Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 211
Filtrar
1.
Ann Gastroenterol Surg ; 8(5): 761-773, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39229569

RESUMO

This review article explores advanced surgical approaches and anatomical insights for tailoring rectal cancer surgery, particularly focusing on low-lying rectal cancer. With the evolution of imaging technologies, precise preoperative planning has become possible, enhancing the visualization of anatomy surrounding the rectum and enabling more accurate assessments of circumferential resection margin (CRM) involvement. The article emphasizes the dynamic nature of rectal cancer treatment, advocating for individualized surgical planning based on comprehensive preoperative imaging and intraoperative assessment. This approach aims to optimize patient care by integrating recent advancements and anatomical insights into clinical practice for the management of low-lying rectal cancer. Particularly, the article discusses the importance of customizing the excision of Denonvilliers' fascia (DVF) based on tumor characteristics for optimal oncologic and functional outcomes, especially for anteriorly located tumors. It highlights the need for precise dissection techniques to ensure a negative CRM while preserving critical anatomical structures. Additionally, the review addresses the surgical management of tumors at the anorectal ring and introduces the Gate Approach for deep anterolateral pelvic dissection. Special attention is given to tumors impacting the membranous and prostate urethra, emphasizing tailored surgical approaches to balance complete tumor resection with the preservation of urogenital functions.

2.
JAMA Surg ; 159(7): 737-746, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38656413

RESUMO

Importance: Surgical site infections (SSIs) are prevalent hospital-acquired infections with significant patient impacts and global health care burdens. The World Health Organization recommends using wound protector devices in abdominal surgery as a preventive measure to lower the risk of SSIs despite limited evidence. Objective: To examine the efficacy of a dual-ring, plastic wound protector in lowering the SSI rate in open gastrointestinal (GI) surgery irrespective of intra-abdominal contamination levels. Design, Setting, and Participants: This multicenter, patient-blinded, parallel-arm randomized clinical trial was conducted from August 2017 to October 2022 at 13 hospitals in an academic setting. Patients undergoing open abdominal bowel surgery (eg, for bowel perforation) were eligible for inclusion. Intervention: Patients were randomized 1:1 to a dual-ring, plastic wound protector to protect the incision site of the abdominal wall (experimental group) or a conventional surgical gauze (control group). Main Outcomes and Measures: The primary end point was the rate of SSI within 30 days of open GI surgery. Results: A total of 458 patients were randomized; after 1 was excluded from the control group, 457 were included in the intention-to-treat analysis (mean [SD] age, 58.4 [12.1] years; 256 [56.0%] male; 341 [74.6%] with a clean-contaminated wound): 229 in the wound protector group and 228 in the surgical gauze group. The overall SSI rate in the intention-to-treat analysis was 15.7% (72 of 458 patients). The SSI rate for the wound protector was 10.9% (25 of 229 patients) compared with 20.5% (47 of 229 patients) with surgical gauze. The wound protector significantly reduced the risk of SSI, with a relative risk reduction (RRR) of 46.81% (95% CI, 16.64%-66.06%). The wound protector significantly decreased the SSI rate for clean-contaminated wounds (RRR, 43.75%; 95% CI, 3.75%-67.13%), particularly for superficial SSIs (RRR, 42.50%; 95% CI, 7.16%-64.39%). Length of hospital stay was similar in both groups (mean [SD], 15.2 [10.5] vs 15.3 [10.2] days), as were the overall postoperative complication rates (20.1% vs 18.8%). Conclusions and Relevance: This randomized clinical trial found a significant reduction in SSI rates when a plastic wound protector was used during open GI surgery compared with surgical gaze, supporting the World Health Organization recommendation for use of wound protector devices in abdominal surgery. Trial Registration: ClinicalTrials.gov Identifier: NCT03170843.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Infecção da Ferida Cirúrgica , Humanos , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Masculino , Feminino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Idoso , Plásticos , Bandagens , Método Simples-Cego
3.
BMC Cancer ; 24(1): 397, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553680

RESUMO

BACKGROUND: High-risk stage III colon cancer has a considerably poorer prognosis than stage II and low-risk stage III colon cancers. Nevertheless, most guidelines recommend similar adjuvant treatment approaches for all these stages despite the dearth of research focusing on high-risk stage III colon cancer and the potential for improved prognosis with intensive adjuvant treatment. Given the the proven efficacy of triplet chemotherapy in metastatic colorectal cancer treatment, the goal of this study is to evaluate the oncologic efficacy and safety of mFOLFIRINOX in comparison to those of the current standard of care, mFOLFOX 6, as an adjuvant treatment for patients diagnosed with high-risk stage III colon cancer after radical resection. METHODS: This multicenter, randomized (1:1), open-label, phase II trial will assess and compare the effectiveness and toxicity of mFOLFIRINOX and mFOLFOX 6 in patients with high-risk stage III colon cancer after radical resection. The goal of the trial is to enroll 312 eligible patients, from 11 institutes, aged between 20 and 70 years, with an Eastern Cooperative Oncology Group (ECOG) performance status of 0-2, or between 70 and 75 with an ECOG performance status of 0. Patients will be randomized into two arms - Arm A, the experimental arm, and Arm B, the reference arm - and will receive 12 cycles of mFOLFIRINOX and mFOLFOX 6 every 2 weeks, respectively. The primary endpoint of this study is the 3-year disease-free survival, and secondary endpoints include the 3-year overall survival and treatment toxicity. DISCUSSION: The Frost trial would help determine the oncologic efficacy and safety of adjuvant triplet chemotherapy for high-risk stage III colon cancers and ultimately improve prognoses. TRIAL REGISTRATION: ClinicalTrials.gov NCT05179889, registered on 17 December 2021.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias do Colo , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Quimioterapia Adjuvante , Ensaios Clínicos Fase II como Assunto , Neoplasias do Colo/patologia , Intervalo Livre de Doença , Estudos Multicêntricos como Assunto , Intervalo Livre de Progressão , Ensaios Clínicos Controlados Aleatórios como Assunto , Fluoruracila/uso terapêutico
4.
Ir J Med Sci ; 193(1): 51-56, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37450256

RESUMO

BACKGROUND: It is difficult to predict the expected survival after lumbar instrumented surgery for metastases owing to the difference among different cancer origins and the relatively short survival after surgery. AIMS: The aim of this study is to analyze the postoperative survival period of lumbar spinal metastasis patients who underwent lumbar instrumented surgery. METHODS: Data were collected from the Korean National Health Insurance Review and Assessment Service database. Patients who underwent lumbar spinal surgery with instrumentation between January 2011 and December 2015 for metastatic lumbar diseases were reviewed. The mean postoperative survival period of patients with metastatic lumbar cancer according to each primary cancer type was evaluated. RESULTS: A total of 628 patients were enrolled and categorized according to primary cancer type. The overall median survival rate was 1.11±1.30 years. The three most prevalent primary cancer groups were lung, hepatobiliary, and colorectal cancers, presenting relatively short postoperative survival rates (0.93±1.25, 0.74±0.75 and 0.74±0.88 years, respectively). The best postoperative survival period was observed in breast cancer (2.23±1.83 years), while urinary tract cancer showed the shortest postoperative survival period (0.59±0.69 years). CONCLUSION: The postoperative survival period of patients with lumbar metastatic spinal tumors according to different primary cancers after instrumented fusion was ˃1 year overall, with differences according to different primary origins. This result may provide information regarding the expected postoperative survival after instrumented surgery for lumbar spinal metastases.


Assuntos
Neoplasias do Sistema Nervoso Central , Fusão Vertebral , Neoplasias da Coluna Vertebral , Humanos , Vértebras Lombares , Estudos de Coortes , Estudos Retrospectivos , Resultado do Tratamento
5.
J Arthroplasty ; 39(4): 1007-1012, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37852443

RESUMO

BACKGROUND: Although the modular sleeve concept for femoral implants has several advantages, studies reporting on greater than 20-year outcomes are limited. This study aimed to report the mean 23-year results of total hip arthroplasty (THA) using a modular stem with metaphyseal fixation sleeve. METHODS: This study reviewed primary THAs performed using a modular stem between October 1994 and April 1998. Of the 272 hips (221 patients) identified, 220 hips (177 patients) satisfying the minimum 20-year follow-up were included. The Harris Hip Score was used for clinical evaluation. Final hip radiographs were analyzed to evaluate the implant stability and the extent of femoral osteolysis. The mean follow-up duration was 23 years (range, 20 to 28). RESULTS: The mean Harris Hip Score improved from 38 points (range, 26 to 67) preoperatively to 90 points (range, 71 to 100) at the final follow-up (P < .001). Femoral osteolysis was observed in 146 hips (67.1%), but 145 were located proximal to the osseo-integrated sleeve. Overall, 4 femoral revisions were performed; 2 for chronic infection, one for aseptic loosening, and one for periprosthetic femoral fracture. Of the 19 (8.6%) periprosthetic femoral fractures, the most common type was Vancouver AG (13 hips). One (0.5%) asymptomatic distal stem fracture occurred, while no complications were identified at the stem-sleeve junction. Implant survivorship free of any femoral revision was 98.3% at 23 years. CONCLUSIONS: A THA using a modular stem with metaphyseal fixation sleeve demonstrated 98.3% stem survivorship with excellent clinical outcomes at a mean follow-up of 23 years in non-obese patients.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Osteólise , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Osteólise/cirurgia , Seguimentos , Reoperação/efeitos adversos , Falha de Prótese , Desenho de Prótese , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fraturas do Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
6.
PLoS One ; 18(10): e0287595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37903104

RESUMO

BACKGROUND: Small circular staplers possess the advantage of being relatively easy to use when compared to larger circular staplers. However, there is some contention as to whether the use of small circular staples in colorectal surgery increases the incidence of anastomotic strictures. This study aimed to determine whether the frequency of anastomosis site stricture formation differs depending on stapler size when performing anastomosis in colorectal surgery. METHODS: Patients who underwent surgery for colon or rectal disease between June 1, 2009, and December 31, 2021, and who had circular staplers used for the formation of intestinal anastomoses post colectomy were included in our study. Propensity score matching with a 1:1 ratio using logistic regression was performed. The primary outcome was the anastomotic stricture rate, and the secondary outcome was total anastomotic complications. RESULTS: A total of 875 patients who were operated on by surgeons using 28/29-mm and 25-mm circular staplers were included. After propensity score matching, 106 patients were assigned to each group. Anastomotic strictures occurred in two cases (1.9%) from the 25-mm group and in four cases (3.8%) from the 28/29-mm group. There were no statistically significant differences between the two groups (p = 0.683). Anastomotic complications were observed in two cases (1.9%) from the 25-mm group and in six cases (5.7%) from the 28/29-mm group; no statistically significant differences were found (p = 0.280). CONCLUSION: Circular stapler size does not influence anastomotic stricture formation in colorectal surgery.


Assuntos
Cirurgia Colorretal , Humanos , Constrição Patológica/etiologia , Constrição Patológica/epidemiologia , Pontuação de Propensão , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/etiologia , Estudos Retrospectivos
7.
World J Emerg Surg ; 18(1): 39, 2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37386447

RESUMO

BACKGROUND: Polymeric clips are easy to apply, but whether they present more advantages than endoloops is unclear. This single-center, open-label, randomized controlled trial study was conducted to compare the advantages of using a polymeric clip versus an endoloop in terms of the surgical time. METHODS: Adult patients who were diagnosed with acute appendicitis without perforation on preoperative abdominal computed tomography and underwent laparoscopic appendectomy between August 6, 2019, and December 26, 2022, were included. Single-blinded randomization was performed in a 1:1 ratio between the endoloop and polymeric clip groups. The primary endpoint was the difference in surgery time between the polymeric clip and endoloop groups. The secondary endpoints were the difference in the application time of each instrument, difference in operation and anesthesia fees, as well as the frequency of complications. RESULTS: The completed trial included 104 and 103 patients in the polymeric clip and endoloop groups, respectively. The median surgery time with a polymeric clip was shorter than that with an endoloop; however, the difference was not significant (18 min 56 s vs 19 min 49 s, p = 0.426). Interestingly, the median time from applying the instrument to appendiceal cutting in the polymeric clip group was significantly shorter than that in the endoloop group (49.0 s vs 84.5 s, p < 0.001). No significant difference was observed between the two groups in terms of surgical (p = 0.120) and anesthetic (p = 0.719) costs, as well as the total number of postoperative complications (p > 0.999). CONCLUSION: A polymeric clip is a safe instrument that can reduce the time from applying the instrument to appendiceal cutting, although it does not affect the overall surgical time and operation fee when performing laparoscopic appendectomy for uncomplicated appendicitis. TRIAL REGISTRATION: KCT0004154.


Assuntos
Apendicectomia , Apendicite , Laparoscopia , Adulto , Humanos , Apendicite/cirurgia , Projetos de Pesquisa , Instrumentos Cirúrgicos
8.
J Arthroplasty ; 38(11): 2379-2385, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37271230

RESUMO

BACKGROUND: Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS: A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS: The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION: Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fêmur/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Fatores de Risco
9.
Food Sci Biotechnol ; 32(5): 639-645, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37009037

RESUMO

Horse oil-in-water (O/W) emulsions were prepared and α-tocopherol was added at 0, 100, 200, and 500 ppm (α-T0, α-T100, α-T200, α-T500) to enhance its oxidative stability. Mean particle diameters of the O/W emulsions were 243-299 nm. Zeta potential values increased with the addition of α-tocopherol; however, they decreased during storage at 40 °C for 30 days. Particle size distribution of the O/W emulsion with α-tocopherol remained the same as that of α-T0. For lipid oxidation, the peroxide values of α-T0 and α-T500 were greatly increased from 2.96 and 2.89 to 13.76 and 12.46 mmol/kg oil, respectively, after 30 days. The α-T100 and α-T200 maintained lower peroxide values than other emulsions. Thiobarbituric acid-reactive substance values of α-T0 and α-T500 were higher than those of α-T100 and α-T200. These results indicate that the addition of α-tocopherol from 100 to 200 ppm to the horse oil-in-water emulsion effectively improves its oxidative stability during storage.

10.
Clin Neurol Neurosurg ; 227: 107668, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36924696

RESUMO

STUDY DESIGN: Retrospective Cohort Study OBJECTIVE: Myelopathy following ossification of the posterior longitudinal ligament (OPLL) is one of the devastating clinical features in these patients, while we still know little about which factors are associated with development of myelopathy. We evaluated the difference of radiologic measurements between OPLL patients with or without myelopathy and searched for the clinical significance with emphasis on the impact of dynamic motion. METHODS: 305 patients diagnosed of OPLL were enrolled for retrospective review. They were divided into two groups according to the coexistence of radiographic evidence of myelopathy. Demographic data as well as radiologic measures including the presence of disc degeneration (DD), anterior-posterior diameter (APD) of central canal, canal compromise (CC) ratio, global and segmental range of motion (gROM and sROM), OPLL type (morphologic classification) and K-line were collected. RESULTS: APD (odds ratio (OR); 0.411), CC ratio (OR; 1.100) and sROM (OR; 1.371) were significantly associated with the presence of myelopathy in the multivariate analysis. While the statistically significant factors were same in OPLLs with CC larger than 50%, presence of DD (OR; 4.509) and sROM (OR; 1.295) were significantly associated with myelopathy but not the CC itself in OPLLs with CC smaller than 50%. CONCLUSIONS: We discovered that the APD, CC ratio and sROM had significant association with development of myelopathy in OPLLs. And the presence of dynamic factors had significant association with myelopathy in OPLLs with smaller CC ratios. This observation and its clinical significance on development of myelopathy might enhance our understanding of OPLL.


Assuntos
Ossificação do Ligamento Longitudinal Posterior , Doenças da Medula Espinal , Humanos , Ligamentos Longitudinais , Estudos Retrospectivos , Osteogênese , Resultado do Tratamento , Doenças da Medula Espinal/etiologia , Doenças da Medula Espinal/complicações , Ossificação do Ligamento Longitudinal Posterior/complicações , Ossificação do Ligamento Longitudinal Posterior/diagnóstico por imagem , Fatores de Risco , Vértebras Cervicais/diagnóstico por imagem
11.
J Arthroplasty ; 38(7): 1335-1341, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36709880

RESUMO

BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Polietileno , Osteólise/etiologia , Osteólise/cirurgia , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
12.
J Infect Public Health ; 16(3): 354-360, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36682101

RESUMO

BACKGROUND: Perioperative prophylactic antibiotic (PPA) use in spine surgery is known to reduce the rate of surgical site infections. In the past decade, several evidence-based guidelines have been published and surveillance systems to monitor the proper use of antimicrobials had been adapted by many institutes. OBJECTIVE: To report the trends of PPA prescription in lumbar fusion surgeries nationwide in the Republic of Korea. METHODS: This is a nationwide registry study. Using the population-based data from the Republic of Korea provided by the Korean Health Insurance Review and Assessment Service, data of all lumbar spinal fusion surgeries performed between 2010 and 2018 in adult patients (age ≥19 years) were reviewed. RESULTS: The most frequently used antibiotics were first-generation cephalosporins, which accounted for 38.2 % of total PPA prescriptions and were prescribed in 58.96 % of lumbar fusion surgeries. A gradual increase in prescription trends was observed. The second most frequently used PPAs were second-generation cephalosporins, which showed decrease in use from 2016. The frequency of vancomycin prescriptions gradually increased over the observation period and showed an almost four-fold increase in 2018 compared to 2010. First- and second-generation cephalosporins were prescribed less frequently to patients with renal disease. CONCLUSION: The pattern of PPA use has changed remarkably over the observation period. Furthermore, specific differences in PPA prescriptions were observed among patients with certain co-morbidities.


Assuntos
Fusão Vertebral , Adulto , Humanos , Adulto Jovem , Fusão Vertebral/efeitos adversos , Estudos de Coortes , Antibacterianos/uso terapêutico , Vancomicina , Cefalosporinas/uso terapêutico , Estudos Retrospectivos
13.
Ann Coloproctol ; 39(2): 175-177, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34311544

RESUMO

Metachronous carcinoma at the colostomy site is very rare after abdominoperineal resection. A 53-year-old male patient underwent an abdominoperineal resection 6 years earlier for rectal cancer developed metachronous carcinoma at the site of stoma. A portion of the colon, including the stoma and the surrounding skin, was resected and a new stoma was created in the transverse colon. Although the occurrence of carcinoma at the stoma site is a rare condition, careful observation for the stoma and colonoscopy for surveillance are necessary.

14.
PLoS One ; 17(10): e0275239, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36269774

RESUMO

OBJECTIVE: We developed a novel multi-torsional mechanical stretch stress loading device for ligamentum flavum cells and evaluated its influence on the development of ligamentum flavum hypertrophy, a common cause of lumbar spinal canal stenosis. MATERIALS AND METHODS: Stretch strength of the device was optimized by applying 5% and 15% MSS loads for 24, 48, and 72 h. A cytotoxicity assay of human ligamentum flavum cells was performed and the results were compared to control (0% stress). Inflammatory markers (interleukin [IL]-6, IL-8), vascular endothelial growth factor [VEGF], and extracellular matrix (ECM)-regulating cytokines (matrix metalloproteinase [MMP]-1, MMP-3 and MMP-9, and tissue inhibitor of metalloproteinase [TIMP]-1 and TIMP-2) were quantified via enzyme-linked immunosorbent assay. RESULTS: Using our multi-torsional mechanical stretch stress loading device, 5% stress for 24 hour was optimal for ligamentum flavum cells. Under this condition, the IL-6 and IL-8 levels, VEGF level, and MMP-1, MMP-3, and TIMP-2 were significantly increased, compared to the control. CONCLUSION: Using the novel multi-torsional mechanical stretch stress loading device we confirmed that, mechanical stress enhances the production of inflammatory cytokines and angiogenic factors, and altered the expression of ECM-regulating enzymes, possibly triggering ligamentum flavum hypertrophy.


Assuntos
Ligamento Amarelo , Estenose Espinal , Humanos , Ligamento Amarelo/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Inibidor Tecidual de Metaloproteinase-2/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Metaloproteinase 3 da Matriz/metabolismo , Metaloproteinase 1 da Matriz/metabolismo , Estresse Mecânico , Interleucina-6/metabolismo , Interleucina-8/metabolismo , Estenose Espinal/etiologia , Hipertrofia/metabolismo , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Citocinas/metabolismo , Vértebras Lombares/metabolismo
15.
Medicine (Baltimore) ; 101(35): e30162, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36107522

RESUMO

A mesh is usually employed to cover defects when performing laparoscopic totally extraperitoneal repair (TEP) of inguinal hernias. However, there is insufficient evidence for an appropriate mesh size. Therefore, we aimed to compare the recurrence rate between large- and medium-mesh laparoscopic TEP. Patients who underwent laparoscopic TEP for primary inguinal hernias from January 2012 to March 2020 were included. We retrospectively reviewed electric medical records. The primary outcome was the difference in recurrence rate between the large and medium meshes. The large mesh was 10.3 × 15.7 cm, and the medium mesh was 7.9 × 13.4 cm or 9 × 13 cm. In total, 446 patients were included in the study. Of these patients, 177 were in the large-mesh group, and 269 were in the medium-mesh group. The average ages of the large- and medium-mesh groups were 58.4 and 56.9 years, respectively (P = .361). In both groups (large vs medium), males were dominant (93.2% vs 93.6%, P = .850), and indirect hernias (87.0% vs 88.1%, P = .740) were dominant. There was no difference in body mass index (P = .883) or hernia side (P = .770). Peritoneal tearing as an intraoperative complication occurred frequently in the large-mesh group (13.6% vs 3.3%, P < .001). During the mean follow-up period of 28 months, recurrence occurred in 3 (1.7%) and 13 (4.8%) patients in the large- and medium-mesh groups, respectively. However, there was no statistical significance (P = .262). Mesh size may not affect recurrence after laparoscopic TEP of primary inguinal hernias.


Assuntos
Hérnia Inguinal , Laparoscopia , Hérnia Inguinal/cirurgia , Humanos , Masculino , Próteses e Implantes , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos
16.
Neurosci Lett ; 786: 136813, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-35878655

RESUMO

Alcohol and nicotine are routinely abused together. There is one plausible explanation that comorbidity can alleviate alcohol-induced cognitive impairment. However, the mechanism involved is not known. The aim of this report was to evaluate the interactive effects of alcohol coadministration with nicotine on hippocampal memory and long-term potentiation (LTP). C57BL/6 mice were distributed into 4 treatment groups: control, alcohol, nicotine, and alcohol plus nicotine. All mice received tap water or alcohol solution and saline or nicotine. In water maze test, the alcohol group showed significant decreases in hippocampus function and acquisition training than control, nicotine, and combined treatment groups. The alcohol group also showed a significantly shorter latency in entering the foot-shock compartment than control, nicotine, and combined treatment groups in a passive avoidance test. Theta burst stimulation was adopted to induce concrete LTP in CA1 field recording using hippocampal slice. Alcohol alone administration failed to maintain LTP. Nicotine alone administration did not alter hippocampal LTP. There were no negative effects of alcohol on hippocampal LTP in mice administrated with nicotine. The current study successfully demonstrated beneficial effects of nicotine on alcohol induced memory impairment accompanied by hippocampal LTP impairment after one week of co-administration and one-day withdrawal.


Assuntos
Potenciação de Longa Duração , Nicotina , Animais , Região CA1 Hipocampal , Hipocampo , Potenciação de Longa Duração/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Nicotina/farmacologia
17.
J Arthroplasty ; 37(12): 2420-2426, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35753649

RESUMO

BACKGROUND: Tapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem. METHODS: Between December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years. RESULTS: The mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision. CONCLUSION: A tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Desenho de Prótese , Seguimentos , Reoperação , Fêmur/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Falha de Prótese
18.
Neurosurgery ; 91(2): 331-338, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35506942

RESUMO

BACKGROUND: Sagittal spinopelvic alignment (SSPA) parameters are essential for the diagnosis of adult spinal deformities (ASDs) and their progression. Certain clinical symptoms that occur in patients with lumbar spinal stenosis (LSS) and herniated nucleus pulposus (HNP) may distort the SSPA and mimic ASD. OBJECTIVE: To differentiate SSPA in symptomatic patients from asymptomatic patients within 10 minutes in the standing position. METHODS: This retrospective cohort study evaluated changes in SSPA after simple lumbar decompression surgery in patients with LSS and HNP. Relative sagittal alignment (RSA), relative pelvic version, relative lumbar lordosis (RLL), Lordosis Distribution Index (LDI), and global alignment and proportion (GAP) values were calculated using the conventional Schwab classification method. First, the preoperative and postoperative SSPA parameters were compared. Second, patients were subgrouped into symptomatic within 10 minutes of standing (SP group) and other symptoms of LSS and HNP as controls. Changes in SSPA parameters after symptom relief after simple lumbar decompression surgery were compared between the two groups. RESULTS: Overall, all SSPA parameters improved after surgery. However, after subgrouping, patients in the control group did not show significant SSPA alterations, except for LDI, whereas patients in the SP group significantly improved in terms of their RSA, RLL, LDI, and GAP values after symptom relief after surgery. CONCLUSION: Patients with pain on standing within 10 minutes showed significant correction in RSA, RLL, and GAP values after simple lumbar decompression. Therefore, it is important to observe such clinical symptoms to avoid misdiagnosis of ASD.


Assuntos
Lordose , Estenose Espinal , Adulto , Descompressão , Humanos , Lordose/diagnóstico por imagem , Lordose/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Estenose Espinal/cirurgia
19.
J Korean Med Sci ; 37(21): e173, 2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35638199

RESUMO

Owing to in-hospital transmission of coronavirus disease 2019 (COVID-19), Uijeongbu St. Mary's Hospital, a university-affiliated hospital in South Korea, was temporarily closed for disinfection in March 2020. This study aimed to investigate the impact of both the hospital shutdown and the prolonged COVID-19 pandemic on short-term outcomes of colorectal cancer (CRC) patients. We retrospectively reviewed the clinicopathologic data of 607 patients who were surgically treated for CRC from May 2018 to September 2021. Nodal upstaging, higher lymphatic invasion and abdominoperineal resection rates for 3 months after the hospital resumed surgery following the shutdown in the first wave of the COVID-19 pandemic were detected, without worse short-term morbidity or mortality. The incidence of adverse pathologic features of CRC such as lymphatic, venous, and perineural invasion was higher throughout the COVID-19 pandemic era. Further follow-up of CRC patients treated in the pandemic era for long-term oncologic outcomes is needed.


Assuntos
COVID-19 , Neoplasias Colorretais , Hospitais Universitários , Humanos , Pandemias , Estudos Retrospectivos , Resultado do Tratamento , Universidades
20.
PLoS One ; 17(3): e0264513, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35344540

RESUMO

BACKGROUND: Minimally invasive surgery is commonly used to treat patients with colorectal cancer, although it can cause surgical site infections (SSIs) that can affect the oncologic outcome. Use of a gentamicin-collagen sponge may help reduce the occurrence of SSIs. We aimed to determine the effectiveness of a gentamicin-collagen sponge in reducing SSIs in minimally invasive surgery for colorectal cancer. METHODS: We retrospectively reviewed the records of 310 patients who were diagnosed with colorectal cancer at our hospital and underwent minimally invasive surgery between December 1, 2018, and February 28, 2021. Propensity score matching was conducted with a 1:1 ratio using logistic regression. The primary outcome was the incidence of SSIs in the mini-laparotomy wound. The secondary endpoints were factors affecting the incidence of SSIs. RESULTS: After propensity score matching, 130 patients were assigned to each group. There were no differences in clinical characteristics between the two groups. SSIs occurred in 2 (1.5%) and 3 (2.3%) patients in the gentamicin-collagen sponge and control groups, respectively (p<0.999). The following factors showed a statistically significant association with SSIs: body mass index >25 kg/m2 (odds ratio, 39.0; 95% confidence interval, 1.90-802.21; p = 0.018), liver disease (odds ratio, 254.8; 95% confidence interval, 10.43-6222.61; p = 0.001), and right hemicolectomy (odds ratio, 36.22; 95% confidence interval, 2.37-554.63; p = 0.010). CONCLUSION: Applying a gentamicin-collagen sponge to the mini-laparotomy wound did not reduce the frequency of SSIs. Further studies should be conducted on whether the selective use of gentamicin-collagen sponges may help reduce SSIs in high-risk patients.


Assuntos
Neoplasias Colorretais , Gentamicinas , Antibacterianos/uso terapêutico , Colectomia/efeitos adversos , Colágeno/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/cirurgia , Gentamicinas/uso terapêutico , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA