Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 157(2): 467-476.e1, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30121136

RESUMO

OBJECTIVE: Four-dimensional flow cardiovascular magnetic resonance may improve assessment of hemodynamics in patients with aortic dissection. The purpose of this study was to evaluate the feasibility and accuracy of 4-dimensional flow cardiovascular magnetic resonance assessment of true and false lumens flow. METHODS: Thirteen ex vivo porcine aortic dissection models were mounted to a flow loop. Four-dimensional flow cardiovascular magnetic resonance and 2-dimensional phase-contrast cardiovascular magnetic resonance measurements were performed, assessed for intraobserver and interobserver variability, and compared with a reference standard of sonotransducer flow volume measurements. Intraobserver and interobserver variability of 4-dimensional flow cardiovascular magnetic resonance were also assessed in 14 patients with aortic dissection and compared with 2-dimensional phase-contrast cardiovascular magnetic resonance. RESULTS: In the ex vivo model, the intraobserver and interobserver measurements had Lin's correlation coefficients of 0.98 and 0.96 and mean differences of 0.17 (±3.65) mL/beat and -0.59 (±5.33) mL/beat, respectively; 4-dimensional and sonotransducer measurements had a Lin's concordance correlation coefficient of 0.95 with a mean difference of 0.35 (±4.92) mL/beat, respectively. In patients with aortic dissection, the intraobserver and interobserver measurements had Lin's concordance correlation coefficients of 0.98 and 0.97 and mean differences of -0.95 (±8.24) mL/beat and 0.62 (±10.05) mL/beat, respectively; 4-dimensional and 2-dimensional flow had a Lin's concordance correlation coefficient of 0.91 with a mean difference of -9.27 (±17.79) mL/beat because of consistently higher flow measured with 4-dimensional flow cardiovascular magnetic resonance in the ascending aorta. CONCLUSIONS: Four-dimensional flow cardiovascular magnetic resonance is feasible in patients with aortic dissection and can reliably assess flow in the true and false lumens of the aorta. This promotes potential future work on functional assessment of aortic dissection hemodynamics.


Assuntos
Aorta/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Dissecção Aórtica/fisiopatologia , Animais , Aorta/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Suínos
2.
J Card Surg ; 31(9): 581-3, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27455392

RESUMO

The application of three-dimensional (3D) printing enables the creation of material objects from digital images by depositing layers of plastic material into 3D structures and can be used for training, education, and surgical planning. We report two patients with large complex cardiac tumors where 3D technology was utilized to analyze the tumor size, location, and extension more precisely, allowing better preoperative planning and decision making.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/cirurgia , Imageamento Tridimensional/métodos , Modelos Anatômicos , Impressão Tridimensional , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Seguimentos , Neoplasias Cardíacas/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA