Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 50(9): 5817-5827, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37493525

RESUMO

BACKGROUND: The beam energy is one of the most significant parameters in particle therapy since it is directly correlated to the particles' penetration depth inside the patient. Nowadays, the range accuracy is guaranteed by offline routine quality control checks mainly performed with water phantoms, 2D detectors with PMMA wedges, or multi-layer ionization chambers. The latter feature low sensitivity, slow collection time, and response dependent on external parameters, which represent limiting factors for the quality controls of beams delivered with fast energy switching modalities, as foreseen in future treatments. In this context, a device based on solid-state detectors technology, able to perform a direct and absolute beam energy measurement, is proposed as a viable alternative for quality assurance measurements and beam commissioning, paving the way for online range monitoring and treatment verification. PURPOSE: This work follows the proof of concept of an energy monitoring system for clinical proton beams, based on Ultra Fast Silicon Detectors (featuring tenths of ps time resolution in 50 µm active thickness, and single particle detection capability) and time-of-flight techniques. An upgrade of such a system is presented here, together with the description of a dedicated self-calibration method, proving that this second prototype is able to assess the mean particles energy of a monoenergetic beam without any constraint on the beam temporal structure, neither any a priori knowledge of the beam energy for the calibration of the system. METHODS: A new detector geometry, consisting of sensors segmented in strips, has been designed and implemented in order to enhance the statistics of coincident protons, thus improving the accuracy of the measured time differences. The prototype was tested on the cyclotron proton beam of the Trento Protontherapy Center (TPC). In addition, a dedicated self-calibration method, exploiting the measurement of monoenergetic beams crossing the two telescope sensors for different flight distances, was introduced to remove the systematic uncertainties independently from any external reference. RESULTS: The novel calibration strategy was applied to the experimental data collected at TPC (Trento) and CNAO (Pavia). Deviations between measured and reference beam energies in the order of a few hundreds of keV with a maximum uncertainty of 0.5 MeV were found, in compliance with the clinically required water range accuracy of 1 mm. CONCLUSIONS: The presented version of the telescope system, minimally perturbative of the beam, relies on a few seconds of acquisition time to achieve the required clinical accuracy and therefore represents a feasible solution for beam commission, quality assurance checks, and online beam energy monitoring.


Assuntos
Terapia com Prótons , Calibragem , Terapia com Prótons/normas , Fatores de Tempo , Humanos
2.
Artigo em Inglês | MEDLINE | ID: mdl-34769732

RESUMO

In this paper, an in-depth and systematic study of the radiological characterization of three types of Puglia region natural limestones (Pietra Leccese, Pietra Mazzara and Carparo) was carried out. The investigation was performed by XRF spectroscopy for a chemical analysis, and gamma spectroscopy of the specific activity concentration of natural radionuclides 226Ra, 232Th, and 40K. Although the limestone does not fall within the category included by Italian Legislative Decree 101/2020, the gamma index was calculated using the results of the gamma spectroscopy measurements. For Pietra Mazzara and Carparo stones, the gamma index was found to be less than the reference value; conversely Pietra Leccese was found to be higher. To obtain a more complete evaluation of the external exposure, radium equivalent activity and external radiation hazard were calculated for all analyzed stones. The results suggest the need to broadly consider the radiological risk for these stones, and for limestone more generally, when used as a building material.


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Rádio (Elemento) , Radiação de Fundo , Materiais de Construção , Radioisótopos de Potássio/análise , Doses de Radiação , Rádio (Elemento)/análise , Espectrometria gama , Tório/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA