Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38924946

RESUMO

Tyrosine kinase inhibitors (TKIs) are commonly used to treat various cancers. Literature suggests that the blood concentration of TKIs strongly correlates with their efficacy and adverse effects. Therefore, establishing a Therapeutic Drug Monitoring (TDM) methodology for TKI drugs is crucial to improving their clinical efficacy and minimizing the treatment-related adverse effects. However, quantifying their concentrations in the plasma using existing methods to avoid potential toxicity is challenging. Herein, seven TKIs, namely sorafenib tosylate, axitinib, erlotinib, cediranib, brivanib, linifanib, and golvatinib, were successfully analyzed in human plasma by following a quick, easy, cheap, effective, rugged, and safe (QuEChERS) pretreatment method combined with ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Briefly, biological samples were extracted using 1 mL of methanol, followed by the sequential addition of 250 mg of anhydrous magnesium sulfate and 25 mg of N-propylethylenediamine (PSA) for salinization and purification by adsorption, respectively. In this study, dovitinib was used as the internal standard. The seven TKIs were detected by the gradient elution method for 4 min in the positive ion electrospray mode. The mobile phase comprised methanol (phase A) and 0.1 % aqueous formic acid solution (phase B) on the Agilent Zorbax RRHD Stablebond Aq, (2.1 × 50 mm; 1.8 µm). Brivanib, linifanib, axitinib, sorafenib tosylate, and golvatinib exhibited good linearity in the range of 5-500 ng/mL, and erlotinib and cediranib exhibited good linearity in the range of 10-1000 ng/mL, with linear correlation coefficients (R2) ≥ 0.99. The limits of detection and quantification were 0.60-0.18 ng/mL and 5-10 ng/mL, respectively. The intraday and interday accuracy values ranged from -6.12 % to 7.31 %, with a precision (RSD) of ≤ 10.57 %. The method was rapid, accurate, specific, simple, reproducible, and suitable for the quantitative determination of the seven TKIs in human plasma.


Assuntos
Carcinoma Hepatocelular , Limite de Detecção , Neoplasias Hepáticas , Inibidores de Proteínas Quinases , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Proteínas Quinases/sangue , Inibidores de Proteínas Quinases/química , Carcinoma Hepatocelular/sangue , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/tratamento farmacológico , Reprodutibilidade dos Testes , Modelos Lineares , Monitoramento de Medicamentos/métodos , Espectrometria de Massa com Cromatografia Líquida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA