Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiat Prot Dosimetry ; 150(3): 306-11, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22234422

RESUMO

Radiation exposure of the operator during cardiac catheter ablation procedures was assessed for an experienced cardiologist adopting various measures of radiation protection and utilised electroanatomic navigation. Chip thermoluminescent dosemeters were placed at the eyes, chest, wrists and legs of the operator. The ranges of fluoroscopy time and air kerma area product values associated with cardiac ablation procedures were wide (6.3-48.3 min and 1.7-80.3 Gy cm(2), respectively). The measured median radiation doses per procedure for each monitored position were 23.6 and 21.3 µSv to the left and right wrists, respectively, 25.3 and 30.4 µSv to the left and right legs, respectively. The doses to the eyes were below the minimum detectable dose of 9 µSv. The estimated median effective dose was 22.5 µSv. Considering the actual workload of the operator, the calculated annual doses to the hands, legs and eyes, as well as the annual effective dose, were all below the corresponding limits. The findings of this study indicate that cardiac ablation procedures performed at a modern laboratory do not impose a high radiation hazard to the operator when radiation protection measures are routinely adopted.


Assuntos
Arritmias Cardíacas/terapia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Exposição Ocupacional/prevenção & controle , Proteção Radiológica , Adulto , Idoso , Ablação por Cateter/normas , Técnicas Eletrofisiológicas Cardíacas/normas , Olho/efeitos da radiação , Feminino , Fluoroscopia , Humanos , Perna (Membro)/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/análise , Radiografia Intervencionista , Dosimetria Termoluminescente , Tórax/efeitos da radiação , Punho/efeitos da radiação , Adulto Jovem
2.
Radiat Prot Dosimetry ; 148(1): 83-91, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21324959

RESUMO

Prospective ECG triggering has the potential of reducing radiation exposure while maintaining diagnostic accuracy of cardiac computed tomography (CT). The aim of this study is to review patient radiation doses associated with coronary artery calcium scoring (CACS) and CT coronary angiography (CTCA) and to compare results between prospective and retrospective acquisition schemes. Patient radiation doses from CACS and CTCA were extracted from 67 relevant studies. Mean effective dose for CACS and CTCA with prospective ECG triggering is significantly lower than retrospective acquisition, 0.9±0.4 vs. 3.1±1.4 mSv, p < 0.001, and 3.4±1.4 vs. 11.1±5.4 mSv, p < 0.001, respectively. In both cardiac CT examinations, application of dose modulation techniques result in significantly lower doses in retrospective schemes, however, even with dose modulation, retrospective acquisition is associated with significantly higher doses than prospective acquisition. The number of slices acquired per rotation and the number of X-ray sources of the CT scanner (single or dual source) do not have a significant effect on patient dose.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doses de Radiação , Proteção Radiológica/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Carga Corporal (Radioterapia) , Humanos , Publicações Periódicas como Assunto/estatística & dados numéricos , Estudos Prospectivos , Proteção Radiológica/métodos , Estudos Retrospectivos
3.
Br J Radiol ; 84(1000): 293-303, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21266399

RESUMO

OBJECTIVES: CT is a valuable tool in diagnostic radiology but it is also associated with higher patient radiation doses compared with planar radiography. The aim of this article is to review patient dose for the most common types of CT examinations reported during the past 19 years. METHODS: Reported dosimetric quantities were compared with the European diagnostic reference levels (DRLs). Effective doses were assessed with respect to the publication year and scanner technology (i.e. single-slice vs multislice). RESULTS: Considerable variation of reported values among studies was attributed to variations in both examination protocol and scanner design. Median weighted CT dose index (CTDI(w)) and dose length product (DLP) are below the proposed DRLs; however, for individual studies the DRLs are exceeded. Median reported effective doses for the most frequent CT examinations were: head, 1.9 mSv (0.3-8.2 mSv); chest, 7.5 mSv (0.3-26.0 mSv); abdomen, 7.9 mSv (1.4-31.2 mSv); and pelvis, 7.6 mSv (2.5-36.5 mSv). CONCLUSION: The introduction of mechanisms for dose reduction resulted in significantly lower patient effective doses for CT examinations of the head, chest and abdomen reported by studies published after 1995. Owing to the limited number of studies reporting patient doses for multislice CT examinations the statistical power to detect differences with single-slice scanners is not yet adequate.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Tomografia Computadorizada por Raios X/métodos
4.
Br J Radiol ; 84(997): 70-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21172967

RESUMO

OBJECTIVES: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. METHODS: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. RESULTS: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 µSv, maximum 5239 µSv) and left finger (average 324 µSv, maximum 2877 µSv), whereas lower doses were recorded for the legs (average 124 µSv, maximum 1959 µSv) and the eyes (average 64 µSv, maximum 1129 µSv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 µSv, maximum 41 µSv) and legs (average 18 µSv, maximum 22 µSv), whereas doses to the eyes were minimal (average 4 µSv, maximum 16 µSv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 µSv/1000 cGy cm² and KAP was poorly correlated to the interventionists' extremity doses. CONCLUSION: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.


Assuntos
Extremidades/efeitos da radiação , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/normas , Radiologia Intervencionista , Feminino , Humanos , Masculino , Corpo Clínico Hospitalar , Doses de Radiação , Radiologia Intervencionista/métodos
5.
Phys Med Biol ; 54(17): 5209-22, 2009 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-19671974

RESUMO

Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 +/- 0.6 mSv versus 13.4 +/- 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doses de Radiação , Técnicas de Imagem de Sincronização Cardíaca/efeitos adversos , Angiografia Coronária/efeitos adversos , Eletrocardiografia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA