1.
J Surg Res ; 100(1): 99-105, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11516211

RESUMO

BACKGROUND: Uniplanar quantitative angiography (QA) is the standard method for measuring vessel diameter during surgical and endovascular procedures. Intravascular ultrasound (IVUS), a relatively new technology, is another means of obtaining this measurement. This study was designed to validate the accuracy of these two modalities by comparing each to direct caliper measurement, the gold standard, using phantom femoral artery segments (PAS). MATERIALS AND METHODS: PAS diameter was measured with a 12.5-MHz mechanically rotating IVUS catheter (Boston Scientific Corp.) and QA (OEC Corp.) was compared to the direct caliper measurement (Mitutoyo Corp.) at 60 different locations within PAS. At each location minimal lumen diameter and perpendicular lumen diameter were measured and their mean was calculated. The intraclass correlation coefficients (ICCC) between direct caliper measurement and IVUS and uniplanar and biplanar angiography were calculated. Fisher's Z transformation was used to compare the correlation coefficients. RESULTS: The ICCC for IVUS was 0.89. The ICCCs for uniplanar and biplanar angiography were 0.73 and 0.82, respectively. IVUS correlated more closely with direct caliper measurement than uniplanar and biplanar angiography (P = 0.00008, 0.02) Biplanar angiography correlated more closely with direct caliper measurement than uniplanar angiography (P = 0.04). CONCLUSIONS: IVUS more accurately measures lumen diameter than uniplanar or biplanar angiography. Diameter measurement with biplanar angiography is more accurate than uniplanar angiography.


Assuntos
Artéria Femoral/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/normas , Angiografia/métodos , Angiografia/normas , Artéria Femoral/cirurgia , Humanos , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Vasculares
2.
Ann Vasc Surg ; 15(1): 7-12, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11221948

RESUMO

The use of nonpenetrating clips (NPC) for vascular anastomosis is quickly becoming accepted. Studies attest to decreased anastomotic time, comparable patency rates, and decreased blood loss. Few human studies on the use of NPC have been done to date. The purpose of this study was to evaluate primary patency rates, operative time, and complications associated with NPC compared to those with standard sutures for arterial venous graft (AVG). We retrospectively reviewed the clinical course of 82 patients with a mean age of 45 years (range, 22 to 87) from February 1996 to July 1999. All patients underwent upper extremity AVG construction. The procedures were performed at a single institution, by a single, well-experienced surgeon who has extensive experience with NPC. Primary patency rates, operative time, and complications were analyzed. Overall thrombotic incidence of AVG when NPC were used (27/48, 56%) was similar to that of sutures (17/34, 50%). Thrombotic incidence within the first year was similar as well (23/48, 48% and 13/34, 38%). The mean time to primary thrombosis was similar in both groups (6.9 and 6.8 months). The operative time required to construct an AVG with NPC (83 min) was significantly less than that with sutures (96 min) (p = 0.015). There was no significant difference in incidence of graft infection or pseudoaneurysm formation. NPC for AVG reduced operative time and resulted in primary patency and complication rates similar to those associated with use of sutures. The mean time to primary thrombosis was similar for both groups. Our findings suggest an intimal hyperplastic response of a similar nature resulting in thrombosis of both NPC and sutured AVGs.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Instrumentos Cirúrgicos , Suturas , Adulto , Idoso , Idoso de 80 Anos ou mais , Braço/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Cateteres de Demora/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diálise Renal , Estudos Retrospectivos , Instrumentos Cirúrgicos/efeitos adversos , Suturas/efeitos adversos , Trombose/etiologia , Grau de Desobstrução Vascular
4.
J Endovasc Surg ; 6(2): 171-9, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10473336

RESUMO

PURPOSE: To examine experimentally the feasibility of transfemoral endoluminal repair of aneurysms containing the ostia of essential branch arteries. METHODS: In a canine model (n = 4), suprarenal aortic aneurysms were created by suturing an artificial patch onto an anterior arteriotomy. Following a 2-week recovery period, the dogs underwent endovascular exclusion of their aneurysms using an aortic stent-graft with separate renal artery branch grafts. Outcome was evaluated using angiography, intravascular ultrasound (IVUS), Doppler flow, invasive pressure monitoring, and autopsy, respectively. RESULTS: Successful creation and subsequent endovascular exclusion of the aneurysm using aortic stent-grafts and separate bilateral renal artery stent-grafts was achieved in all trials. Angiographically, all aneurysms were excluded from aortic flow and all renal arteries were patent at completion of the procedure. With IVUS, good graft apposition and absence of perigraft flow were demonstrated in all animals. Mean pressure in the aneurysmal sac at completion of the procedure was 40 +/- 7 mmHg, compared to a mean systemic blood pressure of 105 +/- 8 mmHg (p < 0.05). At autopsy, no gross intimal damage was seen in the aorta or the renal arteries, and intact aortic grafts and branch grafts without twisting, coiling, or kinking were found in all trials. CONCLUSIONS: In an acute animal model, suprarenal aortic aneurysms can be excluded from the circulation with preservation of renal flow using an endoluminally placed aortic stent-graft with separate branch grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Doença Aguda , Angiografia , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Modelos Animais de Doenças , Cães , Seguimentos , Projetos Piloto , Polietilenotereftalatos , Politetrafluoretileno , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Stents , Ultrassonografia Doppler , Ultrassonografia de Intervenção
5.
J Endovasc Surg ; 6(3): 246-50, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10495152

RESUMO

PURPOSE: To report an examination of explanted bifurcated endovascular aortic grafts for histologic evidence of early healing and incorporation. METHOD: Two bifurcated endovascular aortic grafts composed of polycarbonate urethane and Elgiloy wire were explanted 42 and 21 days after successful endovascular exclusion of abdominal aortic aneurysms. Both patients expired from causes unrelated to endograft deployment. The explanted devices were examined using immunohistochemical analysis and electron microscopy. RESULTS: On explantation, both grafts appeared to have excluded the aneurysm with no evidence of endoleak, graft migration, or thrombosis. Histological examination showed numerous inflammatory cells and good ingrowth of tissue into the proximal 2 cm of the graft. Collagen and smooth muscle cells were evident in the proximal portion of the graft with only collagen in the distal segments. Neointimal formation was seen within the proximal 2 cm also, but not at the distal segments. Macrophages were present in the graft. Scanning electron microscopy showed an extensive matrix of fibers that most likely represented collagen. CONCLUSIONS: Bifurcated endovascular aortic grafts show inflammatory and mild foreign body reactions, collagen formation, and intimal ingrowth during healing. These findings are similar to some of the healing properties reported for sutured grafts, as well as other endovascular grafts.


Assuntos
Aorta Abdominal/ultraestrutura , Aneurisma da Aorta Abdominal/cirurgia , Cicatrização , Actinas/imunologia , Idoso , Anticorpos/análise , Aorta Abdominal/imunologia , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/patologia , Implante de Prótese Vascular , Materiais Revestidos Biocompatíveis , Colágeno/ultraestrutura , Endotélio Vascular/imunologia , Endotélio Vascular/ultraestrutura , Fator VIII/imunologia , Evolução Fatal , Feminino , Reação a Corpo Estranho/imunologia , Reação a Corpo Estranho/patologia , Células Gigantes de Corpo Estranho/imunologia , Células Gigantes de Corpo Estranho/ultraestrutura , Humanos , Masculino , Músculo Liso Vascular/imunologia , Músculo Liso Vascular/ultraestrutura , Polímeros , Poliuretanos
6.
J Vasc Surg ; 30(3): 555-60, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10477650

RESUMO

We report an unusual case of type IV Thoracoabdominal Aneurysm (TAA) with Superior Mesenteric Artery (SMA), celiac artery, and bilateral renal artery aneurysms in a patient who underwent an earlier repair of two infrarenal Abdominal Aortic Aneurysm (AAA) ruptures. Because of the presence of the visceral artery aneurysms and the earlier operation through the retroperitoneum, standard surgical treatment via a retroperitoneal approach with an inclusion grafting technique was considered difficult. A combined surgical approach achieving retrograde perfusion of all four visceral vessels and endovascular grafting allowing exclusion of the TAA was accomplished. Complete exclusion of the aneurysm and normal perfusion of the patient's viscera was documented by means of follow-up examinations at 3 and 6 months. The repair of a type IV TAA with a Combined Endovascular and Surgical Approach (CESA) allowed us to manage both the aortic and visceral aneurysms without thoracotomy or re-do retroperitoneal exposure and minimized visceral ischemia time. If the durability of this approach is confirmed, it may represent an attractive alternative in patients with aneurysmal involvement of the visceral segment of the aorta.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Anastomose Cirúrgica/métodos , Aneurisma/complicações , Aneurisma/cirurgia , Aneurisma da Aorta Abdominal/classificação , Aneurisma da Aorta Torácica/classificação , Ruptura Aórtica/cirurgia , Artéria Celíaca/patologia , Artéria Celíaca/cirurgia , Seguimentos , Humanos , Masculino , Artéria Mesentérica Superior/patologia , Artéria Mesentérica Superior/cirurgia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Fluxo Sanguíneo Regional/fisiologia , Artéria Renal/patologia , Artéria Renal/cirurgia , Espaço Retroperitoneal/cirurgia , Stents
7.
J Vasc Surg ; 27(1): 109-16, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9474088

RESUMO

PURPOSE: The medium molecular weight fraction of pentastarch (HES-Pz) has been shown to decrease reperfusion injury to myocardium and brain by reducing capillary leak. This study was undertaken to assess the effects of HES-Pz on neurologic function, microvascular permeability, and spinal cord infarction after temporary aortic cross-clamping in a rabbit model. METHODS: In 30 New Zealand White rabbits, a snare occlusion device was placed around the infrarenal aorta and tunneled into a subcutaneous position. Animals were allowed to recover for 48 hours and were randomized into three groups. In each group, the infrarenal aorta was occluded by tightening the snare in the awake animal for 21 minutes. Immediately after unclamping, animals received an intravenous infusion of 4% of their estimated blood volume of one of the following solutions: normal saline solution (NS; group 1); 6% standard hydroxyethyl starch (HES), molecular weight 10 to 3400 kD (group 2); and 6% HES-Pz, molecular weight 100 to 1000 kD (group 3). During 5 days of observation, neurologic recovery was graded by an independent observer using the Tarlov scale. Animals were then killed and their spinal cords harvested for histologic examination using hematoxylin-eosin and 2,3,5-triphenyltetrazolium chloride staining. In a separate group of animals (n = 15), the occurrence of spinal cord capillary permeability after NS, HES, and HES-Pz infusions was evaluated by spectrophotometric analysis of extravasated Evans blue. RESULTS: Complete paraplegia and marked histologic evidence of spinal cord cellular injury were seen in 90% of group 1 (NS) and in 78% of group 2 (HES). Treatment with HES-Pz (group 3) resulted in full neurologic recovery in 89% of animals (p < 0.05) and a threefold reduction of extravasated Evans blue compared with controls (p < 0.05). CONCLUSIONS: These results indicate that microvascular hyperpermeability plays an important role in reperfusion injury to the spinal cord. Treatment with HES-Pz reduced the capillary permeability, neuron membrane injury, and incidence of paraplegia after reperfusion of ischemic spinal cord in a rabbit model.


Assuntos
Permeabilidade Capilar , Derivados de Hidroxietil Amido/uso terapêutico , Isquemia/fisiopatologia , Substitutos do Plasma/uso terapêutico , Traumatismo por Reperfusão/prevenção & controle , Medula Espinal/irrigação sanguínea , Animais , Peso Molecular , Paraplegia/etiologia , Paraplegia/prevenção & controle , Coelhos , Traumatismo por Reperfusão/patologia , Traumatismo por Reperfusão/fisiopatologia , Cloreto de Sódio/administração & dosagem , Medula Espinal/patologia
8.
J Vasc Surg ; 24(6): 1017-21, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8976355

RESUMO

Neurologic injury is one of the most devastating complications of combined carotid and cardiac procedures. Although the cause of the deficit is usually embolic, the exact cause is often not apparent at the time of surgery. We present a complex case of combined carotid endarterectomy, innominate artery reconstruction, and coronary artery bypass procedures in which intraoperative monitoring with somatosensory evoked potentials and transcranial Doppler ultrasonography combined with postoperative acetazolamide single photon emission computed tomographic scans was used to correlate intraoperative events with cerebral activity and functional results. Although computed tomographic scan, magnetic resonance imaging, and clinical evaluation were negative for any evidence of stroke, the patient exhibited subtle postoperative changes in neuropsychologic function. These changes were correlated with intraoperative microemboli detected by transcranial Doppler monitoring, and postoperative acetazolamide single photon emission computed tomographic scanning, which revealed bilateral cortical defects.


Assuntos
Tronco Braquiocefálico/cirurgia , Ponte de Artéria Coronária , Endarterectomia das Carótidas , Embolia e Trombose Intracraniana/complicações , Monitorização Intraoperatória/métodos , Complicações Pós-Operatórias/etiologia , Acetazolamida , Idoso , Potenciais Somatossensoriais Evocados , Humanos , Embolia e Trombose Intracraniana/diagnóstico , Complicações Intraoperatórias/diagnóstico , Masculino , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único , Ultrassonografia Doppler Transcraniana
9.
Cardiovasc Surg ; 4(1): 77-80, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8634852

RESUMO

Controversy exists over the value of intraoperative monitoring and shunting in patients undergoing carotid endarterectomy. Although it is widely believed that contralateral carotid occlusion and previous stroke mandate intraoperative shunting, the susceptibility of these two groups of patients to cerebral ischemia during carotid artery endarterectomy is not well defined. Somatosensory evoked potentials (SSEPs) were monitored in 113 carotid artery endarterectomy patients. Of these, 32 (28.3%) had a previous stroke, 24 (21.2%) had a contralateral carotid occlusion and 33 (29.2%) were diabetic. There were no deaths and only one perioperative stroke (0.9%). Cerebral ischemia occurred in 14 patients (12.4%). Six of these patients had a contralateral carotid occlusion. Some 29 patients (25.7%) were shunted, including 10 with contralateral carotid occlusions that did not have major SSEP changes. In the latter half of the study, 14 patients with contralateral carotid occlusions were selectively shunted (six shunted, eight not shunted) with no neurological complications. Thirty-two patients with prior strokes were selectively shunted (nine shunted, 23 not shunted); of these, one shunted patient undergoing combined carotid artery endarterectomy and coronary artery bypass grafting had a perioperative stroke. Intraoperative monitoring with SSEPs accurately identifies cerebral ischemia secondary to carotid clamping as well as patients requiring shunts. With use of intraoperative SSEP monitoring, selective shunting may be safely performed in patients with a contralateral carotid occlusion or a previous stroke.


Assuntos
Endarterectomia das Carótidas , Potenciais Somatossensoriais Evocados/fisiologia , Monitorização Intraoperatória , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/etiologia , Estenose das Carótidas/patologia , Estenose das Carótidas/cirurgia , Transtornos Cerebrovasculares/etiologia , Ponte de Artéria Coronária/efeitos adversos , Complicações do Diabetes , Suscetibilidade a Doenças , Endarterectomia das Carótidas/efeitos adversos , Humanos , Complicações Intraoperatórias , Pessoa de Meia-Idade , Exame Neurológico , Estudos Retrospectivos , Taxa de Sobrevida
10.
J Thorac Cardiovasc Surg ; 109(5): 976-80, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7739259

RESUMO

The postoperative fluid retention found in some patients after the Cox maze procedure has been attributed to surgically induced loss of atrial natriuretic peptide. We postulated that exogenous atrial natriuretic peptide could reverse this antidiuresis. A rat model was used to investigate this hypothesis. In group I, the sham group, the atrial appendages were left intact and the animals were then subjected to a fluid challenge equivalent to 1% of the animal's body weight. In group II, after biatrial appendectomy, the animals were subjected to a fluid challenge similar to that in group I. Animals in group III underwent the same protocol as that for group II plus intravenous administration of atriopeptin III at varying concentrations. Urine output and plasma atrial natriuretic peptide levels were significantly decreased after biatrial appendectomies (p < or = 0.01). Urine output returned to control levels after biatrial appendectomies with low-dose atrial natriuretic peptide infusion (0.5 pmol/min = 25.5 pg/min), although circulating atrial natriuretic peptide levels were lower. Urine output and plasma atrial natriuretic peptide levels increased with atrial natriuretic peptide infusions between 0.5 and 50 pmol/min. Heart rate and mean blood pressure did not vary significantly with atrial natriuretic peptide infusions. Thus atrial natriuretic peptide can be used effectively in low doses to induce a diuresis after biatrial appendectomies. Atrial natriuretic peptide may have clinical application after the Cox maze procedure.


Assuntos
Fator Natriurético Atrial/farmacologia , Diurese/efeitos dos fármacos , Átrios do Coração/cirurgia , Animais , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Masculino , Métodos , Fragmentos de Peptídeos , Ratos , Ratos Sprague-Dawley
12.
J Vasc Surg ; 20(3): 466-72; discussion 472-3, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8084041

RESUMO

PURPOSE: Intravascular stents have become important tools for the management of vascular lesions; however, stents in combination with vascular grafts have only recently reached clinical application. This report describes an experience with stented grafts for the treatment of penetrating arterial trauma. METHODS: Seven transluminally placed stented grafts were used to treat one arteriovenous fistula and six pseudoaneurysms. These grafts were successfully inserted percutaneously or through open arteriotomies that were remote from the site of vascular trauma. The devices were composed of balloon-expandable stainless steel stents covered with polytetrafluoroethylene grafts. RESULTS: Patency up to 14 months was achieved (mean follow-up 6.5 months) with these stented grafts. The use of stented grafts appears to be associated with decreased blood loss, a less invasive insertion procedure, reduced requirements for anesthesia, and a limited need for an extensive dissection in the traumatized field. These advantages are particularly important in patients with central arteriovenous fistulas or false aneurysms who are critically ill from other coexisting injuries or medical comorbidities. CONCLUSIONS: The use of stented grafts already appears justified to treat traumatic arterial lesions in critically ill patients. Although the early results with the seven cases in this report are encouraging, documentation of long-term effectiveness must be obtained before these devices can be recommended for widespread or generalized use in the treatment of major arterial injuries.


Assuntos
Falso Aneurisma/terapia , Fístula Arteriovenosa/terapia , Prótese Vascular/instrumentação , Cateterismo , Politetrafluoretileno , Stents , Ferimentos Penetrantes/terapia , Adulto , Idoso , Falso Aneurisma/etiologia , Falso Aneurisma/fisiopatologia , Fístula Arteriovenosa/etiologia , Fístula Arteriovenosa/fisiopatologia , Prótese Vascular/métodos , Terapia Combinada , Feminino , Artéria Femoral/lesões , Veia Femoral/lesões , Seguimentos , Humanos , Artéria Ilíaca/lesões , Masculino , Artéria Subclávia/lesões , Grau de Desobstrução Vascular , Ferimentos Penetrantes/complicações
14.
Am J Surg ; 168(2): 156-62, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8053517

RESUMO

BACKGROUND: Endovascular stented grafts employ a new technique that blends intravascular stent and prosthetic graft technologies. These devices may be used to treat arterial aneurysms, occlusive disease, and vascular injuries. This report describes the application of stented grafts to the treatment of limb-threatening ischemia secondary to occlusive disease of the aorta, iliac, and femoral arteries. METHODS: Three patients with limb-threatening ischemia and severe comorbid medical illnesses were treated with transvascular stented grafts that were composed of 6-mm thin-walled polytetrafluoroethylene grafts and Palmaz balloon expandable stents. The grafts were inserted through a cutdown in an artery remote from the site of occlusion and introduced into the vascular system within 14-Fr introducer sheaths. RESULTS: Technical success was documented in all three patients with restoration of arterial continuity following stent graft deployment. Patency and limb salvage has been achieved to 1 year. One patient required further dilatation of the proximal stent at 6 weeks. Complications were limited to an iliofemoral deep vein thrombosis in one patient. CONCLUSIONS: Endovascular stented grafts can be inserted to treat limb-threatening ischemia. Although these initial results are encouraging, greater experience in more patients observed for longer periods of time is necessary before this technique can be advocated for widespread use.


Assuntos
Doenças da Aorta/terapia , Arteriopatias Oclusivas/terapia , Prótese Vascular , Cateterismo/métodos , Artéria Femoral/cirurgia , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Politetrafluoretileno , Artéria Poplítea/cirurgia , Stents , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Cateterismo/instrumentação , Terapia Combinada , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Gangrena , Humanos , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Complicações Pós-Operatórias , Radiografia , Grau de Desobstrução Vascular
15.
Am J Surg ; 168(2): 97-101, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8053535

RESUMO

We reviewed 95 cases of vein graft and anastomotic lesions treated with percutaneous transluminal balloon angioplasty (PTA) and 30 cases treated surgically. The therapy was deemed a failure if the lesion recurred or if the graft closed. The 21-month patency rate of lesions treated surgically was 86%, which was significantly better than the 42% patency rate for all lesions treated with PTA (P < 0.01). An evaluation of the lesion and graft characteristics that could influence the patency of stenotic lesions treated with PTA included: lesion length, minimum graft diameter, lesion location, and lesion type. The 66% patency rate at 24 months for the 41 simple lesions (single, nonrecurrent, < 15 mm in length, and within grafts > or = 3 mm minimal diameter) was significantly better than the 17% patency rate for the 50 complex lesions (multiple, recurrent, > or = 15 mm in length, or within grafts < 3 mm in minimal diameter) (P < 0.01). In addition, the 21-month patency rate for the surgically treated group (86%) was not significantly better than that of the angioplasty-treated simple lesions (66%). When feasible, vein graft lesions are best treated with simple surgical interventions. PTA can be useful to maintain the patency of severely compromised grafts prior to surgical repair, to treat simple lesions difficult to reach surgically, and for patients with medical contraindications for an operation.


Assuntos
Angioplastia com Balão , Prótese Vascular , Oclusão de Enxerto Vascular/terapia , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Veia Safena/transplante , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/efeitos adversos , Feminino , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Grau de Desobstrução Vascular
16.
J Vasc Surg ; 20(1): 61-68; discussion 68-9, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8028091

RESUMO

PURPOSE: The absence of sufficient length of suitable autologous vein occasionally prohibits the treatment of severe distal lower extremity arterial occlusive disease with a standard distal bypass originating from the common femoral artery. During the past 11 years, we have therefore selectively performed short distal bypasses originating from the infrapopliteal arteries in patients with limb-threatening ischemia and occlusive lesions limited to the distal tibial and peroneal arteries. This report summarizes our experience with these tibial artery based distal bypasses. METHODS: Forty-two distal lower extremity arterial bypasses originating from infrapopliteal arteries in 41 patients were performed over an 11-year period. Autologous vein was used as the bypass conduit in all cases. Extensions from a more proximal bypass were excluded. RESULTS: The primary patency rate of these tibiotibial bypasses was 77% at 1 year and 62% after 5 years. The limb salvage rate after 5 years was 74%. The perioperative mortality rate was low (2%), but the 5-year patient survival rate (64%) was similar to that with more standard lower extremity arterial reconstructive procedures. CONCLUSIONS: Tibiotibial bypass is an effective limb salvage procedure in carefully selected patients with distal tibial artery occlusive disease and limited autologous vein. It offers a durable means of distal revascularization in circumstances in which a standard operation might not be desirable or possible.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artérias da Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Oclusão de Enxerto Vascular , Humanos , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplante Autólogo , Resultado do Tratamento , Veias/transplante
17.
J Vasc Surg ; 19(4): 754-7, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8164291

RESUMO

This report describes the use of an endoluminally placed stented graft to repair a large (2.6 by 2.6 by 15 cm) popliteal aneurysm in a 63-year-old man with advanced heart disease. Two balloon-expandable stents were attached to a 6 mm polytetrafluoroethylene graft, which was inserted with the patient receiving local anesthetic through a proximal superficial femoral artery arteriotomy. Repeat arteriography and duplex ultrasonography performed up to 3 months after the procedure documented graft and distal artery patency and complete aneurysmal exclusion without distal emboli. This experience demonstrates technical feasibility and early graft patency. However, additional experience and follow-up will be needed to assess the value of this minimally invasive procedure in the management of popliteal aneurysmal disease.


Assuntos
Aneurisma/cirurgia , Prótese Vascular , Artéria Poplítea , Stents , Aneurisma/epidemiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese
18.
Cardiovasc Surg ; 2(1): 56-62, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8049926

RESUMO

This study describes the varied histologic features and ultrastructure of human saphenous veins obtained from patients undergoing infrainguinal arterial reconstruction. Portions of 30 remnant veins were fixed at arterial pressure (100 mmHg). Vein specimens were obtained from 13 men and 17 women, with a mean age of 70.2 years. Ten veins (33%) were from diabetic patients. Samples of fixed veins were prepared for light and electron microscopy. The luminal surface contained valves and redundant intimal folds at the site of ligated side branches. Microvalves were present at the orifices of several 1-mm vein tributaries. The endothelial cells lining the intima were often discontinuous and were aligned in a variable pattern. The thicknesses of the vein walls varied from 20 to 360 microns, with increased connective tissue matrix in the intima and medial layers of thick-walled veins. Some 10% of the veins demonstrated spindle cells in the intima; these cells had a smooth muscle cell phenotype and varied with respect to the degree of cellular differentiation. Regions of vein wall calcification were occasionally seen and were always present in association with a thickened vein intima. Variations in the structure of the saphenous vein from patients undergoing bypass surgery are common. The relationship between altered saphenous vein morphology and subsequent vein graft stenosis needs to be defined.


Assuntos
Veia Safena/citologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão e Varredura , Pessoa de Meia-Idade , Veia Safena/ultraestrutura , Túnica Íntima/citologia
19.
J Vasc Surg ; 18(6): 981-9; discussion 989-90, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8264055

RESUMO

PURPOSE: The purpose of this study was to review the 91 failing polytetrafluoroethylene (PTFE) grafts that were treated at our institution over the past 12 years to better understand their cause and improve the diagnosis and treatment of these grafts. METHODS: Eighty-five patients with 91 failing grafts were retrospectively reviewed. The 144 graft-threatening lesions associated with these grafts were characterized by location (inflow artery, outflow artery, anastomosis, or graft body) and treatment method used (surgery, balloon angioplasty, or thrombolysis). RESULTS: Progression of atherosclerotic disease was the predominant cause of failing PTFE grafts with 43 inflow lesions and 83 outflow lesions, accounting for 87% of all lesions identified. Ten lesions (7%) were noted within the prosthetic grafts, whereas only eight (6%) lesions were noted at the anastomoses. Forty stenotic lesions 2 cm in length or less were treated with percutaneous transluminal balloon angioplasty, whereas 100 lesions were treated by patch angioplasty or graft extensions. The remaining four lesions, present within the prosthetic grafts, were treated with thrombolytic therapy. The 5-year cumulative patency rate for all failing PTFE grafts was 71%, whereas that of failing femoropopliteal PTFE grafts was 64%. The 5-year limb salvage rate for all failing PTFE grafts was 73%. CONCLUSIONS: The progression of inflow and outflow disease is the predominant cause of failing PTFE grafts, which suggests that this process is a more important cause of PTFE graft thrombosis than is generally recognized. Frequent PTFE graft surveillance may permit detection of some threatening lesions before graft thrombosis occurs and may help maintain and prolong graft patency. The enhanced 5-year patency and limb salvage rates for treated failing PTFE grafts compared with the known poor outcome after reinterventions for PTFE graft failure support the conclusion that surveillance of PTFE grafts is worthwhile.


Assuntos
Prótese Vascular , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Perna (Membro)/cirurgia , Politetrafluoretileno , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Falha de Prótese , Estudos Retrospectivos , Terapia Trombolítica , Fatores de Tempo , Grau de Desobstrução Vascular
20.
J Vasc Surg ; 18(3): 407-14; discussion 414-5, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8377234

RESUMO

PURPOSE: To determine why some vein grafts fail, we prospectively studied the relationship between the histologic condition of the greater saphenous vein (GSV) at the time of grafting and subsequent stenosis of the vein graft. METHODS: Ninety-four remnant segments of GSVs were obtained at the time of infrainguinal bypass in 91 patients and were perfusion fixed before histologic and ultrastructural examination. All bypass grafts were evaluated clinically and by duplex ultrasonography at regular intervals from 1 to 30 months after operation. All 24 grafts that developed lesions that caused thrombosis (failed grafts) or flow reduction (failing grafts) underwent arteriography and appropriate operative or other interventional correction of the causative lesion. RESULTS: There was no significant difference in the incidence of coronary artery disease, kidney disease, hypertension, or history of smoking in patients with normally functioning and failed or failing grafts. Diabetes occurred with an increased frequency in failed or failing grafts (p = 0.056). At the time of their insertion, GSVs that subsequently developed significant lesions had thicker walls (0.72 +/- 0.33 mm) compared with normally functioning grafts (0.58 +/- 21 mm; p < 0.02). Most of this difference was related to a significantly thicker intima (0.27 +/- 0.17 vs 0.11 +/- 0.7 mm; p < 0.0001). Another significant finding was the presence of subendothelial spindle-shaped cells greater than five cell layers thick. This occurred more often in pregraft biopsies from grafts that developed significant lesions (70.4% vs 7.5%, p < 0.0001). Electron microscopic examination of these cells demonstrated a subpopulation of poorly differentiated cells with few fibers and many vesicles. Four of 24 (17%) failed or failing grafts had evidence of vein wall calcification at the time of vein grafting. This was seen in only one (1.4%) of 70 normally functioning grafts without lesions (p < 0.005). CONCLUSIONS: We conclude that GSVs with thick and calcified walls or hypercellular intima at the time of grafting are at increased risk of developing intragraft lesions that may lead to graft failure. Frequent duplex ultrasonography surveillance is particularly warranted for such high-risk grafts.


Assuntos
Oclusão de Enxerto Vascular/patologia , Veia Safena/patologia , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Veia Safena/cirurgia