Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37526665

RESUMO

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Íleo/diagnóstico por imagem , Íleo/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
2.
BJR Case Rep ; 9(6): 20220089, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37928705

RESUMO

Phaeochromocytomas (PCC) and paragangliomas (PGL), cumulatively referred to as PPGLs, are neuroendocrine tumours arising from neural crest-derived cells in the sympathetic and parasympathetic nervous systems. Predicting future tumour behaviour and the likelihood of metastatic disease remains problematic as genotype-phenotype correlations are limited, the disease has variable penetrance and, to date, no reliable molecular, cellular or histological markers have emerged. Tumour metabolism quantification can be considered as a method to delineating tumour aggressiveness by utilising hyperpolarised 13 C-MR (HP-MR). The technique may provide an opportunity to non-invasively characterise disease behaviour. Here, we present the first instance of the analysis of PPGL metabolism via HP-MR in a single case.

3.
J Magn Reson Imaging ; 57(6): 1865-1875, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36315000

RESUMO

BACKGROUND: Three-dimensional (3D) multiecho balanced steady-state free precession (ME-bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) 13 C-MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa). PURPOSE: To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME-bSSFP for HP 13 C-MRI in patients. To evaluate the metabolism in PCa measured by ME-bSSFP. STUDY TYPE: Retrospective single-center cohort study. PHANTOMS/POPULATION: Phantoms containing aqueous solutions of [1-13 C] lactate (2.3 M) and [13 C] urea (8 M). Eight patients (mean age 67 ± 6 years) with biopsy-confirmed Gleason 3 + 4 (n = 7) and 4 + 3 (n = 1) PCa. FIELD STRENGTH/SEQUENCES: 1 H MRI at 3 T with T2 -weighted turbo spin-echo sequence used for spatial localization and spoiled dual gradient-echo sequence used for B0 -field measurement. ME-bSSFP sequence for 13 C MR spectroscopic imaging with retrospective multipoint IDEAL metabolite separation. ASSESSMENT: The primary endpoint was the analysis of pyruvate-to-lactate conversion in PCa and healthy prostate regions of interest (ROIs) using model-free area under the curve (AUC) ratios and a one-directional kinetic model (kP ). The secondary objectives were to investigate the correlation between simulated and experimental ME-bSSFP metabolite signals for HP 13 C-MRI parameter optimization. STATISTICAL TESTS: Pearson correlation coefficients with 95% confidence intervals and paired t-tests. The level of statistical significance was set at P < 0.05. RESULTS: Strong correlations between simulated and empirical ME-bSSFP signals were found (r > 0.96). Therefore, the simulation framework was used for sequence optimization. Whole prostate metabolic HP 13 C-MRI, observing the conversion of pyruvate into lactate, with a temporal resolution of 6 seconds was demonstrated using ME-bSSFP. Both assessed metrics resulted in significant differences between PCa (mean ± SD) (AUC = 0.33 ± 012, kP  = 0.038 ± 0.014) and healthy (AUC = 0.15 ± 0.10, kP  = 0.011 ± 0.007) ROIs. DATA CONCLUSION: Metabolic HP 13 C-MRI in the prostate using ME-bSSFP allows for differentiation between aggressive PCa and healthy tissue. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Próstata , Ácido Pirúvico , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Ácido Pirúvico/química , Ácido Pirúvico/metabolismo , Estudos Retrospectivos , Estudos de Coortes , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ácido Láctico
4.
J Crohns Colitis ; 16(10): 1531-1539, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35481898

RESUMO

BACKGROUND AND AIMS: The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial. METHODS: A subset of participants [newly diagnosed or suspected of relapse] recruited to the METRIC trial with available terminal ileal [TI] biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London, and 'extended' London scores for active and severe [sMARIA] TI CD were calculated using different thresholds for the histological activity index [HAI]. RESULTS: We studied 111 patients [median age 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse] from seven centres, of whom 22 had no active TI CD [HAI = 0], 39 mild [HAI = 1], 13 moderate [HAI = 2], and 37 severe CD activity [HAI = 3]. In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease [HAI >0] were 83% [95% confidence interval 74% to 90%] and 41% [23% to 61%] for sMARIA, 76% [67% to 84%] and 64% [43% to 80%] for the London score, and 81% [72% to 88%] and 41% [23% to 61%] for the 'extended' London score, respectively. The sMARIA had 84% [69-92%] sensitivity and 53% [41-64%] specificity for severe CD. CONCLUSIONS: When tested at their proposed cut-offs in a real-world setting, sMARIA, London, and 'extended' London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética , Recidiva , Padrões de Referência , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA