Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
Br J Radiol ; 84(1004): 698-708, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21750137

RESUMO

OBJECTIVES: The aim of this study was to compare the intraindividual effects of contrast material with two different iodine concentrations on the conspicuity of hepatocellular carcinoma (HCC) and vascular and hepatic contrast enhancement during multiphasic, 64-section multidetector row CT (MDCT) in patients with cirrhosis using two contrast medium injection techniques. METHODS: Patients were randomly assigned to one of two groups with an equal iodine dose but different contrast material injection techniques: scheme A, fixed injection duration (25 s), and scheme B, fixed injection flow rate (4 ml s(-1)). For each group, patients were randomised to receive both moderate-concentration contrast medium (MCCM) and high-concentration contrast medium (HCCM) during two CT examinations within 3 months. Enhancement of the aorta, liver and portal vein and the tumour-to-liver contrast-to-noise ratio (CNR) were compared between MCCM and HCCM. RESULTS: 30 patients (mean age 59 years; range 45-80 years; 16 patients in scheme A and 14 in scheme B) with a total of 31 confirmed HCC nodules were prospectively enrolled. For scheme B, the mean contrast enhancement of the aorta and tumour-to-liver CNR were significantly higher with HCCM than with MCCM during the hepatic arterial phase (+350.5 HU vs +301.1 HU, p = 0.001, and +7.5 HU vs +5.5 HU, p = 0.004). For both groups, there was no significant difference between MCCM and HCCM for all other comparisons. CONCLUSION: For a constant injection flow rate, HCCM significantly improves the conspicuity of HCC lesions and aortic enhancement during the hepatic arterial phase on 64-section MDCT in patients with cirrhosis.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Iodo , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/irrigação sanguínea , Meios de Contraste/administração & dosagem , Meios de Contraste/química , Estudos Cross-Over , Humanos , Injeções Intravenosas , Iodo/administração & dosagem , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/instrumentação
2.
Br J Radiol ; 84(1004): 677-90, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21586504

RESUMO

Small bowel neoplasms, including adenocarcinoma, carcinoid tumour, lymphoma and gastrointestinal stromal tumours, represent a small percentage of gastrointestinal cancers, yet are among those with the poorest prognosis compared with other gastrointestinal malignancies. Unclear clinical scenarios and difficult radiological diagnosis often delay treatment with negative effects on patient survival. Recently, multidetector CT (MDCT) and MRI have been introduced as feasible and accurate diagnostic techniques for the identification and staging of small bowel neoplasms. These techniques are gradually replacing conventional barium radiography as the tool of choice. However, the inherent technical and physiological challenges of small bowel imaging require a familiarity with patient preparation and scan protocols. Adequate knowledge of the histopathology and natural evolution of small bowel neoplasms is also important for differential diagnosis. The aim of this article is to review MDCT and MRI protocols for the evaluation of small bowel tumours and to provide a concise yet comprehensive guide to the most relevant imaging features relative to histopathology.


Assuntos
Adenocarcinoma/diagnóstico , Tumor Carcinoide/diagnóstico , Neoplasias Intestinais/diagnóstico , Intestino Delgado/patologia , Linfoma não Hodgkin/diagnóstico , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Tumor Carcinoide/diagnóstico por imagem , Tumor Carcinoide/patologia , Protocolos Clínicos , Meios de Contraste , Feminino , Humanos , Neoplasias Intestinais/diagnóstico por imagem , Neoplasias Intestinais/patologia , Intestino Delgado/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Prognóstico , Tomografia Computadorizada por Raios X/métodos
3.
Radiol Med ; 116(6): 842-57, 2011 Sep.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-21509557

RESUMO

PURPOSE: This study was done to assess the diagnostic potential of dual-source computed tomography (DSCT) in the functional evaluation of lung cancer patients undergoing surgical resection. The CT data were compared with pulmonary perfusion scintigraphy and pulmonary function tests (PFTs). MATERIALS AND METHODS: All patients were evaluated with DSCT, scintigraphy and PFTs. The DSCT scan protocol was as follows: two tubes (80 and 140 kV; Care Dose protocol); 70 cc of contrast material (5 cc/s); 5- to 6-s scan time; 0.6 mm collimation. After the automatic calculation of lung perfusion with DSCT and quantification of air volumes and emphysema with dedicated software applications, the perfusional CT studies were compared with scintigraphy using a visual score for perfusion defects; CT air volumes and emphysema were compared with PFTs. RESULTS: The values of accuracy, sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of DSCT compared with perfusion scintigraphy as the reference standard were: 0.88, 0.84, 0.90, 0.93 and 0.88, respectively. The McNemar test did not identify significant differences either between the two imaging techniques (p=0.07) or between CT and PFTs (p=0.09). CONCLUSIONS: DSCT is a robust and promising technique that provides important and accurate information on lung function.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Cintilografia , Testes de Função Respiratória , Sensibilidade e Especificidade
4.
Radiol Med ; 116(6): 886-904, 2011 Sep.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-21293943

RESUMO

PURPOSE: This study prospectively assessed second-look ultrasound (US) for the evaluation of incidental enhancing lesions identified on preoperative breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: Between 2004 and 2007, 182 patients with malignant breast lesions detected on US and/or X-ray mammography and confirmed by cytology/histology underwent preoperative breast contrast-enhanced (CE)-MRI. Patients with incidental lesions on breast MRI underwent second-look high-resolution US directed at the site of the incidental finding. Diagnosis of incidental lesions was based on biopsy or 24-month follow-up. RESULTS: Breast MRI detected 55 additional lesions in 46/182 (25.2%) patients. Forty-two of 55 (76.3%) lesions were detected on second-look US in 38/46 (82.6%) patients. Malignancy was confirmed for 24/42 (57.1%) correlate lesions compared with 7/13 (53.8%) noncorrelate lesions. Second-look US depicted 8/9 (88.8%) Breast Imaging Reporting and Data System (BI-RADS) 5, 16/22 (72.7%) BI-RADS 4 and 18/24 (75%) BI-RADS 3 lesions. Sensitivity, specificity, accuracy and positive and negative predictive values for lesion detection/diagnosis was 100%, 88.9%, 94.6%, 90.3% and 100% for MRI and 64.3%, 70.4%, 67.3%, 69.2% and 65.5% for second-look US. Improved performance for US was obtained when masslike lesions only were considered. CONCLUSIONS: Second-look US is a confirmatory method for incidental findings on breast MRI, particularly for mass-like lesions.


Assuntos
Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Mamária , Adulto , Idoso , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Achados Incidentais , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Compostos Organometálicos , Estudos Prospectivos , Sensibilidade e Especificidade
5.
Eur J Vasc Endovasc Surg ; 41(2): 186-92, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21095141

RESUMO

OBJECTIVES: To assess the accuracy of colour-Doppler ultrasound (CDUS), contrast-enhanced ultrasonography (CEUS), computed tomography angiography (CTA) and magnetic resonance angiography (MRA) in detecting endoleaks after endovascular abdominal aortic aneurysm repair (EVAR). DESIGN: Prospective, observational study. MATERIALS AND METHODS: From December 2007 to April 2009, 108 consecutive patients who underwent EVAR were evaluated with CDUS, CEUS, CTA and MRA as well as angiography, if further treatment was necessary. Sensitivity, specificity, accuracy and negative predictive value of ultrasound examinations were compared with CTA and MRA as the reference standards, or with angiography when available. RESULTS: Twenty-four endoleaks (22%, type II: 22 cases, type III: two cases) were documented. Sensitivity and specificity of CDUS, CEUS, CTA, and MRA were 58% and 93%, 96% and 100%, 83% and 100% and 96% and 100% respectively. CEUS allowed better classification of endoleaks in 10, two and one patients compared with CDUS, CTA and MRA, respectively. CONCLUSIONS: The accuracy of CEUS in detecting endoleaks after EVAR is markedly better than CDUS and is similar to CTA and MRA. CEUS seems to be a feasible tool in the long-term surveillance after EVAR, and it may better classify endoleaks missed by other imaging techniques.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Meios de Contraste , Endoleak/diagnóstico , Procedimentos Endovasculares/instrumentação , Angiografia por Ressonância Magnética , Falha de Prótese , Stents , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores , Idoso , Angiografia Digital , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sensibilidade e Especificidade , Fatores de Tempo
6.
Radiol Med ; 115(8): 1314-29, 2010 Dec.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-20852963

RESUMO

PURPOSE: The purpose of this study was to evaluate the role of magnetic resonance spectroscopic imaging (MRSI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in detecting tumour foci in patients with elevated prostate-specific antigen (PSA) and negative transrectal ultrasonography (TRUS)-guided biopsy. MATERIALS AND METHODS: This prospective randomised trial was conducted on 150 patients who underwent [¹H]MRSI and DCE-MRI and targeted biopsies of suspicious areas on MRI associated with random biopsies. RESULTS: After the second biopsy, the diagnosis of prostate adenocarcinoma was made in 64/150 cases. On a per-patient basis, MRSI had 82.8% sensitivity, 91.8% specificity, 88.3% positive predictive value (PPV), 87.8% negative predictive value (NPV) and 85.7% diagnostic accuracy. The sensitivity, specificity, PPV, NPV and accuracy for DCE-MRI was 76.5%, 89.5%, 84.5%, 83.7% and 82%, respectively. The combination of MRSI and DCE-MRI yielded 93.7% sensitivity, 90.7% specificity, 88.2% PPV, 95.1% NPV and 90.9% accuracy in detecting prostate carcinoma. CONCLUSIONS: The combined study with [¹H]MRSI and DCE-MRI showed promising results in guiding the biopsy of cancer foci in patients with an initial negative TRUS-guided biopsy.


Assuntos
Adenocarcinoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Idoso , Biópsia por Agulha , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Valor Preditivo dos Testes , Estudos Prospectivos , Antígeno Prostático Específico/análise , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia de Intervenção
7.
Clin Ter ; 161(2): e49-52, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20499019

RESUMO

OBJECTIVE: To evaluate whether pattern III of color Doppler Ultra-sound may identify malignant nodules. MATERIALS AND METHODS: We have retrospectively analyzed data pertaining to 1090 patients of both genders (230 males, 860 females), with an average age of 53 years (min 17 years, max 81 years), who underwent thyroidectomy in Department of Surgical Sciences of Sapienza University of Rome since January 2003 through June 2009. We correlated color-Doppler characteristics and histological features through statistical analysis so as to verify statistical correlation between them. RESULTS: Our study showed that 164/273 (60.1%) patients with malignant disease were associated with vascularization pattern III. Regarding benign disease, 152/268 (56.7%) patients showed a pattern of vascularization 3 at ultrasonography. The statistical analysis was not able to show any correlation between pattern III and malignancy. CONCLUSION: Pattern III cannot be used to predict malignancy with confidence, and FNA is still mandatory to rule out the nature of the nodule.


Assuntos
Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia Doppler em Cores , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Adulto Jovem
8.
Ultraschall Med ; 31(5): 500-5, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20408122

RESUMO

PURPOSE: To compare ultrasound (US), low-mechanical index contrast enhanced US (CEUS) and multidetector-CT (MDCT) for the detection of hepatic metastases from colorectal cancer. METHODS AND MATERIALS: From January to June 2006, 110 patients (65 males, 45 females; mean age 62 years; range 39-78) with suspected hepatic lesions from colorectal cancer were prospectively evaluated with US, CEUS and MDCT by two independent readers. Intraoperative ultrasonography (IOUS, n = 45) or a follow-up up for at least 6 months by using MDCT or Gd-BOPTA-enhanced MRI was considered the gold standard. McNemar test was employed. RESULTS: Reference standards revealed 430 metastases in 110 patients. On a patient-by-patients analysis, CEUS improved US sensitivity from 67.4-71.6% to 93.4-95.8% (p < 0.05). On a lesion-by-lesion analysis, CEUS improved the sensitivity of US from 60.9-64.9% to 85.3-92.8% (p < 0.001). The specificity increased from 50-60% to 76.7-83.3%. No significant differences in sensitivity or specificity between CEUS and MDCT were found. Contrast-enhanced US was significantly more sensitive than baseline US in the detection of metastases smaller than 1 cm (p < 0.001) with an increase in sensitivity from 29.1-35% to 63.3-76.6% no significant statistical difference was identified when compared with MDCT (sensitivity of 73.3-75.8%). CONCLUSIONS: CEUS is significantly more accurate than US and highly comparable with MDCT in the detection of liver metastases from colorectal cancer. Therefore, in the evaluation of patients with suspected hepatic metastases from colorectal tumour, US examination must be performed after contrast administration.


Assuntos
Neoplasias Colorretais/diagnóstico , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Fosfolipídeos , Hexafluoreto de Enxofre , Tomografia Computadorizada Espiral/métodos , Ultrassonografia/métodos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade
9.
Eur Arch Otorhinolaryngol ; 267(9): 1461-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20376470

RESUMO

With the advent of dynamic fast MRI sequences the act of deglutition can be dynamically visualized in cine-mode. Twenty-three healthy volunteers were enrolled in this study to define the morpho-functional patterns of oral and pharyngeal deglutition using new dynamic MRI techniques. All subjects were previously submitted to video endoscopic assessment, to exclude swallowing abnormalities. As contrast material a combination of yogurt mixed with gadolinium-diethylene diamine pentaacetic acid was used. The protocol was divided into three parts: (a) preliminary assessment of the oral cavity, pharynx and laryngeal structures; (b) morphologic assessment of tongue, soft palate, pharynx, epiglottis and larynx-hyoid bone; (c) dynamic assessment of swallowing without administrating any contrast media and, in subsequent phase, by injecting 5 ml of yogurt-based contrast medium in the patient's mouth. The time resolution was 3-4 images/s. The MR protocol revealed to be effective in the evaluation of normal motility patterns of the structures involved in swallowing. Moreover, the evaluation of the bolus progression, slowdown or stagnation, was possible. On the contrary problems were encountered in calculating precisely the bolus progression time, because of the insufficient temporal resolution. However, more energy should be invested to optimize the spatial and temporal resolution of turbo-FLASH sequences, to obtain a better dynamic representation of a complex function such as deglutition.


Assuntos
Deglutição/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Orofaringe/fisiologia , Meios de Contraste/administração & dosagem , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/fisiopatologia , Gadolínio DTPA , Humanos , Peristaltismo/fisiologia , Valores de Referência , Sensibilidade e Especificidade
11.
Radiol Med ; 115(5): 758-70, 2010 Aug.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-20174880

RESUMO

PURPOSE: The aim of this study was to assess the accuracy of translucency rendering (TR) in computed tomographic (CT) colonography without cathartic preparation using primary 3D reading. MATERIALS AND METHODS: From 350 patients with 482 endoscopically verified polyps, 50 pathologically proven polyps and 50 pseudopolyps were retrospectively examined. For faecal tagging, all patients ingested 140 ml of orally administered iodinated contrast agent (diatrizoate meglumine and diatrizoate sodium) at meals 48 h prior to CT colonography examination and two h prior to scanning. CT colonography was performed using a 64-section CT scanner. Colonoscopy with segmental unblinding was performed within 2 weeks after CT. Three independent radiologists retrospectively evaluated TRCT clonographic images using a dedicated software package (V3D-Colon System). To enable size-dependent statistical analysis, lesions were stratified into the following size categories: small (< or =5 mm), intermediate (6-9 mm), and large (> or =10 mm). RESULTS: Overall average TR sensitivity for polyp characterisation was 96.6%, and overall average specificity for pseudopolyp characterisation was 91.3%. Overall average diagnostic accuracy (area under the curve) of TR for characterising colonic lesions was 0.97. CONCLUSIONS: TR is an accurate tool that facilitates interpretation of images obtained with a primary 3D analysis, thus enabling easy differentiation of polyps from pseudopolyps.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Pólipos do Colo/patologia , Colonoscopia , Meios de Contraste , Diagnóstico Diferencial , Diatrizoato , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Software
12.
Radiol Med ; 115(3): 385-402, 2010 Apr.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-20077046

RESUMO

Computer-aided detection (CAD) systems allow the automatic identification of lung nodules on chest computed tomography (CT), providing a second opinion to the radiologist's judgement and a volumetric evaluation of lesions - a very important aspect in oncological patients. The natural evolution of these systems has led to the introduction of computer-aided diagnosis (CADx) systems, which are able not only to identify nodules but also to characterise them by determining a likelihood of malignancy or benignity. The aim of this article is to describe the main technical principles of CAD and CADx systems, their applicability and influence in clinical practice and new prospects for their future development.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Diagnóstico Diferencial , Humanos , Neoplasias Pulmonares/patologia
13.
Radiol Med ; 114(7): 1065-79, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19774440

RESUMO

PURPOSE: This study was undertaken to compare the accuracy of magnetic resonance (MR) imaging and 64-slice multidetector computed tomography (64-MDCT) in the T staging of gastric carcinoma in comparison with histopathology. MATERIALS AND METHODS: Forty patients with an endoscopic diagnosis of gastric carcinoma underwent preoperative MR imaging and 64-MDCT, both of which were performed after i.v. injection of scopolamine and water distension of the stomach. In the MR imaging protocol, we acquired T2-weighted turbo spin-echo (TSE) sequences, true fast imaging steady-state free precession (true-FISP) and gadolinium-enhanced T1-weighted volumetric interpolated breath-hold examination (VIBE) 3D sequences. Contrastenhanced CT scans were obtained in the arterial and venous phases. Two groups of radiologists independently reviewed the MR and 64-MDCT images. The results were compared with pathology findings. RESULTS: In the evaluation of T stage, 64-MDCT had 82.5% and MR imaging had 80% sensitivity. Accuracy of MR imaging was slightly higher than that of 64-MDCT in identifying T1 lesions (50% vs 37.5%), whereas the accuracy of 64-MDCT was higher in differentiating T2 lesions (81.2% vs 68.7%). The accuracy of MR imaging and 64-MDCT did not differ significantly in the evaluation of T3-T4 lesions (p>0.05). Understaging was observed in 20% of cases with MR imaging and in 17.5% with 64-MDCT. CONCLUSIONS: MR imaging and 64-MDCT accuracy levels did not differ in advanced stages of disease, whereas MR imaging was superior in identifying early stages of gastric cancer and can be considered a valid alternative to MDCT in clinical practice.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Tomografia Computadorizada por Raios X , Biópsia , Meios de Contraste , Feminino , Gastroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Radiol Med ; 114(4): 538-52, 2009 Jun.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-19430733

RESUMO

PURPOSE: This study was performed to validate a high-resolution whole-body magnetic resonance angiography (MRA) protocol with parallel imaging and biphasic administration of a single bolus of contrast agent in the preliminary assessment of systemic atherosclerotic burden in patients referred for endovascular procedures. MATERIALS AND METHODS: Forty patients referred for endovascular treatment of atherosclerotic disease of the carotid arteries (n=23), peripheral vessels (n=14) or aorta (n=3) on the basis of previous clinical and diagnostic examinations underwent high-resolution whole-body MRA at 1.5 T with 3D spoiled gradient recalled echo (GRE) sequences, featuring parallel imaging acquisition technique with x2 acceleration factor. Sixty-eight surface coil elements and a four-station imaging protocol were employed. Biphasic intravenous administration of a paramagnetic contrast agent [gadolinium benzyloxyproprionic-tetraacetic acid (Gd-BOPTA)] was performed with the following protocol: 10 ml at a speed of 1 ml/s followed by further 10 ml at a speed of 0.5 ml/s. For image analysis, the arterial system was divided into 42 segments for evaluation. The presence or absence of atherosclerotic lesions was evaluated by two observers in consensus; segments were classified as having clinically significant disease (>or=50% stenosis or an aneurysmal dilatation) or no significant disease (<50% stenosis). The presence of stenoocclusive disease, determined at all segments, was compared with findings on digital subtraction angiography (DSA), which were interpreted by a third independent reader. Sensitivity, specificity and concordance of whole-body MRA findings with DSA were calculated, and receiver operating characteristic (ROC) analysis was performed for all vascular territories. RESULTS: A total of 1,680 arterial segments was evaluated; 138 (8.3%) were affected by atherosclerotic alterations. Carotid lesions were confirmed in 23 patients (34 segments), involvement of peripheral vessels in 14 (57 segments) and abdominal aneurysms in three. Sensitivity and specificity of whole-body MRA were, respectively, 95%-97% for head and neck vessels, 100%-100% for thoracoabdominal vessels, 98%-97% for thigh vessels and 84%-88% for calf vessels; concordance with the DSA findings was significant (p<0.05). Subclinical atherosclerotic lesions were evidenced in 25 patients, involving carotid arteries (12 segments), peripheral vessels (21 segments) and abdominal aorta (one segment). All these lesions were confirmed by a second modality, and ten of these patients required further care. CONCLUSIONS: High-resolution whole-body MRA with Gd-BOPTA may be considered a reliable modality for imaging systemic atherosclerosis in candidates for endovascular procedures. The subclinical detection of the total atherosclerotic burden has potential implications for secondary care in this population.


Assuntos
Aterosclerose/diagnóstico , Meios de Contraste , Angiografia por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Procedimentos Cirúrgicos Vasculares , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/patologia , Arteriopatias Oclusivas/diagnóstico , Aterosclerose/cirurgia , Estenose das Carótidas/diagnóstico , Protocolos Clínicos , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/métodos
15.
Ultraschall Med ; 30(3): 252-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19280552

RESUMO

PURPOSE: The present study was conducted to assess the efficacy of contrast-enhanced ultrasound with low mechanical index in evaluating the response of percutaneous radiofrequency ablation treatment of hepatocellular carcinoma by comparing it with 4-row spiral computed tomography. MATERIALS AND METHODS: 100 consecutive patients (65 men and 35 women; age range: 62 - 76 years) with solitary hepatocellular carcinomas (mean lesion diameter: 3.7 cm +/- 1.1 cm SD) underwent internally cooled radiofrequency ablation. Therapeutic response was evaluated at one month after the treatment with triple-phasic contrast-enhanced spiral CT and low-mechanical index contrast-enhanced ultrasound following bolus injection of 2.4 ml of Sonovue (Bracco, Milan). 60 out of 100 patients were followed up for another 3 months. Contrast-enhanced sonographic studies were reviewed by two blinded radiologists in consensus. Sensitivity, specificity, NPV and PPV of contrast-enhanced ultrasound examination were determined. RESULTS: After treatment, contrast-enhanced ultrasound identified persistent signal enhancement in 24 patients (24 %), whereas no intratumoral enhancement was detected in the remaining 76 patients (76 %). Using CT imaging as gold standard, the sensitivity, specificity, NPV, and PPV of contrast enhanced ultrasound were 92.3 % (95 % CI = 75.9 - 97.9 %), 100 % (95 % CI = 95.2 - 100 %), 97.4 % (95 % CI = 91.1 - 99.3 %), and 100 % (95 % CI = 86.2 - 100 %). CONCLUSION: Contrast-enhanced ultrasound with low mechanical index using Sonovue is a feasible tool in evaluating the response of hepatocellular carcinoma to radiofrequency ablation. Accuracy is comparable to 4-row spiral CT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Fosfolipídeos , Hexafluoreto de Enxofre , Cirurgia Assistida por Computador , Tomografia Computadorizada Espiral , Ultrassonografia/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasia Residual/diagnóstico por imagem , Neoplasia Residual/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Reoperação
16.
Radiol Med ; 114(1): 52-69, 2009 Feb.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-19082785

RESUMO

PURPOSE: This study was conducted to evaluate the role of computed tomography cystography (CTC) and virtual cystoscopy (VC) with 64-slice CT in diagnosing bladder lesions using flexible cystoscopy as the reference standard. MATERIALS AND METHODS: Twenty-eight patients with suspected bladder cancer and ten patients who had undergone transurethral resection of the bladder were studied by CTC and VC in both the supine and prone positions after distending the bladder with air. The patient population was divided into three groups based on lesion size at flexible cystoscopy. Results of the CT study were compared with those of flexible cystoscopy. RESULTS: Flexible cystoscopy depicted 88 bladder lesions in the 38 patients examined. Sensitivity and specificity values of CTC and VC alone were constantly lower than those of the combined-approach (group 1: 93.10% and 92.31%; group 2: 100% and 100%; group 3: 100% and 100%, respectively). Receiver operating characteristic (ROC) curve analysis showed that the combined approach decreases the lower dimensional threshold for lesion detection (1.4 mm). CONCLUSIONS: VC and CTC with 64-slice CT are promising diagnostic techniques for bladder cancers measuring 1-5 mm. Further studies on larger patient populations are required to validate our results.


Assuntos
Carcinoma de Células de Transição/diagnóstico por imagem , Cistoscopia/métodos , Tomografia Computadorizada Espiral , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Idoso , Carcinoma de Células de Transição/patologia , Interpretação Estatística de Dados , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Variações Dependentes do Observador , Seleção de Pacientes , Decúbito Ventral , Curva ROC , Sensibilidade e Especificidade , Decúbito Dorsal , Fatores de Tempo , Tomografia Computadorizada Espiral/instrumentação , Tomografia Computadorizada Espiral/métodos , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/patologia
17.
Clin Radiol ; 63(5): 577-85, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18374723

RESUMO

Focal nodular hyperplasia is a benign hypervascular hepatic tumour, frequently detected in asymptomatic patients undergoing imaging studies for unrelated reasons. Magnetic resonance imaging (MRI) generally allows a confident differential diagnosis with other hypervascular liver lesions, either benign or malignant. In addition, due to the recent development of hepatospecific MRI contrast agents, MRI concomitantly enables functional and morphological information to be obtained, thus providing important clues for the detection and characterization of focal nodular hyperplasia lesions.


Assuntos
Meios de Contraste , Hiperplasia Nodular Focal do Fígado/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Diagnóstico Diferencial , Feminino , Gadolínio DTPA , Humanos , Compostos de Ferro , Neoplasias Hepáticas/diagnóstico , Meglumina/análogos & derivados , Compostos Organometálicos
18.
Radiol Med ; 112(1): 31-46, 2007 Feb.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-17310293

RESUMO

PURPOSE: We present our initial clinical experience with a recently introduced 64-detector computed tomography (64-MDCT) scanner that makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot), which enables it to reach a final spatial resolution of 0.4 x 0.4 x 0.4 mm(3) and a temporal resolution of 83 ms. MATERIALS AND METHODS: A total of 114 patients (108 men, six women; age range 36-77 years, mean 63.1 years) underwent retrospective electrocardiogram (ECG)-gated examination of the coronary arteries using a 64-MDCT scanner (Somatom Sensation 64, Siemens Medical Solutions, Germany). Acquisition parameters were the following: collimation 64 x 0.6 mm, 800 quality reference milliampere second (mAs), 120 kVp, 0.33-s gantry rotation time and pitch 0.2. Images were acquired in all cases after i.v. administration of 80 ml of contrast agent (Iomeron 400 mgI/dl, Bracco, Italy) + 30 ml of saline at 4 /s and delay time determined using a bolus triggering technique. Oral betablockers were administered to patients with heart rate (HR) >75 bpm. To reduce radiation exposure, an automatic exposure control system was applied in all cases to adapt tube current to patient size and anatomic shape (CARE Dose 4D, Siemens Medical Solutions, Germany). The optimal temporal window for raw data reconstruction was chosen from an initial preview of images reconstructed with different phase settings (range 0%-95% RR interval with 5% gap) at a selected anatomical level in the mid part of the right coronary artery. CT dose index volume and effective dose were quantified in all patients using dedicated software. RESULTS: Mean HR recorded during image acquisition was 65.6+/-19.2 bmp (range: 44-96 bmp), and beta-blockers were administered to 16/114 patients (14.0%). Technical adequacy was achieved in all patients but two (2/114; 1.7%). In patients with HR <60 bmp, the best reconstruction intervals were identified in the end-systolic (30%-35% of the RR interval) and end-diastolic (60%-65% of the RR interval) phases; with faster HR (>80 bmp), high image quality was observed in end-systole (30%-35% of the RR interval). Mean CT dose index (CTDI) volume was 36.53+/-8.30 mGy per patient. In comparison with a conventional examination with fixed mAs, the use of the CARE Dose 4D system provided a 33.3% CTDI volume reduction (p<0.001). Mean effective dose was 9.5+/-3.4 millisievert (mSv) per patient (range 7.1-17.7). CONCLUSIONS: The 64-MDCT scanner diagnostic performance for coronary CT angiography is further improved with better spatial and temporal resolution and faster scan times; besides, initial clinical results are promising. The use of dose-reducing acquisition techniques is mandatory to limit radiation exposure to the patient.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária , Eletrocardiografia , Feminino , Seguimentos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Injeções Intravenosas , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Stents , Fatores de Tempo , Grau de Desobstrução Vascular
19.
Ultraschall Med ; 28(1): 57-62, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17304413

RESUMO

PURPOSE: To assess the efficacy of low mechanical index (MI) real time grey scale contrast-enhanced US (CEUS) in the differentiation of breast lesions in comparison to Magnetic Resonance Imaging (MRI). MATERIALS AND METHODS: 50 lesions previously detected at mammography or conventional US were evaluated by means of CEUS and MRI. Contrast-enhanced examinations were performed with a dedicated equipment (Esatune, Esaote, Genoa, Italy), before and after injection of 4.8 ml of Sonovue (Bracco, Milan, Italy). MRI was conducted with a 1.5 T equipment (Siemens Vision Plus, Erlangen, Germany) with bilateral dedicated superficial coil, on T2w STIR and 3D Flash T1w before and 1, 2, 3, 4, 5 minutes after the administration of contrast agent (Gd-DTPA, 1.5 ml/kg). Wash-in and wash-out curves were assessed for both procedures. A specific sonographic quantification software (Qontrast, Bracco, Milan, Italy), based on pixel by pixel signal intensity over time, was used to obtain contrast-enhanced sonographic perfusion maps for each lesion. Mc Nemar test was then calculated. RESULTS: 24 invasive ductal carcinomas, 18 fibroadenomas, 4 fibro-cystic dysplasias, 1 mucinous carcinoma, 1 invasive ducto-lobular carcinoma, 1 intraductal florid papillomatosis and 1 phylloides tumour were diagnosed. Contrast-enhanced sonographic patterns correlated well with those provided by MRI. Sensitivity, specificity, and accuracy of US were: 69.2 %, 66.7 %, and 68 %, respectively. According to the different contrast enhancement patterns and the resulting perfusion maps, all the malignant lesions and 9 out of 12 benign lesions were correctly diagnosed, thus resulting in 87.5 % of specificity and 100 % of sensitivity. Regarding the specificity, there is no difference between US and CEUS with McNemar (p = 0.18). Regarding sensitivity, the difference between contrast-enhanced US and US is significant as calculated with McNemar test (p = 0.013). The three lesions which were incorrectly classified as malignant were two hypervascularised fibroadenomas in young women and a phylloides tumour. CONCLUSION: CEUS seems to be a reliable method to differentiate breast lesions, since it provides typical enhancement patterns. Contrast sonographic perfusion curves correlate well with MRI wash in--wash out curves.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama Masculina/diagnóstico , Neoplasias da Mama Masculina/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Feminino , Fibroadenoma/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA