and quantify cyanocobalamin (vitamin B12) vary considerably in terms of detection sensitivity, from the most sensitive, based on radioisotopes and mass spectrometry (MS) with limits of detection (LOD) in fg mL-1, to fluorescence (FL) and surface plasmon resonance (SPR) biosensors with LOD values in the range of a few µg mL-1. For accurate quantification of an analyte present at trace levels in complex biological matrices, a selective separation and enrichment step is required to overcome matrix interferences and ensure sufficient detection sensitivity. In this study, iron oxide magnetic nanoparticles (IONPs) were used for the extraction and initial preconcentration of cyanocobalamin (vitamin B12). In the dependence of the magnetization on the H-field (hysteresis loop), no coercivity and remanence values were found at 300 K, indicating the superparamagnetic properties of the tested IONPs. Perfluorinated acids were used as amphiphilic agents to allow the sorption of cyanocobalamin onto the IONPs. FT-IR/ATR spectroscopy was used to confirm the sorption of cyanocobalamin on the IONPs. The influence of the addition of a homologous series of perfluorinated acids such as trifluoroacetic acid (TFAA), heptafluorobutyric acid (HFBA), and trichloroacetic acid (TCAA) to the extraction mixture was tested considering their type, mass, and time required for effective sorption. The adsorption kinetics and isotherm, described by the Freundlich and Langmuir equations, were analyzed. The maximum adsorption capacity (qm) exceeded 6 mg g-1 and was 8.9 mg g-1 and 7.7 mg g-1 for HFBA and TCAA, respectively, as the most efficient additives. After the desorption process using aqueous KH2PO4 solution, the sample was finally analyzed spectrophotometrically and chromatographically. The IONP-based method was successfully applied for the isolation of cyanocobalamin from human urine samples. The results showed that the developed approach is simple, cheap, accurate, and efficient for the determination of traces of cyanocobalamin in biological matrices.


Assuntos
Nanopartículas Magnéticas de Óxido de Ferro , Vitamina B 12 , Vitamina B 12/química , Vitamina B 12/análise , Adsorção , Nanopartículas Magnéticas de Óxido de Ferro/química , Limite de Detecção , Porosidade , Espectroscopia de Infravermelho com Transformada de Fourier
4.
Eur Radiol Exp ; 8(1): 27, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38443722

RESUMO

BACKGROUND: Tumour hypoxia is a recognised cause of radiotherapy treatment resistance in head and neck squamous cell carcinoma (HNSCC). Current positron emission tomography-based hypoxia imaging techniques are not routinely available in many centres. We investigated if an alternative technique called oxygen-enhanced magnetic resonance imaging (OE-MRI) could be performed in HNSCC. METHODS: A volumetric OE-MRI protocol for dynamic T1 relaxation time mapping was implemented on 1.5-T clinical scanners. Participants were scanned breathing room air and during high-flow oxygen administration. Oxygen-induced changes in T1 times (ΔT1) and R2* rates (ΔR2*) were measured in malignant tissue and healthy organs. Unequal variance t-test was used. Patients were surveyed on their experience of the OE-MRI protocol. RESULTS: Fifteen patients with HNSCC (median age 59 years, range 38 to 76) and 10 non-HNSCC subjects (median age 46.5 years, range 32 to 62) were scanned; the OE-MRI acquisition took less than 10 min and was well tolerated. Fifteen histologically confirmed primary tumours and 41 malignant nodal masses were identified. Median (range) of ΔT1 times and hypoxic fraction estimates for primary tumours were -3.5% (-7.0 to -0.3%) and 30.7% (6.5 to 78.6%) respectively. Radiotherapy-responsive and radiotherapy-resistant primary tumours had mean estimated hypoxic fractions of 36.8% (95% confidence interval [CI] 17.4 to 56.2%) and 59.0% (95% CI 44.6 to 73.3%), respectively (p = 0.111). CONCLUSIONS: We present a well-tolerated implementation of dynamic, volumetric OE-MRI of the head and neck region allowing discernment of differing oxygen responses within biopsy-confirmed HNSCC. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04724096 . Registered on 26 January 2021. RELEVANCE STATEMENT: MRI of tumour hypoxia in head and neck cancer using routine clinical equipment is feasible and well tolerated and allows estimates of tumour hypoxic fractions in less than ten minutes. KEY POINTS: • Oxygen-enhanced MRI (OE-MRI) can estimate tumour hypoxic fractions in ten-minute scanning. • OE-MRI may be incorporable into routine clinical tumour imaging. • OE-MRI has the potential to predict outcomes after radiotherapy treatment.


Assuntos
Neoplasias de Cabeça e Pescoço , Oxigênio , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imageamento por Ressonância Magnética , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Hipóxia Tumoral
5.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542125

RESUMO

In recent years, there has been a growing interest in plant pigments as readily available nutraceuticals. Photosynthetic pigments, specifically chlorophylls and carotenoids, renowned for their non-toxic antioxidant properties, are increasingly finding applications beyond their health-promoting attributes. Consequently, there is an ongoing need for cost-effective methods of isolation. This study employs a co-precipitation method to synthesize magnetic iron oxide nanoparticles. Scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS) confirms that an aqueous environment and oxidizing conditions yield nanosized iron oxide with particle sizes ranging from 80 to 140 nm. X-ray photoelectron spectroscopy (XPS) spectra indicate the presence of hydrous iron oxide FeO(OH) on the surface of the nanosized iron oxide. The Brunauer-Emmett-Teller (BET) surface area of obtained nanomaterial was 151.4 m2 g-1, with total pore volumes of pores 0.25 cm3 g-1 STP. The material, designated as iron oxide nanoparticles (IONPs), serves as an adsorbent for magnetic solid phase extraction (MSPE) and isolation of photosynthetic pigments (chlorophyll a, lutein) from extracts of higher green plants (Mentha piperita L., Urtica dioica L.). Sorption of chlorophyll a onto the nanoparticles is confirmed using UV-vis spectroscopy, Fourier transform infrared photoacoustic spectroscopy (FT-IR/PAS), and high-performance liquid chromatography (HPLC). Selective sorption of chlorophyll a requires a minimum of 3 g of IONPs per 12 mg of chlorophyll a, with acetone as the solvent, and is dependent on a storage time of 48 h. Extended contact time of IONPs with the acetone extract, i.e., 72 h, ensures the elimination of remaining components except lutein, with a spectral purity of 98%, recovered with over 90% efficiency. The mechanism of chlorophyll removal using IONPs relies on the interaction of the pigment's carbonyl (C=O) groups with the adsorbent surface hydroxyl (-OH) groups. Based on molecular dynamics (MD) simulations, it has been proven that the selective adsorption of pigments is also influenced by more favorable dispersion interactions between acetone and chlorophyll in comparison with other solutes. An aqueous environment significantly promotes the removal of pigments; however, it results in a complete loss of selectivity.


Assuntos
Compostos Férricos , Luteína , Extratos Vegetais , Extratos Vegetais/química , Clorofila A , Clorofila , Espectroscopia de Infravermelho com Transformada de Fourier , Acetona , Água , Adsorção , Extração em Fase Sólida/métodos , Nanopartículas Magnéticas de Óxido de Ferro , Fenômenos Magnéticos
6.
Antibiotics (Basel) ; 13(2)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38391497

RESUMO

Iron oxide nanoparticles (IONPs) have many practical applications, ranging from environmental protection to biomedicine. IONPs are being investigated due to their high potential for antimicrobial activity and lack of toxicity to humans. However, the biological activity of IONPs is not uniform and depends on the synthesis conditions, which affect the shape, size and surface modification. The aim of this work is to synthesise IONPs using a mixed method, i.e., chemical co-precipitation combined with biogenic surface modification, using extracts from spent hops (Humulus lupulus L.) obtained as waste product from supercritical carbon dioxide hop extraction. Different extracts (water, dimethyl sulfoxide (DMSO), 80% ethanol, acetone, water) were further evaluated for antioxidant activity based on the silver nanoparticle antioxidant capacity (SNPAC), total phenolic content (TPC) and total flavonoid content (TFC). The IONPs were characterised via UV-vis spectroscopy, scanning electron microscopy (SEM), energy-dispersive spectrometry (EDS) and Fourier-transform infrared (FT-IR) spectroscopy. Spent hop extracts showed a high number of flavonoid compounds. The efficiency of the solvents used for the extraction can be classified as follows: DMSO > 80% ethanol > acetone > water. FT-IR/ATR spectra revealed the involvement of flavonoids such as xanthohumol and/or isoxanthohumol, bitter acids (i.e., humulones, lupulones) and proteins in the surface modification of the IONPs. SEM images showed a granular, spherical structure of the IONPs with diameters ranging from 81.16 to 142.5 nm. Surface modification with extracts generally weakened the activity of the IONPs against the tested Gram-positive and Gram-negative bacteria and yeasts by half. Only the modification of IONPs with DMSO extract improved their antibacterial properties against Gram-positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus, Micrococcus luteus, Enterococcus faecalis, Bacillus cereus) from a MIC value of 2.5-10 mg/mL to 0.313-1.25 mg/mL.

7.
Molecules ; 28(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37513392

RESUMO

Phytogenically synthesised nanoparticle (NP)-based drug delivery systems have promising potential in the field of biopharmaceuticals. From the point of view of biomedical applications, such systems offer the small size, high surface area, and possible synergistic effects of NPs with embedded biomolecules. This article describes the synthesis of silver nanoparticles (Ag-NPs) using extracts from the flowers and leaves of tansy (Tanacetum vulgare L.), which is known as a remedy for many health problems, including cancer. The reducing power of the extracts was confirmed by total phenolic and flavonoid content and antioxidant tests. The Ag-NPs were characterised by various analytical techniques including UV-vis spectroscopy, scanning electron microscopy (SEM), energy-dispersive spectrometry (EDS), Fourier transform infrared (FT-IR) spectroscopy, and a dynamic light scattering (DLS) system. The obtained Ag-NPs showed higher cytotoxic activity than the initial extracts against both human cervical cancer cell lines HeLa (ATCC CCL-2) and human melanoma cell lines A375 and SK-MEL-3 by MTT assay. However, the high toxicity to Vero cell culture (ATCC CCL-81) and human fibroblast cell line WS-1 rules out the possibility of their use as anticancer agents. The plant-mediated Ag-NPs were mostly bactericidal against tested strains with MBC/MIC index ≤4. Antifungal bioactivity (C. albicans, C. glabrata, and C. parapsilosis) was not observed for aqueous extracts (MIC > 8000 mg L-1), but Ag-NPs synthesised using both the flowers and leaves of tansy were very potent against Candida spp., with MIC 15.6 and 7.8 µg mL-1, respectively.


Assuntos
Anti-Infecciosos , Antineoplásicos , Nanopartículas Metálicas , Humanos , Prata/farmacologia , Prata/química , Espectroscopia de Infravermelho com Transformada de Fourier , Nanopartículas Metálicas/química , Extratos Vegetais/farmacologia , Extratos Vegetais/química , Anti-Infecciosos/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antineoplásicos/farmacologia , Testes de Sensibilidade Microbiana
8.
Cancer Med ; 12(13): 14663-14673, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37264737

RESUMO

BACKGROUND/OBJECTIVES: Ataxia telangiectasia (A-T) is a multiorgan disorder with increased vulnerability to cancer. Despite this increased cancer risk, there are no widely accepted guidelines for cancer surveillance in people affected by A-T. We aimed to understand the current international practice regarding cancer surveillance in A-T and agreed-upon approaches to develop cancer surveillance in A-T. DESIGN/METHODS: We used a consensus development method, the e-Delphi technique, comprising three rounds. Round 1 consisted of a Delphi questionnaire and a survey that collected the details of respondents' professional background, experience, and current practice of cancer surveillance in A-T. Rounds 2 and 3 were designed based on previous rounds and modified according to the comments made by the panellists. The pre-specified consensus threshold was ≥75% agreement. RESULTS: Thirty-five expert panellists from 13 countries completed the study. The survey indicated that the current practice of cancer surveillance varies widely between experts and centres'. Consensus was reached that evidence-based guidelines are needed for cancer surveillance in people with A-T, with separate recommendations for adults and children. Statements relating to the tests that should be included, the age for starting and stopping cancer surveillance and the optimal surveillance interval were also agreed upon, although in some areas, the consensus was that further research is needed. CONCLUSION: The international expert consensus statement confirms the need for evidence-based cancer surveillance guidelines in A-T, highlights key features that the guidelines should include, and identifies areas of uncertainty in the expert community. This elucidates current knowledge gaps and will inform the design of future clinical trials.


Assuntos
Ataxia Telangiectasia , Neoplasias , Adulto , Criança , Humanos , Ataxia Telangiectasia/complicações , Ataxia Telangiectasia/diagnóstico , Consenso , Técnica Delphi , Inquéritos e Questionários
9.
Health Expect ; 26(3): 1358-1367, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36929011

RESUMO

BACKGROUND/OBJECTIVES: Ataxia-telangiectasia (A-T) is a complex inherited disease associated with an increased risk of malignancy. Surveillance guidelines have demonstrated significant health benefits in other cancer predisposition syndromes. However, evidence-based guidelines for cancer screening are not currently used in the United Kingdom for people affected by A-T. This study aims to understand how people with A-T and their parents feel about cancer surveillance using whole-body magnetic resonance imaging (MRI) to inform the future development of cancer surveillance guidelines. DESIGN/METHODS: We conducted semistructured interviews with people affected by A-T. Data were analysed inductively using thematic analysis. RESULTS: Nine parents of children with A-T and four adults with A-T were interviewed. Five main themes emerged from the data, including (1) cancer screening was considered invaluable with the perceived value of early detection highlighted; (2) the cancer fear can increase anxiety; (3) the perceived limitations around current practice, with the responsibility for monitoring falling too strongly on parents and patients; (4) the need for effective preparation for cancer screening, including clear communication and (5) the challenges associated with MRI screening, where specific recommendations were made for improving the child's experience. CONCLUSION: This study suggests that stakeholders are positive about the perceived advantages of a cancer screening programme. Ongoing support and preparation techniques should be adopted to maximise adherence and minimise adverse psychosocial outcomes. PATIENT OR PUBLIC CONTRIBUTION: People with A-T and parents of people with A-T were actively involved in this study by giving their consent to be interviewed. An independent parent representative contributed to the study, supporting the research team in interpreting and commenting on the appropriateness of the language used in this report.


Assuntos
Ataxia Telangiectasia , Neoplasias , Criança , Adulto , Humanos , Imageamento por Ressonância Magnética , Imagem Corporal Total , Pais/psicologia , Neoplasias/diagnóstico por imagem
10.
Br J Radiol ; 96(1146): 20220624, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36809186

RESUMO

OBJECTIVE: Oxygen-enhanced MRI (OE-MRI) or tissue oxygen-level dependent (TOLD) MRI is an imaging technique under investigation for its ability to quantify and map oxygen distributions within tumours. The aim of this study was to identify and characterise the research into OE-MRI for characterising hypoxia in solid tumours. METHODS: A scoping review of published literature was performed on the PubMed and Web of Science databases for articles published before 27 May 2022. Studies imaging solid tumours using proton-MRI to measure oxygen-induced T1/R1 relaxation time/rate changes were included. Grey literature was searched from conference abstracts and active clinical trials. RESULTS: 49 unique records met the inclusion criteria consisting of 34 journal articles and 15 conference abstracts. The majority of articles were pre-clinical studies (31 articles) with 15 human only studies. Pre-clinical studies in a range of tumour types demonstrated consistent correlation of OE-MRI with alternative hypoxia measurements. No clear consensus on optimal acquisition technique or analysis methodology was found. No prospective, adequately powered, multicentre clinical studies relating OE-MRI hypoxia markers to patient outcomes were identified. CONCLUSION: There is good pre-clinical evidence of the utility of OE-MRI in tumour hypoxia assessment; however, there are significant gaps in clinical research that need to be addressed to develop OE-MRI into a clinically applicable tumour hypoxia imaging technique. ADVANCES IN KNOWLEDGE: The evidence base of OE-MRI in tumour hypoxia assessment is presented along with a summary of the research gaps to be addressed to transform OE-MRI derived parameters into tumour hypoxia biomarkers.


Assuntos
Neoplasias , Hipóxia Tumoral , Humanos , Biomarcadores Tumorais , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Oxigênio
11.
Sci Rep ; 12(1): 5974, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35396569

RESUMO

Metal artefacts degrade clinical image quality which decreases the confidence of using computed tomography (CT) for the delineation of key structures for treatment planning and leads to dose errors in affected areas. In this work, we investigated accuracy of doses computed by the Eclipse treatment planning system near and inside metallic elements for two different computation algorithms. An impact of CT metal artefact reduction methods on the resulting calculated doses has also been assessed. A water phantom including Gafchromic film and metal inserts was irradiated (max dose 5 Gy) using a 6 MV photon beam. Three materials were tested: titanium, alloy 600, and tungsten. The phantom CT images were obtained with the pseudo-monoenergetic reconstruction (PMR) and the iterative metal artefact reduction (iMAR). Image sets were used for dose calculation using an Eclipse treatment planning station (TPS). Monte Carlo (MC) simulations were used to predict the true dose distribution in the phantom allowing for comparison with doses measured by film and calculated by TPS. Measured and simulated percentage depth doses (PDDs) were not statistically different (p > 0.618). Regional differences were observed at edges of metallic objects (max 8% difference). However, PDDs simulated with and without film were statistically different (p < 0.002). PDDs calculated by the Acuros XB algorithm based on the dose-to-medium approach best matched the MC reference regardless of the CT reconstruction methods and inserts used (p > 0.078). PDDs obtained using other algorithms significantly differ from the MC values (p < 0.011). The Acuros XB algorithm with a dose-to-medium approach provides reliable dose calculation in all metal regions when using the Varian system. The inability of the AAA algorithm to model backscatter dose significantly limits its clinical application in the presence of metal. No significant impact on the dose calculation was found for a range of metal artefact reduction strategies.


Assuntos
Artefatos , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Metais , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
12.
Materials (Basel) ; 13(22)2020 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-33233399

RESUMO

Zeolites are materials with known sorption properties. The sorption is thought to progress mainly by ion exchange with Na+, K+, Mg2+, Ca2+ or H+ from the zeolite exchange sites. The aim of the study was to compare the sorption properties of natural and synthetic zeolites on the example of the removal of selected metals from aqueous acidic solutions. Uptake experiments for selected ions of chromium, manganese, selenium, nickel, cobalt, and iron were performed using the batch and kinetic column methods. The sorption of the individual metal ions in mg per 1g of sorbent was determined for each sorbent. The relative affinity sequence of the examined cations toward the various sorbent was presented. The Langmuir model was used to model the adsorption equilibrium. Vermiculite under 1 mm of diameter (SF), Na-X, and Na-A were proved to be the most suitable for the individual uptake of studied metal ions. It was observed that the behavior of selenium ions differed from the remaining ones which was interpreted that selenium undergoes adsorption in the anionic form. The fixed-bed column studies were performed using Na-A, ensuring the sorption of selenium in the presence of iron(III) ions. The experiments were conducted using Na-X zeolite pre-loaded by Fe(III) as well as unmodified sorbent eluted by an equimolar mixture containing 100 ppm of Fe and Se. Obtained results prove that selenium sorption improves if other metal ions such as iron appear in the acidic solution. That efficient selenium sorption conditions can be applied to remove selenium which was recognized as toxic at higher levels.

13.
Phys Med ; 77: 92-99, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32818774

RESUMO

PURPOSE: To evaluate the use of pseudo-monoenergetic reconstructions (PMR) from dual-energy computed tomography, combined with the iterative metal artefact reduction (iMAR) method. METHODS: Pseudo-monoenergetic CT images were obtained using the dual-energy mode on the Siemens Somatom Definition AS scanner. A range of PMR combinations (70-130 keV) were used with and without iMAR. A Virtual Water™ phantom was used for quantitative assessment of error in the presence of high density materials: titanium, alloys 330 and 600. The absolute values of CT number differences (AD) and normalised standard deviations (NSD) were calculated for different phantom positions. Image quality was assessed using an anthropomorphic pelvic phantom with an embedded hip prosthesis. Image quality was scored blindly by five observers. RESULTS: AD and NSD values revealed differences in CT number errors between tested sets. AD and NSD were reduced in the vicinity of metal for images with iMAR (p < 0.001 for AD/NSD). For ROIs away from metal, with and without iMAR, 70 keV PMR and pCT AD values were lower than for the other reconstructions (p = 0.039). Similarly, iMAR NSD values measured away from metal were lower for 130 keV and 70 keV PMR (p = 0.002). Image quality scores were higher for 70 keV and 130 keV PMR with iMAR (p = 0.034). CONCLUSION: The use of 70 keV PMR with iMAR allows for significant metal artefact reduction and low CT number errors observed in the vicinity of dense materials. It is therefore an attractive alternative to high keV imaging when imaging patients with metallic implants, especially in the context of radiotherapy planning.


Assuntos
Algoritmos , Artefatos , Humanos , Metais , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
14.
Eur J Nucl Med Mol Imaging ; 45(5): 759-767, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29164301

RESUMO

OBJECTIVE: To assess the optimal timing and predictive value of early intra-treatment changes in multimodality functional and molecular imaging (FMI) parameters as biomarkers for clinical remission in patients receiving chemoradiation for head and neck squamous cell carcinoma (HNSCC). METHODS: Thirty-five patients with stage III-IVb (AJCC 7th edition) HNSCC prospectively underwent 18F-FDG-PET/CT, and diffusion-weighted (DW), dynamic contrast-enhanced (DCE) and susceptibility-weighted MRI at baseline, week 1 and week 2 of chemoradiation. Patients with evidence of persistent or recurrent disease during follow-up were classed as non-responders. Changes in FMI parameters at week 1 and week 2 were compared between responders and non-responders with the Mann-Whitney U test. The significance threshold was set at a p value of <0.05. RESULTS: There were 27 responders and 8 non-responders. Responders showed a greater reduction in PET-derived tumor total lesion glycolysis (TLG40%; p = 0.007) and maximum standardized uptake value (SUVmax; p = 0.034) after week 1 than non-responders but these differences were absent by week 2. In contrast, it was not until week 2 that MRI-derived parameters were able to discriminate between the two groups: larger fractional increases in primary tumor apparent diffusion coefficient (ADC; p < 0.001), volume transfer constant (Ktrans; p = 0.012) and interstitial space volume fraction (Ve; p = 0.047) were observed in responders versus non-responders. ADC was the most powerful predictor (∆ >17%, AUC 0.937). CONCLUSION: Early intra-treatment changes in FDG-PET, DW and DCE MRI-derived parameters are predictive of ultimate response to chemoradiation in HNSCC. However, the optimal timing for assessment with FDG-PET parameters (week 1) differed from MRI parameters (week 2). This highlighted the importance of scanning time points for the design of FMI risk-stratified interventional studies.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Quimiorradioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Carcinoma de Células Escamosas/terapia , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
15.
Int J Radiat Oncol Biol Phys ; 100(2): 306-316, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29229323

RESUMO

PURPOSE: To determine the 3-dimensional (3D) intrafractional motion of head and neck squamous cell carcinoma (HNSCC). METHODS AND MATERIALS: Dynamic contrast-enhanced magnetic resonance images from 56 patients with HNSCC in the treatment position were analyzed. Dynamic contrast-enhanced magnetic resonance imaging consisted of 3D images acquired every 2.9 seconds for 4 minutes 50 seconds. Intrafractional tumor motion was studied in the 3 minutes 43 seconds of images obtained after initial contrast enhancement. To assess tumor motion, rigid registration (translations only) was performed using a region of interest (ROI) mask around the tumor. The results were compared with bulk body motion from registration to all voxels. Motion was split into systematic motion and random motion. Correlations between the tumor site and random motion were tested. The within-subject coefficient of variation was determined from 8 patients with repeated baseline measures. Random motion was also assessed at the end of the first week (38 patients) and second week (25 patients) of radiation therapy to investigate trends of motion. RESULTS: Tumors showed irregular occasional rapid motion (eg, swallowing or coughing), periodic intermediate motion (respiration), and slower systematic drifts throughout treatment. For 95% of the patients, displacements due to systematic and random motion were <1.4 mm and <2.1 mm, respectively, 95% of the time. The motion without an ROI mask was significantly (P<.0001, Wilcoxon signed rank test) less than the motion with an ROI mask, indicating that tumors can move independently from the bony anatomy. Tumor motion was significantly (P=.005, Mann-Whitney U test) larger in the hypopharynx and larynx than in the oropharynx. The within-subject coefficient of variation for random motion was 0.33. The average random tumor motion did not increase notably during the first 2 weeks of treatment. CONCLUSIONS: The 3D intrafractional tumor motion of HNSCC is small, with systematic motion <1.4 mm and random motion <2.1 mm 95% of the time.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Meios de Contraste , Humanos , Aumento da Imagem , Movimento (Física) , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem
16.
Br J Cancer ; 117(6): 791-800, 2017 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-28787429

RESUMO

BACKGROUND: The use of clinical MRI scanners to conduct pre-clinical research facilitates comparisons with clinical studies. Here the utility and sensitivity of anatomical and functional MRI data/biomarkers acquired from transgenic mouse models of neuroblastoma using a dedicated radiofrequency (RF) coil on a clinical 3T scanner was evaluated. METHODS: Multiparametric MRI of transgenic mice bearing abdominal neuroblastomas was performed at 3T, and data cross-referenced to that acquired from the same mice on a pre-clinical 7T MRI system. T2-weighted imaging, quantitation of the native longitudinal relaxation time (T1) and the transverse relaxation rate (R2*), and dynamic contrast-enhanced (DCE)-MRI, was used to assess tumour volume, phenotype and response to cyclophosphamide or cabozantinib. RESULTS: Excellent T2-weighted image contrast enabled clear tumour delineation at 3T. Significant correlations of tumour volume (R=0.98, P<0.0001) and R2* (R=0.87, P<0.002) measured at 3 and 7T were established. Mice with neuroblastomas harbouring the anaplastic lymphoma kinase mutation exhibited a significantly slower R2* (P<0.001), consistent with impaired tumour perfusion. DCE-MRI was performed simultaneously on three transgenic mice, yielding estimates of Ktrans for each tumour (median Ktrans values of 0.202, 0.168 and 0.114 min-1). Cyclophosphamide elicited a significant reduction in both tumour burden (P<0.002) and native T1 (P<0.01), whereas cabozantinib induced significant (P<0.01) tumour growth delay. CONCLUSIONS: Simultaneous multiparametric MRI of multiple tumour-bearing animals using this coil arrangement at 3T can provide high efficiency/throughput for both phenotypic characterisation and evaluation of novel therapeutics, and facilitate the introduction of functional MRI biomarkers into aligned imaging-embedded clinical trials.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imãs , Neuroblastoma/diagnóstico por imagem , Neoplasias Gástricas/diagnóstico por imagem , Quinase do Linfoma Anaplásico , Anilidas/uso terapêutico , Animais , Antineoplásicos/uso terapêutico , Meios de Contraste , Ciclofosfamida/uso terapêutico , Modelos Animais de Doenças , Feminino , Imageamento por Ressonância Magnética/instrumentação , Masculino , Camundongos , Camundongos Transgênicos , Mutação , Proteína Proto-Oncogênica N-Myc/metabolismo , Neuroblastoma/tratamento farmacológico , Neuroblastoma/genética , Neuroblastoma/patologia , Imagens de Fantasmas , Fenótipo , Piridinas/uso terapêutico , Receptores Proteína Tirosina Quinases/genética , Razão Sinal-Ruído , Neoplasias Gástricas/tratamento farmacológico , Neoplasias Gástricas/genética , Neoplasias Gástricas/patologia , Carga Tumoral/efeitos dos fármacos
17.
Br J Radiol ; 90(1071): 20160768, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28256151

RESUMO

Head and neck cancer (HNC) is a challenging tumour site for radiotherapy delivery owing to its complex anatomy and proximity to organs at risk (OARs) such as the spinal cord and optic apparatus. Despite significant advances in radiotherapy planning techniques, radiation-induced morbidities remain substantial. Further improvement would require high-quality imaging and tailored radiotherapy based on intratreatment response. For these reasons, the use of MRI in radiotherapy planning for HNC is rapidly gaining popularity. MRI provides superior soft-tissue contrast in comparison with CT, allowing better definition of the tumour and OARs. The lack of additional radiation exposure is another attractive feature for intratreatment monitoring. In addition, advanced MRI techniques such as diffusion-weighted, dynamic contrast-enhanced and intrinsic susceptibility-weighted MRI techniques are capable of characterizing tumour biology further by providing quantitative functional parameters such as tissue cellularity, vascular permeability/perfusion and hypoxia. These functional parameters are known to have radiobiological relevance, which potentially could guide treatment adaptation based on their changes prior to or during radiotherapy. In this article, we first present an overview of the applications of anatomical MRI sequences in head and neck radiotherapy, followed by the potentials and limitations of functional MRI sequences in personalizing therapy.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento por Ressonância Magnética/métodos , Medicina de Precisão/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Cabeça/diagnóstico por imagem , Humanos , Pescoço/diagnóstico por imagem , Oncologistas
18.
Clin Cancer Res ; 23(15): 4233-4241, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28314789

RESUMO

Purpose: To evaluate intrinsic susceptibility (IS) MRI for the identification of cycling hypoxia, and the assessment of its extent and spatial distribution, in head and neck squamous cell carcinoma (HNSCC) xenografts and patients.Experimental Design: Quantitation of the transverse relaxation rate, R2*, which is sensitive to paramagnetic deoxyhemoglobin, using serial IS-MRI acquisitions, was used to monitor temporal oscillations in levels of paramagnetic deoxyhemoglobin in human CALR xenografts and patients with HNSCC at 3T. Autocovariance and power spectrum analysis of variations in R2* was performed for each imaged voxel, to assess statistical significance and frequencies of cycling changes in tumor blood oxygenation. Pathologic correlates with tumor perfusion (Hoechst 33342), hypoxia (pimonidazole), and vascular density (CD31) were sought in the xenografts, and dynamic contrast-enhanced (DCE) MRI was used to assess patient tumor vascularization. The prevalence of fluctuations within patient tumors, DCE parameters, and treatment outcome were reported.Results: Spontaneous R2* fluctuations with a median periodicity of 15 minutes were detected in both xenografts and patient tumors. Spatially, these fluctuations were predominantly associated with regions of heterogeneous perfusion and hypoxia in the CALR xenografts. In patients, R2* fluctuations spatially correlated with regions of lymph nodes with low Ktrans values, typically in the vicinity of necrotic cores.Conclusions: IS-MRI can be used to monitor variations in levels of paramagnetic deoxyhemoglobin, associated with cycling hypoxia. The presence of such fluctuations may be linked with impaired tumor vasculature, the presence of which may impact treatment outcome. Clin Cancer Res; 23(15); 4233-41. ©2017 AACR.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neovascularização Patológica/diagnóstico por imagem , Animais , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Hipóxia Celular/genética , Linhagem Celular Tumoral , Meios de Contraste/uso terapêutico , Feminino , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Linfonodos/patologia , Masculino , Camundongos , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/patologia , Nitroimidazóis/administração & dosagem , Tolerância a Radiação/efeitos dos fármacos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Resultado do Tratamento , Ensaios Antitumorais Modelo de Xenoenxerto
19.
J Appl Clin Med Phys ; 18(2): 154-162, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28300372

RESUMO

An Active Breathing Coordinator (ABC) can be employed to induce breath-holds during CT imaging and radiotherapy of lung, breast and liver cancer, and recently during lung cancer MRI. The apparatus measures and controls respiratory volume, hence subject lung volume reproducibility is its principal measure of effectiveness. To assess ABC control quality, the intra-session reproducibility of ABC-induced lung volumes was evaluated and compared with that reached by applying the clinical standard of operator-guided self-sustained breath-holds on healthy volunteers during MRI. Inter-session reproducibility was investigated by repeating ABC-controlled breath-holds on a second visit. Additionally, lung volume agreement with ABC devices used with different imaging modalities in the same institution (MR, CT), or for a breast trial treatment, was assessed. Lung volumes were derived from three-dimensional (3D) T1-weighted MRI datasets by three observers employing semiautomatic lung delineation on a radiotherapy treatment planning system. Inter-observer variability was less than 6% of the delineated lung volumes. Lung volume agreement between the different conditions over all subjects was investigated using descriptive statistics. The ABC equipment dedicated for MR application exhibited good intra-session and inter-session lung volume reproducibility (1.8% and 3% lung volume variability on average, respectively). MR-assessed lung volumes were similar using different ABC equipment dedicated to MR, CT, or breast radiotherapy. Overall, lung volumes controlled by the same or different ABC devices agreed better than with self-controlled breath-holds, as suggested by the average ABC variation of 1.8% of the measured lung volumes (99 mL), compared to the 4.1% (226 mL) variability observed on average with self-sustained breath-holding.


Assuntos
Neoplasias da Mama/patologia , Suspensão da Respiração , Pulmão/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Neoplasias da Mama/radioterapia , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Movimento , Posicionamento do Paciente , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos
20.
Br J Cancer ; 116(1): 28-35, 2017 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-27884018

RESUMO

BACKGROUND: Patients with head and neck squamous cell carcinoma (HNSCC) undergoing radical chemo-radiation (CRT) frequently receive transfusion with packed red cells (PRCT) during radiotherapy on the basis that PRCT increases tumour oxygenation and overcomes hypoxia-induced radio-resistance. This is likely to be a significant oversimplification given the fact that tumour hypoxia is the result of several intrinsic and extrinsic factors, including many that are not directly related to serum haemoglobin (Hb). Therefore, we have studied the effect of PRCT on tumour oxygenation in a prospective cohort of patients who developed low Hb during radical CRT for HNSCC. METHODS: This was a prospective study of 20 patients with HNSCC receiving radical CRT undergoing PRCT for Hb<11.5 g dl-1. Patients underwent pretransfusion and posttransfusion intrinsic susceptibility-weighted (SWI) MRI and dynamic contrast-enhanced (DCE) MRI. Blood samples were obtained at the time of MRI scanning and two further time points for measuring Hb and a panel of serum cytokine markers of tumour hypoxia. 3D T2* and Ktrans maps were calculated from the MRI data for primary tumours and cervical lymph node metastases. RESULTS: PRCT produced no change (11 patients) or reduced (1 patient) T2* (tumour oxygenation) in 12 of the 16 (75%) evaluable primary tumours. Three of the four patients with improved tumour oxygenation progressed or had partial response following treatment completion. There were variable changes in Ktrans (tumour perfusion or vessel permeability) following PRCT that were of small magnitude for most tumours. Pre- and Post-PRCT levels of measured cytokines were not significantly different. CONCLUSIONS: This study suggests that PRCT during radical CRT for HNSCC does not improve tumour oxygenation. Therefore, oncologists should consider changing practice according to NICE and American Association of Blood Banks guidelines on PRCT for anaemia.


Assuntos
Transfusão de Sangue , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Neoplasias de Cabeça e Pescoço/terapia , Hipóxia Tumoral , Idoso , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/patologia , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Estudos Longitudinais , Metástase Linfática , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Carcinoma de Células Escamosas de Cabeça e Pescoço , Hipóxia Tumoral/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA