1.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943783

RESUMO

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Circ Cardiovasc Interv ; 11(12): e007220, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30562084

RESUMO

BACKGROUND: Although aortic valve replacement (AVR) can be lifesaving, many patients with symptomatic aortic stenosis do not undergo appropriate therapy. This study sought to examine the characteristics, outcomes, and reasons for not pursuing AVR in a contemporary cohort. METHODS AND RESULTS: We examined 548 patients with severe, symptomatic aortic stenosis not treated with AVR through March 2017. Patients were grouped according to AVR appropriateness based on the presence of medical futility. Demographics, rationale for no AVR therapy, and outcomes were assessed. There were 359 (65.5%) potentially appropriate candidates for AVR and 189 (34.5%) others patients with futility. Among potentially appropriate patients, 62.1% had severe symptoms, 74.4% had not been referred for AVR, and 40.1% were low risk. Patient refusal was common (54.6%), with incorrect symptom assignment or aortic stenosis severity classification accounting for nearly all other explanations. Compared with patients with futility, potentially appropriate AVR patients had lower rates of both referral to cardiology or surgery (85.2% versus 92.6%; P=0.01) and complete heart team evaluations (10.6% versus 17.5%; P=0.02). Palliative consultation occurred in only 124 patients (22.6%) overall and in only 10.0% of those without futility. Overall, the 1-year mortality was 54.7%, with heart failure hospitalization occurring in 19.3%. CONCLUSIONS: In this contemporary study, two-thirds of patients with symptomatic aortic stenosis treated medically were potentially appropriate AVR candidates and had poor outcomes. Most had incomplete heart team evaluations, commonly had severe symptoms or lesion severity misinterpreted, and were not evaluated by palliative care. Given the potential for beneficial outcomes among those untreated, further efforts to address these shortcomings are needed.


Assuntos
Estenose da Valva Aórtica/cirurgia , Tomada de Decisão Clínica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Futilidade Médica , Seleção de Pacientes , Encaminhamento e Consulta , Recusa do Paciente ao Tratamento , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Fármacos Cardiovasculares/uso terapêutico , Feminino , Nível de Saúde , Humanos , Masculino , Cuidados Paliativos , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
3.
J Heart Valve Dis ; 25(3): 296-300, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27989039

RESUMO

Peri-aortic hematoma has been recently described as a potentially life-threatening complication following transcatheter aortic valve replacement (TAVR). Patient- and procedure-related factors exist that predispose to peri-aortic hematoma formation, which can progress to myocardial rupture at the aortic root-myocardial junction. While conservative therapy with blood pressure control is the expectant management following peri-aortic hematoma formation, myocardial rupture can occur at the site of the aortic annulus. Hence, interventionists and echocardiologists must be prepared for emergent intervention to salvage the patient once the complication is recognized. The present report highlights the patho-histological findings related to left ventricular outflow tract calcification following TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/complicações , Cardiomiopatias/complicações , Traumatismos Cardíacos/etiologia , Ventrículos do Coração/patologia , Hematoma/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Biópsia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Ecocardiografia Transesofagiana , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/patologia , Próteses Valvulares Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Hematoma/patologia , Humanos , Masculino , Desenho de Prótese , Fatores de Risco , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
4.
J Thorac Cardiovasc Surg ; 150(2): 323-30, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26050849

RESUMO

OBJECTIVE: Severe, late functional tricuspid regurgitation is characterized by annulus dilation, right ventricular enlargement, and papillary muscle displacement with leaflet tethering. However, the early stages of mild tricuspid regurgitation and its progression are poorly understood. This study examined structural heart changes in mild, early tricuspid regurgitation. METHODS: Sequential patients undergoing cardiac computed tomography and transthoracic echocardiography with tricuspid regurgitation were identified and evaluated. The tricuspid annulus area and chamber volumes were measured by computed tomography angiography and categorized by tricuspid regurgitation severity. RESULTS: Patients (n = 622) were divided into 3 groups by tricuspid regurgitation severity: no/trace (n = 386), mild (n = 178), and moderate/severe tricuspid regurgitation (n = 58). Annulus area was highly dependent on and proportional to regurgitation severity and correlated with both right/left atrial enlargement. Annulus area most strongly correlated with right and left atrial volume, and the annulus shape changed from elliptical to circular in moderate/severe tricuspid regurgitation. Mild tricuspid regurgitation was associated with less right/left atrial enlargement than significant tricuspid regurgitation, normal right ventricular size, and annular dilation. Significant tricuspid regurgitation was associated with annular dilation, circularization, and right ventricular enlargement. Mild and significant tricuspid regurgitation were differentiated by annulus area and indexed right ventricular volume. CONCLUSIONS: Tricuspid annular dilation and right/left atrial enlargement comprise early events in mild functional tricuspid regurgitation. Atrial enlargement occurs before right ventricular dilation, which occurs late, when tricuspid regurgitation is severe. Atrial volume and tricuspid annular dilation are early and sensitive indicators of tricuspid regurgitation significance.


Assuntos
Ecocardiografia Doppler , Tomografia Computadorizada por Raios X , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Bases de Dados Factuais , Progressão da Doença , Feminino , Hemodinâmica , Humanos , Hipertrofia Ventricular Direita/diagnóstico , Hipertrofia Ventricular Direita/etiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
5.
J Am Coll Cardiol ; 62(4): 317-28, 2013 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-23665364

RESUMO

OBJECTIVES: This study sought to evaluate 4-year outcomes of percutaneous repair versus surgery for mitral regurgitation. BACKGROUND: Transcatheter therapies are being developed to treat valvular heart disease. In the EVEREST (Endovascular Valve Edge-to-Edge Repair Study) II trial, treatment of mitral valve regurgitation (MR) with a novel percutaneous device was compared with surgery and showed superior safety, but less reduction in MR at 1 year overall. We report the 4-year outcomes from the EVEREST II trial. METHODS: Patients with grade 3+ or 4+ MR were randomly assigned to percutaneous repair with the MitraClip (Abbott, Menlo Park, California) device or conventional mitral valve surgery in a 2:1 ratio (184:95). Patients prospectively consented to 5 years of follow-up. RESULTS: At 4 years, the rate of the composite endpoint of freedom from death, surgery, or 3+ or 4+ MR in the intention-to-treat population was 39.8% versus 53.4% in the percutaneous repair group and surgical groups, respectively (p = 0.070). Rates of death were 17.4% versus 17.8% (p = 0.914), and 3+ or 4+ MR was present in 21.7% versus 24.7% (p = 0.745) at 4 years of follow-up, respectively. Surgery for mitral valve dysfunction, however, occurred in 20.4% versus 2.2% (p < 0.001) at 1 year and 24.8% versus 5.5% (p < 0.001) at 4 years. CONCLUSIONS: Patients treated with percutaneous repair of the mitral valve more commonly required surgery to treat residual MR; however, after the first year of follow-up, there were few surgeries required after either percutaneous or surgical treatment and no difference in the prevalence of moderate-severe and severe MR or mortality at 4 years. (Endovascular Valve Edge-to-Edge Repair Study [EVEREST II]; NCT00209274).


Assuntos
Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Intervenção Coronária Percutânea/normas , Seguimentos , Humanos , Insuficiência da Valva Mitral/mortalidade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
7.
Circulation ; 108(4): 452-6, 2003 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-12860909

RESUMO

BACKGROUND: The use of aortic connectors for proximal saphenous vein bypass graft anastomoses eliminates the need for aortic clamping during coronary artery bypass grafting (CABG) and may reduce the incidence of stroke in the elderly and in patients with severe aortic atherosclerosis. METHODS AND RESULTS: We studied 74 consecutive patients who received the Symmetry Bypass System aortic connector at the time of CABG. A total of 131 of 144 proximal vein graft anastomoses were performed with this device. The left internal mammary artery was used in 62 patients, and 61 patients had "off-pump" coronary revascularization. A total of 11 patients were readmitted with chest pain consistent with unstable angina 173+/-39 days after CABG. Five of the 11 patients had previous in-stent restenosis before CABG. At angiography, 20 saphenous vein bypass grafts containing 19 connectors were found to have severe stenosis (n=12) or occlusion (n=6) and were treated with angioplasty and stenting or medical therapy. Seven of 11 patients were readmitted 76+/-11 days later with recurrent chest pain and were found to have severe stenosis at the previously stented connector site. Six patients underwent angioplasty followed by brachytherapy. Three of these patients redeveloped chest pain and were readmitted 151+/-71 days later. Two patients were started on oral Rapamune, and one patient underwent redo-CABG. CONCLUSIONS: Eleven of 74 patients who received aortic connectors at the time of CABG developed symptomatically significant stenosis or occlusion at the connector site shortly after CABG, requiring multiple repeat interventions, including brachytherapy.


Assuntos
Aorta , Prótese Vascular , Ponte de Artéria Coronária/métodos , Veia Safena , Idoso , Angioplastia Coronária com Balão , Aorta/cirurgia , Prótese Vascular/efeitos adversos , Prótese Vascular/estatística & dados numéricos , Braquiterapia , Dor no Peito/etiologia , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/instrumentação , Reestenose Coronária/diagnóstico , Reestenose Coronária/cirurgia , Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Anastomose de Artéria Torácica Interna-Coronária/efeitos adversos , Terapia a Laser , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Recidiva , Reoperação , Veia Safena/cirurgia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
8.
Catheter Cardiovasc Interv ; 59(3): 329-32, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12822151

RESUMO

We describe a case of rotational atherectomy (RA) used in the setting of extensive coronary dissection. Unsuccessful predilitation of a heavily calcified proximal LAD stenosis resulted in balloon rupture, which produced occlusive dissection extending into the mid LAD. Limited options for this patient required that we perform RA to permit stent delivery and deployment and avoid anterior myocardial infarction. A brief discussion of reasons for balloon angioplasty failure and the potential role for subsequent RA is given. Predictors for coronary perforation when performing RA are reviewed. Our rationale and strategy to avoid the increased risk of perforation with RA in this contraindicated setting of extensive dissection is given.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Aterectomia Coronária/métodos , Reestenose Coronária/terapia , Estenose Coronária/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão/métodos , Calcinose/diagnóstico por imagem , Calcinose/terapia , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/terapia , Vasos Coronários/lesões , Falha de Equipamento , Feminino , Seguimentos , Humanos , Medição de Risco , Ruptura Espontânea/diagnóstico por imagem , Ruptura Espontânea/etiologia , Ruptura Espontânea/cirurgia , Índice de Gravidade de Doença , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS